Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.1 LAccepted-AOC 15 401 PREM JOT COMPLEX ANIKET CO OP HSG SOC LTD NEAR INDIAN OIL NAGAR GHATKOPAR MANKHURD LINK ROAD GOVANDI CHEMBUR W MUMBAI 400043 | MUMBAI | MUMBAI | MAHARASHTRA | 400043 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹35.3 L+₹23,900 (0.68%)Rejected-Finance 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | L2 | Rejected-Finance REJECTED BEING NOT LOWEST | |
| 3 | L3₹49.6 L+₹14.5 L (41.3%)Rejected-Finance BLOCK C 14 GROUND FLOOR PLOT 618 624 BHIVANDIWALA TERRACE JAGANNATH SHANKARSHETH MARG DHOBI TALAO NEAR KALBADEVI POST OFFICE MUMBAI 400002 | MUMBAI | MAHARASHTRA | 400002 | L3 | Rejected-Finance REJECTED BEING NOT LOWEST |
Tender Value
₹41.8 L
EMD Value
₹84,000
Closing Date
18 Feb 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
COL S P SINGH
CWE AF LOHEGAON, PUNE - 411032
ENHANCEMENT OF POWER SUPPLY AT SITE I AND SITE II WITH ASSOCIATED WORKS AT AF STN KANHERI HILLS UNDER GE AF THANE
2025_MES_694556_1
82682/E8
Open Tender
Civil Works
Item Rate
180 days
GE AF THANE
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE AF THANE
₹84,000
Yes
23 May 2025
23 Jan 2025
20 Feb 2025
23 Jan 2025
18 Feb 2025
6 Feb 2025
Amount
Supply, install , testing and commissioning of Indoor transformer as per IS : 1180 part - I up to date, EEL-2 step down, copper Cu 99.9% purity, electrolytic grade wound 22KV/433 Volts (at no load) AC 3 phase 50 Hz 315 KVA capacity, core type, oil immersed naturally air cooled, oil natural air natural (ON/AN) , with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector group DYn-11 with neutral brought out on secondry side (LV) and having taping at +5% to -10% in steps of 2.5% on HV side to be changed by means of hand operated off load tap changer gear. The maximum temperature rise should not exceed 50 degree celsius in oil and 55 degree celsius in HV/LV winding when measured by resistance method after continuous full load run on an ambient temp of 40 degree celsius transformer shall be of BOLTLESS core design. Transformer shall be double wound, core type with low loss, non ageing, high permeability CRGO prime core grade M-OH / ZDKH /TCH grade, perfectly insulated and clamped to minimize noise and vibrations. The transformer shall be IS/IEC 60076 and as per IS-1180 part - I of 2014 marked. Flux Density at rated voltage and rated frequency should be 1.688 T the transformer shall be designed as per CBIP manual 317 for over-fluxing witstand capacity of 110% continuous, 125% for 1 minute and 140% for 5 seconds. and over loading capacity of transformer shall be as per 6600 , Noise level as per NEMA TR1, with class A insulation, Tank pressure, Vaccum witstand capability & minimum clearances as per CBIP manual, No Load Current within 1% to 2% of Full load current Tranformer losses shall not exceed the loses mentioned in Table 6 of IS: 1180 of 2014 Part - I with Energy Effeciency Level - 2 and shall comprise of the following accessories :-
(a) One cable box on HT side (Primary side) consisting of three nos porcelain bushing with copper rods, complete with nuts and washer , with cable glands suitable for reception/taking out 3 core 95 Sqmm, HT 22000 volts grade, XLPE insulated and PVC sheathed, heavy duty , armoured cables including jointing materials complete. (b) One cable box on LT side(secondary side) consisting of four nos porcelain bushing with copper rods, complete with nuts and washers, with cable glands suitable for reception/taking out single core /3.5 core of rated size/ runs of secondary currents, LT 1100 volts grade, PVC/XLPE insulated and PVC sheathed, heavy duty, armoured cables including jointing materials complete. with Bi metallic flexible connectors and copper bus bars of rated capacity with insulators support to be provided (c) Conservator with filter type drain valve and oil level guage. (d) De-hydrating breather with first fill of dehydrating agent (Silica Gel). (e) Explosive vent, Thermometer pocket on tank cover, oil level guage, Oil drain filter valve, Jacking / Lifting lugs, Marshalling Box,IP 55, with oil filling hole with cap/plug with connection plate complete, Air release valve plug and four nos plain solid cast steel detachable rollers. (f) One no 100 mm dia, dial type thermometer, vapour pressure type, having range 0-120 degree celsius with metal guard having maximum perimeter temperature reading indicator with re-setting device. (g) Two earthing terminals on tank cover to facilitate fixing of 50x6mm galvanised iron earth strip for earthing of body. (h) Rating plate and terminal marking plate. (j) Extra bushing for neutral in the LT cable box for providing independent set of earthing for neutral.
(e) OEM should be BIS and BEE certified for all the ratings of the transformer that are to be submitted. (f) Rate quoted includes the cost of making and Testing of controll wiring connection at the Transformer and RMU/VCB for the Temperature alarm/Trip, Gas alarm/Trip. And the Controll cable shall be measured and paid seperatly under relevent item (g) Expenses / cost for FAT and necessary Travel / freight / conveyance / stay expenses for inspecting/ testing officers as nominated by the accepting Officer for FAT shall be included in the rate quoted. Tender/ contractor shall submit all the necessary certificates as mentioned in above note (a) to (e) from the OEM of transformer during Technical Bid for evalution. And fauilure of submission/ Upload of the certificates during T bid shall be Non Bonafide.
Supply & install ,testing and commissioning of Indoor/Outdoor transformer as per IS : 1180 part - I up to date, EEL-2 step up, copper Cu 99.9% purity, electrolytic grade wound 433/22 KV Volts (at no load) AC 3 phase 50 Hz 315 KVA capacity, core type, oil immersed naturally air cooled, oil natural air natural (ON/AN) , with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector group DYn-11 with neutral brought out on secondry side (LV) and having taping at +5% to -10% in steps of 2.5% on HV side to be changed by means of hand operated off load tap changer gear. The maximum temperature rise should not exceed 50 degree celsius in oil and 55 degree celsius in HV/LV winding when measured by resistance method after continuous full load run on an ambient temp of 40 degree celsius transformer shall be of BOLTLESS core design. Transformer shall be double wound, core type with low loss, non ageing, high permeability CRGO prime core grade M-OH / ZDKH /TCH grade, perfectly insulated and clamped to minimize noise and vibrations. The transformer shall be IS/IEC 60076 and as per IS-1180 part - I of 2014 marked. Flux Density at rated voltage and rated frequency should be 1.688 T the transformer shall be designed as per CBIP manual 317 for over-fluxing witstand capacity of 110% continuous, 125% for 1 minute and 140% for 5 seconds. and over loading capacity of transformer shall be as per 6600 , Noise level as per NEMA TR1, with class A insulation, Tank pressure, Vaccum witstand capability & minimum clearances as per CBIP manual, No Load Current within 1% to 2% of Full load current Tranformer losses shall not exceed the loses mentioned in Table 6 of IS: 1180 of 2014 Part - I with Energy Effeciency Level - 2 and shall comprise of the following accessories :-
(a) One cable box on HT side (Primary side) consisting of three nos porcelain bushing with copper rods, complete with nuts and washer , with cable glands suitable for reception/taking out 3 core 95 Sqmm, HT 22000 volts grade, XLPE insulated and PVC sheathed, heavy duty , armoured cables including jointing materials complete. (b) One cable box on LT side(secondary side) consisting of four nos porcelain bushing with copper rods, complete with nuts and washers, with cable glands suitable for reception/taking out single core /3.5 core of rated size/ runs of secondary currents, LT 1100 volts grade, PVC/XLPE insulated and PVC sheathed, heavy duty, armoured cables including jointing materials complete. with Bi metallic flexible connectors and copper bus bars of rated capacity with insulators support to be provided (c) Conservator with filter type drain valve and oil level guage. (d) De-hydrating breather with first fill of dehydrating agent (Silica Gel). (e) Explosive vent, Thermometer pocket on tank cover, oil level guage, Oil drain filter valve, Jacking / Lifting lugs, Marshalling Box,IP 55, with oil filling hole with cap/plug with connection plate complete, Air release valve plug and four nos plain solid cast steel detachable rollers. (f) One no 100 mm dia, dial type thermometer, vapour pressure type, having range 0-120 degree celsius with metal guard having maximum perimeter temperature reading indicator with re-setting device. (g) Two earthing terminals on tank cover to facilitate fixing of 50x6mm galvanised iron earth strip for earthing of body. (h) Rating plate and terminal marking plate. (j) Extra bushing for neutral in the LT cable box for providing independent set of earthing for neutral.
(e) OEM should be BIS and BEE certified for all the ratings of the transformer that are to be submitted. (f) Rate quoted includes the cost of making and Testing of controll wiring connection at the Transformer and RMU/VCB for the Temperature alarm/Trip, Gas alarm/Trip. And the Controll cable shall be measured and paid seperatly under relevent item (g) Expenses / cost for FAT and necessary Travel / freight / conveyance / stay expenses for inspecting/ testing officers as nominated by the accepting Officer for FAT shall be included in the rate quoted. Tender/ contractor shall submit all the necessary certificates as mentioned in above note (a) to (e) from the OEM of transformer during Technical Bid for evalution. And fauilure of submission/ Upload of the certificates during T bid shall be Non Bonafide.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 22000 volts grade, of size 3 core 120 sq mm.
Supply and fix cable jointing kit for 22 KV grade cable for in door termination, heat shrink type, joint complete with jointing material and accessories suitable for3 core XLPE, armoured, Al conductor cable of size 70 to 120 sq mm.
Supply and fix cable jointing kit for 22 KV grade cable for out door termination, heat shrink type, joint complete with jointing material and accessories suitable for3 core XLPE, armoured, Al conductor cable of size 70 to 120 sq mm.
M & L for construction of platform for installation of transformer of size 3000x2500x1500mm complete all as specified
S & F MCCB 4 Pole, 415 V, Adjustable type, 400 Amps with breaking capacity 36 KA
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 400 sq mm 3.5 core
Material and labour in repairs for earthing complete with copper earth plate electrode 600mmX 600mmX 3.15 mm thick buried directly in ground vertically ( earth pit not less than 2.25 metres deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including copper strip of size 20 X 3 mm from earth electrode to test point or up-to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate no 3 of SSR Part-I provision of G I Pipe 40mm bore eight grade for protection of GI strip and GI watering pipe of 20 mm bore medium grade,GI funnel with wire mesh,including char-coal, salt packed all around the earth electrode plate in layers,PCC earth pit chamber 1:3:6 type C1,RCC cover 1:2:4 type B1,excavation,earth work in any strata and returning filling, removal of surplus soil and testing for required value complete all as specified and directed.
sapana enterprises (BID ID -3237135)
AGRAWAL ASSOCIATES (BID ID -3237174)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .