Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.2 LAccepted-AOC NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹29.1 L+₹4.3 L (17.2%)Rejected-Finance | L2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | L3₹29.5 L+₹4.6 L (18.6%)Rejected-Finance WZ 1000 NANGAL RAYA PANKHA ROAD SOUTH WEST DELHI DELHI 110046 | DELHI | SOUTH WEST DELHI | DELHI | 110046 | L3 | Rejected-Finance BEING NOT LOWEST | |
| 4 | L4₹30.0 L+₹5.1 L (20.7%)Rejected-Finance 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | L4 | Rejected-Finance BEING NOT LOWEST | |
| 5 | L5₹30.9 L+₹6.1 L (24.5%)Rejected-Finance | L5 | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹49.4 L
EMD Value
₹99,000
Closing Date
17 Feb 2020, 6:00 pmClosed
MR. ARIZ AHMED
GE U ELECTRIC SUPPLY DELHI CANTT-10
Repair and Maintenance of electrical breakdown including fault detection localization and rectification in underground 11 KV LT cable network OH conductor and replacement to 11 KV HT cable at Kabul line Baird place CVD Piru Vihar DIPAC HQ TG Kotwal
2020_MES_311745_1
GE ELECT/D-91/2019-2020
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE U ELECTRIC SUPPLY DELHI CANTT-10
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE U ELECTRIC SUPPLY
₹99,000
Yes
13 Mar 2020
22 Jan 2020
19 Feb 2020
23 Jan 2020
17 Feb 2020
6 Feb 2020
Amount
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft/losse soil) for laying of cables or GI pipe and getting out and levelling of bottom suface to required level all as specified and directed by Engineer- in- Charge.
Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified. Note : Measurement shall be taken after punning down.
S&F sub class B bricks having minimum compressive strength 75 Kg/ Sq cm laid in trenches for cable protection etc complete all as directed by Engineer-in-Charge.
Laying only old bricks obtained from excavation complete all as directed.
Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1, flat size 300mmx 180mm x 40mm.
Laying only old HT cable cover obtained from excavation complete all as directed.
Returning filling in,. Including spreading, levelling,. Watering and well ramming soil in layers not exceeding 25 cm thick all as specified and directed.
Removing excavated material (ie soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point all as specified and directed by Engineer-in-Charge.
Testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty 11 KV HT cables of different sizes from both ends, removal of Fault, Re-connections and testing of cables after removal of fault complete all as specified and directed. Note: (a) 11 KV HT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Retrieved old serviceable cable cover/bricks will be laid in trenches for cable protection. If extra PCC cover/bricks and sand required at site shall be measured and paid separately under respective items of BOQs. (c) Excavation and earth work will be measured and paid for seperately under respective items of schedule.
All as per item Ser No 9 above but 1100 Volt LT cables
Supply, laying, jointing, testing and commissioning in replacment LT underground cables 1100 volts grade, PVC insulated XLPE and PVC sheathed, heavy duty armoured, with multistranded aluminium conductors, IS-1554 marked, laid in trenches complete all as specified and directed. Cables of the following sizes:- 10 Sqmm 4 core Note Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately.
All as per srl item No 11 here-in-before but of size 16 Sqmm 4 core
All as per srl item No 11 here-in-before but of size 25 Sqmm 4 core
All as per srl item No 11 here-in-before but of size 35 Sq mm 3.5 core.
All as per srl item No 11 here-in-before but of size 50 Sq mm 3.5 core.
All as per srl item No 11 here-in-before but of size 70 Sqmm 3.5 core
All as per srl item No 11 here-in-before but of size 95 Sqmm 3.5 core
All as per srl item No 11 here-in-before but of size 120 Sqmm 3.5 core
All as per srl item No 11 here-in-before but of size 185 Sqmm 3.5 core
All as per srl item No 11 here-in-before but of size 240 Sqmm 3.5 core
All as per srl item No 11 here-in-before but of size 300 Sqmm 3.5 core
Supply, fixing and testing straight through joint heat shrinkable type with jointing kit suitable for cable PVC/XLPE insulated armoured heavy duty aluminium conductor 1100 Volts grade complete all as directed for the following sizes :- 25 to 50 Sqmm x 3.5 core/ 4 core
All as per item No 22 but size 70 to 150 Sqmm x 3.5 core
All as per item No 22 but size 185 to 240 Sqmm x 3.5 core
Supplying, laying, jointing testing and connecting in replacement XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 11 KV grade, IS 7098 marked, suitable for HT 11 KV(E) system, laid in trenches fixed to pole, including jointing & testing complete all as specified and directed of following sizes:- 95 Sqmm 3 core Note :- Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately.
All as per item No 25 but size 120 sqmm 3 core.
All as per item No 25 but size 185 sqmm 3 core
All as per item No 25 but size 240 sqmm 3 core
All as per item No 25 but size 300 sqmm 3 core
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following size :- 70 Sqmm to 120 sqmm 3 core
All as per item No 30 but size 150 Sqmm to 185 Sqmm, 3 core.
All as per item No 30 but size 240 Sqmm to 300 Sqmm 3 core
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following size:- 70 to 120 Sqmm 3 core.
All as per item No 33 but size 150 Sqmm to 185 Sqmm, 3 core.
All as per item No 33 but size 240 Sqmm to 300 Sqmm 3 core
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following size :- 70 to 120 Sqmm 3 core.
All as per item No 27 but size 150 Sqmm to 185 Sqmm, 3 core.
All as per item No 27 but size 240 Sqmm to 300 Sqmm 3 core
Supply, laying, testing and commissioning in replacement of LT underground cables, 1100 volts grade, PVC insulated XLPE and PVC sheathed, heavy duty armoured, with multistranded aluminium conductors, laid in trenches / ducts / fixed on poles / walls / laid under roads / paths / drain / culverts or encased in GI pipe complete all as specified and directed. Cables of the following sizes:- (a) 400 Sqmm single core
All as per item Sl No 39 above but of size 630 sqmm single core
Taking out faulty underground 1100 Volt LT cable of different sizes by excavation and removing bricks of any size and relaying in the same trenches or re routing after rectification of fault or replacing faulty portion of cable with new cable and removing of surplus soil and using new bricks as required. Note: (a) 1100 Volt LT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Retrieved old serviceable bricks will be laid in trenches for cable protection. If extra bricks and sand required at site shall be measured and paid separately under respective items of BOQs. (c) Excavation and earth work will be measured and paid for seperately under respective items of schedule.
Material and labour for disconnecting faulty/burnt end or portion of cable by removing the cable from loop including necessary excavation & earth work, relaying and reconnecting the cable by removing faulty/burnt portion of cable and preparing fresh terminals with suitable size of thimbles for 25 Sqmm 3.5/4 core to 70 Sqmm 3.5 core of LT cable to LT Panel/pole/main switch complete all as directed.
All as per item 42 above but for LT cable of size 95 Sqmm 3.5 core to 400 Sqmm 3.5 core.
Boring of hole under road/pavement/hard standing or any other situation by mannual means and including GI pipe 100 mm bore (medium grade) and making good both ends all specified and directed
Supply and lay GI pipe light grade in replacement as cable protection laid on trench/floor, fixed on pole/wall etc of following sizes all as specified of size:- 100 mm dia
All as per item No 45 above but of size 80 mm dia
All as per item No 45 above but of size 50 mm dia
M&L for Demolition of path /concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) .complete all as specified and as directed.
M&L for cement concrete type B-2, 1:2:4 (40mm graded stone aggregate) 150mm thick complete all as specified and as directed.
Supplying and fixing in replacement 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections twin core cable of size 16 Sqmm flat complete all as specified ad directed.
All as per Sr item No 91 above but of size 10 Sqmm.
All as per Sr item No 91 above but of size 6 Sqmm.
Material and labour for emergency maintenance work of LT overhead line during breakdown by deploying skilled labour and electricians at faulty site having gang of minimum 4 persons including transportation and other tools and plant required at site for fault rectification. Note:- Contractor or his rep shall come to the site of breakdown within two hours of notification of breakdown. In case the contractor or his rep shall not come to the site of breakdown and start attending breakdown within two hours, a penalty of Rs 500 per fault per hour shall be imposed over contractor and shall be deduct from his dues.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.6 mpa working pressure
Supply and fix in replacement air break switch gang operated tripple pole mechanically operated mechanism, switch air break gang operated mounted on 15 Nos insulator and steel frame with operating rod of 25 mm bore GI Pipe and locking arrangements worked from ground level for current rating 400 Amps, HT 11 KV grade including drop out fuses and necessary silver coper coating jumpers and making all electrical connections complete.
Earthing complete with galvanized steel earth plate electrode of size 60cmx60cmx6 mm thick, buried directly in ground (earth pit not less than 2.25 m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to galvanized lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel as shown in electrical plate No 3 of SSR Part I, connected to earth test point and the equipment on the other nuts and washers of galvanised ironside complete all as specified, including testing and commissioning complete all as directed. Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 15 mm bore GI pipe medium grade etc. (b) The quoted rates shall also deemed to include the cost of earth test point and earth strip/GI lead wire and protection pipe upto 7.5 meter beyond the earth plates electrode.
M & L for 2 coat of aluminium painting over a coat of red oxide to steel surfaces of HT 2/4pole sturcture (Angle Iron/MS channel /MS clamp etc) including preparation of old surface complete all as specified.
All as per Serial item No 31 here-in-before but 6/8 incoming/outoing feeder
Material & Labour for replacement of jumper/bus bar made of ACSR conductor of existing size on HT Four/Six pole structure having 2/3 incoming/outoing feeder including bus bar with PVC sleeve , lugs , nut bolts and washers complete all as directed.
S&F in replacement Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers,welding, bending cold or hot,drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint on 4/6 pole 11 KV HT structure
M & L for cutting and removing grass, vegetation bushes etc from surrounding 4 pole/6 pole HT structure , outside area of HT installation and removing all rubbish to a distance not exceeding 50 m as directed.
Material and labour for sprading of stone aggregate of nominal size not more than 25mm under 4/6 pole HT structure /surounding area of outdoor RMU manually without damaging any equipments, cable or parts , spreading & levelling of finished gravel uniformaly in layers n. ecc. 15 cm thick watered and rammed to true surface all as specified and directed
Suplying and laying as replacement in sub station fixing 3.3 to 11 KV electrical insulation mat of size 5 mtr x 1 mtr x 2.5 mm thick specification as per IS 15652 2006
Supplying and fixing in replacement male contact/moving contact for gang operated air break device 11 KV complete all as directed at site by Engr-in-charge.
Supplying and fixing in replacement female contact /fix contact jaw for gang operated air break device 11 KV complete all as directed at site by Engr-in-charge.
Supplying and fixing in replacement tinned copper flexible jumper 200 Amp/400 Amp for gang operated air break device 11 KV complete all as directed at site by Engr-in-charge.
Supplying and fixing in replacement MS jumper carrier for gang operated air break device 11 KV complete all as directed at site by Engr-in-charge.
Supplying and fixing in replacement back connector plate for gang operated air break device 11 KV complete all as directed at site by Engr-in-charge.
Supplying and fixing in replacement porcelain post insulator for gang operated air break device 11 KV complete all as directed at site by Engr-in-charge.
Supplying and fixing in replacement drop out fuse element 5 to 25 Amp complete all as directed at site by Engr-in-charge.
Supplying and fixing in replacement drop out fuse element 50 Amp complete all as directed at site by Engr-in-charge.
Supplying and fixing in replacement drop out fuse element 60Amp complete all as directed at site by Engr-in-charge.
Supplying and fixing in replacement drop out fuse element 100 Amp complete all as directed at site by Engr-in-charge.
S&F in replacement disc type insulator,porecelain, viterous 145mm high and 255mm dia ball and socket type , brown tow in series assembly for tension with tension clamps for conductors, working presseue 11000 volts complete all as specified and directed.
S&F in replacement pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers,nut size 150 mm height 150mm dia, 11000 volts grade complete all as specified and directed.
S&F in replacement for Danger Notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white , with letters, figures and conventional skull and bobes in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for HT, 25x20 cm size including taking down old one complete all as specified and directed.
S&F in replacement Lightening arrestors expulsion type with all fittings, transmission class, discharge capacity 10 kilo Amps suitable for 11000 volts complete as specified and directed.
Material and labour for Demolition of path /concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed.
Material and labour for Cement Concrete type B-2 mix, 1:2:4 (40mm graded aggregate) 150mm thick, finishing the top surfaces fair and even complete all as specified and as directed.
Dismantling the existing unserviceable (damaged/broken) PCC electric pole of any type and size, from ground after necessary excavation & breaking of concrete foundation & encasing the pole including making good the disturbed surfaces complete all as specified and directed.
Supplying, Errection & Fixing Steel Tubular Pole 410 SP-55 (11 metres long) complete with cast iron base plate all as specified in IS including the followings:- (a) Excavation in post holes in any types of soil, returning filling, well ramming and disposal of surplus soil to a distance not exceeding 50 m from the starting points. (b) Providing PCC (1: 4:8) type D-2 using 40 mm graded stone aggregate as in foundations up to ground level all as specified and directed. (c) Providing PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in foundation including necessary form work for plinth block/collar above GL all as specified and directed. (d) Providing PCC (1:2:4) type B-2 using 20 mm graded stone aggregate as in coping including necessary form work all as specified and directed. (e) Painting of Poles with one coat of aluminium red oxide primer and one coat of aluminum paint before fixing and one coat of aluminum paint after fixing. The complete embedded portion shall be painted with two coats of black bituminus paint.
Re-Adjustment, Cleaning of Contact, greasing and testing of out door type Air break switch 11 KV, current rating upto 400 Amps for desired alignment to smooth operation from ground level and replacement of unserviceable parts in position. Note : Replacement of unserviceable parts shall be measured and paid separately under relevant items, complete all as specified and directed
Supplying and fixing (in replacement) anti climbing device, spikes type, fabricated out of mild steel bars of size 16 Sqmm (round, square and flat) including MS Flat 32x6mm, nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete with and including painting with two coats of aluminium paint over a coat of red oxide primer to match it with existing surfaces complete all as specified and directed.
M&L for painting with two coats of superior aluminium paint including necessary preparation of surfaces of steel fencing by brushing/cleaning complete steel structure/frame/ gate for 11 KV transformer/2 pole to 8 pole structure/ HT panels/Sub Station up to 20 Sqmm arera complete all as specified and directed.
M&L for painting with two coat of superior aluminium paint including necessary preparation of surfaces of steel fencing by brushing/cleaning complete steel structure/frame/ gate for 11 KV transformer/2 pole to 8 pole structure/ HT panels/Sub Station above 20 Sqmm arera complete all as specified and directed.
Material and labour for Pre-cast reinforced cement concrete cover slabs for cable duct of any size, Type B1, 1:2:4 mix (using 20 mm graded stone aggregate) with plain fair faces, and suitable size of carrying handle complete all as specified and directed.
Material and labour for Mild steel bars 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Supplying and fixing (in replacement) 4 mm dia MS wire 75x75mm mesh, made upto into mattress or cages appx 2.00 m height and fixed with flat iron/angle as per existing by welding in position complete all as specified and directed
Material and labour for two coats of synthetic enamel paint of silver colour on steel surfaces over a coat of red oxide primer including preparation of surfaces complete all as specified.
Material and labour for PCC 1:3:6 type C-2, (using 40 mm graded crushed stone aggregate) for foundation, filling and mass concrete etc complete all as specified and directed including dismantling of old unserviciable PCC.
Material and labour Brick work with sub-class 'B' bricks, straight or curved on plane exc 6 m mean radius, built in cement mortar 1:6 complete as specified and directed including dismantling of old unserviciable brick work.
Material and labour Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:4) finished fair and even without using extra cement complete all as specified and directed including
Material and labour for cement concrete type D-2, 1:4:8 (using 40 mm graded crushed stone aggregate) for sub floors, sub-bases, floors and paving etc complete all as specified and directed including dismantling of old unserviciable PCC.
Material and labour for cement concrete type B-1, 1:2:4 (using 20 mm graded crushed stone aggregate) for floors and paving etc complete all as specified and directed including dismantling of old unserviciable PCC.
Material and labour Rubber Mat 2mtrx1 mtr Length, 19 mm thick, 1.1 kV Grade
Supplying and fixing Galvanised iron angle of size 50x50x6mm and 665 mm long with GI clamp 50x6mm including sutable size nuts, bolts and washer for fixing on HT pole for climbing on pole.
Buddham Builders
mayur enterprises
M P TYAGI ENGINEERS AND CONTRACTORS
M/s Birja Nand
MV Engineers And Contractors
Ridhi engineers and builders
DHARYA ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .