Director, CSIR - IGIB
CSIR - IGIB, Mall Road, Near Jubilee Hall Hostel
Repair of Connecting Corridor at DG-1 Building CSIR-IGIB, South Campus Sukhdev Vihar, Mathura Road, New Delhi- 110025
2024_CSIR_212170_1
IGIB/ W S/ Repair of Connecting Corridor/ DG-1/2024-2025
Open Tender
Civil Works
Item Rate
60 days
CSIR - IGIB, Mathura Road, New Delhi
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
Director, CSIR -IGIB
₹10,290
11 Nov 2024
22 Oct 2024
30 Oct 2024
22 Oct 2024
29 Oct 2024
22 Oct 2024
Amount
Grading roof for water proofing treatment with : Cement mortar 1:3 (1 cement : 3 coarse sand)
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase
Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding
Providing and fixing 100 mm diameter and 60 cm long rain water spout in cement mortar 1:4 (1 cement : 4 fine sand) : Stone ware spout
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes : 110 mm diameter
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3 mm thick
Finishing walls with textured exterior paint of required shade : Old work (One or more coats) applied @ 1.82 ltr/10 sqm.
12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand)
Providing and applying plaster of paris putty of 8 mm thickness (average 6 to 10 mm) over plastered surface to prepare the surface even and smooth complete
Providing and fixing Anti Skid Floorig tape of width MMcluding all labour, material, taxes as per the Direction of Engineer-in-Charge.
Hashim Hussain And Sons (BID ID -761463)
B S ELECTRICALS (BID ID -761728)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .