Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹42.6 LAccepted-AOC H NO 39 3 CHANNI HIMMAT JAMMU 180015 J K | JAMMU | JAMMU AND KASHMIR | 180015 | 1 | Accepted-AOC L1 BIDDER | |
| 2 | 2₹44.6 L+₹1.0 L (2.33%)Rejected-AOC DHAMDHA ROAD DURG CHHATTISGARH 491001 | DURG | CHHATTISGARH | 491001 | 2 | Rejected-AOC OTHER THAN L1 BIDDER | |
| 3 | 3₹44.9 L+₹1.3 L (3.07%)Rejected-AOC | 3 | Rejected-AOC OTHER THAN L1 BIDDER | |
| 4 | 4₹47.0 L+₹3.5 L (7.99%)Rejected-AOC | 4 | Rejected-AOC OTHER THAN L1 BIDDER | |
| 5 | 5₹48.0 L+₹4.5 L (10.3%)Rejected-AOC | 5 | Rejected-AOC OTHER THAN L1 BIDDER |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
9 Jun 2020, 6:00 pmClosed
GE SATWARI
GE SATWARI
Comprehensive maint / repair of Roof Treatment and allied works under AGE B/R I under GE Satwari
2020_MES_344130_1
GEJM-36/20-21
Open Tender
Civil Works
Item Rate
180 days
GE SATWARI
AS PER TENDER DOCUMENT
9 documents required · 9 mandatory
₹500
GE SATWARI
₹94,000
Yes
19 Jun 2020
12 May 2020
11 Jun 2020
12 May 2020
9 Jun 2020
26 May 2020
Amount
Demolition of cement concrete(reinforced) of any description ,including unserviceable RCC tanks etc and in any position , (up to 4th storey) not otherwise specifically provided for complete,removed out of MOD land complete all as specified and as directed.
Dismantlling of brick tiles or terracing tiles (up to 4th storey) single layer on roof etc ,removed out of MOD land.
Dismantling Flat iron wind tie , any description , size and shape and removal from site complete all as directed.
Demolition of cement concrete (unreinforced) of any description (up to 4th storey) and in any position,removed out of MOD land all as directed .
Dismantling of plain or corrugated steel sheeting etc including ridge in roof covering complete and set a side all as directed.
Dismantling of asbestos cement (corrugated or semi-corrugated) sheet in roof covering all as specified.
Preparation surfaces of old concrete floor by picking, scrubbing down with steel brushes, sweeping clean and washing down with water to remove dust etc and PCC 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) with average thickness 50 mm laid in two layers of 25 mm thickness each with wire netting of 0.60 mm dia and size of mesh 12 mm x 12 mm laid between the two layers finished even and smoothes in roof padding ( upto 2nd storey building)all as specified and as directed Note:- The wire mesh shall be measured and paid separately under the respective item .
Preparation surfaces of old concrete floor by picking, scrubbing down with steel brushes, sweeping clean and washing down with water to remove dust etc and PCC 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) with average thickness 50 mm laid in two layers of 25 mm thickness each with wire netting of 0.60 mm dia and size of mesh 12 mm x 12 mm laid between the two layers finished even and smoothes in roof padding ( Only upon 4th storey building)all as specified and as directed Note:- The wire mesh shall be measured and paid separately under the respective item .
Preparation surfaces of old concrete floor by picking, scrubbing down with steel brushes, sweeping clean and washing down with water to remove dust etc and PCC 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) finished fair and even in roof padding ( upto 4th storey building)all as specified and as directed Note:- The wire mesh shall be measured and paid separately under the respective item .
Supply only 25 mm size, wire netting of galvanized iron chicken mesh, 0.60 mm dia complete all as specified and directed.
Providing cement concrete type B-1 1:2:4 (using 20 mm graded stone aggregate ) in Base of PVC tank upon roof ( upto 4th storey building) all as specified and direcred by Engr. In Charge
M&L for 40 mm thick bricks tiles laid on roof in 15mm thick CM 1:6 and joint grouted in cement mortar (1:3) mixed with 5% crude oil by weight of cement complete all as spd
M&L for 40 mm thick bricks tiles laid on roof in 15mm thick CM 1:6 and joint grouted in cement mortar (1:3) mixed with 5% crude oil by weight of cement except tiles complete all as spd
M&L for 15 mm thick plaster in cm 1:4 finished fair and even on RCC roof slab ( upto 4th storey building) incl mixing of integral water proofing compound : Note :- IWPC shall be measured and paid for separately)
M&L for 5 mm thick plaster in cm 1:4 finished fair and even on RCC roof slab ( upto 4th storey building) incl mixing of integral water proofing compound : Note :- IWPC shall be measured and paid for separately)
Complete removal of existing water proofing treatment of any description incl under layer, taking down of cement plaster / demolition of cement concrete any thickness and removal of debris off the premises including grubbing up of trees and preparation of concrete surfaces by scrubbing down with steel brushes and cleaning with water to remove toremove all loose dirt/dust and applying roof treatment as below:-- (i) Applying a coat of bitumen primer membrane 0.4ltr/sqm by the same membrane manufacturer of density at 25 degree C’ 0.87-0.89Kg/Litre and viscosity 70-160 CPS till the surface properly impregnates and insolvent oil primer evaporates completely and applying a coat of blown 85/25 graded bitumen confirming to IS 702 @ 1.2 Kg/sqm. (ii) Applying Polymeric Polypropylene polymer membrane “APP” (Atactic poly propylene polymer ) modified prefabricated five layer 3mm thick not less than 3.6 Kg/Sqm with 160 grams/sqm non woven polyster made at centre core reinforced laid with 75 mm side overlap and 100 overlap in length using butane torch with 10cm over laps which shall be thermo fused by flame (iii) Applying course of two coats of aluminium paint over the APP membrane all as specified. All joints and change in direction shall be covered with cement mortar 1:3 mixed with SBR latex @ 200 ml/bag of cement and curved before laying membrane MAKE-IWL/Pidilite
M&L for Cutting out cracks to V-section in existing roofs or terracing etc cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified.
Taking down cement plaster and decayed concrete of any description from roof projection, repair with 15mm thick rendering on fair face of concrete surfaces in CM 1:4 with water proofing compound ( As per manufacturer detail ) including junction portion, making proper slope towards out side, finished even and smooth with PCC 1:2:4 type B-0 (using 12.5mm graded stone aggregate) and provision of two coats of cement based paint and including all necessary scaffolding / safety arrangement for carrying out work on outer side of Double Storey Building complete all as specified and directed. (Note: Water proofing admixture measured and paid seprately)
Supply only Integral water proofing compound liquid
M&L rendering 12 mm thick on fair faces of brick work or concrete surfaces in cm 1:6 finished even and smooth (with out using extra cement) incl taking down cement plaster on brick wall etc. and racking out joints hacking for key
M&L rendering 15 mm thick on other then fair faces of brick work or concrete surfaces in cm 1:4 with water proofing admixture finished even and smooth (with out using extra cement) upto 4th storey with necessary scaffolding incl taking down cement plaster on brick wall etc. and racking out joints hacking for key (Note: Water proofing admixture measured and paid seprately)
M&L Rendering 10 mm thick on concrete surfaces in CM 1:3 finished on even and smooth without using extra cement as in ceiling, Chajja etc.incl taking down cement plaster on RCC Slab etc. and racking out joints hacking for key
M & L Dubbing out average 20 mm thick in CM 1:4 on irregular face of Ceiling all as specified and as directed.
S&F in repair White rotational moulded polyethylene water storage tanks (white colour) with float valve, plastic lid cover, triple layered, cylindrical vertical with closed top hoisted and fixed in position up to 4th storey of capacity 500 ltr incl making connection completed all as specified.
Disconnecting of water tank of 500 ltr capacity ( Upto 4th Storey of Building ) setting aside (or lowering if required) cleaning and removing all scale and dirt etc etc from tanks and from mouths of pipes etc. scrapping silt, scale, fungus with wire brush from water tanks and removing all scale and dirt etc from water tanks and removing water to a distance 50 meters from the building, cleaning the tank with fresh water, cleaning the mouth oh pipe, refixing all G.I fittings and float valve, making functional all out going G.I connections from tanks and float valves and marking the date of cleaning with white paint on tanks for, cleaning and hoisting if required reconnecting and re-fixing in position complete all as specified and as directed.
S&F in repair 20mm stop cock cast cooper alloy of screwed down high pressure with crutch or butter fly handle , screwed with ends for iron pipe or unions. Make ISI marked
S&F in repair 15 mm stop cock cast cooper alloy of screwed down high pressure with crutch or butter fly handle , screwed with ends for iron pipe or unions. Make ISI marked
S&F in repair 25 mm ,Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe or union . Make ISI marked
Supply and fixing in repair float valves high pressure of PTMT with epoxy coated Aluminium rod and high density plastic ball screwed for iron pipe of bore 20mm. ( including necessary fittings)(Min weight 210gm).
S & F G.I. Reducer 25 to 20 mm, complete all as directed
Taking down GI tubing of 20 mm dia and connection and incl cleaning for refixing or removel all as spfd.
Taking up or down 25 or 32 mm steel tubing and connections including clearing for refixing .
S & F Steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) of nominal bore dia 20 mm, complete all as specified and as directed.
S & F Steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) of nominal bore dia 25 mm, complete all as specified and as directed.
Fixing only steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) of nominal bore dia 20 mm, complete all as specified and as directed.
Fixing only Steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) of nominal bore dia 25 mm, complete all as specified and as directed.
Taking down CI/PVC pipes 100 mm dia incl all fittings like bend, branch pieces, connectors, heel rest bend etc all as specified and directed.
Taking down CI/PVC pipes 75 mm dia incl all fittings like bend, branch pieces, connectors, heel rest bend etc all as specified and directed.
S&F PVC (SWR) Type-B pipes single socketed, 110 mm dia, in any length with rubber ring joints, laid in trenches or in floors complete all as specified.
S&F upto 4th storeyof building PVC (SWR) Type-B pipes single socketed, 110 mm dia, in any length with rubber ring joints, on wall complete all as specified.
S&F PVC (SWR) Type-B pipes single socketed, 75mm dia, in any length with rubber ring joints, laid in trenches or in floors complete all as specified.
S&F upto 4th storeyof building PVC (SWR) Type-B pipes single socketed, 75mm dia, in any length with rubber ring joints, on wall complete all as specified.
Taking down and refixing 75 mm & 100 mm bore PVC Pipes upto 4 storey building with necessary clamps , screws , in every 1.00 mtr C/C distance on wall and any vertical position all as specified & directed.
Taking down and refixing 75 mm & 100 mm bore CI Pipes upto 4 storey building with necessary clamps , screws , in every 1.00 mtr C/C distance on wall and any vertical position all as specified & directed.
S&F PVC (SWR) Type-B bends, 75 mm any radius complete all as specified.
S&F PVC (SWR) Type-B bends, 110 mm any radius complete all as specified.
S&F in repair Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified. Make:- Jindal ( JSW)
S&F in repair Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall/ Topi of Topi banglow fixed with self tapping screws as specified complete including scaffolding arrangement all as specified.
S& F 6mm thick asbestos cement corrugated sheets in roofs , walls etc fixed with L type hook or cranked bolts complete all as sped and directed .Make CHARMINAR/EVEREST.
Fixing only 6mm thick asbestos cement corrugated sheets in roofs, walls etc fixed with L type hook or cranked bolts complete all as sped and directed .
Asbestos cement two pieces adjustable plain wing ridge 6mm thick fixed with hook ‘L’ or cranked bolts all as sped . Make; CHARMINAR/EVEREST.
S&F in repair second class hard wood timber scantling framed wrought, complete all as specified and as directed.
Mild steel work as in wind ties including all necessary drilling, bolting and similar work confirming to Fe-410-0 or Fe-310-0 complete, all as specified.
Supply and fixing GI snap grid frame work (Grid size 605cm x 605cm) for false ceiling consisting of main runner 'T' of size 24mm x 32mm and 0.3mm thick , Secondary runner 'T' of size 24mmx25mm and 0.3mm thick,GI angle 24mmx24mm and 0.4mm thick,Bottom exposed capping of width 24 mm of all T-sections shall be of 0.25mm thick PPGI, hot dipped galvanised steel with zink coating not less than 120gm / Sqm ,ceiling grid system duly suspended by 2 mm dia GI wire hanging from existing purlins /roof slab with butterfly clips including Gypsum ceiling tiles of size 595 x 595 x 7 mm laminated with 0.07 mm thick polyvinyl film on the face side and 10 micron metalized polyester film on the back side fixed on GI snap grid complete existing old ceiling boards with cover fillets complete all as specified & directed by Engr-in- Charge.
Preparation of old ,plastered or unplastered surfaces including brooming down or steel wire brushing,scrapping down smokesoot,moulds,moss and efflorescent salts and trading oil greasy spots, and applying one coats of cement base paint on walls
Preparation of new plastered surfaces of wall and applying two coats of cement base paint all as specified and directed.
Preparation of new plastered surface of wall and apply two coat of white wash
Preparation of old plastered surface of wall and apply two coat of white wash
M & L for preparation of old decorated concrete/ plastered surfaces of walls, Pillars, cornices etc by booming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots & rubbing with sand paper and applying two coat of oil bound distemper on old decorated wall surface including necessary filling of wall care putty on uneven surface as and where required.
Preparation of new plastered or unplastered surfaces of walls to achieve smooth and even surface and applying two coats of distemper oil emulsion over and including two coats of wall care putty 1 to 2 mm thick on plastered surfaces,preparatory to distempering complete all as specified and as directed by Engineer-In-Charge.
Preparation of old plastered surface of ceiling and applying two coat of white wash .
Preparation of new plastered surface of ceiling and applying two coat of white wash .
Preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated one coat with creosote , complete allas specified and as directed.
Material and labour for preparation of new plastered/concreat surface of wall, chajja, facia, face of columns, beam etc by booming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots & rubbing with sand paper and applying two coats of weather proof exterior emulsion with necessary scaffoding up to 4th storey, including necessary filling of wall care putty on uneven surface as and where required all as specified.
M/S shakti steel industries
M/S Shesh Paul Gupta
M/S PARAMJEET SINGH
M/S Vishwakarma Builders
CELMAC REGD
M/s Rajesh Mehra
M/S VIJAY KUMAR SHARMA
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .