| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.1 LAccepted-AOC ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹38.3 L+₹1.2 L (3.24%)Rejected-AOC ROOM NO 220 2ND FLOOR DEVGIRI BUILDING NO 65 B LALLU BHAI COMPOUND MANKHURD MUMBAI 400043 | MUMBAI SUBURBAN | MAHARASHTRA | 400043 | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹41.3 L+₹4.2 L (11.2%)Rejected-AOC | L3 | Rejected-AOC NOT LOWEST | |
| 4 | L4₹44.4 L+₹7.3 L (19.6%)Rejected-AOC 38 30 92 SAI NAGAR MARRIPALEM VISAKHAPATNAM 530 018 | VISAKHAPATANAM | ANDHRA PRADESH | 530018 | L4 | Rejected-AOC NOT LOWEST | |
| 5 | L5₹45.0 L+₹7.8 L (21.1%)Rejected-AOC | L5 | Rejected-AOC NOT LOWEST |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
29 Jan 2024, 6:00 pmClosed
GE (NW) MANKHURD
GE (NW) MANKHURD MUMBAI-88
ADDN/ALTN AND SPECIAL REPAIRS TO BLDG NO P-06 (OLD DG ROOM) AND P-136 (GENERATOR ROOM) AT TS MAHUL AND REPAIRS TO FALSE CEILING AND ALLIED WORKS IN SH-20 AT WED AND UNDER GE (NW) MANKHURD
2024_MES_636197_2
8286/E8
Open Tender
Civil Works
Item Rate
180 days
GE (NW) MANKHURD
As per NIT and Tender Documents
9 documents required · 9 mandatory
₹500
GE (NW) MANKHURD
₹92,000
28 Mar 2024
11 Jan 2024
31 Jan 2024
11 Jan 2024
29 Jan 2024
13 Jan 2024
Amount
M & L for aluminium anodised suspended false ceiling fixed in repairs in the panels of size consisting of 600x600 mm lay in tiles 8 mm thick with PVC lamination on the face side and metalized polyester film on backside as granular pattern of saint gobain/Armstrong/equivalent; with aluminium anodised angle 30x30 x2 mm fixed along the wall and main and cross tees of size 31.75 x 31.75 x 1.6 mm screwed along side of walls fixed with wooden plugs and hanging from existing slab/ steel truss including 6 mm dia GI wire susprnded adjustable level from rafter purlins(length as per site requirement) including complete all as specified and directed by Engineer-in-charge. Note : The contractor's quoted rates shall also be deemed to include for making/ cutting opening in the ceiling of the required size and shape for fixing light fitting, cat walk and provision of neccesary scaffolding for complete work at maximum height of 8 mtrs etc, complete all as directed.
Taking down cement or cement lime plaster on brick or stone walls etc including raking out joints, hacking for keys, scrubbing down with water complete, and material & labour for 15mm thick in two coats (10+5mm) polymer modified ready mix cement based plaster on the wall surfaces complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including material and labour for preparation for applying two coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resisitance as per IS 15489:2004, alkali & fungal rsistance, dirt resistance exterior paint of required shades(Company Depot Tinted) with silicon additives @ 1.43 litre/10sqm over & including priming coat of extreior primer applied @ 0.90 litre/10 sqm including exterior wall care putty over new surfaces Note: The thickness of plaster specified above is minimum thickness and the quoted rates shall also deemd to be include for the provosion of dubbing of the surface and nothing extra shall be payable on this account. and applying all as specified including necessary scaffolding and safety arrangement
Taking down cement or cement lime plaster on brick or stone walls etc including raking out joints, hacking for keys, scrubbing down with water complete, and material & labour for 10mm thick polymer modified ready mix cement based plaster on the wall surfaces complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including material and labour for preparation of new palstered surfaces of walls, preparation for distempering and applying two coat of oilbound distemper over a coat of primer including stopping of nails holes,cracks etc and 1 mm thick (minimum) white cement based wall care putty on new surfaces of walls etc, finishing even and smooth, complete all as specified and directed. Note: The thickness of plaster specified above is minimum thickness and the quoted rates shall also deemd to be include for the provosion of dubbing of the surface and nothing extra shall be payable on this account. and applying all as specified including necessary scaffolding and safety arrangement
Taking down cement or cement lime plaster on concrete surfaces etc including raking out joints, hacking for keys, scrubbing down with water complete, and material & labour for 5mm thick polymer modified ready mix cement based plaster on the ceiling surfaces complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including material and labour Preparation of new plastered surfaces on ceiling and applying three coat of white wash complete all as specified. and directed. Note: The thickness of plaster specified above is minimum thickness and the quoted rates shall also deemd to be include for the provision of dubbing of the surface and nothing extra shall be payable on this account.and applying all as specified including necessary scaffolding and safety arrangement
M&L for Complete removal of existing treatment preparation for applying applying two coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resisitance as per IS 15489:2004, alkali & fungal rsistance, dirt resistance exterior paint of required shades(Company Depot Tinted) with silicon additives @ 1.43 litre/10sqm over & including priming coat of extreior primer applied @ 0.90 litre/10 sqm over old surfaces
M&L for complete removal of existing treatment by washing, rubbing down and stopping of old decorated surfaces on walls, preparation for distempering and applying two coat of oilbound distemper over a coat of primer including stopping of nails holes,cracks etc and levelling with minimum 1 mm thick white cement based wall care putty for obtaining plain surface complete all as specified and directed.
M&L for forming V grooves in plaster n exc 5 mm deep and n exc 5 mm on face and filling cracks with crack X paste of M/s Dr fixit or with equivalent of M/s STP Ltd including necessary scaffolding
M&L for structural repairs to columns, beams, slabs and chajjas at maximum height of 16 mts including scaffolding and safety arrangements completely all as specified and directed by Engineer-in-charge in following steps as mentioned below 1) Chipping , Removing,Carefullly Loose Concrete work by low impact Hammer/Breakar without damaging the structure & cleaning and disposal of malba out side the premises etc. complete as directed. Hard concrete should not be removed by force. 2) M&L for cleaning existing reinforcement with wire/ rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of make. "Feovert" of "Krishna Conchem" OR "Roff Rust Cleaner' of 'Pidilite' OR 'Shali Rustoff' of 'STP Ltd', on rebars with time interval of 1 hr between the coats, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.) 3) M&L for Anticorrosive Treatment to Reinforcement using Corroseal - ZR of M/s Krishna Conchem or Epoxy Zinc Primer of M/s. Dr. Fixit by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces, complete all as specified and directed. 4) M&L for Epoxy bond coat of Make Fosroc (NITOBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit OR equivalent of M/s. Krishna Conchem as approved by GE over exposed concrete surfaces prior to application of any type of mortar to ensure bond between old concrete & new concrete by brush application, complete all as specified and directed. 5) M&L for building up the profile of structural members by using polymer modified mortar from M/s. Krishna Conchem (Molith-PMM) OR Polymer mortar HB of Dr Fixit upto 40mm thickness including levelling, profiling etc in two layers, each layer not exceeding 20mm, complete all as specified and directed. 6) M&L for 15mm thick in two coats (10+5mm) polymer modified ready mix cement based plaster on the wall surfaces including finishing the surface of top layer even and smooth complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including material and labour for preparation for applying applying two coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resisitance as per IS 15489:2004, alkali & fungal rsistance, dirt resistance exterior paint of required shades(Company Depot Tinted) with silicon additives @ 1.43 litre/10sqm over & including priming coat of extreior primer applied @ 0.90 litre/10 sqm over new surfaces
M&L for structural repairs to columns, beams, slabs and chajjas at maximum height of 8 mts including scaffolding and safety arrangements completely all as specified and directed by Engineer-in-charge in following steps as mentioned below 1) Chipping , Removing,Carefullly Loose Concrete work by low impact Hammer/Breakar without damaging the structure & cleaning and disposal of malba out side the premises etc. complete as directed. Hard concrete should not be removed by force. 2) M&L for cleaning existing reinforcement with wire/ rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of make. "Feovert" of "Krishna Conchem" OR "Roff Rust Cleaner' of 'Pidilite' OR 'Shali Rustoff' of 'STP Ltd', on rebars with time interval of 1 hr between the coats, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.) 3) M&L for Anticorrosive Treatment to Reinforcement using Corroseal - ZR of M/s Krishna Conchem or Epoxy Zinc Primer of M/s. Dr. Fixit by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces, complete all as specified and directed. 4) M&L for Epoxy bond coat of Make Fosroc (NITOBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit OR equivalent of M/s. Krishna Conchem as approved by GE over exposed concrete surfaces prior to application of any type of mortar to ensure bond between old concrete & new concrete by brush application, complete all as specified and directed. 5) M&L for building up the profile of structural members by using polymer modified mortar from M/s. Krishna Conchem (Molith-PMM) OR Polymer mortar HB of Dr Fixit upto 40mm thickness including levelling, profiling etc in two layers, each layer not exceeding 20mm, complete all as specified and directed. 6) M&L for rendering 10mm thick polymer modified ready mix cement based plaster on the wall surfaces including finishing the surface of top layer even and smooth complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including material and labour for preparation of new plastered surfaces on walls, preparation for distempering and applying two coat of oilbound distemper over a coat of primer including stopping of nails holes,cracks etc and 1 mm thick (minimum) white cement based wall care putty on new surfaces of walls etc, finished even and smooth, complete all as specified and directed.
M&L for structural repairs to columns, beams, slabs and chajjas at maximum height of 8 mts including scaffolding and safety arrangements completely all as specified and directed by Engineer-in-charge in following steps as mentioned below 1) Chipping , Removing,Carefullly Loose Concrete work by low impact Hammer/Breakar without damaging the structure & cleaning and disposal of malba out side the premises etc. complete as directed. Hard concrete should not be removed by force. 2) M&L for cleaning existing reinforcement with wire/ rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of make. "Feovert" of "Krishna Conchem" OR "Roff Rust Cleaner' of 'Pidilite' OR 'Shali Rustoff' of 'STP Ltd', on rebars with time interval of 1 hr between the coats, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.) 3) M&L for Anticorrosive Treatment to Reinforcement using Corroseal - ZR of M/s Krishna Conchem or Epoxy Zinc Primer of M/s. Dr. Fixit by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces, complete all as specified and directed. 4) M&L for Epoxy bond coat of Make Fosroc (NITOBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit OR equivalent of M/s. Krishna Conchem as approved by GE over exposed concrete surfaces prior to application of any type of mortar to ensure bond between old concrete & new concrete by brush application, complete all as specified and directed. 5) M&L for building up the profile of structural members by using polymer modified mortar from M/s. Krishna Conchem (Molith-PMM) OR Polymer mortar HB of Dr Fixit upto 40mm thickness including levelling, profiling etc in two layers, each layer not exceeding 20mm, complete all as specified and directed. 6) M&L for 5mm thick polymer modified ready mix cement based plaster on the wall surfaces including finishing the surface of top layer even and smooth complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including material and labour for preparation of new plastered surfaces and applying three coats of white wash complete all as specified and directed.
M & L for preparation of old steel surfaces of any description over 10cm width or girth & applying one coat of aluminium paint complete all as specified.
S&F in repairs 110 mmPVC (SWR) pipes, single socketed, in any length with rubber ring joints fixed to walls/floor with proper brackets including bends, shoes etc complete all as specified and directed by the Engineer-in-charge
Providing and fixing additional steel bar in various structural elements like column ,beams and Slab etc. including drilling ,bending and fixing the bars tying with preleft binding wires etc.
Demolition of PCC (unreinforced) in ground floor and pavings n.exc 15 CM thick and clearing of outside MD Land premises.
M/L75 mm thick Cement Concrete in sub base of floors type D-2, PCC 1:4:8 ( 40mmgraded aggregate )
M&L for Demolition of stone slab and tiles of any size and description or thickness in floors laid bedded and pointed in any mortar including screed bed. and providing Acid resistant tiles 20mm thick vitreous ceramic, unglazed, set, jointed and pointed in chemical resistant mortar, resin type, in floors
M&L for Demolition of stone slab and tiles of any size and description or thickness in floors laid bedded and pointed in any mortar including screed bed. and providing Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete and other similar situations including Screed bed or bedding layer or mortar 20mm thick for laying floor finishes in CM 1:6 complete all as specified and directed.
M&L for Demolition of stone slab and tiles of any size and description or thickness in floors laid bedded and pointed in any mortar including screed bed. and providing Prepolished Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed including backing coat 10mm thick in CM 1:3.
S&F in repairs standard aluminium section powder coated (minimum thickness of powder coating shall be 50 micron and colour shall be as approved by GE ) as in frame, shutters for doors, window / ventilators, partitions, fixed / openable / sliding or in any pattern, cut to size, jointed with cadmium plated steel screws, including rubber beading or gaskets for fixing glass, provision of hinges, screws, plugs, handle, lock, roller, Nylon ball bearing etc complete all as specified and directed (Aluminium section shall be of make Jindal/Hindalco/ Indalco) Note:- Weight of Aluminium sections as per actual or as per IS or as per manufacturer, whichever is less, shall only be considered for payment. Cost of other items / accessories required for entire completion of the work shall be deemed to be included in the quoted rate. However glass panes and wire cloth shall be measured and paid separately as supply only under respective items.
S&F aluminium anodised Grills of approved design for window / Bolcony ventilators and fixing with F/U channel for window, ventilators, balcony openging in architectual or rectangular type in existing building with C.P. brass/ stainless steel screws @ 200 mm centre to centre, , including drilling as required in RCC sections, complete all as specified and directed. Note: The Grills shall be of Model DG-102/DG-104 of Make Deco or equivalent make as approved by the GE.
M&L for 4.8mm thick Sheet glass, ordinary quality and glazing with oil putty/rubber beading in square/rectangular size as required in each pane for Partition/Door/Window/Ventilator and similar works etc.
Supply and fixing Solar control film 25 micron reflective type (gareware sun control or equivalent) , sticked to glass panes as per instructions of manufacturers
Supply only stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples
S&F in repairs Mild Steel rolling shutters, with out ball bearing, having thickness of laths as 1.25mm as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: but gear operated type with bevel gear box and crank handle including preparation of new steel based surfaces of any description over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide, complete all as specified and directed.
M&L in repairs for Chequered Plates channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment
Surface exacavation n.exc 30cm deep and averaging 15 cm deep and geting out any type of soil
M&L hard core over rammed earth step wise gauge n.exc 63 mm deposited, spread and levelled in layers n.exc 15 cm thick watered and rammed to a true surfaces.
M&L for providing PCC 1:4:8 type D2 (40mm graded aggregate) as sub base 75mm thick
M&L for coloured Parking tiles, heavy duty of size 300x300x10 mm thick, set and jointed in neat cement slurry and pointed in white cement mixed with pigments to match the colour of the tiles, over and including 15mm thick cement mortar screed bed in CM 1:6, complete all as specified and directed. Make : JOHNS0N /SOMANI/ORIENT BELL/KAJARIA.
M&L for Cement concrete in C1 type (1:3:6) using 20mm graded stone aggregate as in plinth protection and finished even and smooth with using extra cement.
M&L for Filleting in any position and to any shape in in cement mortar 1:3 including all mitres, stops, etc Section of fillet Exc. 25 but n exc. 50 sq. cm
M&L for Providing waterproofing treatment as specified below and at any height of roof surface including removal of watertank, plumbing line during waterproofing making good if any holes and refixing the same as directed by Accepting officer and Engineer in charge complete 1) Dismantling completely existing roof treatment (excluding cement screed bed ) including loosened cement plaster and exposing the top surface of RCC slab and making good the same in CM 1:4 and removing rubbish, etc outside MD land complete all as specified and directed by the Engineer-in-charge 2) M&L for averaging 50 mm thick PCC 1:2:4, type -B-1, using 20mm graded stone aggregated as in padding concrete of roof mixed with WPC in the proportion as recommanded by the manufacturer(s), complete all as specified and directed, 3) M&L 10 mm thick Screed bed or bedding layer in CM (1:3) with WPC when the concrete is still green complete all as specified and directed. 4) M & L for APP modified roof treatment over existing roof slab etc to be executed through approved authorised applicator of the membrane manufacturer with the following specifications complete all as specified and directed:- (a). The roof surface shall be throughly wire brushed cleaned to eliminate all sharp projection, washed dried upto and cleaned overall foreign material and dust to receive primer. (b). The dry surface shall be primed with Torch shield primer as per manufacturer’s instructions, manufactured by the same agency as that of APP membrane. (c). Providing and laying APP modified polyester reinforced water proofing membrane with minimum weight of 3.5 Kg/Sqm, as specified here-in-before. (d). The APP membrane shall be laid using torch-on butane application with minimum 10 cm side overlap and 15 cm end overlap. The laying of membrane shall be got done through an authorised applicator of manufacturer of the membrane. (e). The APP membrane shall be taken up to minimum 200 mm on vertical surfaces. The edge of the membrane shall be fixed with termination bar and fasteners and end shall be properly sealed with sealant. (f) The top of App membrance should be applied two coats of aluminium paint completely all as specified and as directed by Engineer in charge.
M & L ciruit wiring with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 1.5 sqmm drawn in and including PVC conduit 20mm with 1.5 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete including PVC casing caping ISI marked surface wiring inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, sadles, pipe hooks etc fixed properly including taking down old unserviceable sub main wiring complete all as specified and directed. Make of conduit :- Sudhakar/ Precision/ Diamond, Make of wire :- Finolex/ Havells/ Polycab/ KEI Circuit wiring will be made in Hangers/Sheds, hight up to 10 Meters only.
M & L for point wiring with PVC insulated FRLS unsheathed 1100 Volts grade single core multistranded copper conductor cable 1.5 Sqmm drawn in and including PVC casing-caping and accessories, fixed on wall / ceiling etc in repairs with necessary fixing accessories and earth continuity conductor cable of 1.5 Sqmm size connected to common earth and earth dolly including 2 mm thick pressed steel terminal boxes concealed in wall covered with laminated sheet top cover 3 mm thick for mounting switches / sockets / fan regulators fixed with Cadmium plated machine screws complete including taking down old worn out wiring, switch, socket and fittings all as specified for one light / fan / bell point controlled by one switch. Make of Casing caping :- Sudhakar/ Precision/ Pressfit, Make of wire :- Finolex/ Havells/ Polycab/ KEI
-Ditto- all as per item No 34.00 Above but for one 5A 2pin/3pin switch socket out let multipurpose on independent Board.
All as per item No. 34.00 above but wiring complete with 2.5 Sqmm for 3 pin 15A socket multipurpose on independent board
M & L for point wiring with PVC insulated unsheathed single core multistranded copper conductor 1.5 sqmm, 1100Volts grade cable, FRLS, passing through concealed in PVC conduit including accessories and provision of PVC modular boxes for mounting switches, switch socket, fan regulator etc, as directed by Engineer-in-Charge including one run of PVC insulated unsheathed multistranded copper conductor cable 1.5 sqmm (green colour) earth wire and connected to earth dolly and taking down old unserviceable wiring and fixtures such as light, fan, socket ceiling. Make of Cable : Havells/Finolex/L & T/Anchor/Polycab/Benlo Make of Casing Capping : Poly Plast/Pressfit/Presto Plast Note : Circuit conductor from MCB DB to Switch boards should not be less than 2.5 sqmm.
Ditto all as per item No: 37.00 above but One light/Exhaust/Ceiling fan point controlled by one switch including taking down old unserviceable any complete.
Ditto all as per item No: 37.00 above but One 3 pin switch socket combination 5 Amps on the same board with other switches including taking down old unserviceable any complete.
Ditto all as per item No: 37.00 above but One 3 pin switch socket combination 5 Amps, independent including taking down old unserviceable any complete.
All as per item No. 37.00 here in before but with 2.5 Sqmm copper conductor with 2.5 Sqmm cable for earth conductor for one 3 pin 15 Amps socket outlet controlled by one switch. Separate circuit shall be drawn from MCB. No taping from light circuit.
S&F Switch Piano , one way, flush type, 5 Amps, 230 Volts ISI marked complete all as specified and directed. Make : Anchor/ Leader/ Maru/ Crabtree/ Vinay.
S&F Switch Socket combination 2 in 1 , 5 Amps, flush type, 5 Pin, 230 Volts ISI marked, complete all as specified and directed. Make : Anchor/ Leader/ Maru/ Crabtree/ Vinay.
S&F Switch Socket combination 2 in 1 , 5/15 Amps, flush type, 6 Pin, 230 Volts ISI marked complete all as specified and directed. Make : Anchor/ Leader/ Maru/ Crabtree/ Vinay.
Supply & Fix electronic regulator Step type 2 module (5 Position) type 230V, 50 Hz suitable for ceiling fan complete all as specified and directed. Make : Anchor/ Leader/ Maru/ Crabtree/ Vinay.
S&F ceiling rose three terminal, 230 Volts ISI marked PVC / Polycarbonate body, complete all as specified and directed. Make : Anchor/ Leader/ Maru/ Crabtree/ Vinay.
Supply & Fix LED betten plastic type fitting of capacity 20W, operating on 230V, 50Hz, AC Supply having luminous efficacy of not less than 100 lumens/watts, CCT 6500K, P.F>0.9, 2.5 KV surge protection, 4-feet long, housing made out of engineering plastic with decorative end caps elegently designed complete all as specified. Make :-BAJAJ/ JAGUAR/ WIPRO/ CROMPTON.
Ditto- all same as per items No 47.00 above but 10 Watt capacity, 2- feet long complete all as specified. Make :-BAJAJ/ JAGUAR/ WIPRO/ CROMPTON.
S & F MCB DB, 12 way, SPN, double door, 240 Volts and including cutting chases in wall, concealing DB in wall, making good the disturbed surfaces and making all connections complete all as specified and directed. Make: Indo Asian/ ABB/ Havells/ Standard Note: Quoted rate shall be deemed to include for provision of copper bus bar of 200 Amps rating.
S & F MCB, SP, 05 to 32 Amps, 240 Volts, 10 KA Breaking capacity, C-series, complete all as specified and directed. Make: Indo Asian/ ABB/ Havells/ Standard
S & F MCB SPN 40 Amps, 240 / 415 Volts, 50 Hz, 10 KA Breaking capacity, C-series, complete all as specified and directed. Make: Indo Asian/ ABB/ Havells/ Standard
Supply and fix decorative recessed type LED light fitting 36 watt (size 2'x2'), operating on 230V, 50Hz and including driver unit, including provision of 3 core copper flexible cable 1.5 Sqmm from ceiling rose to connector, including making addition/altn to existing false ceiling and providing of false ceiling sheets, aluminium frames including fixing arrangements complete etc. Make :-BAJAJ/ JAGUAR/ WIPRO/ CROMPTON
Taking down LED light fitting 36 Watt (size 2'x2) from roof /wall and repairing & refixing the same at directed place incl replacement of three core 0.5 Sqmm copper conductor & flexible wire/cable complete.
Taking down in repairs old unserviceable Wall Mounted fan 450mm sweep by disconnecting the electric power supply, unscrewing the bolts and nuts, removing the blades and transporting to workshop to undertake repairs by rewinding of burnt out winding using suitable gauge copper wire, replalcement of worn out bearing including scrapping of old paint and applying two coats of synthetic enamelled white paint over a coat of red oxide primer complete and refixing back at site complete all as directed.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300 mm sweep with, blades, and frame and louvers complete all as specified and directed. Make :- ALMONARD / ORIENT
Supply & fix exhaust fans AC single phase 230/ 240 V of size 450 mm sweep with louver. Make : Bajaj/Crompton/Orient/Almonard
Supply & fix fans ceiling complete with electronic type regulator and accessories 230 V,1200 mm sweep. BEE 5 star rated Make : Bajaj/Usha/Orient
Supply and fixing ceiling fans complete with blades, down rods accessories etc operating with electronic regulator on 230 V, 1200 mm sweep. Min air delivery 210 CFM full load wattage 26 to 32 watts, High Speed conforming to IS 374 :2019, colour white BEE 5 star rated with brushless direct current motor (BLDC) without remote complete including taking down old unserviceable fan to MES store all as directed by Engr-in-Charge. Make : BAJAJ (Model : ENERGOS 28) / ORIENT (I FALCON) Note : Unserviceable ceiling fans shall be deposit to MES store.
Taking down of existing ceiling Diffuser and re-fixing of the same by spray painting of ceiling Diffuser with two coats of synthetic enamel paint of white color, after preparation of surfaces, complete all as specified and directed. Note : Any changes in AC duct opening which may take place after false ceiling work is to be modified and rate shall be inclusive in the quoted rate.
Supply and Fix in repairs MCCB 125 Amps 4 pole, 415 Volt in Sheet Metal Enclosure in open construction, panel mounted 0n wall with base plate for mounting in panel, including taking down of old MCCB with enclosure and reconnecting the cabes with proper glands. Make: Indo Asian/ ABB/ Havells/ Standard
Supply and fix in repair MCCB 100 Amp 4Pole 415 Volt 25KA with and including CRCA powder coated 2mm thick enclosure with front openable door wall mounted type with chequred base plate for cable entry,including taking down of old MCCB of any size and reconnecting the cable with proper gland
M & L for Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers all as shown in Electrical Plate No.3 connected to earthing test point all as specified or indicated including testing on completion.
S & F in replace with new modular switch, 1 module, single pole one way 6Amp.
S & F in replace with new modular switch, 1 module, single pole one way 16Amp.
S & F in replace with new modular socket 2/5 pin, 2 module, 6A, ISI marked, 230 volts. Make : Anchor (Roma)/Havells/Crabtree
S & F in replace with new Socket 6/16A, 6 pin, 2 module, ISI marked, 240 Volts, all as specified. Make : Anchor (Roma)/Havells/Crabtree
S & F in replace with new modular stepped type fan regulator, 2 module, single pole one way. 230 volts ISI marked and connecting up complete. Make : Anchor (Roma)/Havells
S & Fin replace with ceiling rose surface bakelite 65x50 mm with 3 terminals.
Taking out old wooden/PVC board and disconnecting all electric connection from switches, board and S & F modular metal flush box 8 module for mounting of modular switches and blank plate. Make : Anchor (Roma)/Havells/Crabtree
All as per Item No- 69.00 above but of modular metal flush box, 6 module.
All as per Item No- 69.00 above but of modular metal flush box, 3 module.
All as per Item No- 69.00 above but of modular metal flush box, 1/2 module.
S&F modular white cover plate with frame, 8 module.
S&F modular white cover plate with frame, 6 module.
S&F modular white cover plate with frame, 3 module.
S&F modular white cover plate with frame, 1 or 2 module.
Taking down unserviceable FTL and supply and fix Slim LED intigrated batten of 20Watt 4ft coolday light with powder coated CRCA decorative patti prewired complete with two Nos of PVC box of size 75x75x20mm for mounting light fittings including new ceiling rose with earth terminal connection, 3 terminal/ PVC/ polycarbonate, isolated body of size 60x20mm complete. Make : Bajaj/Jaquar/Wipro
Taking out old unserviceable old DB and S & F MCB DB SPN confirming to IP 43-IK 09 with acrylic door, 8 way complete with din rail, Neutral and Earthing bar complete and making good the disturbed surfaces.
Taking out old unserviceable old DB and S & F MCB SPN, 10 to 25Amp, 10KA, 230Volt.
Taking out old unserviceable old DB and S & F MCB, single pole, upto 20Amp, 10KA, 230Volt. Make : Anchor/Indoasian/L&T/Wipro
Taking down unsv sub main and M&L for submain wiring in PVC conduit using 2 runs of 6 sqmm PVC insulated stranded copper conductor, single core, FRLS incl single run of 6 sqmm stranded conductor as earth wire all as specified and as directed by Engr- in-Charge. Make of cable: Finolex/L&T/Havells/Anchor/Polycab/Benlo.
M&L for overhauling of ceiling fan any size and Make, dismantling parts, properly cleaning/removing old existing grease oil and applying new oil grease, varnishing of winding, cleaning dust rust and assembling and connecting complete with copper conductor multi stranded 3 core wire of size 14/0.0076, and testing after refixing at site complete all as specified and as directed by Engr-in-Charge. Note: Canopy, bushes, bearing cap and down rod measured and paid separately.
M&L for overhauling of Exhaust fan any size and Make, dismantling parts, properly cleaning/removing old existing grease, oil and applying new oil grease, varnishing for winding, cleaning dust, rust and replacing petty items with new as required such as Nuts, Bolts, washers, bushes, ball bearing, cap, fan shaft, rotor, capacitor 2.5/4 Mfd, body cover etc and reassembling, connecting with copper conductor multi stranded 3 core wire of size 14/0.0076 complete and testing after refixing at site. Note: Rate of petty items to be replace shall be included in quoted rate.
Taking down of existing fuel tank of any size any capacity and re-fixing of the same including Connect to DG set and connected through piping , after preparation of surfaces, complete all as specified and directed.
M & L for Cutting holes into or through brick walls built in cement mortar for fixing the Exhaust fan and making good the distrubed surfaces in cement mortar 1:3 complete all as specified and directed.
Taking down old existing LT panel and re-fxing of the same including LT panel of any size with all accessories and fixing it to other location as directed by Engr-in-Charge at site, connecting cable connection with connecting accessories, incl foundation in PCC 1:3:6 type C2 all as specified and directed.
S&F in replace with new cable PVC insulated three core over all PVC sheathed 2.5 Sqmm stranded copper conductor cable for connecion from DB to connector junction box for power supply to security light fittings drawn in PVC cashing capping or PVC conduit not less than 20mm as required at site and as directed by Engineer-in-Charge including taking out old one.. Make of wire - Polycab/Plaza/Finolex/ Havells/L&T.
S & F junction box of size not less than 4x4 inch with connector encloser, 3 terminal/ PVC/ polycarbonate, isolated body including taking out old one.
S&F building security light bracket bend to shape made as required of 25/32mm dia, GI pipe light grade fixed to pole/ Wall including M&L for fixing with the help of flat iron clamp with the help of nuts and bolts for fixing of building security light fitting on the wall complete after taking out old U/S one all as specified and as directed.
Taking out Old, U/s one Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. Make : Bajaj/Wipro/Jaquar Note : A sum of Rs. 43,749.00 towards sch of credit shall be deducted to arrive the contract sum.
mp construction co
M/S VISHRANTA CONSTRUCTION
Anjali Constructions
AISHWARYA ENTERPRISES
M/s Mohd Altaf Hanif Qureshi
H R ENGINEERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .