| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.1 LAccepted-AOC NO 12 5TH B CROSS SHARADAMBA NAGAR M E S ROAD BANGALORE 560013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹10.0 L+₹1.7 L (19.9%)Rejected-Finance | L2 | Rejected-Finance Rejected Quoted rates are higher than L1 |
Tender Value
₹12 L
EMD Value
₹24,000
Closing Date
30 Nov 2020, 6:00 pmClosed
Garrison Engineer M AF Jalahalli
Garrison Engineer (M) (AF) Jalahalli Bangalore 560013
8528E8REPAIRS AND MAINT OF INTERNAL DISTRIBUTION SYSTEM LIGHTNENING CONDUCTORS AND EARTHING INFRASTRUTURE IN TECH AND DOMOSTIC AREA UNDER AGE E M WEST OF GE M AF JALAHALLI BANGALORE
2020_MES_391858_1
8528E8
Open Tender
Electrical and Maintenance Works
Item Rate
303 days
JALAHALLI
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Garrison Engineer M AF Jalahalli
₹24,000
5 Mar 2021
2 Nov 2020
2 Dec 2020
2 Nov 2020
30 Nov 2020
17 Nov 2020
3 Nov 2020 - 11 Nov 2020
Amount
Earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of plate not less than 1.5 m below ground level connected to and including galvanised earth strip of size 25x4 mm (up or 7.5 mtr length) and GI pipe 40 mm light grade for protection of GI earth strip by means of bolts, nuts, checknuts and washers made out of galvanised iron and connected to earth test point as shown in electrical plate No. 3 of SSR Part-1-2009 and as specified or indicated and testing on completion including excavation and earth work any in type of strata available at site, PCC (1:3:6) type C-1 for earth chamber, precast RCC slab 50mm thick in cement concrete (1:2:4) type B-1 reinforced with welded steel wire fabric (xpm) weight not less the (4kg/sqm) funnel with GI watering pipe of 20mm bore medium grade, wire nuts and lugs including taking down old u/s one complete all as specified and as directed.
Supply and fixing in replacement of galvanised iron strip of size 32x6mm burried in ground or fixed on wall with suitable epoxy base insulator on wall/floors and connected to test point including bending, jointing at test points with 2 Nos GI nuts, bolts, with lead washers, jointing strips at all joints complete all as specified and as directed.
Supply and fixing in replacement of aluminium strip 25x3mm fixed with epoxy based insulator for down conductor air terminal network including drilling two Nos holes at each joint, one set of lead washers between strips, two sets GI nut and bolt, gutties, screws etc. complete all as specified and as directed.
Supply and fixing in replacement earth continiuty conductor or main earthing lead fixed on wall on batten or recess or chases or buired in ground or drawn in conduit / pipe or fixed to pole or any other indicated suituation for loop earthing etc, as required for copper strip 32 mm x 6 mm with proper saddles/spacer, screw etc., complete all as specified and as directed. Note : All joints of copper shall be of brazing only
Supply and fixing in replacement Earth continiuty conductor or main earthing lead fixed on wall on batten or recess or chases or buired in ground or drawn in conduit / pipe or fixed to pole or any other indicated suituation for loop earthing etc, as required for galvanised iron wire 4 mm dia with proper saddles / spacer, screw etc, alll as specified and directed. Note : All joints of copper shall be of brazing only
Taking down and refixing of existing aluminium strip 25x3 mm by brazing at each joints between strip including saddle/insulator/PCC block where required complete all as specified and as directed.
Taking down and refixing of existing GI strip 32 X 6 mm brazing at each joints between strip including saddle/insulator/PCC block where required complete all as specified and as directed.
Taking down and refixing of existing copper strip 32 X 6 mm brazing at each joints between strip including saddle/insulator/PCC block where required complete all as specified and as directed.
Taking down and refixing of existing GI wire 4 mm dia laid in ground or wall with epoxy base insulator including welding the joints and connecting to test point complete all as specified and as directed.
Supply and fixing in repair test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and as directed.
Supply and fixing in replacement of air termination single pointed aluminium rod of 12mm dia 300 mm long fixed to strip/pipe including drilling holes, nuts, bolts washers for resting/ supporting of air terminals etc. complete all as specified and as directed.
Supply and fixing in replacement of air termination single pointed copper rod of 12mm dia 300 mm long fixed to copper strip including drilling holes, nuts, bolts washers for resting/ supporting of air terminals etc. complete all as specified and as directed.
Refixing of air termiantion single pointed Aluminium rod 12mm dia 300mm complete all as specified and as directed.
Refixing of air termiantion single pointed copper rod 12mm dia 300mm complete all as specified and as directed.
Repairing and maintenance of old existing earth pit by taking out carefully earth plate, watering pipe, earth lead protection pipe and re-buried the same after removing sludge from the plate & pipes including re-connection/brazing the plate and strip, whichever is required at site (Earth pit not less than 2.25 mtr deep below normal ground level ) with top edge of earth plate not less than 1.5 metres below normal ground level,complete all as specified and directed including PCC 1:3:6 type C1 pit with cover of RCC 1:2:4 type B1,reinforced with welded steel wire fabric not less than 4 kg per sqmtrwith handle andangle iron frame,watering arrangment with 20 mm bore GI medium grade pipe ISI marked, GI funnel with GI mesh,filling with mixture of commen salt and charcoal,necessary excavation, refilling, removing away soil and earth work in any type of soil including test point, testing and commissioning complete all as specifed and as directed. Note : GI Funnel, brazing, mixture of salt/char coal/MGSO4 shall be measured and paid separately under releavant items.
Supply and fixing in replacement GI funnels for earthing complete all as specified and as directed.
Supply only of common salt commercial all as directed complete all as specified and as directed.
Supply only of charcoal dust complete all as specified and as directed.
Supply & Fixing in replacement PCC block of size 150 x 150 x 150mm in PCC (1:3:6) type C-1 with 20mm graded aggregate for fixing of roof conductor/air termination rod/GI strip etc. complete all as specified and as directed.
Supply only of back filling compound
Supply only magnesium sulphate (MGSO4)
Material and labour for Brazing of copper/Aluminium/GI strip for continuity complete all as specified and as directed.
Material and labour for Testing of earth resistance of earth pit and writing of earth resistence value in existing board complete all as specified and as directed. Note:- (i) The contractor has to arrange his own testing kit of suitable range for checking of earth resistence.
Material and labour for Earthing complete with copper earth plate electrode of size 600 x 600 x 3.15 mm thick burried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of plate not less than 1.5 m below ground level connected to and including copper earth strip of size 20x3 mm (up or 7.5 mtr length) and GI pipe 40 mm light grade for protection of GI earth strip by means of bolts, nuts, checknuts and washers made out of galvanised iron and connected to earth test point as shown in electrical plate No.3 of SSR Part-1-2009 and as specified or indicated and testing on completion including excavation and earth work any in type of strata available at site, PCC (1:3:6) type C-1 for earth chamber, precast RCC slab 50mm thick in cement concrete (1:2:4) type B-1 reinforced with welded steel wire fabric (xpm) weight not less the (4kg/sqm) funnel with GI watering pipe of 20mm bore medium grade, wire nuts and lugs including taking down old u/s one complete all as specified and as directed.
Supply and fixing in replacement of 40 mm bore galvanised steel water tubing light grade with all fitting fixed to wall and ceiling or laid in floors complete all as specified and as directed.
Supply and fixing in replacement of 40 mm bore galvanised steel water tubing light grade with all fitting laid in trenches complete all as specified and as directed.
Supply and fixing in replacement of 25 mm bore galvanised steel water tubing medium grade with all fitting fixed to wall and ceiling or laid in floors complete all as specified and as directed.
Supply and fixing in replacement of 25 mm bore galvanised steel water tubing medium grade with all fitting laid in trenches complete all as specified and as directed.
Supply and fixing in replacement of 15 mm bore galvanised steel water tubing medium grade with all fitting fixed to wall and ceiling or laid in floors complete all as specified and as directed.
Supply and fixing in replacement of 15 mm bore galvanised steel water tubing medium grade with all fitting laid in trenches complete all as specified and as directed.
Supply and fixing in replacement Bib Tap of 20 mm dia standard of PTMT any colour high pressure screwed for iron pipe complete all as specified and as directed.
Supply and fixing in replacement Bib Tap of 15 mm dia standard of PTMT any colour high pressure screwed for iron pipe complete all as specified and as directed.
Material and labour for Cutting the existing GI pipe of any size for tapping or new connection with15 mm to 40 mm as per site requirement including required fitting complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying pipe line and getting out in soft/loose soil complete all as specified and as directed.
Returning filling in including spreading leveling watering and well ramming in layers not exc 25cm thick with dry type of soil complete all as specified and as directed.
Removing excavated surplus soil to a distanc3 not exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as specified and as directed.
Material and labour for earthing pit of size 0.45 x 0.45x 0.45 m and 150 mm thick by PCC 1:3:6 type C1 with 20 mm graded stone chamber with RCC 1:2:4 type B1 in cover slab complete all as specified and as directed.
Material and labour for earthing pit cover of size 0.45 x 0.45x .04 m with RCC 1:2:4 type B1 with 20 mm graded stone including required TMT steel reinforcement complete all as specified and as directed.
Supply and fixing of CI pit cover of suitable of suitable size for existing earthing pit complete all as specified and as directed.
Material and labour for fixing earth indicators made out of 3 mm thick MS sheet of size 200mm x 300mm duly fixed in MS angle iron 25mmx25mm of 450 mm long to be fixed to ground by means and including neceaary cement concrete and painting with two coats of synthetic enamel paint over a coat of red oxide primer complete, writing earth reading and connected palnt / panel etc, and excavation and earth work complete all as specified and as directed.
Material and labour for Aluminium strip 25X3.15 MM wth saddels and fixing screws etc, for roof conductors and down conductors above ground with require connected items complete all as specified and as directed.
Material and labour for Copper strip 20X3.15 MM wth saddels and fixing screws etc, for roof conductors and down conductors above ground with require connected items complete all as specified and as directed.
Material and labour for Copper strip 32X6MM buried in ground with require connected items complete all as specified and as directed.
Material & Labour for New Maintenance free Earthing with minimum Four Nos single earth rods each pit consisting of copper coated steel rod of size 17.2mm dia 3 mtrs long 250 Microns molecularly bonded, joined with connecting clamps filled with maintenance free earth enhancing compounds Curec+ 6 kgs & Curecon 10 kgs, compounds strictly be a Eco friendly and must comply to IEEE 80:2000 clause 14.5 (d), IEEE 80:2000 clause 14.5 (b) and this compound should be Electrically & Thermally conductive, must be tested for Long term in CPRI for at least 2 year to display its stability & compound must be ISO certified, interconnecting the pit with 25mm x 3mm copper strip with exothermic welding and connecting up to the ring to achieve the earth resistance value below 1 ohm connected with 25x3mm Copper strip duly fixed with spacer and saddles and all connected accessories including up to 7.5 mtrs copper strip up to equipment room and terminating the wire with 25mm x 6mm 300 mm long copper bus bar insert in the water proof suitable box fixed on wall with insulator support. NOTE: I. Soil Resistivity must be checked before designing the Quantity of earth pits, accordingly design should be submitted II. The ring main earth resistance shall be below 1 ohms. III. Rate deemed to be inclusive of one HDPE inspection pit of 308mm x 308mm x 214mm depth. IV. Earth pit is required to be identified by the specific marker, colour codes (a) Maint free ring earthing pits- Red colour and write proper earthing details all as directed by Engg-in-charge.
Material and labour for sub main wiring with two single core stranded copper conductor unsheathed PVC insulated cable 1100V grade, 4 sq mm drawn through and including suitable size of non-metallic PVC rigid conduit with 4sqmm copper conductor cable as earth conductor and conduit accessories fixed up in surface/ recessed as required, including connecting up complete all as specified and directed including taking down old U/S wiring. Note:-Two run of cable and one run of earth continuity copper conductor and non metalic PVC conduit shall be measured as one unit length.
Material and labour for sub main wiring with two single core stranded copper conductor unsheathed PVC insulated cable 1100V grade, 6 sq mm drawn through and including suitable size of non-metallic PVC rigid conduit with 6 sqmm copper conductor cable as earth conductor and conduit accessories fixed up in surface/ recessed as required, including connecting up complete all as specified and directed including taking down old U/S wiring. Note:-Two run of cable and one run of earth continuity copper conductor and non metalic PVC conduit shall be measured as one unit length.
Material and labour for sub main wiring with two single core stranded copper conductor unsheathed PVC insulated cable 1100V grade, 10 sq mm drawn through and including suitable size of non-metallic PVC rigid conduit with 10 sqmm copper conductor cable as earth conductor and conduit accessories fixed up in surface/ recessed as required, including connecting up complete all as specified and directed including taking down old U/S wiring. Note:-Two run of cable and one run of earth continuity copper conductor and non metalic PVC conduit shall be measured as one unit length.
Supply and fixing sheet metal enclosure consisting of metal clad socket 3 pole + Neutral + earth including one MCB TP 20Amps 10KA.including taking down old unserviceable plug socket and offering for credit complete all as specified and directed.
Cutting chassis in brick surfaces n. exc. 10cm girth for concealed conduit wiring and making good the surface to match the adjoining surfaces.
RAMESH BABU CO
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .