Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance 245 2 RAJPUR ROAD OPPOSITE HOTEL MADHUBAN DEHRADUN | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
₹5,000
EMD Value
₹6.7 L
Closing Date
10 Oct 2024, 2:00 pmClosed
Chief Engineer
PDD Choglamsar
same as above
2024_PDNRE_14206_1
e-NIT No. 57 of ED Leh of 2024-25 dated 21-09-2024
Open Tender
Electrical Works
Turn-key
60 days
l
Please refer Tender documents.
6 documents required · 6 mandatory
₹5,000
Payable To Executive Engineer EDD Leh
₹6.7 L
17 Oct 2024
21 Sept 2024
11 Oct 2024
21 Sept 2024
10 Oct 2024
23 Sept 2024
Amount
DT (Supply Part)
Compact Substation with single panel VCB RMU 630A 11KV + 500KVA Oltc Transformer with RTCC panel +1000 Amps ACB outgoing
RMU 3 way (2 Incomer and Outgoing) VCB
Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
630 mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for DTs
9 Mtr. Long Pole,ST-410 SP33)
33kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
GI Channel/Angle/Flat of sizes including clamps
Galvinized Nuts and Bolts.
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
33kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
HT Meter with HT Cable including Input/Output termination Set (75/5 complete Set (Smart meter)
Wedge Connectors/PG Clamps
Danger Plates with Clamps
GI Barbed Wire for Anti Climbing
Cement bottoming 1:2:4 mix as per REC standards.5cum/pole
Painting of Poles Red Oxide
Painting of Poles Aluminium Paint
Sundry Itemss like aluminium lugs, Jumpers, binding Tape
RCC Tranformer bed for compact 500KVA
VCB Breaker 33KV level, including cables and Gantary complete set
11KV 3 core 185sqmm XLPE cable FRLS (One Spare Cable)
Outdoor cable termination Kits
Indoor cable termination Kits
Transformer Fencing
DT (Installation/Testing/Commissioning Part)
Compact Substation with single panel VCB RMU 630A 11KV + 500KVA Oltc Transformer with RTCC panel +1000 Amps ACB outgoing
RMU 3 way (2 Incomer and Outgoing) VCB
Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
630 mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for DTs
9 Mtr. Long Pole,ST-410 SP33)
33kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
GI Channel/Angle/Flat of sizes including clamps
Galvinized Nuts and Bolts.
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
33kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
HT Meter with HT Cable including Input/Output termination Set (75/5 complete Set (Smart meter)
Wedge Connectors/PG Clamps
Danger Plates with Clamps
GI Barbed Wire for Anti Climbing
Cement bottoming 1:2:4 mix as per REC standards.5cum/pole
Painting of Poles Red Oxide
Painting of Poles Aluminium Paint
Sundry Itemss like aluminium lugs, Jumpers, binding Tape
RCC Tranformer bed for compact 500KVA
VCB Breaker 33KV level, including cables and Gantary complete set
11KV 3 core 185sqmm XLPE cable FRLS (One Spare Cable)
Outdoor cable termination Kits
Indoor cable termination Kits
Transformer Fencing
HTLine (Supply Part)
9 Mtr. Long Pole ( ST-410 SP33)
GI V cross-arm with top Bracket including clamp(14.631 kg/complete V-set)
GI Channel X-Arm 1600mm long including clamps and braces (75x40x6mm) GI Channel (weight per channel = 11.42kg, back clamp for cantilever 50x8mm, 365mm long = 1.15kg Total weight = 12.57kg/Channel +Clamp) GI Angle 65x65x6mm, 1760mm long including clamps and braces in kgs (weight = 10.21kg, Guy clamp for cantilever 50x8mm, 300mm long = 0.9kg, Total weight = 11.11kg) Total weight = 23.68Kg
GI Canel x-arm including clamp and bress for DP (80kg/DP)
50 mm² ACSR Conductor
33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
33kV Polymeric composite Disc Insulator 36kV, 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
Galvinized Nuts and Bolts
Danger Plates with Clamps
Anti-Climbing Device with Clamps
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
Red Oxide
Aluminium Paint
Silicon Cover
Cement bottoming 1:2:4 mix as per REC standards ..5cum /pole
HT Line (Installation/Testing/Commissioning Part)
9 Mtr. Long Pole ( ST-410 SP33)
GI V cross-arm with top Bracket including clamp(14.631 kg/complete V-set)
GI Channel X-Arm 1600mm long including clamps and braces (75x40x6mm) GI Channel (weight per channel = 11.42kg, back clamp for cantilever 50x8mm, 365mm long = 1.15kg Total weight = 12.57kg/Channel +Clamp) GI Angle 65x65x6mm, 1760mm long including clamps and braces in kgs (weight = 10.21kg, Guy clamp for cantilever 50x8mm, 300mm long = 0.9kg, Total weight = 11.11kg) Total weight = 23.68Kg
GI Chanel x-arm including clamp and bress for DP (80kg/DP)
50 mm² ACSR Conductor
33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
33kV Polymeric composite Disc Insulator 36kV, 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
Galvinized Nuts and Bolts
Danger Plates with Clamps
Anti-Climbing Device with Clamps
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
Red Oxide
Aluminium Paint
Silicon Cover
Cement bottoming 1:2:4 mix as per REC standards ..5cum /pole
LT Line (Supply Part)
HDPE Pipe outer 180sqmm inner dia 152mm for laying of LT Cable
3.5C x 185sqmm AL conductor XLPE (E) armoured cable
3.5C x 95sqmm AL conductor XLPE (E) armoured cable
Supply of 415V, 3-phase, 4 wire, 50 Hz, 35 KA/1Sec LT Feeder Pillars comprising of FRP enclosure with combination of Incoming and Outgoing feeder circuits as per the rating & configuartion given in the respective SLD's & technical specification with Microprocessor based 4-pole, MCCB of various ratings as incomer & specified rating outgoings with 4-pole, MCCB/4-P MCB's, as per the internal wiring. Bus bars, Link sets, power terminals of adequate size for cable terminations, indications, CT operated TVM, metering as per technical spec, support channels, rain sheds, omplete in all respect. The OGA & Scheme of the panel shall be supplied in line with the technical specification as per the following types
Supply of 415V/230 V, 3-phase, 4 wire and Neutral, 50 Hz, 25-10 KA/1Sec LT service Distribution Pillars comprising of FRP enclosure with combination of Incoming and Outgoing feeder circuits as per the rating & configuartion given in the respective SLD's & technical specification with specified ratings incoming circuit having 4-pole, MCCB with all outgoing provided with U-clamp & fuse assembly sets of the rating as specified in the SLD as per technical specification. Service pillar to be used with combination of Feeder Pillars shall be complete with internal wiring. Bus bars, Link sets, power terminals of adequate size for cable terminations, indications, support channels, rain sheds, complete in drawing. The LT sevice pillar shall be as per the approved minimum IP55 protection class. The LT service panel shall be supplied in line with the technical specification as per the following types
Supply of Chemical earthing complete with all clamps, nuts & bolts, washers etc to be used to achieve the recommended earth resistance value for high resistivity locations.
Supply of termination of 3.5C x 95sqmm
Supply of termination of 3.5C x 185sqmm
Supply of GI Flat 25x6mm for earthing of service pillar
Cement bottoming 1:2:4 mix as per REC standards 0.5cum /foundation of main feeder pillar and sub feeder pillars
1R 4Core X 25sqmm AL Conductor, XLPE, armoured cable
1R 4Core X 16sqmm AL Conductor, XLPE, armoured cable
LT Line (Installation/Testing/Commissioning Part)
HDPE Pipe outer 180sqmm inner dia 152mm for laying of LT Cable
3.5C x 185sqmm AL conductor XLPE (E) armoured cable
3.5C x 95sqmm AL conductor XLPE (E) armoured cable
Installation/Testing/Commissioning of 415V, 3-phase, 4 wire, 50 Hz, 35 KA/1Sec LT Feeder Pillars comprising of FRP enclosure with combination of Incoming and Outgoing feeder circuits as per the rating & configuartion given in the respective SLD's & technical specification with Microprocessor based 4-pole, MCCB of various ratings as incomer & specified rating outgoings with 4-pole, MCCB/4-P MCB's, as per the internal wiring. Bus bars, Link sets, power terminals of adequate size for cable terminations, indications, CT operated TVM, metering as per technical spec, support channels, rain sheds, omplete in all respect. The OGA & Scheme of the panel shall be supplied in line with the technical specification as per the following types
Installation/Testing/Commissioning of 415V/230 V, 3-phase, 4 wire and Neutral, 50 Hz, 25-10 KA/1Sec LT service Distribution Pillars comprising of FRP enclosure with combination of Incoming and Outgoing feeder circuits as per the rating & configuartion given in the respective SLD's & technical specification with specified ratings incoming circuit having 4-pole, MCCB with all outgoing provided with U-clamp & fuse assembly sets of the rating as specified in the SLD as per technical specification. Service pillar to be used with combination of Feeder Pillars shall be complete with internal wiring. Bus bars, Link sets, power terminals of adequate size for cable terminations, indications, support channels, rain sheds, complete in drawing. The LT sevice pillar shall be as per the approved minimum IP55 protection class. The LT service panel shall be supplied in line with the technical specification as per the following types
Installation/Testing/Commissioningof Chemical earthing complete with all clamps, nuts & bolts, washers etc to be used to achieve the recommended earth resistance value for high resistivity locations.
Installation/Testing/Commissioningof termination of 3.5C x 95sqmm
Installation/Testing/Commissioning of termination of 3.5C x 185sqmm
Installation/Testing/Commissioningof GI Flat 25x6mm for earthing of service pillar
Installation/Testing/CommissioningCement bottoming 1:2:4 mix as per REC standards 0.5cum /foundation of main feeder pillar and sub feeder pillars
Installation/Testing/Commissioning of 1R 4Core X 25sqmm AL Conductor, XLPE, armoured cable
Installation/Testing/Commissioning of 1R 4Core X 16sqmm AL Conductor, XLPE, armoured cable
M/S LOBZANG GURMET GOVT CONTRACTOR (BID ID -137233)
M/S CHHEIRPON ENTERPRISES (BID ID -137272)
TL CONSTUCTION COMPANY (BID ID -137234)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .