Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.0 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹24.3 L+₹25,370 (1.06%)Rejected-Finance BYE PASS DALHOUSIE ROAD PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹24.7 L+₹66,350 (2.76%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
30 Mar 2024, 6:00 pmClosed
GE Satwari
GE Satwari PIN 180003
REPAIR MAINT OF PUMPS, MOTORS, STARTERS, VOLTAGE STABLIZERs ETC AT Y STATION, RIDGE AREA, RAIPUR SATWARI AND 166 MH UNDER AGE EM OF GE SATWARI
2024_MES_644783_1
GEJM-93/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE Satwari
Class D Cat b(i)
9 documents required · 9 mandatory
₹500
Yes
GE Satwari
₹70,000
Yes
10 Sept 2024
1 Mar 2024
1 Apr 2024
2 Mar 2024
30 Mar 2024
16 Mar 2024
2 Mar 2024 - 16 Mar 2024
Amount
Disconnecting the electrical connection from the panel and lifting out unserviceable submersible pump and Motor's of capacity 17.5 HP to 40 HP from the depth of tube well 35Mtr's including column pipe and other accessories carrying to workshop for repair complete all as specified and directed. Note: The cost of transportation from workshop & back and T&P required for taking up submersible pump & motor from borewell is deemed to be included in the quoted rate. (ii) Spare part measured and paid seperatly under relivent items. (iii) The nature of defect accured same in period of CA, there is no extra cost will be initiated. (iv) During the lifting of Pump and motor from the tube well any type happening case rate deemed to be included in the qouted rate.
All as per Srl item No 01 here in before but of Capacity 25 to 30 HP from the depth of tube well upto 150 Mtr's.
All as per Srl item No 01 here in before but of Capacity 7.5 HP from the depth of tube well upto 40 Mtr's.
M & L for Lowering the serviciable submersible pump with Motor's upto depth of tube well 35 Mtr's of capacity 17.5 HP to 40 HP after repair shifted to in its orignal location jointing with column pipe and other accessories connecting to all electrical connection testing and commissioning including replacement of all nut/bolt & washer, gasket with new one and binding the submersible cable with colum pipe etc as required at site complete all as specified and directed by Engineer-in-charge. Note: (i) The cost of transportation from workshop & back and T&P required for lowering of submersible pump with motor to the borewell is deemed to be included in the quoted rate. (ii) During the lowering of Pump and motor to the tube well any type happening case rate deemed to be included in the qouted rate. (iii) Spare parts measured and paid seperatly under relivent items. (iv) The nature of defect accured same during the period of CA, there is no extra cost will be paid to the contractor.
All as per Srl item No 04 here in before but of Capacity 25 to 30HP, the depth of tube well upto 150 Mtr's.
All as per Srl item No 04 here in before but of Capacity 7.5 HP, the depth of tube well upto 40 Mtr's.
M & L for strip opening of submersible motor, taking out roter from stator, taking out burnt winding from the stator cleaning the core and rewinding the same with insulated copper wire of existing gauge including other winding material of Cap up to 7.5 HP complete all as specified and directed by Engr-in Charge. Note: (i) The nature of defect accured same during the period of CA, there is no extra cost will be paid to the contractor.
All as per Srl item No 07 here in before but of size 15 HP to 20 HP
All as per Srl item No 07 here in before but of size 25 HP to 30 HP
All as per Srl item No 07 here in before but of size 35 HP to 40 HP
M & L in replacement of the defactive spare parts of submersible Motor sets are as under complete all as specified and directed by Engineer-in-charge. Note: (i) The nature of defect accured same during the period of CA, there is no extra cost will be paid to the contractor.
Thrust plate of submersible motor 7.5 HP as per existing size.
Thrust plate of submersible motor 17.5 HP as per existing size.
Thrust plate of submersible motor 25 HP to 30 HP as per existing size.
Thrust plate of submersible motor 35 HP to 40 HP as per existing size.
Thrust bearing and base with pad of submersible motor 7.5 HP as per existing size.
Thrust bearing and base with pad of submersible motor 17.5 HP as per existing size.
Thrust bearing and base with pad of submersible motor 25 HP to 30 HP as per existing size.
Thrust bearing and base with pad of submersible motor 35 HP to 40 HP as per existing size.
Rubber bushes for submersible motor 7.5 HP as per existing size.
Rubber bushes for submersible motor 17.5 HP as per existing size.
Rubber bushes for submersible motor 25 HP to 30 HP as per existing size.
Rubber bushes for submersible motor 35 HP to 40 HP as per existing size.
Alignment, grinding, polishing and balancing of shaft for submersible motor 7.5 HP to 17.5 HP as per existing size.
Alignment , grinding, polishing and balancing of shaft for submersible motor 25 HP to 40 HP as per existing size.
Coupling arrangement with key of submersible motor of cap 7.5 HP to 17.5 HP as per existing size.
Coupling arrangement with key of submersible motor of cap 25 HP to 40 HP as per existing size.
Opening, servicing, cleaning the submersible pump sets for repair of various size & capacity in replacement of the defactive spare parts of are as under complete all as specified and directed by Engineer-in-charge:- Note: (i) Spare part measured and paid separatly under relivent items. (ii) The nature of defect accured same during the period of CA, there is no extra cost will be paid to the contractor.
Stainless steel shaft of submersible pump of cap 7.5 HP as per existing size.
Stainless steel shaft of submersible pump of cap 17.5 HP to 40 HP as per existing size.
Impellers for submersible pump set 7.5 HP as per existing size.
Impellers for submersible pump set 17.5 HP to 40 HP as per existing size.
NRV for submersible pump set 17.5 HP to 40 HP as per existing size.
Bowl bush for submersible pump set 7.5 HP as per existing size.
Bowl bush for submersible pump set 17.5 HP to 40 HP as per existing size.
Neck ring for submersible pump set 7.5 HP as per existing size.
Neck ring for submersible pump set 17.5 HP to 40 HP as per existing size.
Sand guard assembely of 25 to 40 HP submersible Motor as existing make and size
Sand guard assembely of 7.5 to 20 HP submersible Motor as existing make and size
Bush housing set including bush of 25 to 40 HP submersible Motor as existing make and size
Bush housing set including bush of 7.5 to 20 HP submersible Motor as existing make and size
Upper housing set of 25 to 40HP submersible Motor as existing make and size
Upper housing set of 7.5 to 20 HP submersible Motor as existing make and size
Lower housing set of 25 to 40 HP submersible Motor as existing make and size
Lower housing set of 7.5 to 20 HP submersible Motor as existing make and size
Seal guide sleeve of 25 to 40 HP submersible Motor as existing make and size
Seal guide sleeve of 7.5 to 20 HP submersible Motor as existing make and size
Cable connector sleeve guide plate of 25 to 40 HP submersible Motor as existing make and size
Cable connector sleeve guide plate of 7.5 to 20 HP submersible Motor as existing make and size
Tie rod & tie bolt of 25 to 40 HP submersible Motor as existing make and size
Tie rod & tie bolt of 7.5 to 20 HP submersible Motor as existing make and size
Motor base along with inner plate of 7.5 to 20 HP submersible Motor as existing make and size
Motor base along with inner plate of 25 to 40 HP submersible Motor as existing make and size
Disconnecting the electrical connection for taking out unserviceable open well submersible motor from any size from the well and other accessories carrying to workshop for repair, after repair open well submirsable motor shifted to the existing well and re installation in orignal position including all electrical connection testing and commissioning complete all as specified and directed. Note: . (i) The cost of transportation to and from workshop is deemed to be included in the quoted rate. (ii) The nature of defect accured same during the period of CA, there is no extra cost will be paid to the contractor.
M & L for removing the burnt winding wire of the open well submersible motor cleaning the slots for rewinding, and rewinding the motor with super enamelled copper winding wire superior quality as per exisitng gauge and size, varnishing, drying, replacement of bearings and assembling the motor of Cap up to 5 HP complete all as specified and directed. Note: (i) The nature of defect accured same during the period of CA, there is no extra cost will be paid to the contractor.
Taking down from the open well of submersible pump, repair/Opening & overhauling, servicing and cleaning and replacement the defactive part of open well submersible pump Set are as under:- Note: (i) Spare part measured and paid separatly under relivent items. (ii) The nature of defect accured same during the period of CA, there is no extra cost will be paid to the contractor.
Replacement of neck ring of existing size as directed by Engr-in-Charge
Replacement of Impellers of existing size as directed by Engr-in-Charge
Replacement of thrust bearing of existing size as directed by Engr-in-Charge
Replacement of rubber bush as directed by Engr-in-Charge
Supply and fix in replacement of MS Column pipe heavy grade as per IS inside the bore well to header of size 50 mm including both side flange ended welded in every three mtr along with nut bolt and Washer alongwith gasket incl painting complete all as directed by Engr-in-charge.
Supply and fix in replacement of MS Column pipe heavy grade as per IS inside the bore well to header of size 80 mm including both side flange ended welded in every three mtr along with nut bolt and Washer alongwith gasket including painting with primer complete all as directed by Engr-in-charge.
Supply and fix in replacement of MS Column pipe heavy grade as per latest IS inside the bore well to header of size 100 mm including both side flange ended welded in every three mtr along with nut bolt and Washer alongwith gasket including painting with primer complete all as directed by Engr-in-charge.
Supply and fix in replacement of MS Column pipe heavy grade as per IS inside the bore well to header of size 150 mm including both side flange ended welded in every three mtr along with nut bolt and Washer alongwith gasket including painting with primer complete all as directed by Engr-in-charge.
Disconnecting the electrical connection from the panel and taking out unserviceable VT Motor any size from the foundation of bore well and other accessories carrying to workshop for repair, after repair VT Motor shifted to the existing bore well and re installation in orignal position including all electrical connection testing and commissioning complete all as specified and directed. Note: (i) Spare part measured and paid separatly under relivent items. (ii) The cost of transportation to and from workshop is deemed to be included in the quoted rate. (iii) The nature of defect accured same in defect liability period, there is no extra cost will be initiated.
M & L for removing the burnt winding wire of the VT motor, cleaning the slots for rewinding, and rewinding the motor with super enamelled copper winding wire superior quality as per exisitng gauge and size, varnishing, drying, same replacement of bushes and any other spare parts required replacement of bearings and assembling the motor of Cap 35 to 40 HP re-assembling, re-installing at site connecting and testing complete all as specified and directed. Note: (i) The nature of defect accured same in defect liability period, there is no extra cost will be initiated.
All as per Srl item No 66 here in before but of Capacity 30 HP
Disconnecting the electrical connection from the panel and VT motor to the pump set and lifting of unserviceable VT pump any capacity from the bore well upto 40 Mtr's including column pipe and other accessories carrying to workshop for repair, after repair of VT pump Lowering, jointing the same orignal position/location with column pipe, motor and other accessories connecting to all electrical connection testing and commissioning including replacement of all new nut/bolt & washer, gasket etc as required at site complete all as specified and directed by Engineer-in-charge. Note: (i) The cost of transportation from workshop is deemed to be included in the quoted rate (ii) Spare part measured and paid seperatly in sch 'A' under relivent items. (iii) The cost of transportation to & from workshop is deemed to be included in the quoted rate. (iv) During the lowering of Pump and motor to the tube well any type happening case rate deemed to be included in the qouted rate. (v) The nature of defect accured same during the period of CA, there is no extra cost will be paid to the contractor.
Repair/Opening & overhauling of VT pump set by dismantling (in r/o ser item No 68) cleaning and servicing, replacement of minor parts required for proper functioning, painting the VT Motor body set with one coat of synthetic enamel paint after preparing the surfaces all as specified and directed by the Engr-in-charge. Note: (i) Major spare part measured and paid seperatly in sch 'A' under relivent items. (ii) The nature of defect accured same during the period of CA, there is no extra cost will be paid to the contractor.
Gun metal impeller as per existing size.
Neck Ring as per existing size.
Gland plate as per existing size.
Studs as per existing size.
Stainless steel line shaft 3 metre long as per existing size.
Top shaft 1.5 metre long as per existing size.
Guide spider 6" as per existing size.
Guide spider bush as per existing size.
Stainless steel sleeve as per existing size.
Shaft coupler as per existing size.
Stuffing box as per existing size.
Thrust bearing as per existing size.
Cast iron impeller housing as per existing size.
Disconnecting the electrical connection for taking out unserviceable dozing motor from any size from the dozing pump and other accessories carrying to workshop for repair, after repair dozing motor shifted to the existing location and re installation in orignal position including all electrical connection testing and commissioning complete all as specified and directed. Make- Sathya Sai Note: (i) The cost of transportation to and from workshop is deemed to be included in the quoted rate. (ii) The nature of defect accured same during the period of CA, there is no extra cost will be paind to the contractor.
M & L for removing the burnt winding wire of the dozing motor cleaning the slots for rewinding, and rewinding the motor with super enamelled copper winding wire superior quality as per exisitng gauge and size, varnishing, drying, replacement of bearings and assembling the motor of Cap up to 0. 5 HP complete all as specified and directed. Note: (i) The nature of defect accured same during the period of CA, there is no extra cost will be paind to the contractor.
M & L for disconnecting the dozing pump set and servicing, cleaning, checking and filling the gear oil as per existing make and model of dozing pump set are as under:- Note: (i) Replacement the defactive part will be measured and paid separatly (ii) The nature of defect accured same in defect liability period, there is no extra cost will be initiated. Make-Sathya Sai
PVC NRV set with glass ball for suction and delivery adopter
PVC adopter for suction and delivery without NRV
PVC Strainer washer type heavy duty or as per existing strainer for suction
Teflon gland square type
Chemical oil seal with cap
Dosing aginator gear box 25LPH
S.S agitating rod with fan, PP coating
Plunger assembly without PVC dosing head 25 LPH
Plunger assembly with PVC dosing head complete 25 LPH
Heavy duty PVC pipe for delivery & suction line
Rubber coupling bush as per existing size or make and model
Supply and fixing control panel for dosing Pump suitable for Model SSAPS/SDSPT/25 / or equivalent made of powder coated MS fabricated box cosisting of LED indicator, digital volt meter, Amps meter, single phase preventor, high voltage low voltage protection, plus buzzer will be on when single phase or high voltage /low voltage passing complete all as specified and directed.
Disconnecting the electrical connection for taking out unserviceable centrifugal motor of cap 7.5 HP to 20 HP from the foundation and other accessories carrying to workshop for repair, after repair centrifugal motor shifted to the existing pump house and re installation in orignal position including all electrical connection testing and commissioning complete all as specified and directed. Note: (i) The cost of transportation to and fro workshop is deemed to be included in the quoted rate. Spare part measured and paid under relivent items. (ii) The nature of defect accured same during the period CA, there is no extra cost will be paind to the contractor.
All as per ser item No 98 above here-in-before of capacity 0.5 HP
M & L for removing the burnt winding wire of the centrifugal motor, cleaning the slots and rewinding the motor with super enamelled copper winding wire superior quality as per exisitng gauge and size, varnishing, drying, replacement of bearings and assembling the motor of Cap 17.5 HP to 20 HP complete all as specified and directed. Note: (i) The nature of defect accured same in defect liability period, there is no extra cost will be initiated.
All as per Srl tiem No 100 but of capacity 10 HP complete.
All as per Srl tiem No 100 but of capacity 7. 5 HP complete.
All as per Srl tiem No 100 but of size 0. 5 HP
M & L disconnecting the centrifugal pump set, opening, servicing, cleaning and replacement the defective parts of centrifugal pumps Set at the various capacity of Pumps are as under complete all as specified and directed by Engineer-in-charge:- Note: (i) The nature of defect accured same in defect liability period, there is no extra cost will be initiated.
Replacement of impllers of cap 0.5 HP as per existing size.
Replacement of impllers of cap 7.5 HP as per existing size.
Replacement of impllers of cap 10 HP as per existing size.
Replacement of impllers of cap 17.5 HP to 20 HP as per existing size.
Replacement of gland bush of cap 0.5 HP including gland packing of existing size.
Replacement of gland bush of cap 7.5 HP including gland packing of existing size.
Replacement of gland bush of cap 10 HP including gland packing of existing size.
Replacement of gland bush of cap 17.5 HP to 20 HP including gland packing of existing size.
Replacement of ball bearing of cap 0.5 HP as per existing size.
Replacement of ball bearing of cap 7.5 HP as per existing size.
Replacement of ball bearing of cap 10 HP as per existing size.
Replacement of ball bearing of cap 17.5 HP to 20 HP as per existing size.
Replacement of center guide of cap 7.5 HP as per existing size .
Replacement of center guide of cap 10 HP as per existing size .
Replacement of center guide of cap 17.5 HP to 20 HP as per existing size .
Replacement of pump shaft of cap 7.5 HP to 10 HP as per existing size.
Replacement of pump shaft of cap 17.5 HP to 20 HP as per existing size.
Replacement of neck ring cap 7.5 HP to 10 HP any size .
Replacement of neck ring cap 17.5 HP to 20 HP any size .
Replacement of tyre coupling of cap 7.5 HP to 10 HP as per existing size.
Replacement of tyre coupling of cap 17.5 HP to 20 HP as per existing size.
All as per ser item No 126 above here-in-before but of cap 40HP with Relay range 36-60 Ampere TP Heavy duty complete.
All as per ser item No 126 above here-in-before but of cap 25HP with realy range 25- 40 Ampere TP Heavy duty complete.
All as per ser item No 126 above here-in-before but of cap 10-15HP with realy range 13- 21 Ampere TP Heavy duty complete.
All as per ser item No 126 above here-in-before but of cap 06 - 7.5 HP with realy range 9- 14 Ampere TP Heavy duty complete.
All as per ser item No 131 above here-in-before but of cap 0.5 HP to 7.5 H.P complete.
Disconnecting the electrical connection dismantling and removing existing automatic voltage stablizer for automatic operation oil cooled servo controlled type input voltage 300 – 440 V & out put voltage 415 V cap 100 KVA to 250 KVA opening, servicing, cleaning and refixing /re-installation the same. Note: Replacement repair of parts if any found damaged during repair shall be measured and paid for separately Note: (i) The nature of defect accured same in defect liability period, there is no extra cost will be initiated.
All as per ser item No 133 here-in-before but cap 50 KVA to 73 KVA
All as per ser item No 133 here-in-before but cap upto 45 KVA
Supply and fixing in replacement of dimmer coil with supper enameled copper wire including vamishing tapping and insulating material to get same cap 200-250 KVA. Note: (i) The nature of defect accured same in defect liability period, there is no extra cost will be initiated. connections all as specified and directed
All as per ser item No136 here-in-before but cap 100 KVA
All as per ser item No136 here-in-before but cap 50 KVA to 73 KVA
All as per ser item No 136 here-in-before but cap upto 45 KVA
Dismantling and Rewinding of dimmer coil with supper enameled copper winding wire including vamishing tapping and insulating material to get same cap 200 KVA. Note: (i) The nature of defect accured same in defect liability period, there is no extra cost will be initiated.
All as per ser item No140 here-in-before but cap 100 KVA
All as per ser item No140 here-in-before but cap 50 KVA to 73 KVA
All as per ser item No 140 here-in-before but cap upto 45 KVA
M&L dismantling of primary & secondary coils carefully taking out winding wire preparing for rewinding with super enameled copper winding wire of appropriates gauge with alled insulating material varnishing the winding with air drying insulating varnish, heat treatment of capacity 200 -250KVA etc complete. Note: (i) The nature of defect accured same during the period of CA, there is no extra cost will be paid to the contractor.
All as per ser item No144 here-in-before but cap 100 KVA
All as per ser item No144 here-in-before but cap 50 KVA to 73 KVA
All as per ser item No 144 here-in-before but cap upto 30-45 KVA
M&L for toping up of new transformer oil not less than 45 KV strength
Replacement of unserviceable printed circuit board (PCB) complete including taking down.
Replacement of dimmer brush with carbon brush including brush holder etc complete.
Replacement of analog Amp meter 0-200 Amps with CTS 96mm square as directed by Engr-in-charge.
Replacement of internal wiring with suitable size complete as directed by Engr-in-charge
Replacement of brass studs fixed for input & out put of stablizer with brass nuts for upto 100 to 200 KVA cap
All as per ser item No 154 here-in-beforebut cap 50 KVA to 73 KVA
All as per ser item No 154 here-in-before but cap 20 KVA to 45 KVA
Indicator lamp set (RYB) complete
S&F in replacement of On load Changeover including enclousere with advance neutral 415V, 250Amps, 4 pole including connecting incoming and outgoing connection and testing after making all connection as directed by Engr-in-Charge. Make : Havells / C&S / Standard / L&T.
All as per ser item No 160 here-in-before but 200 Amps 415 Volts complete. Make : Havells / C&S / Standard / L&T.
All as per ser item No 160 here-in-before but 160 Amps 415 Volts complete. Make : Havells / C&S / Standard / L&T.
All as per ser item No 160 here-in-before but 100-125 Amps 415 Volts complete. Make : Havells / C&S / Standard / L&T.
All as per ser item No 160 here-in-before but 63 Amps 415 Volts complete. Make : Havells / C&S / Standard / L&T.
Supply and fixing in replacement of PVC insulated and PVC sheathed flat submersible cable 6 sqmm 3 core with stranded copper conductor 1100 volts grade suitable for submersible motors and pumps and making electric connections all as specified and directed. Make Polycab/Finolex/Havell,s
All as per ser item No165 here-in-before but of size 10 sqmm 3 core
All as per ser item No 165 here-in-before but of size 16 sqmm 3 core
All as per ser item No 165 here-in-before but of size 25 sqmm 3 core
M&L in replacement of Sub main wiring with four single core stranded copper conductor unsheathed PVC insulated cable 1100V grade, 25 sq mm drawn through suitable size of non-metallic PVC rigid conduit with 16 sqmm copper conductor cable as earth conductor and conduit accessories fixed up in surface/ recessed as required, for three phase wiring including connecting motor stater to motor box complete all as specified and directed.
All as per item No 169 above here-in-before but of size 06 sq mm complete all as specified and directed.
All as per item No 169 above here-in-before but of size 04 sq mm complete all as specified and directed.
Supply and fix in replacement of MS tail piece of submersible pump of size 80 mm one side flange ended of existing size and one side of threaded end of existing size as directed by Engr-in-charge.
Supply and fix in replacement of MS tail piece of submersible pump of size 100 mm one side flange ended of existing size and one side of threaded end of existing size as directed by Engr-in-charge
Supply and fix in replacement of MS tail piece of submersible pump of size 150 mm one side flange ended of existing size and one side of threaded end of existing size as directed by Engr-in-charge
Supply and fix in replacement of MS tia rod ( U Clamp ) for holding of submersible pump set of size 25 x 6 mm both welded bolt of existing size as directed by Engr-in-charge
M & L in replacement of contactor 3 pole with coil voltage 220 volt type MNX 70 Rating complete as directed by Engr-in-charge
M & L in replacement of contactor 3 pole with coil voltage 220 volt type MNX 110 Rating complete as directed by Engr-in-charge
M & L in replacement of single phase preventor 440 volt complete as directed by Engr-in-charge
Taking down the starter panel & disconnecting the electrical connection from the main panel for repair and replacement of panel wiring, CT's, Connector, Lugs/thimble etc and reconnection at the same position testing commissioning complete all as specified and directed by Engineer-in-charge.
M&L for earthing with GI earth plate electrode 60×60cm ×6mm thick burried directly in ground (Earth pit not less than 2.25 mtr deep below normal ground level ) with top edge of earth plate not less than 1.5 metres below normal ground level, connected to GI earth strip 25x4.mm dia connected to earth plate electrode by means of bolts, nuts, check nuts and washers, earth wire protected with and including 40 mm bore medium grade ISI marked GI pipe not less than 7.5 meters long all as shown in electrical plate no 3 of MES schedule part-1,with and including PCC 1:3:6 type C1 pit with cover of RCC 1:2:4 type B1,reinforced with welded steel wire fabric not less than 4 kg per sqm with handle and angle iron frame, watering arrangment with 20 mm bore GI medium grade pipe ISI marked, GI funnel with GI wiremesh, filling with mixture of common salt and charcoal, necessary excavation, refilling, removing away soil and earth work in any type of soil, including test point, testing and commissioning complete.
Material and labaur Galvanised Iron strip 25X4 mm l etc. complete all as specified and directed by Engineer-in-Charge.
Material and labaur Galvanised Iron strip 32X6 mm l etc. complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of 150mm bore non rerurn (NRV) sluice valve of CI body, both ends flanged duly drilled, ISI marked with IS-14846-2000, PN-1.6 having Stainless Steel spindle and check nut including operating wheel cap, fixing with new nuts, bolts, washers and rubber insertion/ packing steel plate as required complete all as specified and directed.
All as per item No 183 above here-in-before of size 100 mm bore
All as per item No 183 above here-in-before of size 80mm bore
S&F in replacement of 80 mm bore sluice valve of CI body, both ends flanged duly drilled, ISI marked with IS-14846-2000, PN-1.6 having Stainless Steel spindle and check nut including operating wheel cap, fixing with new nuts, bolts, washers and rubber insertion/ packing complete all as directed for the following sizes :-
All as per item No 186 above of size 100 mm bore
All as per item No 186 above of size 150mm bore
Supply & fixing in replacement of MCCB 4 Pole, 200 to 250 Amps, 415 volt, 36 KA, 50 Hz adjustable type with thermal and magnetic release complete all as specified and directed. Make-Havells/ABB/L&T/Legrand/C&S.
Supply & fixing in replacement of MCCB, 4P, 160 Amps, 36 KA wih adjustable thermal and magnetic setting complete all as specified and directed Make -Legrand /ABB/L&T /Havells/C&S.
Supply & fixing in replacement of MCCB, TP, 100-125 Amps, 25 KA wih adjustable thermal and magnetic setting complete all as specified and directed Make -Legrand /ABB/L&T /Havells/C&S.
Supply & fixing in replacement of MCCB, TP, 63 Amps, 25 KA wih adjustable thermal and magnetic setting complete all as specified and directed Make -Legrand /ABB/L&T /Havells/C&S.
Repair & Maintenace of Grass/bush cutting machine and servicing including replacement of unserviceable parts and other accessories carrying to workshop for repair, after repair shifted to the water supply installation incl wire connection testing and commissioning complete all as specified and directed. Note: (i) The cost of transportation to and from workshop is deemed to be included in the quoted rate. Spare part measured and paid under relivent items. (ii) The nature of defect accured same during the period of CA, there is no extra cost will be paid to the contractor.
Disconnecting the electrical connection from the panel and lifting out unserviceable Centrifugal pump and Motor's of capacity 75 HP to 100 HP from the foundation including suction and delivery pipe and other accessories shifting to MES store from BSF Faloda tube well to GE Satwari complete all as specified and directed. Note: The cost of transportation from BSF Faloda to GE Satwari and T&P required for taking up C/F pump & motor from borewell is deemed to be included in the quoted rate.
Supply and fix in replacement of following spare part of Decrine dosing pump of make : Declibac
(a) Rotor assembly with bearings brachets & tollerence rings
(b) Coil 250V 50 HZ
(c) Single head feed rate control with shaft
(d) Pump head (Ferrule 1/4" & Duckbill included)
(e) Roller assembly
(f) Pump tube
(g) Injection check valve
(h) Weighted suction line stainer
(i) 3/8" white suction/discharge tubing
(j) Check valve duckbill
(k) Connecting nut 3/8" with adapter
(l) Connecting nut 3/8"
(m) Ferrule 1/4"
(n) Injection valve up to 7 Kg pressure for dosing pump
(o) Foot valve for dosing unit
(p) 25mm bore ball valve
(q) PVC diaphram for dosing pump
(r) PVC head for dosing pump
(s) 'O' ring for PVC head for dosing pump
M/S GULATI ENGINEERING WORKS
M/S S K Electricals Regd
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .