Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.8 CrAccepted-AOC D 154 D 154 GROUND FLOOR INDUSTRIAL ESTATE PHASE VII MOHALL | ₹10.8 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹12.6 Cr+₹1.7 Cr (16.1%)Rejected-AOC | ₹12.6 Cr+₹1.7 Cr (16.1%) | L2 | Rejected-AOC L2 |
| 3 | Rejected-Technical SHOP NO 9 KHALSA SCHOOL MARKET MODEL TOWN PHAGWARA | - | - | Rejected-Technical reason attached |
| 4 | Rejected-Technical GURDASPUR CITY | - | - | Rejected-Technical reason attached |
Tender Value
₹13.9 Cr
EMD Value
₹27.8 L
Closing Date
21 Apr 2025, 10:00 amClosed
Xen,Kandi Canal Stage2 Division,hoshiarpur
Xen,Kandi Canal Stage2 Division,hoshiarpur
Construction of Electrical Components of Kathgarh Lift Irrigation Scheme Off-taking at RD 38810 Burji of Right Side of Bist Doab Canal
2024_WR_130957_1
07/2024-25
Open Tender
Civil Works - Lift Irrigation Schemes
Item Rate
120 days
Kathgarh
Please refer Tender documents.
2 documents required · 2 mandatory
₹50,000
Yes
₹27.8 L
Yes
Xen,Kandi Canal Stage2 Division,hoshiarpur
9 May 2025
3 Dec 2024
21 Apr 2025
3 Dec 2024
21 Apr 2025
3 Dec 2024
17 Apr 2025
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Electrically driven horizontal split casing pumps for delivering 209 LPS each (950 m3/ hour) raw water against a Head of 85 metre with glass flake coating on inner casing and impellor and coupled on MS fabricated base frame with HT motor (11 KV) including cost of foundation bolts, flexible coupling & coupling guard,tappers & other contingent material fixed in position complete in all respects. Make of Pumps : Mather & Platt / AQUA/ Kirloskar / WPIL/ Grundfos. Make of Motor: Crompton/ABB/ Kirloskar/ Marathon/Siemens | - | Each | - | - |
| 2 | Supplying, installing, testing and commissioning of 11 KV HT panel consisting of (i) Main Incomer 11 KV, 630A, 31.5 KA with other accessories. (ii) Outgoing feeder for HT motors (500 HP) 11 KV, 630A, 31. 5 KA with other accessories (iii)Outgoing termination connections for SubStation transformer (iv) Power cables and termination kits etc
The detail of item is as under: | - | - | - | - |
| 3 | A (i) 11kV DISTRIBUTOR BOARD Supplying, installing, testing and commissioning of Indoor 1no. IC & 4 no. OG Vacuum Circuit Breaker Panel Comprising of 11kV, 630Amp, 31.5kA/1-sec, Draw-Out type HT Vacuum Circuit breaker panel confirming to IEC 62271-200, comprising of 630Amp, busbar should be insulated with full system voltage sleeves, 01no. Service Trolley and 01no. Line-Earthing Facility and surge arrestors of suitable rating. The Board shall consist of following panels: INCOMER PANEL of 1 no. & OUTGOING of 4 nos. same as incomer panel 11kV, 630Amp, Cassette mounted Vacuum Circuit Breaker. Vacuum Circuit Breaker should have 03nos. encapsulated vacuum bottles of same manufacturer as of circuit breaker. Motorized spring charging mechanism with integral spring charging handle for manual spring charge Cast-resin CTs 11kV, 300-150/5-5, Core1: Class 5P10, 7.5VA, Core2: Class 1, 7.5VA Cast resin potential transformers 11kV/rt3:110V/rt3, 50VA, Class 1.0 Accessories like Local Remote Switch, breaker control switch (T-N-C), space heater with thermostat, DC & AC control circuit through MCB, indicating lamps for RYB, spring charge, DC Supply healthy, Breaker ON/OFF and TEST/ SERVICE position Multifunction Meter with RS485 port, Conzerv make Digital Ammeter and Voltmeter Comprehensive Numerical Motor-Protection relay with native IEC61850 protocol for communication having following features like: Protection: OverCurrent + EarthFault Protection, Three-Phase U/OV Protection Control: Circuit Breaker Control, Panel Illumination Lamp Space Heater + Thermostat Electrical or Mechanical Anti pumping Protection Test Terminal Block Operation Counter for VCB 8-Window Annunciation + Hooter Scheme for Alarm/Trip indication. Panel structure fabrication shall be made of sheet steel | - | job | - | - |
| 4 | Voltmeter Comprehensive Numerical Motor-Protection relay with native IEC61850 protocol for communication having following features like: Protection: OverCurrent + EarthFault Protection, Three-Phase U/OV Protection Control: Circuit Breaker Control, Condition Monitoring: CB Condition Monitoring, TCS, Disturbance Recorder, Event Log with date and time SCADA: 4/6 DI/DOs and RJ-45 connectors on front and back for SCADA communication Panel should have additional facilities like Arrangement for connecting atleast one run of outgoing cables. Panel Illumination Lamp Space Heater+ Thermostat Electrical or Mechanical Anti pumping Protection Test Terminal Block Operation Counter for VCB 8-Window Annunciation + Hooter Scheme for Alarm/Trip indication. Safety Shutters with padlocking arrangement Continuous rated closing and tripping coil One Second Fully Internal Arc Type tested for 31.5kA.OUTGOING of 3 nos. same as incomer panel along with changes of function of relay and CT ratio as following : Comprehensive Numerical Motor-Protection relay with KEMA certified native IEC61850 protocol for communication having following features like: Protection: Directional/Non-Directional OC+EF, Three-Phase U/OV Protection, Frequency Protection, Negative Sequence OC Protection, Loss of Load/Stalling/Jamming/Phase Reversal Protection Control: Circuit Breaker Control,Condition Monitoring: CB Condition Monitoring, TCS, Disturbance Recorder, Event Log with date and time B14 Measurement: Current/Voltage/Frequency Measurement SCADA: 4/6 DI/DOs and RJ-45 connectors on front and back for SCADA communication Cast-resin CTs 11kV, 100-50/5-5, Core1: Class 5P10, 7.5VA, Core2: Class 1, 7.5VA 1 INCOMING, 3 FOR MOTORS + 1 SPARE | - | - | - | - |
| 5 | A (ii) Supply, erection, testing & commissioning of HT Shunt Capacitor suitable for raw water pump and motor of 500 H.P mentioned in item 1 for improving power upto 0.9 lagging & as per I.S specifictaion | - | Each | - | - |
| 6 | A (iii) Supplying, installing, testing and commissioning of flux compensated magnetic amplifier (FCMA) type high Voltage soft strater suibale for operation at 11kV, 3 phase, 50 Hz A.C supply and suitable for connection to the phase segregated neutral terminal Box of pump/ motor. | - | Each | - | - |
| 7 | B. Supply, erection, testing & commissioning of 11 KV cable from Main Incomer to panel / Panel to motors/ to substation grade aluminum conductor XLPE 3 core 185 mm2 cable suitable for supplying for 11 KV make make: CCL/ ICL/ FGL/ Havells/ Siemens | - | Mtr | - | - |
| 8 | C. Supplying, erection, testing & commissioning of cable end joints suitable for 185 mm2 type Heat shrinking 3 core XLPE cable with required thimbles of same size .The joint should be strictly as per relevant ISI specifications. | - | Each | - | - |
| 9 | D. Supplying, erection, of earthing strips 50mmx 6mm GI complete in all respects including excavation jointing cutting through walls, riveting etc complete. | - | Mtr | - | - |
| 10 | E. GI wire 8 no. for earthing HT panel and substation including accessories, thimbles etc. | - | Mtr | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
BOQ.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .