Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.1 LAccepted-AOC NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L1 | Accepted-AOC L1 | |
| 2 | L2₹42.0 L+₹7.9 L (23.0%)Rejected-AOC NO S 7 2ND CROSS 2ND MAIN KEB LAYOUT SANJAYANAGAR BANGALORE 560094 | BENGALURU URBAN | KARNATAKA | 560094 | L2 | Rejected-AOC L2 | |
| 3 | L3₹44.1 L+₹10.0 L (29.3%)Rejected-AOC | L3 | Rejected-AOC L3 |
Tender Value
₹39.9 L
EMD Value
₹79,760
Closing Date
28 Mar 2020, 6:00 pmClosed
GE (AF) Yelahanka
GE (AF) Yelahanka Bangalore - 63
COMPREHENSIVE MAINT OF DG SETS INCLUDING REPLACEMENT OF DEFECTIVE PARTS AT TECHANICAL AND DOMESTIC AREA AT AF STN YELAHANKA
2020_MES_331303_1
8770/E8
Open Tender
Civil Works
Item Rate
330 days
AFS Yelahanka
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) Yelahanka
₹79,760
Yes
22 Jun 2020
4 Mar 2020
30 Mar 2020
4 Mar 2020
28 Mar 2020
16 Mar 2020
Amount
DOMESTIC AREA Comprehensive maintenance of DG sets including Alternator for routine check up once in a month of the engine for the smooth functioning and carrying out the complete as per the Manufacturers instructions all as specified and directed by the Engineer - in - Charge for 160/200KVA DG sets installed at Dornier FTD & New pump house. Note : Items costing upto Rs.500/- which are not catered in the Sch also part of this check.
A CHECK (every 50 hrs operation or 1 month which ever is earlier) (i) Lubrication/greasing to alt parts (ii) Check engine oil level FUEL SYSTEM (i) Drain sediment from fuel tanks AIR SYSTEM[Every 50 Hrs/1 month whichever earlier) (i) Clean pre cleaner dustpan weakly (ii) Check Air cleaner restriction clean/Change cleaner element if required COOLING SYSTEM i) Check coolant level OTHER MAINTENANCE (i) Drainer tank (ii) Check & correct leaks (iii) Dian fuel filter water fuel filter water separator (iv) Checks belts adjust if required
B - CHECK (Every 250 Hrs operation or Every 6 month which ever is earlier ) (i) Repeat 'A' Lubrication (ii) Changing Engine Oil (iii) Record oil pressure FUEL SYSTEM (i) Check Hydraulic-Governor Oil (ii) Check Throttle Linkage (iii) Lubricate Ball joints of the throttle linkage of Hydraulic, Governor (iv) Change Fuel filter (v)Clean fuel tank breather AIR SYSTEM (i) Clean/Change Crancase Breather (ii) Check Air pipings COOLING SYSTEM (i) Check coolant in radiator (ii) ADD Coolant concentrate if required (iii) Check heat exchanger zinc plugs . Note :- Coolant oil and Engine Oil will bemeasured and paid separetly.
C CHECK (every 400 hrs operation or 1 year which ever is earlier) Repeat 'A' & 'b' check FUEL SYSTEM (i) Change Hydraulic Governor Oil COOLING SYSTEM (I) Clean radiator complete (Inner & Outer) complete opening & refixing (ii) Check fan HUB and water pump OTHER MAINTENANCE (i) Inspect following parts and replace as required (Altemator/Starter- Etc) (ii)Check Air cleaner ALTERNATOR to be carriedout with all checks. (i) Checking AVR for smooth functioning and repairing if required (ii) Bearing to be greased properly as per requirement (iii) Coupling bolts, nuts, rubber to be replaced as per the requirement (iv) All electrical connections to bechecked and insulated with taps etc, properly alternator work to be excuted with every check.
All as per item No 1 above but 100/125 KVA set at Receptorium power house - 02 nos & New pump house. Make: KIRLOSKAR /CUMMINS
A- CHECK(every 50 hrs operation or 1 month which ever is earlier)
B - CHECK (every 250 Hrs operation or Every 6 month which ever is earlier)
C- CHECK (every 400 hrs opeartion or 1 year which ever is earlier)
All asper Item Sl No 1 above but DG set of capacity 50/62.5/63 KVA Installed in IT complex/1&2 Pump house /Receptorium Make: KIRLOSKAR
A check (every 50 hrs opeartion or 1 month which ever is earlier)
B - CHECK (Every 250 Hrs opeartion or Every 6 month which ever is earlier)
C check (every 400 hrs opeartion or 1 year which ever is earlier)
All asper Item Sl No 1 above but DG set of capacity 15/25 KVA Installed in Middle marker/Officers Institute complex. Make : KIRLOSKAR
A check (every 50 hrs opeartion or 1 month which ever is earlier)
B check (every 250 hrs opeartion or 6 month which ever is earlier)
C check (every 400 hrs opeartion or 9 month which ever is earlier)
Supply and changing /Top up of engine oil 15w 40 CH /I grade Makes; VOLVOLINE [CUMMINS]
Supply and add coolant oil in radiator all as directed by Engineer in charge Make -VOLVOLINE [CUMMINS]
Servicing of radiator assembly complete for cleaning, cooling water spaces cleaning the inter cooler and Supply and fix replace u/rubber hose, pipes, irclip,clamps; cleaning of radiator mix .with appropriate cleaning agent, de-scaling by means of scale solvent aswell as neutralizing agent to arrest leakages by means of brazing etc. all as directed by the Engr-in-charge of following capacities:
M&L for servicing of self starter assembly of DG sets 24/12volts of following capacities by disc connecting the self starter assembly from the engine and dismantling, cleaning all accessories, replacing worn-out parts like carbon brushes, bushes, contact plates, jumping levels etc and rewinding the/s field coil and varnishing all as directed by Engr-in-charge. NOTE : Major parts like armature, bentex,field coil, solenoid not inculed will be measured and paid separetly.
Suplying only the following items for self starter assembly of DG set.
Bentex for 200 kva [Make : Delco /130PE]
Armature for 200 kva [Make : Delco /130PE]
Field coil for 200 kva [Make : Delco /130PE]
Solenoid Switch for for 200 kva [Make : Delco /130PE]
Bentex for 100 kva [Make : Lucas TVS]
Armature for 100 kva [Make : Lucas TVS]
Field coil for 100 kva [Make : Lucas TVS]
Solenoid Switch for 100 kva [Make : Lucas TVS ]
Bentex for 40/50/62kva [Make : Lucas TVS]
Armature for 40/50/62kva [Make : Lucas TVS] [Make : Lucas TVS]
Field coil for 40/50/62kva [Make : Lucas TVS]kva [Make : Lucas TVS]
Solenoid Switch for for 40/50/62kva [Make : Lucas TVS or equivalent]
Supply only stopping solenoid coil 12V for 62.5 KVA/15KVA DG set
Supply and fix lead acid battery 180 AH. Make /Amco / Exide/SF
Supply and fix lead acid battery 150 AH. Make /Amco / Exide/SF
Opening the coupling , dismantling the alternator carefully removing the flywheel , dismantling the unserviceable starting gear wheel , supply and fixing new staring gear wheel , fixing back the alternator and properly coupled back all as directed for 100 KVA CUMMINS
All as per item No13 above but 63 KVA DG set
All as per item No13 above but 15 KVA DG set
Supply only Air filter element as per existing make for the following capacities of DG sets
160 /200 kva dg set
125 kva dg set
100 KVA DG SET
50 KVA DG SET
Replacing the faulty water pump assembly with new one suitable for 100 KVA [NTC 495 -G -type ,make:CUMMINS] I/c necessary gaskets and packing …etc.. As required.
Supply only fan belts as per existing make for the following capacities of DG sets
200 /160 kva DG set
125 /100 kva dg set
50/62.5/63 KVA DG SET
Supply and fix Tacho drive meter including cable assembly 1.5 mtr length [0.2000]RPM [Make : KOEL/VDO]
Supply and fix water temp gauge [40 degree C - 120 degreeC] Meehan oil type with accessories [Make : KOEL /VDO/PRICAL]
Supply and fix oil pressure gauge [7/0-10] Kg/Sqm with all accessories [Make : KOEL/VDO]
Supply and replace Brass, Battery terminals suitable for +/- leads of existing size all as specified and directed
Supply and fix Automatic Voltage Regulator for brush type alternator 200 KVA
Supply and fix Automatic Voltage Regulator for brush type alternator 100 / 125 KVA
Supply and fix Automatic Voltage Regulator for brush type alternator 62.5/63/50 KVA
Supply and fix Automatic Voltage Regulator for brush type alternator 15 KVA
supply and fix alternator surge unit for 100 kva
supply and fix alternator surge unit for 62.5 kva
Suply and Fix Anti vibration mounding pads suitable for 62.5 KVA
Suply and Fix Anti vibration mounding pads suitable for 15 KVA
Suply and Fix Oil pressure senser Unit for 100 kva DG set
Suply and Fix High water temparature sensor Unit for 100 kva Dg Set
Suply and Fix Oil pressure senser Unit for 125 kva DG set
Supply and fix Automatic Voltage Regulator for brush type alternator 200 KVA
Suply and Fix Oil pressure senser Unit for 62.5/15 kva DG set
Suply and Fix High water temparature senser Unit for 62.5 kva Dg Set
Replacing the faulty water pump assembly with new one suitable for 125 KVA [6BTA -G -Type ,make:CUMMINS] I/c necessary gaskets and packing etc. As required.
Replacing the faulty water pump assembly with new one suitable for 62.5 KVA [RB -66 -type ,make:KIRLOSKAR] I/c necessary gaskets and packing …etc.. As required.
Repair and servicing of 125 KVA [6BTA] fuel injection pump assembly and by replacing the unserviceable parts like elements , d- valves , plunger springs ,injector nozzles and reassembling testing ...etc as required.
M/L overhauling the 100 KVA DG set [Make : CUMMINS ,Type : 6BTA ] installed at New Pump House ,removing engine from chassis and disconnected the fuel lines and exhaust connections and transported to work shop replacing u/s parts like piston -6 nos, rings 6-set ,cylinder liner -6 nos after cleaning the engine block and fixing the new parts like connecting rod bearing ,cylinder liners- 6 nos, set of joints complete, oil seals , reassembling the engine with new part after assembling cooling the engine , testing and commissioning ..etc as directed .
Removing head assy for overhauling of 160/125 KVA E/A (Cummins ) sets Engine head assy i/c replacing worn out parts like gaskets valve (Inlet/Exhaust) , Guide, inserts,stem seals, oil filter, fuel filters, O rings and head gaskets and grinding, lapping de-carbonizing .. etc and reassembling refixing tappet adjusting etc testing as required.
Repair servicing of 100 KVA PT pump assembly and injectors by replacing the unserviceable parts like centre shaft,loading spring,relief valve -02 Nos bearings,governors barrels & plunger,O rings kits,gasket kits,injector plunger & barrel,ball check and reassembling testing ... etc required
Repair and servicing of Turbocharger asssy and replacing the service kit and reassembling testing ..etc as required.
Supply and fixing the Starter Motor Assembly for 100/125 KVA dg set Make: Lucas TVS , 24 Volt DC
Supply and fixing the Starter Motor Assembly for 100/125 KVA dg set Make: Lucas TVS , 12 Volt DC
Supply and fixing the Starter Motor Assembly for 40/50/63 KVA dg set Make: Lucas TVS , 12 Volt DC
Opening the coupling , dismantling the alternator carefully removing the flywheel , dismantling the unserviceable starting gear wheel , supply and fixing new staring gear wheel , fixing back the alternator and properly coupled back all as directed for 160 KVA Kirloskar
Replacing of damaged water separator fuel filter assembly for 100 KVA Cummins Engine
Supply and Fixing Radiator assembly for 100 KVA DG set Cumkins
TECHNICAL AREA Comprehensive maintenance of DG sets including replacement of defective parts at sub station DG sets installed at Sub Stn No 1 & 112 HU DSS AF Station Yelahanka .[200 KVA - 4 & 250KVA-1] Items of Rs. upto 500/- whom are not catered in the Sch also part of this check Make : CUMMINS/ KIRLOSKAR
A check (every 50 hrs opeartion or 1 month which ever is earlier) (i) Lubrication/greasing to alt parts (ii) Check engine oil level FUEL SYSTEM (i) Drain sediment from fuel tanks AIR SYSTEM[Every 50 Hrs/1 month whichever earlier) (i) Clean pre cleaner dustpan weakly (ii) Check Air cleaner restriction clean/Change cleaner element if required COOLING SYSTEM i) Check coolant level OTHER MAINTENANCE (i) Drainer tank (ii) Check & correct leaks (iii) Dian fuel filter water fuel filter water separator (iv) Checks belts adjust if required
B - CHECK (Every 250 Hrs opeartion or Every 6 month which ever is earlier) (i) Repeat 'A' Lubrication (ii) Changing Engine Oil (iii) Record oil pressure FUEL SYSTEM (i) Check Hydraulic-Governor Oil (ii) Check Throttle Linkage (iii) Lubricate Ball joints of the throttle linkage of Hydraulic, Governor (iv) Change Fuel filter (v) Clean fuel tank breather AIR SYSTEM (i) Clean/Change Crancase Breather (ii) Check Air pipings COOLING SYSTEM (i) Check coolant in radiator (ii) ADD Coolant concentrate if required (iii) Check heat exchanger zinc plugs . Note :- Coolant oil and Engine Oil will be measured and paid separetly.
C check (every 1500 hrs opeartion or 1 year which ever is earlier ) Repeat 'A' & 'B' Lubrication(None) FUEL SYSTEM (i) Change Hydraulic Governor Oil COOLING SYSTEM (i) Clean radiator externaly (ii) Check fan HUB and water pump OTHER MAINTENANCE (i) Inspect following parts and replace as required (Altemator/Starter- Etc) (ii) Check Air cleaner ALTERNATOR to be carriedout with all checks. (i) Checking AVR for smooth functioning and repairing if required (ii) Bearing to be greased properly as per requirement (iii) Coupling bolts, nuts, rubber tobe replaced as per the requirement iv) All electrical connections to bechecked and insulated with taps etc, properly alternator work to be excuted with every check
Comprehensive maintenance of DG sets including Alternator for routine check up of the engine for the smooth functioning and carrying out the complete as per the Manufacturers instructions all as specified and directed by the Engineer - in - Charge for 100 KVA- 02 DG sets installed at 112 HU & 15 Tetra school .KIRLOSKER Model-RB-66 -TA /Greaves , Model: 4G 11 T
A -check (every 50 hrs opeartion or 1 month which ever is earlier) (a) Repeat the daily checks (b) Check oil level in the oil bath type air cleaner © Check the fan belt tension. (d) Check the electrical connection.
B - CHECK(Every 250 hours opeartion or Six month whichever is earlier) (a) Repeat the 'A' Checks (b) Service the oil bath type air cleaner (c) Replace the engine main lub oil filter element & sealing ring (d) Grease the water pump bearing Cleaning the button filter (e) Clean the button filter (f )Drain fuel filler bowls to remove sediments and water (g) Check baltery electrolyte level ,top up with distiIled water,clean terminals and apply petroleum jelly.
C check (Every 400 Hours opeartion or Nine month whichever is earlier) a) Repeat the'B' check (b) Replace the lubricant oil (TC engine for Gen-set application).Old oil should be drained out after warming the engine. (c) Replace the engine and turbocharger lubricant oil filler element and sealing ring (d) Check oil level in the fuel pump and top up if required (e) Drain radiator after warming engine change the water (f) Knock out soot from the exhaust silencer (g) Check and tighten all fasteners to the specified torque (h) Check the tighten all hose connection Check and tighten all Lubricant and fuel connection
All as per item No 50 above but62.5/63KVA set at ATC and TCCF locations [MAKE: KIRLOSKAR RB-66 ]
A check (every 50 hrs opeartion or 1 month which ever is earlier)
B - CHECK (Every 250 Hrs opeartion or Every 6 month which ever is earlier)
C check (every 400 hrs opeartion or 9 month which ever is earlier)
All as per item No 50above but 30 KVA DG set installed at ,CADF [MAKE:KIRLOSKER]
A check (every 50 hrs opeartion or 1 month which ever is earlier)
B check (every 250 hrs opeartion or 6 month which ever is earlier)
C check (every 400 hrs opeartion or 9 month which ever is earlier)
Supply and changing /Top up of engine oil 15w-40w CH/I grade Makes; VOLVOLINE [CUMMINS]
Supply and add coolant oil in radiator all as directed by Engineer in charge Make -VOLVOLINE [CUMMINS]
Repair and servicing of 200 KVA P.T Pump and Injectors by replacing the unserviceable parts like centre shaft, loading spring , relief valve - 2nos, , bearings , govn barrel & plunger , o- ring kits, gasket kit, injector plunger & barrel , ball check and reassembling testing ..etc as required.
Servicing of radiator assembly complete for cleaning, cooling water spaces cleaning the inter cooler and Supply and fix replace u/rubber hose, pipes, circlip,clamps; cleaning of radiator mix .with appropriate cleaning agent, de-scaling by means of scale solvent aswell as neutralizing agent to arrest leakages by means of brazing etc. all as directed by the Engr-in-charge of following capacities:
M&L for servicing of self starter assembly of DG sets 24/12volts of following capacities by disc connecting the self starter assembly from the engine and dismantling, cleaning all accessories, replacing worn-out parts like carbon brushes, bushes, contact plates, jumping levels etc and rewinding the/s field coil and varnishing all as directed by Engr-in-charge.
Suplying following items for above work
Bentex for 200 kva [Make : Delco /130PE]
Armature for 200 kva [Make : Delco /130PE]
Field coil for 200 kva [Make : Delco /130PE]
Solenoid Switch for for 200 kva [Make : Delco /130PE]
Bentex for 100 kva [Make : Lucas TVS]
Armature for 100 kva [Make : Lucas TVS]
Field coil for 100 kva [Make : Lucas TVS]
Solenoid Switch for for 100 kva [Make : Lucas TVS ]
Bentex for 40/50/62kva [Make : Lucas TVS]
Armature for 40/50/62kva [Make : Lucas TVS]
Field coil for 40/50/62kva [Make : Lucas TVS]
Solenoid Switch for for 40/50/62kva [Make : Lucas TVS]
Supply only stopping solenoid coil 12V for 62.5 KVA/30 KVA DG set
Supply and fix lead acid battery 180 AH make /Amco / Exide /SF
Supply and fix lead acid battery 150 AH make /Amco / Exide/SF
Opening the coupling , dismantling the alternator carefully removing the flywheel , dismantling the unserviceable starting gear wheel , supply and fixing new staring gear wheel , fixing back the alternator and properly coupled back all as directed for 100 KVA
All as per item No 63 above but 62.5 KVA DG set
Supply and Fixing of Automatic voltage regulator (AVR) suitable for DG Set 250KVA/200KVA
Supply and Fixing of Automatic voltage regulator (AVR) suitable for DG Set 250KVA/200KVA
Supply only Air filter element as per existing make for the following capacities of DG sets
250 kva dg set
200 KVA DG SET
100 / 125 KVA DG SET
Replacing the faulty water pump assembly with new one suitable for 200 KVA [NTA 743 -G -type ,make:CUMMINS I/c necessary gaskets and packing etc. As required.
Supply only fan belts as per existing make for the following capacities of DGsets
250 kva dg set
200 KVA DG SET
100 KVA DG SET
Supply and fix water temp gauge(40 degree C to 120degree C) Meehan oil type with all accessories. Make : KOEL / VDO / PRICOL
Supply and fix oil pressure gauge (7 - 10) Kg/Sqm with all accessories. Make : KOEL / VDO / PRICOL
Supply and fix techo meter with cable assembly 1.5 Mtr length (0 - 2000) rpm Make : KOEL / VDO
Supply and replace Brass, Battery terminals
Supply and top up of distilled water
Repair servicing of 200 KVA Cummins ,[ model -NTA 743G] PT pump assembly and injectors by replacing the unserviceable parts like centre shaft,loading spring,relief valve -02 Nos bearings,governors barrels & plunger,O rings kits,gasket kits,injector plunger & barrel,ball check and reassembling testing etc required
Repair servicing of 250 KVA Kirloskar , [Model - 8800 TA] Fuel Injection InLine pump assembly and injectors by replacing the unserviceable parts like centre shaft,loading spring,relief valve ' bearings,governors barrels & plunger,O rings kits,gasket kits,injector element, d-valve and reassembling testing etc required
UNIVERSAL ENGINEERING
SRINIVASA ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .