Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.8 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹10.9 L+₹1.6 L (17.2%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 |
| Sl No | Description | Qty | Unit | jain associates L2 | M/S INDIA ENTERPRISES L1 |
|---|---|---|---|---|---|
| 1.00 | Taking down submain wiring any size and any type complete all as specified and directed. | 750 | RM | 10 ₹7,500 | 5 ₹3,750 Lowest |
| 2.00 | Taking out MCB DBs of any size or any capacity and any type complete all as specified and directed. | 54 | Each | 30 ₹1,620 Lowest | 30 ₹1,620 Lowest |
| 3.00 | S&F Sheet metal enclosure MCB distribution board including 200 Amps bus-bar Triple pole and neutral 415 V, 4 Ways, double door type complete all as specified and directed. | 12 | Each | 2,500 ₹30,000 Lowest | 3,335 ₹40,020 |
| 4.00 | S&F Sheet metal enclosure MCB distribution board including 200 Amps bus-bar single pole and neutral 240V, 4 Ways, double door type complete all as specified and directed. | 12 | Each | 1,500 ₹18,000 | 1,220 ₹14,640 Lowest |
| 5.00 | S&F Sheet metal enclosure MCB distribution board including 200 Amps bus-bar single pole and neutral 240V, 8 Ways, double door type complete all as specified and directed. | 20 | Each | 2,200 ₹44,000 | 1,520 ₹30,400 Lowest |
| 6.00 | S&F Sheet metal enclosure MCB distribution board including 200 Amps bus-bar single pole and neutral 240V, 12 Ways, double door type, including taking down of existing sheet metal enclosure complete all as specified and directed. | 10 | Each | 4,500 ₹45,000 | 1,805 ₹18,050 Lowest |
| 7.00 | S & F in repair MCB SPN 40 to 63 Amps, 240 Volts, minimum 10 KA, "C" series rupturing capacity and to be housed in DBs catered here in before complete all as specified and directed | 42 | Each | 600 ₹25,200 Lowest | 1,020 ₹42,840 |
| 8.00 | S & F in repair MCB SP 5 to 32 Amps, 240 Volts, minimum 10 KA, "C" series rupturing capacity and to be housed in DBs catered here in before complete all as specified and directed | 100 | Each | 130 ₹13,000 Lowest | 170 ₹17,000 |
| 9.00 | S & F in repair MCB TPN 40 to 100 Amps, 240 Volts, minimum 10 KA, "C" series rupturing capacity and to be housed in DBs catered here in before complete all as specified and directed | 12 | Each | 1,500 ₹18,000 Lowest | 1,910 ₹22,920 |
| 10.00 | Supply and fix in repair sheet metal enclosure earth plug socket for SP 20 amps, with single pole MCB 240 volts complete all as specified and directed. | 20 | Each | 350 ₹7,000 Lowest | 1,190 ₹23,800 |
Tender Value
₹9.5 L
EMD Value
₹19,000
Closing Date
23 Jun 2025, 6:00 pmClosed
AGE (I) Naya Raipur
AGE(I) Naya Raipur, Military Engineer Services, C/O HQ COSA, Near International Cricket Stadium, Atal Nagar, Raipur(CG)-492101
As per BOQ
2025_MES_708041_1
8400/415/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE (I) Naya Raipur
As per NIT
7 documents required · 7 mandatory
₹500
AGE (I) Naya Raipur
₹19,000
29 Aug 2025
20 May 2025
25 Jun 2025
20 May 2025
23 Jun 2025
3 Jun 2025
Amount
Taking down submain wiring any size and any type complete all as specified and directed.
Taking out MCB DBs of any size or any capacity and any type complete all as specified and directed.
S&F Sheet metal enclosure MCB distribution board including 200 Amps bus-bar Triple pole and neutral 415 V, 4 Ways, double door type complete all as specified and directed.
S&F Sheet metal enclosure MCB distribution board including 200 Amps bus-bar single pole and neutral 240V, 4 Ways, double door type complete all as specified and directed.
S&F Sheet metal enclosure MCB distribution board including 200 Amps bus-bar single pole and neutral 240V, 8 Ways, double door type complete all as specified and directed.
S&F Sheet metal enclosure MCB distribution board including 200 Amps bus-bar single pole and neutral 240V, 12 Ways, double door type, including taking down of existing sheet metal enclosure complete all as specified and directed.
S & F in repair MCB SPN 40 to 63 Amps, 240 Volts, minimum 10 KA, "C" series rupturing capacity and to be housed in DBs catered here in before complete all as specified and directed
S & F in repair MCB SP 5 to 32 Amps, 240 Volts, minimum 10 KA, "C" series rupturing capacity and to be housed in DBs catered here in before complete all as specified and directed
S & F in repair MCB TPN 40 to 100 Amps, 240 Volts, minimum 10 KA, "C" series rupturing capacity and to be housed in DBs catered here in before complete all as specified and directed
Supply and fix in repair sheet metal enclosure earth plug socket for SP 20 amps, with single pole MCB 240 volts complete all as specified and directed.
S & F in repair PVC insulated unsheathed twin core multistrand aluminum cable of size 10 sqmm complete all as specified and directed.
S & F in repair PVC insulated unsheathed multistranded single core copper conductor of size 1.5 sqmm complete all as specified and directed.
S & F in repair PVC insulated unsheathed multistranded single core copper conductor of size 2.5 sqmm complete all as specified and directed.
S & F in repair PVC insulated unsheathed multistranded single core copper conductor of size 4.0 sqmm complete all as specified and directed.
S & F in repair PVC insulated unsheathed multistranded single core copper conductor of size 6.0 sqmm complete all as specified and directed.
M&L for submain wiring comprising single core, 2 Runs of 6 sqmm nominal cross sectional area multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including appropriate dia PVC conduits and conduit fittings complete including S&F 1 X 6 sqmm nominal cross sectional area multimultistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified and directed. Notes:- Two wires of 6 sqmm and one earth wire of 6 sqmm & PVC conduit shall be measured as one unit.
All as per item No 16 above but with 2 x 4 sqmm and 1x 4 sqmm as earth wire.
All as per item No 16 above but with 2 x 2.5 sqmm and 1x 2.5 sqmm as earth wire.
M&L for Rewinding of ceiling fans 1200mm sweep including opening of fan, Removing the burnt copper winding of ceiling fan after testing and cutting the rotor coil complete and making clean the rotor & the stator and rewinding with and including super enamelled copper wire of approved quality of existing gauge, over-hauling, lubricating with fresh grease including assembling with replacement of unserviceable parts (to be measured & paid seperately) and testing for satisfatory operation complete all as specified and directed.
Supply only condenser 2.5 MFD of approved make for ceiling fans complete all as specified and directed
Supply only condenser 3.5/4 MFD of approved make for exhaust fans complete all as specified and directed
Supply only GI pipe light grade with all fitting and fixed complete for ceiling fan as down rod .75 cm long of 15 mm bore complete all as specified and directed.
M&L in replacement for clamps and back plates fabricated from steel section conforming to Gde Fe 410-0 or Fe 310-0 includingnuts, bolts, washers, drilling holes for bolts in any shape or size for fixing ceiling fan complete weighing not more than 2Kg complete all as specified and directed.
S&F in replacement of PVC flexible 3 core 1.5 sqmm cable hrfr with copper con-ductor of size 16/0.20 mm from ceiling rose to fan including connection complete all as specified and directed.
M & L for Inspection and maintenance of water heater (Geyser) of capacity, 25 ltrs to 50 litres including performing the following task at different locations of COSA Mil Stn. (a) Removing the heather plate assembly and descaling the heating element/pipe either by use of acid or equa cleaner to make it functional complete (b) Checking and setting of thermostat between 70 to 80 degree Celsius (c) Check working of NRV stop cock, pressure release valve and servicing carefully to make it functional (d) Repairing of earthing connection, power switch, socket connection replacement of indicator lamp to make it functional (e) Examine water leakage and rectifying as required and replacement of rubber washer gasket etc to make it functional (f) Inspect over flow vent pipe, safety valve and remove blockage if required to make it functional complete all as specified and directed.
S & F in repairs of heating element of rating 2 KW to geyser 25 to 50 litres capacity, any type, make complete all as specified and as directed.
All as per item No 37 here in above but 1.5 KW capacity
S & F in repairs of Thermostate for geyser of capacity 25 to 50 litres any type, make complete all as specified and as directed.
S & F in repairs inner copper tank made out of cold rolled pure electrode type copper sheet double lapped welded internally and hydraulically tested for geyser 25 litres capacity complete all as specified and as directed
M & L for Earthing complete with galvanised steel earth plate electrode of size 60cm X 60cm X 6mm buried directly in ground (earth pit not less than 2.25 metres deep below the normal ground level) with top edge of the plate not less than 1.5m below normal GL connected to GI earth wire 4 mm dia by means of GI bolts, nuts, check nuts and washers and earth strip protected by 25 mm dia GI pipe medium grade and connected to main distribution board/earthing test point all as shown on electrical plate No.3 of SSR Part I and all as specified including testing on completion.Notes: The unit rate shall also include for excavation, earth work in hard/dense soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix, type B1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh, protection pipe for earth lead upto 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II and also refer Plate No-03. Earth strip and protection pipe beyond 7.5m shall be measured and paid separately. Note :- Earthing will be redone if desied erath result not found during testing of the same at site.
S & F in repairs air termination rod single pointed aluminium,12 mm dia and 300 mm long complete all as specified and directed.
S & F in repairs aluminium strip 25 X 3.15 mm with PVC saddle and PVC gutties for keeping the gap with roof and wall complete all as specified and directed.
S & F in repairs test point terminal block made out of gun metal or phosphours bronze of size 75 x 75 x 25 mm drilled and screwed including 3 Nos. 8mm dia and 25mm long head screw complete all as specified and directed.
S & F in repairs GI strip 32 X 6 mm burried in ground complete all as specified and directed.
Supply only ISI marked insulation tape of size 1.70 cm x 6.5M x 0.125mm. Make Steelgrip/Anchor
S & F in repairs rigid non-metallic PVC conduit 20mm dia exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed.
All as per item No 47 above but 25mm dia
S & F in repairs of PVC casing capping 15mm dia alognwith all screws and fixing on wall complete all as specified and directed by Engr-in-Charge
S & F in repairs of PVC casing capping 20mm dia alognwith all screws and fixing on wall complete all as specified and directed by Engr-in-Charge
S & F in repairs of PVC casing capping 25mm dia alognwith all screws and fixing on wall complete all as specified and directed by Engr-in-Charge
S & F in repairs of wood wool pads of best quality as approved with and including wire mesh jalli for desert cooler of any size make and capacity complete all as specified and as directed
M & L for repairs to Desert cooler body with required switches, copper wire, jali and plug top complete with all accessories all as specified and directed by Engr-in-charge.
S & F in repairs of PVC pipe of superior quality 15 mm dia suitable for desert cooler complete all as specified and as directed
M & L for Comprehensive maintenance of desert cooler of any type and any make, fixed at different location a in HQ COSA military station including taking down, cleaning all dirt, dust, oiling of motor and pump, checking of parts, including replacement of nuts bolt, screw etc and preparation of the desert cooler body and tank by scrubbing the old paint and spray painting with two coats of synthetic enamel paint complete all as specified and as directed. Note : Supply and replacement of unsv parts shall be measured and paid separately.
S & F in repairs fan motor for desert cooler complete with blade, locknut, with all accessories 220/250 Volt complete all as specified and as directed.
S & F in repairs of desert cooler pump motor 230/250 Volt, submersible type suitable for 4000 CFM capacity of desert cooler (Head shall not be less than 2 mtr) complete with mounting accessories complete all as specified and as directed.
Supply and fixing ceiling fans complete with blades, down rods, and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed..
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 200mm complete all as specified and as directed..
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm complete all as specified and as directed..
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, 2 Nos connection pipe etc complete all as specified and as directed.
Note : For item No 57 to 61 :- The UNSV items to be deposit to MES store yard for further BER action.
Total contract sum shall be calculated after deduction of schedule of credit amount of Rs. 48,575.00
jain associates (BID ID -3317297)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .