Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
1 Nov 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (WEST) JALANDHAR CANTT
KABIR ROAD JALANDHAR CANTT
Day to day maintenance of Internal electrification of OTM in Zone-II under GE (West) JRC
2025_MES_733920_1
GE/JAL(W)-79/2025-26
Open Tender
Civil Works
Item Rate
335 days
JALANDHAR CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE WEST
₹80,000
Yes
6 Oct 2025
6 Oct 2025
8 Nov 2025
6 Oct 2025
1 Nov 2025
20 Oct 2025
S& F in replacement LED tube set (fitting) 20 W use and through type with internal surge protection device of 4 KV with voltage band 140-280V with LED rod with fixture box type and making electrical connection
M&L for point wiring with PVC insulated, unsheathed cable single core multistranded copper conductor FRLS cable 1.5 sqmm size, 1100V grade, drawn into existing PVC rigid concealed conduit medium grade (ISI marked) including PVC unsheathed cable single core copper FRLS conductor 1.5 Sqmm as continuous earth wire and including pressed MS sheet sunken box 1.6 mm thick with 3 mm thick laminated bakelite sheet all as specified. (a) One light / fan / call bell point controlled by one, one way switch.
Taking down sub main wiring of two single core PVC cable PVC insulated 4 / 6 sqmm including conduit or wooden batten and remove from the site of work and making good the disturbed surfaces of wall or floor etc. as directed by Engineer-in-Charge.
Taking down main switch / DB and making good the disturbed surface as directed by Engineer-In-Charge.
M&L for point wiring with 1.5 sqmm, PVC insulated but sheathed, stranded copper conductor single core FRLS cable, IS-694 marked, drawn through and including non metallic rigid PVC concealed conduit medium grade 20mm dia (minimum) or higher size as specified and cutting chasing on wall complete with all PVC conduit accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc/ fittings ISI marked for modular fittings and brass screws and cup washers including 1.5 sqmm stranded copper conductor PVC insulated FRLS cable green in colour as continuous earth conductor connected to common earth and earth dolly with all accessories complete all as specified and directed. Note : Cost of Metal boxes and modular accessories like cover plates will be paid seprately in respective items) (a) Fan point/ exhaust fan point / one light point / bell/ buzzer controlled by one switch/ bell push.
(b) One socket outet point 5 amps on the same board.
(c) One socket outet point 5 amps on the independent board.
Taking down carefully aluminium / copper point wiring (light / fan / socket or power) while not disturbing existing conduit complete including fitting such as switches, ceiling roses, socket, light fittings, regulators etc complete and making good disturbed surfaces of walls and floors.
Supply and fixing modular metal flush box 1/2 module complete all as specified and directed.
Supply and fixing modular metal flush box 3 module complete all as specified and directed.
Supply and fixing modular metal flush box 4 module complete all as specified and directed.
Supply and fixing modular metal flush box 6 module complete all as specified and directed.
Supply and fixing modular metal flush box 8 module complete all as specified and directed.
Supply and fixing modular metal flush box 12 module complete all as specified and directed.
Supply and fixing modular white cover plate with frame, 1 module complete all as specified and directed.
Supply and fixing modular white cover plate with frame, 2 module complete all as specified and directed.
Supply and fixing modular white cover plate with frame, 3 module complete all as specified and directed.
Supply and fixing modular white cover plate with frame, 4 module complete all as specified and directed.
Supply and fixing modular white cover plate with frame, 6 module complete all as specified and directed.
Supply and fixing modular white cover plate with frame, 8 module complete all as specified and directed.
Supply and fixing modular white cover plate with frame,12 module complete all as specified and directed.
Supply and fixing modular Dummy plate complete all as specified and directed.
All as per Ser item 5.00 here in before but with 2.5 sq mm wire and earth wire (green colour) of 2.5 sq mm for 3 Pin 15 Amp modular type socket outlet.
Supply and fix in repair Modular switch 6 Amps single pole one way as per existing make & model/ as per sample.
Supply and fix in repair Modular switch 16 Amps single pole one way as per existing make & model/ as per sample.
Supply and fix in repair Modular bell bush 5 Amps as per existing make & model/ as per sample.
Supply and fix Modular multi socket 3 pin and 2 pin 6 Amps round and flat as per existing make & model/ as per sample.
Supply and fix in repair Modular socket 6A /16 A Twin socket heavy duty as per existing make & model/ as per sample.
b) All as per Ser item No 28.00 above but for 5 amps socket on independent board
c) All as per Ser item No 28.00 above but for 5 amps socket on same board
Supply & fixing Modular/BLDC regulator electronic switch type 5 steps suitable for 1200/1400 mm sweep 230 volts Make : Khaitan/USHA/Orient/ Polar/ As per sample
All as per Ser item No 28.00 above but with 2.5 sq mm cable for 15 amps switch socket combination outlet on independent board complete all as specified and directed.
(b) All as per Ser item No 32.00 above but for 5 amps socket on independent board
(c) All as per Ser item No 32.00 above but for 5 amps socket on same board
M&L for point wiring in repair with PVC insulated, unsheathed cable single core multistranded copper conductor FRLS cable 1.5 sqmm size, 1100V grade, drawn into and including PVC rigid concealed conduit medium grade (ISI marked) including PVC unsheathed cable single core copper FRLS conductor 1.5 Sqmm as continuous earth wire and including pressed MS sheet sunken box 1.6 mm thick with 3 mm thick laminated bakelite sheet all as specified. a) One light / fan / call bell point controlled by one, one way switch.
All as per Ser item No 32.00 above but with 2.5 sq mm cable for 15 amps switch socket combination outlet on independent board complete all as specified and directed.
Supply & fixing in repair switch piano flush button type single pole one way 5 Amps all as specified. Make: SSK/Havells/Cona.
Supply & fixing in repair bell push single pole 5 Amps all as specified.Make: SSK/Havells/Cona.
Supply & fixing in repair switch piano flush button type single pole 15 Amps.Make: SSK/Havells/Cona.
to ceiling rose all as directed.
Supply & fixing in repair socket outlet 5 Amp flush button type all as specified.Make: SSK/Havells/Cona.
Supply & fixing in repair regulator electronic switch/socket type 5 steps suitable for 1200/1400 mm sweep 230 volts as per sample complete all. Make : Khaitan/USHA/Orient/ Polar.
All as per Ser item No 36.00 above but single pole 5 Amps two way all as specified.Make: SSK/Havells/Cona.
Supply & fixing in repair light fittings decorative LED lunminare for wall mounting multi colour ABS housing with ploycrabonate rings thermo set plastic/glass lamp holder CITY 1 fitting for lamp 1X Eco tone Crystal/ Décor Model No HLDL03160099 along with 15 watt retro fit CFL/LED Spiral along with lamp complete all as specified and as directed. Make Havells
Supply & fixing in repair ceiling roses surfaces bakelite two three terminals 65 x 50 mm all as specified. Make: Anchor/SSK
Supply & fixing in repair lamp holder PVC, insulated body with back plate suitable for batten fittings along with 9 watt LED lamp all as specified. Make: Anchor/SSK
Supply & Fixing MCB single pole, 240 volts, 6 to 32 Ampere, rupturing capacity 10 KA, ‘B’ curve type conforming to Osafe of HPL / Acti 9 series of Schneider /Ekinox3 of Legrand /equivalent in Havells/Hager/L&T/Siemens complete all as specified and directed.
S & F MCB SPN, 240 volts, 40 to 63 Ampere, rupturing capacity 10 KA, ‘B’ curve type conforming to Osafe of HPL / Acti 9 series of Schneider /Ekinox3 of Legrand /equivalent in Havells/Hager/L&T/Siemens complete all as specified and directed.
Supply and fix Sheet metal DB,double door, SPN 8 way for MCB, 240 volt with 200 amps rated bus bar , neutral bar / connectors suitable copper thimbles , lugs etc complete all as specified and directed. Make : EKINOX3 series of Legrand/Acti 9 metalic series of Schneider /Osafe series of HPL/Metallica of Havells/Hager/L&T/Siemens
Supply and fix MCCB 100 Amps 4 pole 415 Volt,25 KA breaking capacity conforming to Osafe of HPL / Acti 9 series of Schneider /Ekinox3 of Legrand /equivalent in Havells/Hager/L&T/Siemens complete all as specified and directed .
Supply & fixing MCCB 3 pole/4 pole of capacity 63 Amps with breaking capacity 16 Kilo Amps including all electrical connections and fixing arrangment conforming to Osafe of HPL / Acti 9 series of Schneider /Ekinox3 of Legrand /equivalent in Havells/Hager/L&T/Siemens complete all as specified and directed .
Supply and fix MCB DB, TPN 6 way double door Vertical type suitable for mounting of MCCB as incomer with suitable 200 amps rated bus bars , Neutral links , blanking plates conforming to Osafe of HPL / Acti 9 series of Schneider /Ekinox3 of Legrand /equivalent in Havells/Hager/L&T/Siemens complete all as specified and directed.
S/F MCB TPN 63 Amps 415 volts as per Osafe of HPL / Acti 9 series of Schneider /Ekinox3 of Legrand /equivalent in Havells/Hager/L&T/Siemens complete all as specifi
ed and directed.
Supply & fixing in repair bell electric (dingdong) 230 volt, SP Make : Anchor .
Supply & fixing in repair Buzzer, AC, 230 Volts, single pole, Make : Anchor
S&F LED tube rod 20 W in existing tube light fittings incl making necessary connections as required for LED tube all as specified and directed.
Supply & fixing of 14 Watt Batten luminaire with Polycarbonate Housing with high quality extruded polycarbonate diffuser. The luminaire should have a CRI > 80 and CCT of 6500K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 2100 nominal lumens and an outstanding System efficacy of at least 150 lumen/watt and maximum system wattage of 14 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours @ design ambient temp 45 deg C. The electronic driver used shall have a power factor >0.95 and THD <15% and suitable for an operating voltage range of 140-270V AC. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Havells Cat no LUMILINEXS14WLED865SPCWH` equivalent in Signify/Wipro.
Supply & fixing of 20 Watt Batten luminaire with Polycarbonate Housing with high quality opal finish diffuser. The luminaire should have a CRI > 80 and CCT of 6500K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 2000 nominal lumens and an System efficacy of at least 100 lumen/watt and maximum system wattage of 20 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours @ design ambient temp 45 deg C. The electronic driver used shall have a power factor >0.95 and THD <10% and suitable for an operating voltage range of 140-270V AC. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Havells Cat no LUMILINEPROBS20WLED865SPCWHIND equivalent in Signify/Wipro.
Supply & fixing of Recess LED 2x2 luminaire with CRCA powder coated housing suitable with high transmittance opal diffuser for glare free symmetric lightb distribution for general lighting in office areas. The luminaire should have a color consistency SDCM < 5, CRI > 80 and CCT of 4000 K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3420 nominal lumens and an outstanding System efficacy of greater than 113 lumen/watt and maximum system wattage of 30 Watts.The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours @ design ambient temp 45 deg C. The electronic driver used shall have a power factor >0.95 and THD <10% , EMC EMI CISPR 15 complaint, Ripple <5% (Flicker Free), Short-circuit protection, 4KVA Surge and suitable for an operating voltage range of 140-270V AC. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Havells Cat no VENUSEXL2X2PLR30WLED840SWH equivalent in Signify/Wipro.
Supply & fixing of Recess LED 2x2 luminaire with CRCA powder coated housing suitable with high transmittance opal diffuser for glare free symmetric lightb distribution for general lighting in office areas. The luminaire should have a color consistency SDCM < 5, CRI > 80 and CCT of 5700K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3600 nominal lumens and an outstanding System efficacy of atleast 120 lumen/watt and maximum system wattage of 30 Watts.The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours @ design ambient temp 45 deg C. The electronic driver used shall have a power factor >0.95 and THD <10% , EMC EMI CISPR 15 complaint, Ripple <5% (Flicker Free), Short-circuit protection, 4KVA Surge and suitable for an operating voltage range of 140-270V AC. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Havells Cat no VENUSEXL2X2PLR30WLED857SWH equivalent in Signify/Wipro.
S & F in repair surface mounted LED Battern with LED tube rod 2 Feet 10W internal surge protection device of 4 KV with voltage band 140-280V and making electrical connection to ceiling rose all as directed. Make Havells, Bajaj, C & S
Supply and fix of hexagon shaped LED bulkhead industrial luminaire with Pressure die cast housing and Polycarbonate diffuser and silicon gasket. The luminaire should have a color CRI > 80, and CCT of 5700K. The luminaire shall be compliant with IP66 & IK 10 classification. Luminaire shall be designed to emit at least 1000 nominal lumens at a system efficacy of at least 100 lumen/watt with a maximum system wattage of 10 Watts. The electronic driver used shall have a power factor >0.95 and THD <15% and suitable for an operating voltage range of 180-270V AC and 4 Kv inbuilt surge protection. Manufacturer shall have in house lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Havells Cat no HEXAFT10WLED857SSYMBOPC equivalent in Signify/Wipro
S & F LED bulb 9 Watt White(6000K-6500 K)/Warm(2700K-3200K) with BEE Energy star rating of three star or more and emission of minimum 100 lm/W complete all as specified
S & F LED bulb 12 Watt White(6000K-6500 K)/Warm(2700K-3200K) with BEE Energy star rating of three star or more and emission of minimum 100 lm/W complete all as specified
S & F SITC of high-quality integrated LED Street Light with a minimum system lumen of4750 Lm and system wattage not exceeding 45W with a nominal efficiency 105 lumen/watt. CCT of 5700K with SDCM of < 5 and CRI >70. The housing should be of non-corrosive high-pressure die-cast aluminum with high efficiency LEDs as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 with PF > 0.95. Lifetime of 50K hours @L70. The Luminaire should have Powered by integral, Isolated LED electronic driver (SMPS based constant current supply) with lower THD, Output Open / Short Circuit protection, Phase to Phase protection (Operation at 440 V AC), Over Voltage protection, Surge Voltage protection upto 4 kV.Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/ULaccredited lab to verify above parameters complete all as specified and directed.. Havells Cat no ENDURASUNBEAMSL45WLED757SASYTOPCSENSO equivalent in Signify/Wipro
S & F of SITC of high-quality integrated LED Street Light with a minimum system lumen of 6600 Lm and system wattage not exceeding 60W with a nominal efficiency 110 lumen/watt. CCT of 5700K with SDCM of < 5 and CRI >70. The housing should be of non-corrosive high-pressure die-cast aluminum with high efficiency LEDs as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 with PF > 0.95. Lifetime of 50K hours @L70. The Luminaire should have Powered by integral, Isolated LED electronic driver (SMPS based constant current supply) with lower THD, Output Open / Short Circuit protection, Phase to Phase protection (Operation at 440 V AC), Over Voltage protection, Surge Voltage protection upto 4 kV.Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Havells Cat no ENDURASUNBEAMSL45WLED757SASYTOPCSENSO equivalent in Signify/Wipro
S & F SITC of high-quality LED Flood Light with a minimum system lumen of 6000 Lm and system wattage not exceeding 50 W with a nominal efficiency 120 lumen/watt. CCT of 5700K with CRI >70. The housing should be of pure polyester powder coated die-cast aluminum with high efficiency LEDs as lighting source. The fitting should have PC reflector for maximum output and PC Lens for symmetric distribution & tempered protective Toughened Glass with IP66 protection and impact resistance of IK07 with PF > 0.95. Lifetime of 50K hours @L70. The Luminaire should have Powered by integral, Isolated LED electronic driver (SMPS based constant current supply) with lower THD, Output Open / Short Circuit protection, Phase to Phase protection (Operation at 440 V AC), Over Voltage protection, Surge Voltage protection upto 6 kV.Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Havells Cat no JETAADORNNXTFLS50WLED757SSYMTOTGV2 equivalent in Signify/Wipro
S&F SITC of high-quality LED Flood Light with a minimum system lumen of 12000 Lm and system wattage not exceeding 100 W with a nominal efficiency 120 lumen/watt. CCT of 5700K with CRI >70. The housing should be of pure polyester powder coated die-cast aluminum with high efficiency LEDs as lighting source. The fitting should have PC reflector for maximum output and PC Lens for symmetric distribution & tempered protective Toughened Glass with IP66 protection and impact resistance of IK07 with PF > 0.95. Lifetime of 50K hours @L70. The Luminaire should have Powered by integral, Isolated LED electronic driver (SMPS based constant current supply) with lower THD, Output Open / Short Circuit protection, Phase to Phase protection (Operation at 440 V AC), Over Voltage protection, Surge Voltage protection upto 6 kV.Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Havells Cat no JETAADORNNXTFLS100WLED757SSYMTOTGV2 equivalent in Signify/Wipro
Supply and fixing of new generation, post top, energy saving spun aluminium landscape luminaries with high power 40W suitable for Pole dia 76mm confirming to IP65 Ruby (Clear) Of Havells cat part LHEVBGP7PN6K040. Make Havells or equivalent
Supply and fix of Microwave Sensor enabled Integral LED 4 ft luminaire with extruded housing and Opal diffuser ith ABS end caps. The luminaire should have a color consistency SDCM < 5, CRI > 80 and CCT of 6500K. The luminaire shall be compliant with IP20 classification. Luminaire shall be designed to emit at least 2000 nominal lumens at a system efficacy of at least 100 lumen/watt with a maximum system wattage of 20 Watts. Fixture should cover upto 5 mtr sensor radius coverage area with 120 degree angle after 17 to 30 seconds & 30% light output in case of non-occupancy.The electronic driver used shall have a power factor >0.9 and THD <10% and suitable for an operating voltage range of 140-270V AC. Manufacturer shall have in house lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters complete all as specified and directed. Havells Cat no LUMILINESMART20WLED865PCWH equivalent in Signify/Wipro
M&L for submain wiring with two RUNS of single core 6 sqmm for main wire and one run of single core 4 sqmm as earth wire of stranded copper conductor PVC insulated unsheathed cables drawn through and including concealed in wall and necessary cutting and chasing rigid PVC conduit ISI marked not less than 20 mm dia and all accessories complete all as specified & directed.
Supply and fix MCB DB, TPN 4 way double door with suitable 200 amps rated bus bars , Neutral links , blanking plates conforming to Osafe of HPL / Acti 9 series of Schneider /Ekinox3 of Legrand /equivalent in Havells/Hager/L&T/Siemens complete all as specified and directed. all as specified and directed.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including4mm suspension wire, one twin core cable flat or circulat of size 10 Sqmm 2 Core complete.
M&L for submain wiring with two RUNS of single core 4 sqmm for main wire and one run of single core 1.5 sqmm as earth wire of stranded copper conductor PVC insulated unsheathed cables drawn through and including concealed in wall and necessary cutting and chasing rigid PVC conduit ISI marked not less than 20 mm dia and all accessories complete all as specified & directed.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.24 MB
BOQ_821762.xls
BOQ • 0.28 MB
TenderDocuments79.pdf
Tender Documents • 1.10 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .