Tender Value
₹3.2 Cr
EMD Value
₹6.4 L
Closing Date
24 Apr 2026, 3:00 pmClosed
EE(C-IV)
3RD FLOOR, SBS PLACE, NEW DELHI-110001
SITC of Air Ventilation System at Basement I and Basement II of 160 nos Type III Flats at Sector VI Pushp Vihar Saket New Delhi
2026_NDMC_289726_1
NIT No.05/EE(E)C-IV/2025-26
Open Tender
Electrical Works
Percentage
120 days
SAKET
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹6.4 L
Office of CEE-I
21 May 2026
10 Apr 2026
24 Apr 2026
10 Apr 2026
24 Apr 2026
10 Apr 2026
17 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply, Installation, Testing & Commissioning of AMCA Certified (For Air and Sound Performance) tube/Vane axial flow fans of different capacities in standard GI/M.S. construction as mentioned below. Entire fan model and AMCA Seal shall appear in technical submittal of fan. Housing to be made from either galvanized steel with a coating of Z275 or mild steel that is hot dipped galvanized to DIN EN ISO 1461 and complete with bird screen at fan outlet. Fans shall be EN Rated for high temperature as suitable for operation at a minimum of 250°C for 2 hours. The electric motor coupler shall be IE- 03/IE-04 squirrel cage induction type conforming to IS-325, IP-55 rated with class `H' insulation. Fan rpm: The speed of the fans shall not be more than 1450 RPM; however fans with 8000 CFM and below may be selected at 2900 RPM. Fan total efficiency should not be less than 65%, and noise level to be 80 db @ 3m distance when measured under hemispherical reverberant room conditions. Quoted price shall be inclusive of sound attenuator at the outlet/inlet of the fan to achieve desired sound levels. Fans mentioned as outdoor type shall be good for outdoor installation with proper cowl and mounting arrangement as per approved shop drawings. Fans shall be as per specifications and design drawings. Note: Contractor Has to take approval on computer generated selection charts and fan curves showing power input and fan motor etc. prior to order the fans. Axial Flow Fans shall follow the design parameters as mentioned below: | |||||
| 1.1 | 21500 CFM, SP 25 mm wg (For upper basement) | - | Nos | - | - |
| 1.2 | 15000 CFM, SP 25 mm wg (For lower basement) | - | Nos | - | - |
| 2Supply, Installation, Testing & Commissioning of AMCA Certified (For Air and Sound Performance) tube/Vane axial flow fans of different capacities in standard GI/M.S. construction as mentioned below. Entire fan model and AMCA Seal shall appear in technical submittal of fan. Housing to be made from either galvanized steel with a coating of Z275 or mild steel that is hot dipped galvanized to DIN EN ISO 1461 and complete with bird screen at fan outlet. Fans shall be EN Rated for high temperature as suitable for operation at a minimum of 250°C for 2 hours. The electric motor coupler shall be IE- 03/IE-04 squirrel cage induction type conforming to IS-325, IP-55 rated with class `H' insulation. Fan rpm: The speed of the fans shall not be more than 1450 RPM; however fans with 8000 CFM and below may be selected at 2900 RPM. Fan total efficiency should not be less than 65%, and noise level to be 80 db @ 3 m distance when measured under hemispherical reverberant room conditions. Quoted price shall be inclusive of sound attenuator at the outlet/inlet of the fan to achieve desired sound levels. Fans mentioned as outdoor type shall be good for outdoor installation with proper cowl and mounting arrangement as per approved shop drawings. Fans shall be as per specifications and design drawings. Note: Contractor Has to take approval on computer generated selection charts and fan curves showing power input and fan motor etc prior to order the fans. Axial Flow Fans shall follow the design parameters as mentioned below: Each fan Capacity 15000 CFM, SP 30 mm wg | |||||
| 3Supply, Installation, Testing & Commissioning of AMCA Certified (For Air and Sound Performance) tube/Vane axial flow fans of different capacities in standard GI/M.S. construction as mentioned below. Entire fan model and AMCA Seal shall appear in technical submittal of fan. Housing to be made from either galvanized steel with a coating of Z275 or mild steel that is hot dipped galvanized to DIN EN ISO 1461 and complete with bird screen at fan outlet. Fans shall be EN Rated UL Listed for high temperature as suitable for operation at a minimum of 250°C for 2 hours. The electric motor coupler shall be IE- 03/IE-04 squirrel cage induction type conforming to IS-325, IP-55 rated with class `H' insulation. Fan rpm:The speed of the fans shall not be more than 1450 RPM, however fans with 8000 CFM and below may be selected at 2900 RPM. Fan total efficiency should not be less than 65%, and noise level to be 80 db as per table below @ 3 m distance when measured under hemispherical reverberant room conditions. Quoted price shall be inclusive of sound attenuator at the outlet/inlet of the fan to achieve desired sound levels. Fans mentioned as outdoor type shall be good for outdoor installation with proper cowl and mounting arrangement as per approved shop drawings. Fans shall be as per specifications and design drawings. Note: Contractor Has to take approval on computer generated selection charts and fan curves showing power input and fan motor etc. prior to order the fans. Axial Flow Fans shall follow the design parameters as mentioned below: Each fan Capacity 15000 CFM, SP 30 mm wg | |||||
| 4Supply, fabrication, installation and testing of wire rope supports complete with end fixing in accordance with the approved shop drawings and as required by the specifications. | |||||
| 4.1 | 0.63 MM (24 Gauge) | - | Sqm | - | - |
| 4.2 | 0.80 MM (22 Gauge). | - | Sqm | - | - |
| 4.3 | 1.00 MM (20 Gauge) | - | Sqm | - | - |
| 4.4 | 1.25 MM (18 Gauge) | - | Sqm | - | - |
stage.html
html • 0.03 MB
cancelled_1.pdf
pdf • 0.34 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.33 MB
BOQ_384741.xls
BOQ • 0.37 MB
CORRIGENDUM_merged.pdf
PDF • 0.57 MB
CORRIGENDUM_merged.pdf
PDF • 0.57 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .