Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.4 LAccepted-AOC MAIN BAZAR SURANKOTE DISTT POONCH 185121 J K | SURANKOTE | POONCH | J K | 185121 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹42.9 L+₹8.6 L (25.1%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
Refer Docs
EMD Value
₹66,000
Closing Date
25 May 2021, 6:00 pmClosed
GE 881 EWS
GE 881 EWS C/o 56 APO
REPAIR TO ROOFING, CEILING, ROOF TREATMENT AND OTHER CONNECTED WORK IN BLDG UNDER THE AOR OF AGE B/R-II AND REPAIR/REPLACEMENT TO E/M INTERNAL FITTINGS/ FIXTURES AND WIRING IN UNITS AT POONCH UNDER GE 881 EWS
2021_MES_438868_1
GE/PNH-08/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE 881 EWS C/o 56 APO
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE 881 EWS
₹66,000
Yes
26 Jun 2021
27 Apr 2021
27 May 2021
27 Apr 2021
25 May 2021
12 May 2021
Amount
B&R PORTION:- Disconnecting existing water tanks and setting aside exceeding 500 ltrs and n. exc 1000 ltrs and refixing the same in the same place, complete all as directed and directed.
Taking down existing tarfelt including tiles and Demolition of lime / cement concrete & screed bed complete from roof surfaces including parapets and lowering without disturbing the existing RCC roof slab and removing the same to a distance exc. 50m and n. exc. 100m including roughening of old concrete surface of roof by wire brushing and cleaning the surface to remove all loose dust etc., complete all as directed and directed.
M&L for 15mm thick screed bed or bedding layers in cement mortar (1:4) with mixing of water proofing compound @ 3% in order to maintain proper slope over existing roof surfaces for laying APP based polymeric membrane and finished the surfaces even and smooth without using extra cement, complete all as specified and as directed. (NOTE : Polymeric membrane & WPC shall be measured and paid separately under relevant item of this Schedule 'A').
M&L for Water proofing treatrment to RCC roof slab, including parapet comprising with the following courses of treatment/specification from bottom to top :- (a) Applying bitumenous primer @ 0.4 ltrs per Sqm over plastered surfaces of roof including parapet surface. (b) Over the priming coat laying one layer APP based polymembric membrane of approved manufacturer 3mm thick weight not less than 3 Kgs per Sqm reinforced with non woven polyester febric weight not less than 150 gms per Sqm. Polymeric membrane shall be taken to a height of 60cm (min) and then inserted inside the groove of parapet wall and shall be finished by a membrane flashing. Note :- (i) Laying APP bassed polymenic membrane shall be done torch on methed or as per manufacturer's instructions. (ii) A minimum overlap of 100mm and 75mm should be made at the end and sides of the polymeric membrane respectively and sealed all overlaps and joints as per manufacturer's instruction. ......contd to item No-04.01
(iii) APP bassed polymeric membrane shall be "Dr Fixit" manufacturered by(i) M/S Pidilite Industries(ii) M/S Texsa India Limited (iii)IWL India Limited (c) Applying two coats of Aluminium paint over APP membrane.)
Taking down cement plaster on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and as directed.
M&L for Rendering 15 mm thick in cement mortar 1:4 with mixing of water proofing copound @3% on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement, complete all as specified and as directed ( Note :- WPC shall be measured and paid separately under relevant item of this Schedule 'A').
M&L for Applying two coats of cement base paint on walls including preparation of new plastered or un-plastered surfaces of wall, complete all as directed and directed.
Demolition of cement concerte (unreinforced) of any description and in any position not otherwise specifically provided for complete all as directed and directed.
M&L for Plain cement concrete 1:2:4 type B-1, (using 20 mm graded crushed stone aggregate) as in bed blocks, coping, benching and similar work including necessary form work, complete all as directed and directed.
Dismantling of asbestos cement sheets, plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as directed and directed.
Dismantling timber scantling 40 sq cm and over in section in any position, framed work complete all as directed and directed.
Dismantling wall and ceiling board (fibre, pulp, PVC, insulation etc) or insulation boards/slabs/blankets, any thickness including cover fillets, complete all as directed and directed.
Dismantling mild steel work of any description & position, complete all as directed and directed.
Demolition of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work, complete all as specified and directed.
M&L for Walling of random rubble stone masonry brought upto course, well bonded, bedded and solidly hearted, built in cement mortar (1:6), complete all as specified and directed.
All as per item No. 15 above, but except stone complete all as specified and directed.
Extra over stone walling for hammer dressing with maximum depression on face from straight edge held against the dressed surface not exceeding 40mm to face stones (lime and sand stone) and dressing of face beds and joints, complete all as specified and directed.
S&F 2nd class soft wood as in scantling clean sawn, timber fixed, complete all as directed and directed.
S&F Boarding 2nd class soft wood as in scantling clean sawn 20 mm thick with butt joints, complete all as directed and directed.
S&F Rolled mild steel structural works as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam,tee,angle, channel or flat sections) including distance pieces, cleats etc Fe 410W(Gde E-250), quality 'A' complete all as directed and directed.
All as per item No-20 above but except steel (re-use of mild steel obtained from dismantling), complete all as directed and directed.
S&F Suspended false ceiling using E- grid suspended ceiling grid system of grid size 600x600mm with GI frame work of main runner 38 x 24mm sheet thickness 0.4mm, cross Tee 28 x 24mm sheet thickness 0.3mm and wall angle 24 x 24mm x 0.3mm using 4mm thick high pressure stream cured classic variant E-board, designer pattern (ISI marked, IS No 14862-2000) fibre cement E board to be placed in the grid suspended by 4mm GI wire hangers from the purlins of the roof with butter fly clips including preparation of surfaces and applying two coats of synthetic enamel paint over one coat of primer complete all as specified and directed. Make:- Everest Industries Ltd or equivalent.
S&F Pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, complete all as directed and directed.
S&F Pre-painted galvatume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, complete all as directed and directed.
S&F Asbestos cement corrugated or semi corrugated sheets, 6mm thick, in roofs, fixed with ‘L’ or ‘J’ type hook or cranked bolts complete all as directed and directed.
All as per serial item No. 25 above but except sheets, complete all as directed and directed.
S&F Asbestos cement two piece adjustable ridge for corrugated or semi corrugated sheets, 6 mm thick, fixed with ‘L’ or ‘J’ type hooks, complete all as specified and directed.
S&F 0.63mm thick class-8 galvanised corrugated mild steel sheeting with two corrugation side lap fixed with L-type or J-type or cranked hook bolts, complete all as specified and directed.
All as per serial item No. 28 above but except sheets, complete all as specified and as directed.
S&F Plain, galvanised, 0.80 mm thick mild steel sheeting in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) Class VIII fixed with `L' hooks or cranked bolts etc in lieu of screws, complete all as specified and as directed.
All as per serial item No. 30 above but except sheets, complete all as specified and as directed.
M&L for Preparation of new or untreated steel surface of any description exc. 10 cm in width or girth and applying two coats of synthetic enamel paints over a coat of red oxide primer, complete all as specified and directed.
M&L for Preparation of old treated steel surface of any description exc.10 cm in width or girth and applying one coat of synthetic enamel paint, complete all as specified and as directed.
M&L for Preparation of new or untreated surfaces of wood or wood based surfaces of any description exc.10 cm. in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and as directed.
M&L for Preparation of new wood surfaces of any description and girth, not other wise, described and treated with creosote oil, complete all as specified and directed.
S&F MS work as in wind ties for roof including securing bolts ,flat iron fillets including all necessary drilling, bolting or riveting etc. and similar work conforming to Fe-210 Gde E-165, complete all as specified and directed.
All as per serial item No. 36 above but fixing only, complete all as specified and as directed.
Taking up or down 20 mm bore steel tubing and connections including cleaning, threading for refixing or removal to store, complete all as specified and directed.
Refixing old steel galvanized tubing of 20mm bore including all fittings in new or old position as in walls, ceiling, floors etc, complete all as specified and as directed.
S&F Galvanized steel water tubing, 20 mm bore, medium grade, with all fittings , fixed complete to walls, ceilings or laid in floors, complete all as specified and as directed.
Dismantling water tanks of any description, exc 500 ltr but not exc 1000 litre capacity and removing from site, complete all as specified and as directed.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position of exc 250 ltr but not exc 500 ltr capacity, complete all as specified and as directed.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. of exc 500 ltr but not exc 1000 ltr capacity, complete all as specified and as directed.
S&F Rotational moulded polyethylene water storage tanks triple layer (cylindrical vertical with closed top ) hoisted and fixed in position, including over flow and drain out pipe complete of 1000 litre capacity , all as specified in SSR Part-I, complete all as specified and as directed.
S&F in repair Ball brass valve, high pressure, with polythene float and fly nut complete screwed for iron pipe or brass ferrule and fixed complete of 20 mm bore dia, complete all as specified and as directed.
S&F in repair Stop valve/angle valve cast copper alloy, screwed down high pressure with capstan head, screwed both ends for 20 mm bore iron pipe or for unions and fixed, complete all as specified and as directed.
Supply only water proofing compound complete all as specified and directed.
E&M PORTION:- Taking down carefully copper/ aluminium unserviceable/ perished point wiring (light, fan, socket or power complete including fixture and fittings such as switches, ceiling roses, pandents, regulators, sockets, light fittings,removing material from site for taking credit etc and making good disturbed surfaces of wall, floors, complete all as specifiecd and directed.
Taking down carefully unsv sub main wiring including earth continuity any type/ size with surface casing/ caping/ TW batten/ PVC conduit surface or recess etc and removing materials from sites and making good distrubed surface of walls and roofs complete all as specified and directed.
Taking down carefully unsv main switch / DBs alongwith MCBs any type / capacity and making good disturbed surface to match with the existing surface, complete all as specified and directed.
Point wiring with two single core 1.5 Sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable and one single core 1.5 Sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable as earth continuity to common earth and connecting to earth dolly running in and including PVC casing & caping (ISI marked) of suitable size with PVC boards of appropriate sizes and all requisite accessories such as PVC elbow, Tee, collars, bends etc. with PVC terminals box & cover for mounting swtches, sockets, fan regulator etc for mounting switches, sockets, fan regulators etc complete all as specified and as directed for the following :-
One light/fan point controlled by one way switch 6 Amp complete all as specified and directed.
One ligh point controlled by two way switch 6 Amp complete all as specified and directed.
One 3/5 pin socket outlet 6 amp on same board complete all as specified and directed.
One 3/5 pin socket outlet 6 amp independent board complete all as specified and directed.
One bell point controlled by one way switch 6 Amp complete all as specified and directed.
All as per srl item No 51 here in before but for one 3 pin socket outlet 16/20 Amp independent with two single core 2.5 Sqmm size cable as phase & neutral and one single core 1.5 Sqmm as in continuous earth wire complete all as specified and directed. Make of wiring wire against item No- 51 to 52: Havells/RR Kabel/Finolex
S&F in repair Ceiling rose, 3 phase PVC/poly carbonate, insulated body, complete all as specified and directed. Make:-Havells/Anchor/Legrand
S&F in repair Switch piano flush type 6 Amp single pole one way, (ISI marked), complete all as specified and directed. Make:-Havells/Anchor/Legrand
S&F in repair Switch piano flush type 6 Amp two way, (ISI marked), complete all as specified and directed. Make:-Havells/Anchor/Legrand
S&F in repair Switch piano bell push flush type 5 Amp single pole one way (ISI marked) complete all as specified and directed. Make:-Havells/Anchor/Legrand
S&F in repair Switch socket multipurpose combination 2 in 1, 3 pin, 5 Amp flush type universal, complete all as specified and directed. Make:-Havells/Anchor/Legrand
S&F in repair Switch socket multipurpose combination 2 in 1, 5 pin, 6 Amp flush type universal, complete all as specified and directed. Make:-Havells/Anchor/Legrand
S&F in repair Switch socket outlet multipurpose combination 2 in 1, 6 pin, 5 and 15 Amp flush type universal, complete all as specified and directed. Make:-Havells/Anchor/Legrand
S&F in repair Lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings, complete all as specified and directed. Make:-Havells/Anchor/Legrand
S&F in repair Stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. for 1200 / 1400mm sweep, complete all as specified and directed. Make:-Havells/Anchor/Legrand
S&F in repair Electric bell ding dong type 230 volts AC supply 50 Hz complete all as specified and directed by Engineer-in-Charge. Make:-Havells/Anchor/Legrand
S&F in repair Tube light fitting box type suitable for LED 20W tube rod made out of ultra bright, glass shell, glare free, wide angle, single side connection retofit LED tube with G13 lamp holders complete with hosing with all accessories pre wired and making connection with copper flexible cable of appropriate size from ceiling rose to light fitting including 20LED tube rod 4 feet long with single side connection complete all as specified and directed. Make:-Havells Cat Part No:-LHLDEFXD5L8R020 for LED tube rod & Cat Part No:-LHFXCEP1TNNW020 for batten fittings or Equivalent cat part of make:-Wipro / Crompton / Bajaj Note :- The LED batten and LED tube rod shall be of same make.
S&F in repair gate light fittings, outdoor type, high power LED 25 watt, prewired with suitable pole for mounting complete all as specified and directed. Make: Havells cat part No. CORALPT25WLED757PSYMTOPC or equivalent of Make specified in PS.
S&F in repair LED street light fittings 30W made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 complete with hosing with all accessories pre wired with and including 40mm dia GI pipe bracket of 1.2 mtr made to shape as required fixed on wall or pole with FI clamp of required shap & 40x6mm siize, nut, bolts, washers and making connection with three core copper flexible cable of suitable size to light fitting complete all as specified and directed. Make:-Havells Cat Part No:-ENDURAPEARLSL30WLED757SASYTOPCMP or Equivalent cat part of Make specified in PS
S&F in repair Tube light fitting suitable for LED 10W tube rod fittings including 10 Watt LED tube rod complete with hosing with all accessories pre wired and making connection with copper flexible cable of appropriate size from ceiling rose to light fitting complete all as specified and directed. Make:-Havells Cat Part No:LHEXBYPNIN1W010 or Equivalent cat part of make as specified in Appx 'A' to P.S. Note :- The LED batten and LED tube rod shall be of same make.
S&F in repair Ceiling mounted decorative light fixture made up of polycarbonate, suitable for 18W LED lamp with & including LED lamp and making connection with copper flexible cable of appropriate size from ceiling rose to light fitting complete all as specified and directed. Make: Havells Cat Part No-LHEBFCP7IZ1W018 or Equivalent cat part of make as specified in Appx 'A' to P.S.
S&F in repair 2x2 LED edge-lit luminaire 36 watts suitable for armstrong/grid ceiling complete for low ceiling applications with driver and making connection with copper flexible cable of suitable size to light fitting complete all as specified and directed. Make:-Havells cat part No-STRATO2X2PLR36WLED857MOD for Module and cat part No-LEDDRIVER36V36WS for Driver or Equivalent cat part of make as specified in Appx 'A' to P.S.
S&F in repair 20 W LED tube rod 4 feet long with single side connection complete all as specified and directed. Make:-Havells Cat Part No:-LHLDEFXD5L8R020 for LED tube rod or Equivalent cat part of make as specified in Appx 'A' to P.S.
S&F in repair LED lamp CDL 10 watt with holder base (B22) type, complete all as specified and directed. Make of LED lamp:- Havells cat part No LHLDEUEEML8R010 or Equivalent cat part of make as specified in Appx 'A' to P.S.
S&F in repair LED driver suitable for 36 watt LED ceiiling light fittings and making connection to fitting complete all as specified and directed. Make:-Havells cat part No-LEDDRIVER36V36WS or Equivalent cat part of make as specified in Appx 'A' to P.S.
S&F in repair Single pole and neutral plastic enclosure with a two pin and earth plug and socket for surface mounting complete with one single pole MCB 20Amp 240V, complete all as specified and directed. Make:-Havells cat part No-DHDPHSN020 or Equivalent cat part of make as specified in Appx 'A' to P.S.
S&F Vertical distribution board TPN 4 ways with built in bus bars, neutral links, blanking plates double door suitable for FP MCCB as incommer and out going SP/TP MCBs with & including 63 Amps 4 pole MCCB having 16 KA breaking capacity complete all as specified and directed. Note:- MCCBs and MCBs shall be measured and paid separately. Make:-Havells cat part No-DHDLVDRWGOFO04 for DB and cat part No-IHLGNF0063 for MCCB or Equivalent cat part of make as specified in P.S.
S&F Sheet metal enclosure factory made (Double door) for DBs, single pole and neutral, 240 volts, 4 way with 200Amps rated bus bar fixed on walls, including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning complete all as specified and directed. Make:- Havells cat part No-DHDPSHODPW04 or Equivalent cat part of make specified in PS.
S&F Sheet metal enclosure factory made (Double door) for DBs, single pole and neutral, 240 volts, 8 way with 200Amps rated bus bar fixed on walls, including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning complete all as specified and directed. Make:- Havells cat part No-DHDPSHODPW08 or Equivalent cat part of make as specified in P.S.
S&F Sheet metal enclosure factory made (Double door) for DBs, single pole and neutral, 240 volts, 12 way with 200Amps rated bus bar fixed on walls, including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioningcomplete all as specified and directed. Make:-Havells cat part No-DHDPSHODPW12 or Equivalent cat part of make as specified in P.S.
S&F MCB TPN 40-63 amps 415 volts 10 KA 'C' series, complete all as specified and directed. Make:-Havells cat part No- DHMGCTNF040 - DHMGCTNF063 or Equivalent cat part of make as specified in P.S.
S&F MCB SPN 40-63 amps 415 volts 10 KA 'C' series, complete all as specified and directed. Make:-Havells cat part No- DHMGCSNF040 - DHMGCSNF063 or Equivalent cat part of make as specified in P.S.
S&F MCB single pole 6 to 32 amps 240 volts 10 KA 'C' series complete all as specified and directed. Make:-Havells cat part No-DHMGCSPF006-032 or Equivalent cat part of make as specified in P.S.
Earthing complete with galvanized steel earth plate electrode 60cmx 60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanized iron wire 4.0mm dia by means of bolts, nuts and washers of galvanized iron or steel, protected by GI light grade pipe 15mm bore including GI light grade water pipe 20mm dia with funnel all as shown in electric plate No. 3 of 2009 SSR Pt-I and testing complete including earth work in any type of soil, PCC 1:2:4 type B-1 as in earthing pit and cover 50mm thick reinforced with 6mm dia MS round bar @ 10cm C/C both way and MS frame, common salt, charcoal and testing on completion including dismantling unsv earthing, complete all as specified and directed.
S&F Sub main wiring with single core cable 2x 6 sq mm FRLS insulated unsheathed stranded copper conductor cable 1100 Volts grade including surface PVC casing caping medium grade alongwith 1x 4.0 Sq mm FRLS insulated unsheathed copper conductor cable as earth wire connected with main earth dolly including taking down old unsv sub main wiring of any type, complete all as specified and directed. Note:-2 wire of 6 sqmm, 1 wire of 4.0 sqmm and one run of pvc conduit/casing caping shall be measured as one unit.
S&F Sub main wiring with single core cable 2x 4 sq mm FRLS insulated unsheathed stranded copper conductor cable 1100 Volts grade including surface PVC casing caping medium grade alongwith 1x 2.5 Sq mm FRLS insulated unsheathed copper conductor cable as earth wire connected with main earth dolly including taking down old unsv sub main wiring of any type, complete all as specified and directed. Note:-2 wire of 4sqmm, 1 wire of 2.5 sqmm and one run of pvc conduit/casing caping shall be measured as one unit.
S&F 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor served with PVC tape and over all PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including 4mm dia GI suspension wire, one twin core cable flat or circular of size 6 Sqmm with & including taking down old old unsv service cable connection, complete all as specified and directed.
S&F 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor served with PVC tape and over all PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including 4mm dia GI suspension wire, one twin core cable flat of circular of size 10 Sqmm including taking down existing old service connection, complete all as specified and directed.
Taking out old unsv exhaust fan from site of capacity 380/200 mm sweep and replacement of exhaust fan incl all connecting accessories complete all as specified and directed by Engineer-in-charge.
S&F in repair of PVC counduit non matalic rigid, of size 25 mm dia (external) incl all accessories use for fixing of conduit on wall and ceiling etc, complete all as specified and directed.
S&F in repair PVC casing caping of size 25 mm incl all fixing accessories complete all as specified and directed.
S&F in repair flexible PVC conduit of approved quality of size 25 mm dia bore with fixing materials complete all as specified and directed by Engineer-in-charge.
Repair and maintenance of unserviceable ceiling fan of 1200mm/1400mm sweep at contractor's work shop, incl dismantling complete the ceiling fan parts, inspecting serviceability of all the parts, refixing of serviceable parts after cleaning and replacement of unserviceable parts with company's genuine parts i.e. capacitor, bearing, bushes, shaft, bracket, rubber bush, connecting wire, PVC connector, aluminium clamp for rod, bracket, bush rod, greasing/oiling etc assembling, cleaning and testing of ceiling fan complete all as specified and directed. Note: (i) Unserviceable parts as above shall be measured and paid separately under relevant items of Sch 'A' as supply only. (ii) Rewinding of stator will be measured & paid for separately under relevant item of Sch 'A'. (iii) Cost of minor part i.e. Cotter pin, screws shall be deemed to included in the cost of quoted rate.
S&F in repair bearing good quality for ceiling fan 1200mm/1400mm sweep ISI marked complete all as specified and directed.
S&F in repair Gun metal bush for ceiling fan 1200mm/1400mm sweep complete all as specified and directed.
S&F in repair capacitor 2.5 mfd ISI marked complete all as specified and directed.
S&F in repair brass bracket assy for hanging the ceiling fan 1200mm/1400mm sweep complete all as specified and directed.
S&F in repair 3 core flexible wire 40/.0076, white colour from ceiling rose to fan connector complete all as specified and directed.
S&F in repair stator shaft for ceiling fan complete all as specified and directed.
S&F in repair fan blade for ceiling fan 1200 mm sweep of existing make complete all as specified and directed.
All as per item No. 96 above but for ceiling fan 1400 mm sweep of existing make complete all as specified and directed.
S&F in repair canopy (top/bottom) of ceiling fans any make /size of colour matching with existing canopy/ fan colour complete all as specified and directed.
M&L for removing of old burnt winding of any size , type and rewinding of stator winding with superior quality copper wire with insulation complete all as specified and directed.
M&L for Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified and directed.
M&L for Replacement of down rod of ceiling fan with down rod of 15mm bore medium grade GI pipe 0.45 metre long with clamps, bolts, nuts, split pins washers of suitable size of approved quality complete all as specified and directed by Engineer in charge.
All as per item No 101 above but of length 0.60 Mtr complete all as specified and directed.
Repair and maintenance of unserviceable exhaust fan of any cap and sweep by dismantling the exhaust fan parts, inspecting the serviceability of parts, refixing of serviceable parts after cleaning, replacement of unerviceable parts i.e. beaing, bush, capacitor, connecting wires, fan blade, locknut, rubber pad etc, oiling/greasing, cleaning and testing of exhaust fan complete all as specified and directed. Note: (i) Unserviceable parts replaced shall be measured and paid separately under relevant items of Sch 'A' as supply only. (ii) Rewinding of stator winding shall be measured & paid for separately under relevant item of Sch 'A'. (iii) Cost of minor part i.e. screws shall be deemed to included in the cost of quoted rate.
Supply of double ball bearing (ISI marked) for exhaust fan of 200 mm sweep to 450 mm sweep fan complete all as specified and directed.
Supply of Gun metal bush for Exhaust fan of any cap. complete all as specified and directed.
Rewinding of 450mm sweep exhaust fan motor with superior quality copper winding wire with insulation complete all as specified and directed.
Rewinding of 300mm sweep exhaust fan motor with superior quality copper winding wire with insulation complete all as specified and directed.
S&F in repair blade of exhuast fan of 200 mm sweep to 450 mm sweep as per existing make complete all as specified and directed.
M&L for Preparation of painted surfaces of exhaust fan of any make and size by scrubbing old and applying one coat of synthetic enamel paint by spray painting complete all as specified and directed by Engr-in-Charge.
M&L for disconnecting elect & water connection to geyser of cap 25/50/35 ltr, taking down, from existing position, dismantling and inspecting all the parts, for its serviceability, cleaning of serviceable parts i.e. Heating elemet, base assy, connecting lead, thermostat, electrical contact, electric wiring, indicators, safety valves etc and refixing, replacement of unserviceable parts, re assembling, remounting, reconnecting with electrical & water connectionn and testing complete all as specified and directed. Notes: (i) The defective parts to be replaced shall be measured and paid separately under relevant item of Sch 'A' as supply only. (ii) Cost of minor items i.e. Screws, nut & bolts etc shall be deemed to be included in the above item.
S&F in repair heating element 2.0 KW, ISI marked with gasket suitable for as existing size, type and make of geyser complete all as specified and directed.
All as per item No 111 above but of cap 1.5 KW complete all as specified and directed.
S&F in repair thermostat ISI marked suitable for existing make of the geyser under repair of cap 50/25 /35 Ltrs complete all as specified and directed.
S&F in repair indicator lamp as per existing make and size complete all as specified and directed.
S&F in repair geyser safety valve (pressure release valve) for the exsiting make & capacity of geyser complete all as specified and directed.
S&F in repair geyser pipe connection heavy duty for inlet, outlet connection suitable to withstand the pressure and temperature for existing geyser complete all as specified and directed.
S&F in repair aluminium/cromium type flexible connection heavy duty for inlet, outlet connection suitable to withstand the pressure and temperature for existing geyser complete all as specified and directed.
S&F in repair inner tank made out of steel sheet conform to IS suitable for 25 ltrs capacity of geyser of different makes vertical type complete all as specified and directed.
All as per item No 118 above but for Geysers of capacity 35/50 ltrs complete all as specified and directed.
S&F in repair non return valve made out of brass fixed in veritcal complete all as specified and directed.
S&F in repair new base assembly with inlet and outlet pipe made out of steel base plate with gasket and proper size of nuts, bolts and washer etc suitable for 25 ltrs capacity of geyser complete all as specified and directed.
All as per item No 121 above but of size 35/50 ltrs complete all as specified and directed.
M/S KEWAL KRISHAN SANJEEV KUMAR VAID
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .