SE, ETC-II Kanpur.
SE, ETC-II Kanpur.
FOR DISMANTLING OF 132/33KV 40MNVA T/F AND ERECTION OF NEW 132/33KV 63MVA T/F AT 132KV S/S TALGRAM UNDER ETD-FATEHGARH.
2023_UPTCL_873306_1
E-TENDER NO. 09/ETC-II(K)/2023-24
Open Tender
Electrical Works
Lump-sum
45 days
KANPUR
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,180
Executive Engineer ETD-II Kanpur
₹15,000
12 Mar 2024
22 Dec 2023
16 Jan 2024
22 Dec 2023
8 Jan 2024
22 Dec 2023
Amount
Complete dismantling the accessories of 40 MVA, 132/33 KV Transformer after opening of Jumpers, removal of earthing and opening of cables & cable connection, draining out the transformer oil up to required level in 209 litres capacity oil drums/tanker, removal of all radiators, conservator tank, oil pipe lines all bushings, turrets, fan motors, mashalling box. RTCC panel, HV/LV LA & 33 KV CT (800/400/1) etc with proper gasket along with nuts and bolts to complete the jobs satisfactorily including proper stacking, Blanking plates, nuts and bolts. All T&P required for execution of work shall be arranged by the contractor at his own cost
Shifting of main tank of 40 MVA. 132/33 KV transformer approximate 20 mtrs away from the plinth+ including turning of tank, if required including all T&P and all other works required to complete the job satisfactory as per tech Specn
Additional shifting 1 Job for every 5 Mtr.
Shitting of main tank of New 63 MVA. 132/33 KV transformer from unloading point up to plinth, approximate 20 mtrs distance including turning of tank, if required including all T&P and all other works required to complete the job satisfactory as per tech Specn
Additional shifting 1 Job for every 5 Mtr.
Complete, erection of 63 MVA T/F by erection of radiator, conservator tank, bushing with its turrets (if available) connecting of oil pipe line. erection of cooling fans, making control cables connection of T/F, bucholz relay etc. for completing the work, topping of T/F oil and final oil filling in tank, radiator, conservator tank and all other associates work for completing of work. Work also includes erection of HV/LV LA and 33 KV CT (2000/1250/1A).
Termination of cable in RTCC & marshaling box transformer relay panel if required with the assurance of proper reflection of parameters in the meters, gauges provided on RTCC, OLTC, Marshaling box, transformer etc.
Earthing of main tank of 63 MVA T/F, T/F Neutral bushing HV and LV side, 120 KV LA & 33 KV CT by using M.S. flat 50x6/ 75x10 mm size, its jointing with already laid earth mat / Deltas, neutral bushing support for its earthing work
Placement of new RTCC panel of this new 63 MVA TIF in control room at 132 KV S/S Neebkarori including its Termination & fitting and laying of control cable if required as per site requirement and its connections
Jumpering of 63 MVA T/F from HV with single Moose/Zebra/Panther and LV side with Double Zebra/Moose/Panther complete up to 33 KV Main Bus
Centrifuging of complete T/F oil in T/F by connecting centrifuging pipes circulating th T/F oil through PVT. Centrufuging machine and taking the BDV value of the oil periodically till the required value is achieved. Approx. 25 KL
STRENTHENING OF 33 KV MAIN BUS FROM SINGLE TARANTULLA TO TWIN MOOSE SHALL BE CARRIED OUT AS DETAILED HERE UNDER.
Dismantling of 33 KV Old/ Damaged Main bus bar Sections (R, Y, & B) of Single Tarantulla conductor and lowering down of conductor from sub-station gantry to complete dismantling work including dismantling of all associated Tension clamps, fittings & Disc insulators etc.
Dismantling of Jumpering of 33 KV Equipment, jumper from main bus to 33 KV switchgear, Moose/Panther conductor.
Dismantling of Jumpering of 33 KV Equipment, jumper from Section Isolator to 33 KV switchgear, Moose/Zebra conductor.
Stringing and proper sagging of new 33 KV Main bus bar Sections (R, Y & B) by Twin Moose conductor the work includes fitting of tension clamps, Hoisting of 70 KN Disc, tension fittings, Spacers PG Clamps etc. and cutting of conductor as required.
Jumpering of 33 KV Equipment, jumper from main bus to bus Isolator to 33 KV switchgear to 33 KV CT to LSI of Twin Panther conductor.
Jumpering of 33 KV Equipment, jumper from Section Isolator for Twin Tarantulla Conductor.
Supply
PG Clamp Moose to Moose
PG Clamp Moose to Panther
PG Clamp Panther to Panther
Spacer for 250mm spacing for Twin Moose Conductor 02 bolted complete with hot dip galvanized nut, bolts & washer as per technical specification.
Spacer for 100mm spacing for Twin Moose Conductor 02 bolted complete with hot dip galvanized nut, bolts & washer as per technical specification.
33 KV Circuit Breaker clamp suitable for Twin Moose conductor complete with hot dip galvanized nut, bolts and washer as per technical specification.
33 KV Isolator clamp suitable for Twin Moose conductor one side connecting the Twin Moose conductor and another side a plate with 04 Nos. 12mm dia. hole as per technical specification with HDG nut & Bolt.
33 KV CT clamp suitable for Twin Moose conductor complete with hot dip galvanized nut, bolts and washer as per technical specification with HDG nut & Bolt.
Supply of 33 KV bolted type tension fitting for Twin Moose conductor 1x4 No. disc insulator with turn buckle complete with hardware fitting d-sackle, d-socket, ball hook, yoke plate, d-clip it tension clamp etc. as per technical specification.
Supply of 33 KV bolted type tension fitting for Twin Moose conductor 1x4 No. disc insulator without turn buckle complete with hardware fitting d-sackle, d-socket, ball hook, yoke plate, d-clip it tension clamp etc. as per technical specification.
33 KV Section Isolator clamp suitable for Twin Moose conductor one side connecting the Moose conductor and another side a plate with 04 Nos. 12mm dia. hole as per technical specification with HDG nut & Bolt.
Spacer for 60mm spacing suitable for Twin Panther conductor 01 bolted made of aluminum alloy LM-06 complete with hot dip galvanized nut bolt and washer as per technical specification.
M/s S.S. Refregeration
TAJ ENTERPRISES
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .