Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical Accepted |
| 2 | Accepted-Technical | Accepted-Technical Accepted |
| 3 | Not Admitted-Fee/PreQual/Technical 103 SECTOR 16 DEEN DAYAL PURA AWAS VIKAS COLONY SIKANDRA AGRA | AGRA | AGRA | UTTAR PRADESH | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹23.8 L
EMD Value
₹48,000
Closing Date
27 Nov 2025, 6:00 pmClosed
Executive Engineer (West) UPSRT Lucknow
Executive Engineer (West), U.P State Road Transport Corporation, Lucknow
Construction of 11kv line and Down Streaming for Opportunity Charges at DWS Kaushambi, Ghaziabad.
2025_UPSRT_1092251_1
1096/B/DA/WTender/2025
Open Tender
Civil Works
Percentage
90 days
Kaushambi Ghaziabad
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,770
Executive Engineer (West) UPSRT Lucknow
₹48,000
16 Dec 2025
19 Nov 2025
28 Nov 2025
19 Nov 2025
27 Nov 2025
19 Nov 2025
Supply & Erection of 11 KV Section Double Pole Structure ( Riser) 11 Mtr. Long SP-72 Type S.T. Pole (Bottom Portion Galvanised) made of following types of supports duly grouted 1:4:8(1 cement, 4 coarse sand and 8 brick ballast 40 mm size) Plinthed, plastered and painted in the same manner as already specified for respective supports with Two nos. MS channels of size 125x65mm fixed with MS Clamp of size 75x10mm and 65x65x6 mm angle iron bracing fixed with MS Clamp of size 50x6mm & 3 no. Pin Insulator, etc. complete with all material and T&P etc. required for proper completion of work. (Only manufacturers whose GTP will be Approved in UP Power Corp.)
Supply, Installation, testing and commissioning of 630 KVA TRANSFORMERS, 3 phase, 50 Hz outdoor type copper wound, delta/star connected (vector group-DYn 11), oil immersed, naturally oil cooled (ONAN), core type Distribution transformer with no load voltage ratio of 11000/415 Volts. The transformer shall be suitable for operation at ambient temperature of 50 deg C and shall be supplied with suitable neutral ternimal on LT side and all accessories such as lifting lugs,breather, Buchholz's relay with alarm and trip contacts, magnetic oil guage, air release valve, oil conservator, dial type temperature indicator, earthing terminals, explosion vent, drain valve with plug inclusive of first filling of oil as per IS 335 (with latest amendents), diagram and rating plate & marshalling box. The transformer shall conform to IS 1180- of level-II in all respects like insulation levels, temperature rise, impedance voltage and losses.
11KV HT-VCB PANEL Supply, Installation, Testing & Commisioning of Indoor type, floor mounted Four breaker cubical panel suitable size fabricated from CRCA steel sheet of 2 mm thick for frame work, enclosures and doors, 3 mm thick for gland plates, dust, damm & vermin proof, IP-4X, fully interlocked, horizontal isolation, extensible type, horizontal draw out, air insulated, metal clad switchboard having single isolation features complete with circuits as detailed below. The switchboard shall be complete with necessary PVC insulated copper busbars, small wiring, labels, cable eyes, cable termination to receive XLPE cables and suitable for operation on 11 kV, 3 phase, 50 Hz, earthed system with a rupturing capacity of 250 MVA at 11KV for 3 Sec as per specification. 1 NO. ICOG BREAKER PANEL EQUIPPED WITH: 1 No. Air insulated metal clad housing 1 set of 3 phase PVC insulated copper busbars 800 Amp rating 6 Nos. single pole cluster type Isolating contacts i.e. plug and switches. 1 No. Triple pole draw out truck mounted 800 Amp, 11 kV Vacuum Circuit Breaker. 1 No. Trip free motor spring charged closing mechanism complete with necessary auxiliary switches, emergency hand trip device and mechanical 'OFF' & 'ON' indicator. 1 No. 24 volt DC shunt trip coil. 1 No. 24 volt DC closing coil. 1 No. 230 volt AC spring charge motor. 3 Nos. Cast resin dual core current transformers of ratio 100A/5A, 15 VA burden Class 5P10 for protection and class 0.5 for metering. 3 Nos. Single Phase cast resin horizontal draw out line potential transformer ratio 11 kV/110 volts, connected delta/star with HV and LV connections, H.V. and L.V. fuses, Isolating plugs for H.V. and L.V. connection. nan 1 set of thermostatically controlled Strip heater to prevent absorption of moisture. nan INSTRUMENT AND RELAY PANEL EQUIPPED WITH: nan for incomming nan 1 No. Triple pole Microprocessor I.D.M.T. overcurrent and earth fault relay, with two outer elements connected for overcurrent and the middle element for earth fault protection, Overcurrent setting 50% - 200%, Earth fault setting 20% -80% and with instantaneous element on all 3 pole settings 500-2000% on overcurrent and 200-800% on earth fault (51, 51N, 50 and 50N) nan 1 No. circuit breaker control switch for electrical (T/N/C). nan 1 No. Master trip relay (86) nan 1 No. Trip circuit suppervision relay (95) nan 1 set of Red/Green indicating lamps for close and open position. nan 1 No. Amber indicating lamp for auto trip. nan 1 No. clear indicating lamp for trip circuit healthy. nan 1 set of white indicating lamps one per phase. nan 1 No. blue indicating lamp for spring charged. nan 1 No. Push button on front door for emergency trip. nan 1 No. cable box suitable for cable termination to receive Incoming and Outgoing 11 kV XLPE Cable 2x3 Core 240Sq. mm. nan 1 No. hooter. nan 1 set of ferrules, control MCBs, limit switch and wiring as required. nan 1 No. Bus Earthing Truck & 1 No. Cable Earthing Truck
Supply/laying of 185 Sqmm 3 core type high conductivity aluminum strand compacted circular conductor XLP (E) armoured 11KV cable neutral earthed system confirming to IS 7098-Part-II(1985) with latest amendment at a depth of 1 Mtr. Below ground level over a cushion of 75mm thick sand around and protect with brick on sides and top of cable shall be properly connecting with the earth conductor by clamps etc. with the cost of all material, labour, T&P etc. required for proper completion of the work. [MAKE:-POLYCAB/GLOSTER/STERLITE/TORRENT/L.S./HAVELL'S/ UNIVERSAL/KEI ONLY AFTER GETTING G.T.P.
S/F of 185 Sqmm End jointing Kit of following sizes outdoor /Indoor MAKE:-RAYCHEM/3M]
Supply and burying of safe earthing Electrode T-39 Zn (Zinc) Coated, Length up to 3000mm, outer pipe 76.3 mm x 3.2mm inner pipe 42.4 mm x 2.6 mm, terminal Dia 12 mm, coating 80-100 micron filled with crystalline conductive mixture (CCM) having anticorrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square C.I. frame with hinged cover & masonry housing. (From electrode terminal to switch board, cost of 25 x 3 G.I. Strip will be extra) Make as per approved in U.P.P.W.D
Providing and fixing G.I. Flat 50 mm X 6 mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run)
Supply/Laying of 300 sqmm 3-1/2 core alluminium conductor PVC insulated armoured served sheathed cables 1100 volts grade at a depth of 750 mm below ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top on surface the cable run shall be fied on M.S. clamps etc. of suitable size or as directed by the Engineer-in-charge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.
Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. i/c Frock wire.
S/L of 150 mm dia. H.D.P.E pipe for drawing of power cable across the road by drilling of 220 mm dia. at 1mtr. below the road level thereby doing the work of providing H.D.P.E pipe by trenchless method PE-63/PN- 6 complete in all respects as per direction of the Engineer in-charge.
Laying 150 mm dia HDPE pipe for HT cable as per specification of UP Power Corp.
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.45 MB
Tender_documentsKaushambi.pdf
Tender Documents • 0.97 MB
BOQ_2006761.xls
BOQ • 3.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .