| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹5.9 LAccepted-AOC SHIV NIWAS DHANDA P O TOTU DISTT SHIMLA HP 171011 | SHIMLA | SHIMLA | HIMACHAL PRADESH | 171011 | 1 | Accepted-AOC LOWEST BIDDER | |
| 2 | 2₹6.8 L+₹56,372 (9.06%)Rejected-Finance HOUSE NO 164 SHASTRI NAGAR NEAR JAL NIGAM BABINA CANTT DISTT JHANSI UP | BABINA CANTT | JHANSI | UTTAR PRADESH | 2 | Rejected-Finance NOT LOWEST BIDDER | |
| 3 | 3₹6.8 L+₹61,195 (9.83%)Rejected-Finance VILLAGE TAPARIYAN BABINA CANTT BABINA JHANSI UP 284401 | BABINA | JHANSI | UP | 284401 | 3 | Rejected-Finance NOT LOWEST BIDDER | |
| 4 | 4₹7.0 L+₹76,351 (12.3%)Rejected-Finance 1442 1 NANADANPURA BABINA CANTT TEHSIL DISTT JHANSI UP | BABINA | JHANSI | UP | 4 | Rejected-Finance NOT LOWEST BIDDER | |
| 5 | 5₹7.6 L+₹1.3 L (21.4%)Rejected-Finance S 170 B 192 VILLAGE JHARERA DELHI SOUTH WEST DELHI DELHI 110010 | NEW DELHI | DELHI | 110010 | 5 | Rejected-Finance NOT LOWEST BIDDER |
Tender Value
Refer Docs
EMD Value
₹19,772
Closing Date
1 Jul 2023, 6:00 pmClosed
AGE I TALBEHAT
LAKEVIEW CAMP MIL STN TALBEHAT 284125
REWIRING TO CERTAIN BLDGS IN ZONE 11, 12, 9A AND 06 AT MIL STATION TALBEHAT
2023_MES_598747_1
AGE(I)/TBT/TOK-39/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE I TALBEHAT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE I TALBEHAT
₹19,772
Yes
1 Sept 2023
26 May 2023
3 Jul 2023
2 Jun 2023
1 Jul 2023
9 Jun 2023
Amount
Taking down carefully copper/Aluminium point wiring (light/fan/socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets etc., removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of wall, floors etc. complete all as directed.
Taking down carefully complete light fittings removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of wall, floors etc. complete all as directed.
Taking down Distribution Boards along with MCB's incl removing the same from site and making good to the disturbed surface complete. Note: All taken down MCBs should be deposited to MES store by the contractor without any extra charge.
Taking down existing sub main wiring of any type and description including removal of teak wood batten/pipe etc. complete.
M/L for point wiring concealed type with 1.5sq mm FRLS PVC insulated unsheathed single core multistranded copper conductor cable 1100 volts grade incl 1.5 Sq mm PVC insulated unsheathed copper conductor cable as earth continuity conductor drown through in and incl FRLS PVC rigid conduit not less than 20 mm dia with its accessories pressed steel terminal box incl 3mm thick ISI marked laminated sheet cover for fixing switches/socket/regulators and making good disturbed surfaces of wall, floors etc. for the following: Note:- On RCC ceiling/column, false ceiling, AC/Metallic Sheet ceiling wiring done on surface with conduit/PVC Casing capping and its accessories.
One light/fan/bell point controlled by one No piano type switch 5 Amps single pole one way
One socket outlet 5/3 pin 6 Amps controlled by one switch on the same board.
One socket outlet 5/3 pin 6 AMPS controlled by one switch on independent board.
All as per item NO 5 above but 3 pin socket out let 15/16 Amps on the independent Board all as spfd with single core unsheathed PVC insulated cable multistranded copper conductor of size 2.5 sq mm for phase & neutral & 2.5 sq mm for earth continuity conductor.
S&F Switch Piano Flush button single pole one way 5/6 Amp.
S&F Switch Piano Flush button single pole one way 15/16 Amp.
S&F socket outlet 2 in 1, 3 pin & 2 pin, 5/6 Amp, 240 volt.
S&F socket outlet 2 in 1 , 3 pin & 2 pin, 5/6 Amp and 15/16 Amp, 240 volt.
S&F ceiling rose surface Bakelite 65mmx50mm 100watt three terminal.
S&F step type electronic fan regulator flush type on the existing phenolic laminated sheet.
S&F Lamp holder/Batten holder PVC/Polycarbonate insulated body with metal ring and back plate for batten fitting.
S&F Bell Ding Dong type, AC 230 Volts, Single pole.
S&F Bell Push, flush type, 5 Amp, AC-230 Volts, single pole.
M/L for point wiring casing capping/conduit type with 1.5sq mm FRLS PVC insulated unsheathed single core multithreaded copper conductor cable 1100 volts grade incl 1.5 Sq mm PVC insulated unsheathed copper conductor cable as earth continuity conductor drown through in and incl pressed steel terminal box incl 3mm thick laminated sheet cover for fixing switches/socket/ regulators etc. for the following: Note:- On RCC ceiling/column, false ceiling, AC/Metallic Sheet ceiling wiring done on surface with conduit/PVC Casing capping and its accessories.
One light/fan/bell point controlled by one No piano type switch 5 Amps single pole one way
One socket outlet 5/3 pin 6 AMPS controlled by one switch on independent board.
S&F Switch modular type with plate and cover single pole one way 6/10 Amp 240 volt.
S&F Switch modular type with plate and cover single pole one way 16/20 Amp 240 volt.
S&F for modular type socket 2 & 3 Pin 6/10 Amp with plate and cover, suitable for 2 module 240 volt. MAKE:-Havells(Reo)/Anchor(Roma classic)/Philips
S&F for socket modular type 2 & 3 Pin 6/16 Amp flush type, with plate and cover, suitable for 2 module.
S&F Bell push modular type with plate and cover single pole one way 6 Amp 240 volt.
S&F fan regulator modular type electronic with plate and cover for 2 modules 100 watt, 240 volt.
M&L for sub main wiring concealed with two single core PVC insulated of size 6 sqmm FRLS unsheathed copper conductor 1100 volt grade multistranded and incl drawn through and including non metallic rigid PVC conduit and conduit accessories of 25 mm external dia and conduit FRLS accessories of ISI marks medium grade including 6.0 sqmm FRLS copper wire for earth continuity wire and connected of common earth dolly and making good to the disturbed surface complete. Note:- (i)One run of conduit two run of 6 sq mm copper conductor & one run of 6.0 sq mm copper conductor is measured as one unit. (ii) On RCC ceiling/column, false ceiling, AC/Metallic Sheet ceiling wiring done on surface with conduit and its accessories.
M&L for sub main wiring concealed with two single core PVC insulated of size 4.0 sqmm FRLS unsheathed copper conductor 1100 volt grade multistranded and incl drawn through and including non metallic rigid PVC conduit and conduit accessories of 20 mm external dia and conduit FRLS accessories of ISI marks medium grade including 4.0 sqmm FRLS copper wire for earth continuity wire and connected of common earth dolly and making good to the disturbed surface complete. Note:- (i)One run of conduit two run of 4 sq mm copper conductor & one run of 4.0 sq mm copper conductor is measured as one unit. (ii) On RCC ceiling/column, false ceiling, AC/Metallic Sheet ceiling wiring done on surface with conduit and its accessories.
S&F in replacement single pole and neutral enclosure with a two pin and earth socket complete with top and one single pole MCB of 20 Amp 240 volt and making good to the disturbed surface complete.
S&F sheet metal enclosure double door for MCB DB single pole and neutral 8 way with 200 Amps 240 volts and making good to the disturbed surface complete.
S&F vertical sheet metal enclosure double door for MCCB DB Triple pole and neutral 4 way, (4+12) with 200 Amps rated bus bar 440 volts earth dolly IP-43, IK09, and making good to the disturbed surface complete.
S&F MCB SP 5 to 63 Amps 240 volts 'C' series, 10 KA, 50 Hz, confirming to IS/IEC-60898-1. Make:- As approved Make of DB
S&F MCB SPN 32 to 40 Amps 240 volts 'C' series, 10 KA, 50 Hz, confirming to IS/IEC-60898-1. Make:- As approved Make of DB
S&F MCCB 4pole 63 Amp, 440 volt 'C' series, 16 KA, 50 Hz, confirming to IS/IEC-60898-1. Make:- As approved Make of DB
Supply and fixing LED 4' batten light 18/20 Watt 230 Volt, complete connection with PVC insulated multi stranded copper flexible wire twin core of suitable size from nearest source complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing LED 2' batten light 9/10 Watt 230 Volt, complete connection with PVC insulated multi stranded copper flexible wire twin core of suitable size from nearest source complete all as specified and as directed by Engineer-in-Charge
Material and Labour for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground( earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized iron earth lead 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in electrical plate No 3 of SSR Pt I including necessary excavation and earth work PCC (1:3:6) type C-1 with 50 mm thick pre cast RCC ( 1:2:4) type B-1 cover slab framed with 50X30X4 mm MS angle (reinforced with 6 mm dia deformed bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar) including providing charcoal or coke and magnesium sulphate in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (medium grade) wire mesh, copper lugs, complete in all respect., GI earth wire protected by 15 mm bore (light grade) galvanized iron pipe and other end connected to the earth bar (test point) made of MS flat (400X32X6 mm) bend in ‘D’ shape and fixed to wall by means of fast nut or bolt grouted in to wall at 1 mtr from plinth height. 4sqmm PVC insulated (colour green) copper conductor single run as earth continuity conductor along with 15 mm PVC conduit grouted in wall or fixed on wall surface to be continued up to main switch board and fix with common earth dolly as directed by EIC . Disposal of soil to a distance not exceeding 50 mtr and necessary testing on completion complete all as specified and as directed.
Supply and laying or fixing in replacement GI tubes light grade 40 mm dia, on place of rusted GI pipe in support of Earth Strip/cables, on roof/pole/wall/laid in floor/in trenches.
Repair and fixing of wooden doors with hinges and colour as existing on Meter box complete all as specified and directed.
Note :- Debris obtained from all items should be removed in low lying areas as directed by Engr-in-charge out of MOD Land. (Rates quoted for items are deemed to be included for this, where removal of debris in the items is not considered.)
m/s bobby enterprises
M/S Kharya Associates
M/S SHIVA TRADERS
Ayush Enterprises
M/s Pooja Electricals
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .