Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹33.5 LAccepted-AOC | 1 | Accepted-AOC Being lowest and reasonable | |
| 2 | 2₹38.5 L+₹3.2 L (9.06%)Rejected-Finance | 2 | Rejected-Finance Not being the lowest bidder | |
| 3 | 3₹42.1 L+₹6.9 L (19.5%)Rejected-Finance | 3 | Rejected-Finance Not being the lowest bidder |
Tender Value
₹47.5 L
EMD Value
₹95,000
Closing Date
15 Jun 2023, 6:00 pmClosed
GE(I) R AND D RCI, HYDERABAD
GE(I) RND RCI, MILITARY ENGINEER SERVICES, VIGNYANAKANCHA, RCI, HYDERABAD
REPAIRS MAINT OF WATER SUPPLY RAISING MAIN OF DI CI GI PIPE LINES, VALVES, PUMPS MOTORS ALONGWITH ASSOCIATED PLUMBING ITEMS AND REPAIR MAINT OF SERVICE TANK CLEANING OF OH UG SEMI UG SUMP WATER TANKS AT RESIDENTIAL AREA CPDC ELSEC DSC EETF AND ETC U
2023_MES_596495_1
8827
Open Tender
Civil Works - Water Works
Item Rate
240 days
GE(I) R AND D RCI, HYDERABAD
MES enlisted Class D category a ii and Un enlisted Meeting enlistment criteria of D class in MES and having no recovery pending. For further details ref NIT
8 documents required · 8 mandatory
₹500
Yes
GE(I) R AND D RCI, HYDERABAD
₹95,000
Yes
17 Jul 2023
18 May 2023
17 Jun 2023
18 May 2023
15 Jun 2023
1 Jun 2023
Amount
Taking up or down 20mm bore steel tubing along with connections and all fittings from trenches / walls / floors complete all as directed.
All as per item No 1 above but 25mm bore of pipe.
All as per item No 1 above but 40mm bore of pipe.
All as per item No 1 above but 50mm bore of pipe
All as per item No 1 above but 80mm bore of pipe.
All as per item No 1 above but 100mm bore of pipe Note for item No 1 to 6: Excavation and earthwork if any will be measured and paid separately.
S&F, 20mm bore steel water tubing, medium grade, ISI marked, galvanized, including all fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc., laid in trenches or fixed to walls and ceilings or concealed in walls, ducts/ceilings or laid in floors complete all as specified and directed.
All as per item No 7 above but 25mm bore of pipe.
All as per item No 7 above but 40mm bore of pipe.
All as per item No 7 above but 50mm bore of pipe.
All as per item No 7 above but 80mm bore of pipe.
All as per item No 7 above but 100mm bore of pipe.
S&F in repairs, 15mm dia Gun metal, globe or gate valves with iron wheel head, ISI marked screwed both ends for iron/GI pipe and fixed complete all as specified and as directed.
All as per item No 13 above but 20mm dia globe or gate valve.
All as per item No 13 above but 25mm dia globe or gate valve.
All as per item No 13 above but 40mm dia globe or gate valve.
All as per item No 13 above but 50mm dia globe or gate valve.
Taking up or down CI/DI pipes of 100mm bore with all pipe fittings from trenches, supports etc., complete all as directed.
All as per item No 18 above but 150mm bore of pipe.
All as per item No 18 above but 200mm bore of pipe. Note for item No 18 to 20 Excavation and earthwork will be measured and paid separately.
Supply, laying, jointing and testing 100mm bore Ductile Iron pipes with spigot and socketed ends, centrifugally cast, class K-9, conforming to IS in any length with blue epoxy coating laid in trenches complete including jointing by using elastomeric gasket all as specified and directed.
All as per item No 21 above but 150mm bore of pipe.
All as per item No 21 above but 200mm bore of pipe.
M&L, DI fittings for pipes upto 200mm bore such as bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. 'Y' junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs complete all as specified and as directed.
Supply, install, test and commissioning of 80mm bore CI Sluice Valve in repairs, Class PN-1.6, both ends flanged and drilled type with stainless steel spindle including wheel, suitable rubber gasket for flanged joints, ISI marked, including provision of necessary jointing materials nuts and bolts, washers etc., complete all as specified and directed.
All as per item No 25 above but 100mm bore Sluice Valve.
All as per item No 25 above but 150mm bore Sluice Valve.
All as per item No 25 above but 200mm bore Sluice Valve.
S&F in repairs, 50mm bore, PN-1.0 Non Return valve in CI body with bypass arrangement, ISI marked including bolts, nuts & washers and packing material complete all as specified and as directed.
All as per item No 29 above but 80mm bore Non Return Valve.
All as per item No 29 above but 100mm bore Non Return Valve.
Cleaning of over head service tanks (RCC /PVC) of 500litres capacity positioned over roof of buildings by removing the ball valves, plugging inlet, draining out water, removing all mud, silt accumulated at bottom of tank, cleaning thoroughly and washing with chlorine solution for antibacterial disinfections and refixing the ball valves and marking the date of cleaning, next due date of cleaning with white synthetic enamel paint over black background complete all as directed.
All as per item No 32 above but tank of 750litres capacity
All as per item No 32 above but tank of 1000litres capacity
S&F in repairs, 20mm bore premium PTMT Ball valves, high pressure, with epoxy coated aluminium rod and high density plastic ball and fly nut complete, screwed for iron/GI pipe or brass ferrule complete all as specified and directed. Make:Prayag CAT No152 or equivalent as approved by GE
S&F in repairs, 25mm bore premium PTMT Ball valves, high pressure, with epoxy coated aluminium rod and high density plastic ball and fly nut complete, screwed for iron/GI pipe or brass ferrule complete all as specified and directed. Make:Prayag CAT No153 or equivalent as approved by GE
Bailing out the water from the semi underground sump 10,000 litres capacity at CMCD and Carbon Carbon Pump House without causing any interruption to regular water supply, cleaning the walls, roof and floor thoroughly by using scrapper, removing the deposited scales/ fungus/ sludge/dirt etc., cleaning thoroughly with water and bleaching powder, finally cleaning with chlorine solution for complete anti bacterial disinfections complete including removing and disposing of the rubbish materials of the site and writing date of cleaning of the sump on the black ground/board with white synthetic enamel paint complete all as specified and directed.
Draining out the water from the Over Head Reservoir (OHR) 10,000 Litres capacity on 10metres staging at CMCD and CCTW without causing interruption in regular water supply, cleaning the walls, roof and floor of tank complete by scrapping thoroughly with wire brush and removing dirt/dust/scales/sludge etc., cleaning the tank thoroughly with water and bleaching powder, finally cleaning with chlorine solution for complete antibacterial disinfections including removing and disposing off the rubbish out of tank off as directed and writing date of cleaning on the tank on black ground/board with white synthetic enamel paint complete all as specified and directed.
All as per item No 38 above but 2,50,000 Litres capacity OHR on 30m staging at Residential area
Disconnecting electrical connection from the centrifugal pump motor main housing of 25HP capacity and taking out from the installed position, transporting for repairs/ servicing to an approved workshop and transporting back after carrying out repairs, servicing/overhauling, assembling, installing in its original position and connecting up all electrical connections, testing and commissioning complete all as specified and directed. Note: 1) Unit rate quoted shall be deemed to be include the cost of packing materials. 2) Spares replaced will be measured and paid for separately as Supply only.
All as per item No 40 above but 15HP Pumpset.
All as per item No 40 above but 5HP Pumpset.
Disconnecting water and mechanical connection from the impeller and casing of centrifugal pumpset of 25HP capacity and taking out from the installed position, transporting for repairs/servicing to an approved workshop and transporting back after carrying out repairs, servicing/ overhauling, assembling, installing in its original position and connecting up all mechanical and water connections, testing and commissioning complete all as specified and directed. Note: 1) Unit rate quoted shall be deemed to be include the cost of packing materials. 2) Spares replaced will be measured and paid for separately as Supply only.
All as per item No 43 above but 15HP Pumpset.
All as per item No 43 above but 5HP Pumpset.
Cutting and taking out the burnt out winding from the stator carefully, cleaning the stator from the deposits of burnt copper and carbon using necessary cleaning agent and applying slot insulation with Melinex paper and rewinding the stator with super enamelled copper wire of same gauge and same number of turns as that of existing carefully and tying the winding free from induction vibrations and bring the winding to operate on 415 volts three phase AC supply of 50 Hz, preheating in oven and applying the insulating varnish and post heating for attaining proper insulating strength for Pump motor of capacity 25HP complete all as specified and directed.
All as per item No 46 above but 15HP Pump motor.
All as per item No 46 above but 5HP Pump motor.
Supply only DE bearing of 25HP pump motor as that of existing make and model including applying bearing grease complete all as specified.
All as per item No 49 above but 15HP Pump.
All as per item No 49 above but 5HP Pump.
Supply only impellor of 25HP pump motor as that of existing make and model including applying grease complete all as specified.
All as per item No 52 above but 15HP Pump.
All as per item No 52 above but 5HP Pump.
Supply only pump shaft made of carbon steel for 25HP pumpset as that of existing make and model including applying grease complete all as specified.
All as per item No 55 above but 15HP Pump.
All as per item No 55 above but 5HP Pump.
Supply only bush for 25HP pumpset as that of existing make and model complete all as specified.
All as per item No 58 above but 15HP Pump.
All as per item No 58 above but 5HP Pump.
S&F in repairs, DOL Starter in sheet steel enclosure, max motor output at 415volts 3 phase of 5HP, complete all as specified and directed.
S&F in repairs, DOL Starter in sheet steel enclosure, max motor output at 415volts 3 phase of 7.5HP, complete all as specified and directed.
M&L, Construction of brick masonry valve chamber, 750 x 750 x 1000mm (Internal dimensions) with PCC foundation 1:4:8 type D2 using 40mm graded stone aggregate 150mm thick, 100mm wide offsets alround over 100mm thick hard core, brick masonry walls built in CM 1:6, 50mm thick coping and floor in PCC 1:2:4 type B-1 using 20mm graded stone aggregate, finished even and smooth, rendering 15mm thick in cement mortar 1:4, finished even and smooth without using extra cement internally and externally upto 150mm below GL including top of floor including excavation earthwork in any type of soil, 3mm thick mild steel sheet cover fixed on 40mmx40mmx6mm thick angle iron frame with hold fasts embedded in PCC coping with locking arrangement, mild steel handles and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil to a distance not exceeding 50m etc., complete all as specified and directed.
S&F in repairs, 500litres capacity triple layered rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position including connecting up of existing inlet and outlet pipes and ball valve complete all as specified and as directed.
S&F in repairs, 750litres capacity triple layered rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position including connecting up of existing inlet and outlet pipes and ball valve complete all as specified and as directed.
S&F in repairs, 1000litres capacity triple layered rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position including connecting up of existing inlet and outlet pipes and ball valve complete all as specified and as directed.
Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m depth for foundation, for laying of pipes/cables/poles etc., forming bottom surfaces to required slope/gradient where pipe are laid and getting out in any type of soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each layer as in soil complete all as specified and as directed.
Removing excavated material/soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
M&L, Construction of brick masonry valve chamber, 1000 x 1000 x 1000mm (Internal dimensions) with PCC foundation 1:4:8 type D2 using 40mm graded stone aggregate 150mm thick, 100mm wide offsets alround over 100mm thick hard core, brick masonry walls built in CM 1:6, 50mm thick coping and floor in PCC 1:2:4 type B-1 using 20mm graded stone aggregate, finished even and smooth, rendering 15mm thick in cement mortar 1:4, finished even and smooth without using extra cement internally and externally upto 150mm below GL including top of floor including excavation earthwork in any type of soil, 3mm thick mild steel sheet cover fixed on 40mmx40mmx6mm thick angle iron frame with hold fasts embedded in PCC coping with locking arrangement, mild steel handles and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil to a distance not exceeding 50m etc., complete all as specified and directed.
Supply in repairs Single Phasing Preventor with auto start ON Delay Timer (Auto Reset, 50Volts Unbalance, 1NO Contact) provision for connection of Auto/Manual switch externally 415V complete all as specified. Make: Minilec/Powertek/GIC/IndoAsian.
Supply in repairs, Thermal Over Load Relay type MO, relay range 3.5-5.2Amp complete all as specified. Make: L&T CAT NO CS96355OOSO or equivalent in ABB, Siemens, Legrand, Schneider as approved by GE.
S&F in repairs MCCB FP, 63 Amps having current carrying capacitites with adjustable thermal and magnetic settings, 50Hz, 36KA, 415 Volt, conforms to IHA13EBF0063 including provision of copper cable/extended terminals of suitable ratings from MCCBs to busbar and connection of LT cables with MCCBs with suitable size aluminium lugs complete all as specifiedn and directed. Make :Schneider/Havells/C&S/Legrand
Taking up or down 300mm bore steel tubing alongwith connections and all fittings from trenches/wall/floors complete all as directed.
All as per item No. 74 above but 200 mm bore pipe
Supply, laying, welding, fixing, leak proof testing and commissioning of 300mm bore, medium grade mild steel ERW pipes thick conforming to IS 3589 with bitumen wrap coating over the external surface of the pipe including necessary specials/fittings and taking down old unserviceble pipe complete all as specified and directed.
All as per item No.76 above but for 200 mm bore of pipe
M&L in repairs, Earthing complete with galvanized steel earth plate electrode of size 600 x 600 x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of plate not less than 1.5m below normal ground level connected to GI strip 25 x 4mm as earth lead by means of bolts, nuts, washers and check nuts made out of galvanized iron or steel all as shown on Electrical Plate No. 3 of SSR Part-I including testing on completion complete all as specified and directed.
Notes: The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C1 chamber, 50mm thick RCC 1:2:4 type B-1 using 20mm graded stone aggregate cover slab reinforced with 6 Nos of 8mm dia TMT bars both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe medium grade 40mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub-heading earthing, specified on Sl Page No. 446 of SSR Part-II.
GI earth Strip beyond 7.5m will be measured and paid separately.
sandhya enterprises
Richcon Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .