Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹77.0 LAccepted-AOC NOT FOUND | L1 | Accepted-AOC AWARDED BY L1 BIDDER M/S SHIV SHANKAR ENTERPRISES | |
| 2 | L2₹80.4 L+₹3.3 L (4.34%)Rejected-Finance | L2 | Rejected-Finance L2 FOR REJECTED | |
| 3 | L3₹80.7 L+₹3.7 L (4.79%)Rejected-Finance | L3 | Rejected-Finance L3 FOR REJECTED | |
| 4 | L4₹84.4 L+₹7.3 L (9.54%)Rejected-Finance | L4 | Rejected-Finance L4 FOR REJECTED | |
| 5 | L5₹84.8 L+₹7.8 L (10.1%)Rejected-Finance 31 TILAK NAGAR SRI GANGANAGAR 335001 RAJ | GANGANAGAR | RAJASTHAN | 335001 | L5 | Rejected-Finance L5 FOR REJECTED |
Tender Value
Refer Docs
EMD Value
₹1.7 L
Closing Date
17 Apr 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ COMMANDER WORKS ENGINEER SRI GANGANAGAR
HQ CWE POST BOX 48 SRI GANGANAGAR-335001 (Rajasthan)
CA NO CWE SGNR 116 of 2020 21 PROVN OF RING MAIN NETWORK FOR UNITERRUPTED POWER SUPPLY FOR SRIGANGANAGAR MIL STATION
2021_MES_428863_1
CA NO. CWE SGNR - 116 OF 2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
SRI GANGANAGAR
CLASS-C
CATEGORY-B(ii)
9 documents required · 9 mandatory
₹1,000
Yes
₹1.7 L
Yes
27 Apr 2021
20 Mar 2021
20 Apr 2021
20 Mar 2021
17 Apr 2021
3 Apr 2021
60 days
Amount
M&L for switch of Air break gang operated triple pole mechanically operated vertical type 12 insulators and with galvanised frame, operated from ground level including operating rod, handle locking mechanism, current carrying capacity 400Amps 11000 volts, drop out fuse including nuts bolts and washers required to fix and testing on complete all as specified and as directed by Engr-in-Charge.
M&L for cross arms bracing, stiffeners supports, D-clamps and back plates fabiricated from structural steel section grade of Fe-290 (Grade E-165) such as channel angle iron, flat iron, eye hook, pole clamps etc including nuts bolts washers welding, bending cold or hot drilling holes for bolts if any clamp or size including two coat of primer (red oxide) after preparation of steel surfaces complete all as specified and as directed by Engr-in-Charge. NOte: Unexposed surface shall be given in one coat of primer only.
Supply and fix lighting arrester expulsion type complete with all fitting type transmission class discharge capacity 65 Kilo amp 11 KV HT pressure complete all as specified and directed by Engineer-in-charge.
Supply, laying, jointing testing and commissioning in replacement of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 11 KV grade of cross-sectional area 120 Sqmm, 3 core, IS 7098 marked, suitable for HT 11 KV(UE) system , laid in trenches / ducts / encased in GI pipe / fixed to pole complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches not exc 1.5 m wide and n. exc 1.5 m depth or n. exc 10 Sqm on plan and n exc 1.5 m in depth for foundations of poles, struts, stays etc or laying underground cable etc. in soft/loose soil, & getting out, complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in soft/loose soil complete all as specified and directed by Engineer-in-charge.
Removal of surplus soil to a distance n.exc 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by Engineer-in-charge .
M & L for dry sand cushioning to UG cable with a layer of sand 8 cm thick before laying of cable and 15cm thick after laying of cable to the full width of trench and punning down to 18 cm thick including well ramming and watering complete all as specified and directed by Engineer - in - Charge.
Supply and laying unreinforced precast cable cover HV class type 1 flate size 300 mm x180mmx 40mm complete all as specified and directed by Engr-in-Charge.
Boring of holes under road/pavement/hard standing or any other situation by manual mean and including passing GI pipe 80mm bore and making good both the ends complete all as specified and directed by Engineer-in-Charge. Note : Pipe and cable will be measured and paid separately
Supply and laying of GI pipe light grade 80mm dia for cable crossing in floors etc complete all as specified and directed by the Engineer in charge.
S&F Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm all as specified and directed by Engr-in-Charge.
S&F Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm all as specified and directed by Engr-in-Charge.
Material and labour for earthing complete with galvanised earth plate electrode 600x600x6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr deep below normal ground level connected to and including GI strip 32 x 6mm (upto the body of equipment) by means of GI bolts/nuts/washers, protected by 40 mm bore GI light grade pipe for watering and including funnel, wire mesh, RCC cover and frame, PCC (1:3:6) type c2 (using 20mm graded crushed stone aggregate) as in earthing pit including necessary excavation and earth work, all as specified & shown in electrical plate no 3 of MES schedule Part-I. Note. The unit rate includes lead & protection pipe upto 7.5 mtr from topt of eart plate.
Supply and errecting Prestressed cement concrete pole, 11.0 metres long of cross section (152mm x 152mm) at top and (52mm x 260mm) at bottom, class 9 complying with requirement of IS-1678 1978 including painting of poles with two coats of synthetic enamel paint over as coat of primer black and strips 30 cm wide each (05 Nos) upto 1.5 mtr height from coping and numbering of poles complete all as specified and directed by Engineer-in-charge.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to galvanised iron of 4 sqmm SWG earht wire fixed by means of bolts, nuts and washers of the earth wire galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 40mm dia upto 3m height above ground level and water pipe 20mm dia GI medium grade with socket and plug 30 cm above ground level including earthwork, PCC chamber in PCC (1:3:6) type C-2 using 40mm stone aggregate, cast iron cover, wire meah etc all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 complete and all as specified and direcrted by Engr-in-charge Notes :- (i) 20 mm dia GI pipe for watering to be provided with a socket and plug and should be 30 cms above ground level. (ii) GI strip upto DBs earth connection is included in this item. (iii) GI pipe 40 mm dia protection pipe shall be provided upto Ground level complete all as specified and directed by Engineer-in-Charge.
Earth continuity conductor or main earthing lead of size 4mm dia galvanised iron or steel wire complete all as specified & directed by Engineer-in-charge.
Earth continuity conductor or main earthing strip of size 32x6mm dia galvanised iron strip complete all as specified and directed by Engineer-in-charge.
M&L for Anti climbing devices; comprising 2.24mm dia galvanised steel 2-strand barbed wire with 2.00mm dia barbs wrapped spirally round poles, to a length of 0.5 to 1.0 metre clamped and properly secured or as ordered (clamps measured separately) complete all as specified and directed by Engineer-in-charge.
M&L for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified and directed by Engineer-in-charge.
Cable route path indicators made out of 40 x40 x 4 mm angle iron 1 Mtr long and plate 100 x 150 x 6 mm welded only on one end and embossed as cable HT / LT including pCC works for embededing complete all as specified and directed by Engr-in-Charge.
Supply , installing, testing and commissioning of 11 KV Ring main unit outdoor type (SABRE Range) stainless steel enclosure, IP-64 degree protection, tested as per IEC-6222271-200, fabricated by automatic robotic welding VRE (Vacuum Ring main unit-Extensible) variation, isolated in clean SF6 gas for Ring Switch (02 Nos for incoming) and vacuum for CB (01 No for outgoing), rated voltage 12/15.5 KV, 630 Amps rated current, symmetrical breaking capacity-21 KA/3 sec, making current 52.5 kAp, impulse withstand -75/110 kVp, having miniumum gas pressure at 0 bar and filling gas pressure at 4 bar, incoming cable termination at side bottom, tee off at rear bottom, bottom cable tests, common switching chamber with vacuum tee off circuit breaker, all switch positions have pad locking & castell interlocking facilities, internal ac protection including cable boxes, extensible from both sides, fully SCADA compatible unit with remote switching, earth fault indicators, meetering module, motorised kit for automation complete all as specified and directed by Engineer-in-charge. Note : (a) Drawing for CSS shall be approved by accepting officer before placement of order (b) PCC foundation for mounting of CSS as per design of manufacturer shall be included in overall cost quoted. c) CSS shall be suitable for operation between Minus 10 Degree Centigrate. Nothing extra shall be payble on this account. (d) Suitable Platform as per OEM instructions for installation of RMU will be include in the quoted rates
Excavation in trenches/post holes in soft/loose soil exceeding 1.5 mtr wide and not exceeding 3.00 meter in depth for laying of cable and for poles/stay and struts not exceeding 10 Sqm on plan and getting out, excavated earth, forming bottom surfaces to required level complete all as specified and directed by Engineer-in-charge.
Material and labour for Plain cement concrete 1 :3 :6 type C1 using 20 mm graded stone aggregate as platform mass concrete , coping to pole for embedding stay rods all as specified, including necessary form work and applying two coats of cement based paint on coping , platform , etc, where ever required complete all as specified and directed by Engineer-in-charge.
Material and labour for Plain cement concrete 1:4:8 type D2 suing 40 mm graded stone aggregate for pole foundation, filling and mass complete all as specified and directed by Engineer-in-charge. ---------------------------------------------------------------------------------------------------
Shree Balaji Construction
Rajindera Enterprises
m/s G.S. Enterprises
Singla Electricals
BHARAT NIRMAN INFRASTRUCTURE COMPANY
Raman Electric Trading Co
UNITED SAINI BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .