Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 LAccepted-AOC 403 GH MANSADEVI COMPLEX PANCHKULA 134109 HARYANA | PANCHKULA | HARYANA | 134109 | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹8.4 L+₹63,187 (8.13%)Rejected-Finance HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | L2 | Rejected-Finance Other Than L1 | |
| 3 | L3₹8.8 L+₹1.1 L (13.7%)Rejected-Finance BUDOOBAGH NOWPORA 0 KHANYAR SRINAGAR JAMMU KASHMIR 190003 | SRINAGAR | JAMMU AND KASHMIR | 190003 | L3 | Rejected-Finance Other Than L1 |
Tender Value
₹12.6 L
EMD Value
₹25,500
Closing Date
24 Apr 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Cdr, HQ 138 WE
HQ 138 Works Engineers PIN-914138 C/O 56 APO
REPAIR/REPLACEMENT OF HOT WATER SUPPLY PLANTS STAND ALONE HEATERS AND ALLIED SERVICES AT BASE CAMP UNDER GE PARTAPUR
2023_MES_587016_1
138WE/L-11/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE Partapur
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE Partapur
₹25,500
Yes
2 Aug 2023
27 Mar 2023
1 May 2023
27 Mar 2023
24 Apr 2023
10 Apr 2023
Amount
M&L servicing ,testing ,cleaning / Repair of hot water plant make- Alfa Therma /Thermax / rapid cool upto 2,00,000 K Cal/hr capacity water boiler which includes following :- Disconnecting electrically drain out of water opening of burner chamber, blower assembly all accessories & mounting on boiler & taking out helical coil Make : Rapid cool water generator 100000 K Cal/Hrs, cleaning of all parts with chemical agents and reassembling of the same after necessary servicing/repairing/replacement of unserviceable parts as specified in each items mentioned / directed at site including minor repair such as welding, brazing, fabrication etc and all minor items such as nuts, bolt and washer etc, complete all as specified and as directed by Engineer-in-Charge. Note :- Spare parts required for repair/ replacement shall be measured and paid for separately under relevant item given below. The cost on account of fixing of spare parts is deemed to be included in these items only.
Supply and fix Inspection glass (gauge) suitable of HWB, complete all as directed as specified by Engineer-in-Charge.
Supply and fix photocell suitable for Alfa Therm/ Rapid cool / Thermax boilder complete all as per sample all as specified & directed by Engr-in-Charge.
Supply and fix Input ignition transformer 220 Volts having out/input 11 KV to 14 KV suitable for Alfa Therm / Rapid Cool / Thermax boiler complete as per sample complete all as directed & specified.
Supply and fix Ignition electrode suitable for Alfa Therm/ Rapid cool / Thermax boilder complete all as per sample all as specified & directed by Engr-in-Charge.
Supply only Solenoid valve suitable for Alfa Therm / Rapid Cool / Thermax boiler complete all as per sample all as specified & directed by Engr-in-Charge.
Supply and fix Fuel filter body suitable for Alfa Therm / Rapid Cool / Thermax boiler complete all as per sample all as specified and directed by Engineer-in-Charge
Supply and fix Fuel filter suitable for Alfa Therm / Rapid Cool / Thermax boiler complete all as per sample all as specified and directed by Engineer-in-Charge
Supply and fix Fuel pump for burner suitable for Alfa Therm / Rapid Cool / Thermax boiler complete all as per sample all as specified and directed by Engineer-in-Charge
Supply and fix Sequence controller complete all as per sample all as specified and directed by Engineer-in-Charge
Supply and fix Digital temperature controller suitable for Rapid Cool / Thermax boiler complete all as per sample all as specified & directed by Engr-in-Charge.
supply and fix Refractory plate paste top & bottem side and including Gasket change as per sample all as specified & directed by Engr-in-Charge.
Repair of burner and burner assembly of hot water generator of Make : Alfa Therm / Rapid Cool / Thermax model including rewinding of burner, replacement of unserviceable nozzle with new one of suitable size and other connected items all as directed by Engr-in-Charge
Rewinding of electric motor 1.5/2 kw,2/3 HP 3 phase 415 with suitable size super enameled copper wire and insulation as per existing gauge and rating complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of electric motor monoblock of hot water plant 1.5 kw, 2 HP 3 phase 415, 50Hz ,Type MSK22(1Ph) , size 50x40 mm,2800 rpm with complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement pressure jet burner assembly complete set suitable for light oil firing with stepless modulation mechanism all as per manufacturur design and of required head and capacity for hot water plant 220-240V, 50-60Hz, 3VA TS max Model No BPZ : L0A24.171B27 complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of heating coils of inside hot water drum of water plant including opening of drum replacement of burn out heating coil (element) repair leakage of drum and refixing the same after replacement work complete all as specified and directed by Engr-in-Charge.
Supplying and laying,connecting,fixing in repair/replacement including taking out the existing pipe and testing of MS ERW'C' class piping complete with fittings,duly insulated with 18mm/13 mm thick closed cell elastomeric insulation 30 to 40 KG/m3 density for the following sizes of Hot Glycol fluid pipes. (The pipes shall be provided with 24 SWG aluminium cladding over the insulation for exposed piping only and underground pipe shall be laid down till 1.5m in depth). (a) 80mm bore pipe with 25mm thick nitrile insulation
(b) -Ditto- all as per item no 18 but 65mm bore pipe with 13mm thick nitrile insulation
(c) -Ditto- all as per item no 18 but 50mm bore pipe with 13mm thick nitrile insulation
(d) -Ditto- all as per item no 18 but 40mm bore pipe with 13mm thick nitrile insulation
(e) -Ditto- all as per item no 18 but 32mm bore pipe with 13mm thick nitrile insulation
(f) -Ditto- all as per item no 18 but 25mm bore pipe with 13mm thick nitrile insulation
Excavatoin in trenches not exceedng 1.5 mtr wide but not exceeding 1.5 mtr in depth for laying of pipe and getting out all in hard and dence soil.
Returning filling in including spreading watering and well ramming in layer not exceeding 25mm thick in hard dence soil
Removing excavated material (soil) to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above starting point.
M&L for cement concrete in foundation, filling and mass concrete type B1 1:2:4 using 20mm graded stone aggregate for foundation.
M&L for dismantling Standalone air heater for space heating of capacity upto 50000 Kcal/hr by unscrewing and removal of heater side/end plates, with scalent de-carbonizing, scraping out carbon ,dirt acculated in heater, overhauling, servicing incl re- assembling all the dismantled component to its original position with testing and commissioning all as specified and directed by Engineer-in-Charge.
M&L for dismantling of the blower motor of Stand alone air heater for space heating of capacity upto 50000 K/Cal Hr incl rewinding of blower motor with suitable size/gauge of copper wire including replacement of suitable blower fan sweep and blower fan guard and refixing of the same after varnishing all as specified and directed by Engineer-in-Charge.
M&L for dismantling Standalone air heater for space heating of capacity upto 25000 Kcal/hr by unscrewing and removal of heater side/end plates, with scalent de-carbonizing, scraping out carbon ,dirt acculated in heater, overhauling, servicing incl re- assembling all the dismantled component to its original position with testing and commissioning all as specified and directed by Engineer-in-Charge.
M&L for dismantling of the blower motor of Stand alone air heater for space heating of capacity upto 25000 K/Cal Hr incl rewinding of blower motor with suitable size/gauge of copper wire including replacement of suitable blower fan sweep and blower fan guard and refixing of the same after varnishing all as specified and directed by Engineer-in-Charge.
M&L for dismantling Standalone air heater for space heating of capacity upto 10000 Kcal/hr by unscrewing and removal of heater side/end plates, with scalent de-carbonizing, scraping out carbon ,dirt acculated in heater, overhauling, servicing incl re- assembling all the dismantled component to its original position with testing and commissioning all as specified and directed by Engineer-in-Charge.
M&L for dismantling of the blower motor of Stand alone air heater for space heating of capacity upto 10000 K/Cal Hr incl rewinding of blower motor with suitable size/gauge of copper wire including replacement of suitable blower fan sweep and blower fan guard and refixing of the same after varnishing all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement blower motor of 1 hp or suitable for capacity of Stand alone air heater, 230 volt 50 Hz,for space heating of capacity of stand alone heater upto 50000 K/Cal Hr incl all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement insulated puff water tank 500 ltr insulated cylindrical vertical type doble layer duly filled with glass wool with closed top hoisted and to resist in temperature -30 degree to +35 degree celcius fixed in position with all fittings over PCC plateform complete all as specified and directed.
national engineering
Top Mind Industries Pvt Limited
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .