Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.8 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹41.2 L+₹1.4 L (3.60%)Rejected-Finance V P O SAROTARI TEHSIL BAROH DISTRICT KANGRA PIN 176037 HP | KANGRA | HIMACHAL PRADESH | 176037 | L2 | Rejected-Finance Quoted L2 | |
| 3 | L3₹42.8 L+₹3.0 L (7.57%)Rejected-Finance HYDERPORA NEAR ELLAQUAI DEHATI BANK SRINAGAR KASHMIR J K 190014 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190014 | L3 | Rejected-Finance Quoted L3 | |
| 4 | L4₹43.6 L+₹3.8 L (9.44%)Rejected-Finance | L4 | Rejected-Finance Quoted L4 | |
| 5 | L5₹47.5 L+₹7.7 L (19.3%)Rejected-Finance AZAD COLONY B 90 FEET ROAD SOURA SRINAGAR J K 190011 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190011 | L5 | Rejected-Finance Quoted L5 |
Tender Value
₹43.6 L
EMD Value
₹87,200
Closing Date
28 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF SRINAGAR
GE AF SRINAGAR AF STN SRINAGAR 190007
PROVN OF STANDBY POWER SUPPLY TO TECHNICAL BUILDING AT 1 WING AIR FORCE UNDER GE (AF) SRINAGAR
2022_MES_558154_1
GE(AF)SGR- 36 OF 2022-23
Open Tender
Civil Works
Item Rate
180 days
GE (AF) SRINAGAR
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE (AF) SRINAGAR
₹87,200
Yes
29 Mar 2023
17 Oct 2022
29 Nov 2022
17 Oct 2022
28 Nov 2022
14 Nov 2022
Amount
Supplying, installation, testing and commissioning of factory assembled silent Diesel Engine driven generating set 1500 RPM of capacity 40 KW/50 KVA output at site ie at 1600 mtrs MSL after derating AC volts 50 C/s, 3 phase , 4 wire, 415 volts , 0.8 PF complete with control panel including integrated powder coated acoustic enclosure as per CPCB regulations and duly certified by agencies/labs designated by CPCB for noise and sound pollution level , etc floor mounted including PCC foundation as per manufacturer's instructions complete all as specified and directed and comprising of the following :
(a) ALTERNATOR shall be self-excited, self-regulated, brush less of 40 KW/50 KVA continuous operation at the speed of 1500 RPM at 415 volts, 50 HZ three phase four wire system with advance electric voltage regulator to ensure high voltage accuracy with ± 1% with class H insulation and SPDP enclosure directly coupled with engine through flexible coupling and conforming to IS -13364 complete - 01 No
(b) DIESEL ENGINE required capacity for driving 40 KW/50 KVA alternator multi cylinder , vertical type, 4 stroke, water cooled , electric start conforming to IS 10001/10002/BS-5514 for continuous running capable of taking 10 % overload for one hour in 12 hours complete and comprising of the following :- (i) Radiator cooling including coolant (ii) Radiator fan with guard (iii) Fly wheel with starter ring (iv) Air cleaner oil bath type (v) Vacuum indicator (vi) Electronic governor class 1A (vii) Exhaust silencer (viii) Fuel filter and fuel hoses (ix) Fuel injection pump (x) Fan and water pump assy (xi) Lub oil filter and Pump (xii) Oil filter (xiii) Exhaust gas driven turbo charger (xiv) Lub oil cooler (xv) Engine maintenance manual with spare part list (xvi) Suitably designed acoustic enclosure as per CPCB norms (xvii) Engine safety shut down system against low lub oil pressure and high water pressure.
(d) Electric starter equipment: The equipment will comprise the following:-
(i) Maintenance free Battery duly initial charged of suitable capacity and Battery lead of adequate capacity as per manufacture recommadation.
(ii) Starter motor
(iii) Starter gearing
(iv) Start / stop push button
(v) Invertor cum battery charger 500 VA capacity suitable to work on 230 volts 50 Hz AC supply system for charging of DG set batteries externally when DG set is in off position.
(vi) Alternator / Dynamo of suitable capacity to charge the batteries while DG set is running complete with auto cut out all as per manufacturer recommendations.
(e) Foundation : PCC of mix 1:3:6 type C2, for foundation for DG set shall be minimum 450 mm above from natural ground level, all as per manufacturer recommendation or required at site or directed by Engr-in-Charge. Cost of the same shall be deemed to be included in the cost of DG Set quoted by contractor.
(f) contractor shall submit following detail before approval of DG set.
(i) Name and address of the engine manufacturer.
(ii) Type approval certificate numbers
(iii) Date of manfucture of engine
(iv) engine conform to envoronment (protection ) Rule 1986
(f) The complete genearting set inclusive control panel base frame coupling etc shall be from the OEM & shall be assembled & tested at engine manufacture workshop and test certificate shall be provide by contractor
(g) Auto Mains failure panel 415 volts 50 Hz suitable for 50 KVA Gen Set made out of 3.15 mm thick CRCA sheet cubical type floor mounted front and rear door openable with locking arrangement duly powder coated suitable for and including the following
(i) Microprocessor based electronic control box for automatic switching on and off of DG set and transfer of load equipped with microprocessor based controller 100% auto manual and 100% by pass arrgement adjustable time delay to engine start standard setting 3 seconds adjustable 0-10 second adjustable time delay on transfer to normal 0-30 secand time delay (adjustable) to engine cool down 0-5 minute adjustbale time delay on transfer to emergency 0-15 seconds. -01 No Make:- Legrand / ABB / Siemens
(ii) MCCB TPN 100 Amp 25 KA 3 Phase 415 Volts 50 Hz -01
(v) digital freqency meter 04 digit flush type 96 mm size for frequency range 30 to 52.5 Hz with built in trensducer - 01 No. Make:- AE cat part No AE-64122 or equivalent of make legrand / Rishab
(vi) Digital power factor meter 440 volts 5 amps with built in transducer, flush type 96 mm size-01 No Make:- AE cat part No AE-66303 or equivalent of make legrand / Rishab.
(vii) indicator lamp LED type 230 volts for Gen / Mian supply On / Off indication and diffrent relay position etc all as required and recommended by manufacture - 01 Set
(viii) bakelite fuse base carrier with HRC fuses 63 amps 415 volts suitable for and including knife type HBC fuse link - 12 Nos Make:- Standard / L&T / Havells
(ix) DC operated relay as required for remote operation fault indicators and auto switching OFF in case of fault in DG Sets - 01 No
(x) All accessories prewired with suitable size PVC insulated copper conductor cable of appropriate size including connections from DG set all as required at site.
(xi) Note : The AMF Panel shall be integrated with respective LT distribution panal and all electrical connections done using copper bus bars PVC sleeved of appropriate rating but not lessthan as of LT panel.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n. exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft / loose soil
Returning filling in, including spreading ,leveling, watering and well ramming in layers not exc 25 cm, complete all as specified and directed.
Removing excavated material exc 250 m but n exc. 500 m and depositing where directed at a level n. exc 1.5 m above the starting point, complete all as specified and directed.
M&L for providing dry river sand as in sand cushioning below and above cable thickness as specified in SSR to under ground cable including punning down of sand in layer all as specified and directed by Engr-in-Charge. Note: for measurement purpose punned thickness of sand will be consider.
Supply and lay factory made un-reinforced precast concrete cable cover, class LV, type 1, flat, size 250 mm x 150 mm x 40 mm complete all as specified and directed by Engr-in-Charge. Make:- MEHTAB TILES, PEARLESS INDUSTRIES, HINDMOZAIC OR STATE ELECTRICITY BOARD APPROVED MANUFACTURER.
M&L for 50 mm bore mild steel galvanised tubing, light grade with all fittings and fixed complete to walls and ceiling or laid in floors / fixed to poles / or passing under road crossing, complete all as specified and directed by Engr-in-Charge.
M&L for 80 mm bore mild steel galvanised tubing, light grade with all fittings and fixed complete to walls and ceiling or laid in floors / fixed to poles / or passing under road crossing, complete all as specified and directed by Engr-in-Charge.
Supply & lay XLPE insulated, PVC inner sheathed, armored with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 35 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing complete. Note:- Earthwork, sand cushion, cable cover will be measured and paid separately under respective items of this Schedule.
Supply & lay XLPE insulated, PVC inner sheathed, armored with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 95 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing complete. Note:- Earthwork, sand cushion, cable cover will be measured and paid separately under respective items of this Schedule.
Supply and installation, testing, commissioning, factory made, CPRI approved, outdoor type, LT Panel board, confirming to IS 5039- with IP-54 protection, made out of 3.15 mm thick CRCA sheet , 415 Volt, 3 phase , 50 HZ supply mounted on and including MS angle section 40 x 40 x 5 mm frame with front and back openable, double door with provision of locking arrangement dust & varmin proof , gasket, TPN busbar shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof, overall powder coated complete all as specifed and directed & Connisting of the following equipments:-
(i) Solid aluminium bus bar 200 Amp for 3 phase , 100 Amp for neutral
(ii) MCCB 100 Amps 35 KA four pole 415 Volts with Over current & Earth fault- 01 No
(ii) MCCB 40 Amps 25 KA four pole 415 volts - 04 Nos
(iii) On load Change over switches of 125 Amps 4 pole 415 volt -1 Nos
(vi) Control wiring with 1.5 Sqmm copper conductor PVC insulated cable -01 set
(vii) Indication lamp RYB -01 set
Note :- Quoted rates shall be deemed to include for foundation of panel in PCC 1:3:6 type C2 and Brick masonary in CM 1:4, & plastering 10 mm thick in CM 1:6, height of foundation shall be minimum 450 mm above ground level complete all as specified and directed by Engg-in-Charge
Material and labour for earthing complete with copper earth plate electrode of size 600 mm x 600 mm x 3 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level with top edge of the earth plate not less than 1.5 m below normal ground level connected to copper earth strip of size 20 x 3 mm by means of bolts, nuts, check nuts and washers of copper and connected to main control board as directed and including provision of concrete pit in PCC (1:2:4) type B1, pre cost RCC earth pit cover reinforced with 8 mm dia TMT bars @ 150mmc/c of size 54 cm x 54 cm x 8cm with two handle for lifting made out of 8mm dia MS bar, provision of funnel, wire mesh, 20mm bore galavanised steel tubing (med grade) for watering. Charcoal 250 Kg and salt 200 Kg in alternate layers, 40 mm bore galavanised steel tubing light grade for protection of earth lead connection including necessary excavation and earth work and testing complete all as shown on electrical plate No 3 of SSR Part-I
Note : Earth strip and protection pipe upto 7.5m is included in the unit rate of this item. Contractor shall quote his rate accordingly.
Material and labour for earthing complete with galvanised earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level with top edge of the earth plate not less than 1.5 m below normal ground level connected to galvanised steel earth strip of size 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised steel and connected to main control board as directed and including provision of concrete pit in PCC (1:2:4) type B1, pre cost RCC earth pit cover reinforced with 8 mm dia TMT bars @ 150mmc/c of size 54 cm x 54 cm x 8cm with two handle for lifting made out of 8mm dia MS bar, provision of funnel, wire mesh, 20mm bore galavanised steel tubing (med grade) for watering. Charcoal 250 Kg and salt 200 Kg in alternate layers, 40 mm bore galavanised steel tubing light grade for protection of earth lead connection including necessary excavation and earth work and testing complete all as shown on electrical plate No 3 of SSR Part-I
Note : Earth strip and protection pipe upto 7.5m is included in the unit rate of this item. Contractor shall quote his rate accordingly.
Electromech Engineers
M/S ZAHOOR AHMAD KHAN
CHINAR CONSTRUCTION TRADERS
FG CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .