| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.4 LAccepted-AOC 107 1F TOLLYGUNGE ROAD KOLKATA 700026 | KOLKATA | KOLKATA | WEST BENGAL | 700026 | L1 | Accepted-AOC Accepted being L1 bidder | |
| 2 | L2₹51.9 L+₹2.5 L (5.06%)Rejected-Finance 5 1B TARA ROAD KOLKATA 700026 INDIA | KOLKATA | WEST BENGAL | 700026 | L2 | Rejected-Finance Being L2 bidder |
Tender Value
₹46.1 L
EMD Value
₹92,160
Closing Date
22 Oct 2024, 6:00 pmClosed
Shri Himanshu IDSE EE
Garrison Engineer (I) (CG) Bhubaneswar, Plot No 190/702, Kokila Residency, 2nd Floor, Anant Vihar, Post-Pokhariput, Bhubaneswar- 751020
REPLACEMENT OF OLD UNSERVICEABLE LIFT AT NEWLY LEASED NEW TRADE CENTRE NO 2 AND PROVISION OF 01 NUMBER LIFT PASSENGER WITH AUTOMATIC DOOR IN TYPE V QUARTERS AT CGRA PARADIP
2024_MES_666983_2
8413BBSR/12/E8
Open Tender
Miscellaneous Works
Item Rate
1200 days
Paradip
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (I) (CG) Bhubaneswar
₹92,160
Yes
11 Mar 2025
26 Sept 2024
24 Oct 2024
26 Sept 2024
22 Oct 2024
5 Oct 2024
Amount
SCH 'A' PART-I (B/R PORTION) Taking down cement plaster on brick or stone wall etc including racking out joints hacking for key scrubbing down with water etc complete all as specified and directed.
M & L for rendering 15mm thick in CM (1:4) on fair faces of brick or concrete surfaces using Liquid water proofing compound of wall including finished even and smooth without using extra cement complete all as specified and directed. (NOTE : WPC Shall be paid and meassured separately)
Supply only Liquid water proofing compound complete all as specified and directed. (Make:Pidillite/Fosroc)
M & L for preparation of new plastered surfaces of wall and applying three coats of white wash complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M& L for PCC Type-B2 (1:2:4)using 40 mm graded aggregate as in foundations .filling and mass concrete complete all as specified and directed.
Demolition of brick work or stone/boulder masonry,built in cement mortar or cement lime mortar including all quoins arches,pillars,etc and remove the debris off the premises outside MD land complete all as specified and directed.
M&L for Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and directed.
Supply, install testing and commissioning of gearless and machine room less electrically operated passenger lift of capacity 10 passenger lift (680 Kgs) in the existing lift well, of size 1.76 mtr x 1.8 mtr (LxW) 1.5 m/s speed with automatic GIEN micro stroke button control microprocessor based controller,full collective control suitable for 3 phases 50 Hz 415 volts AC supply independent operation Alternating Current voltage frequency (ACVF) with micro processor based VVVF control closed loop with power saving regenerative drive with gearless motor unit of capacity as per design to serve ground plus three upper floors (G+3) i.e. with 04 stops and 4 landings(Travel/rise 9.9 M approx) with or without attendant suitable for synchronized operation automatic power operated centre opening fully automatic landing doors in stainless steel Hairline finish of 16 segment display with infra red sensors all along the higher for car door with automatic rescue/levelling device/ automatic evacuation to nearest floor (ARD) with + or – 12 mm) with suitable dry maintenance free batteries haul position digital indicators in car and all landing with call indicating lights etc including necessary arrangement for mounting machine including all civil works required in connection with erection of lifts complete all as specified and directed. Make :Otis Elevators, Mitsubishi, Schindler, Hitachi, Toshiba, Fujitec India Ltd, KONE, Thyssen Krupp, Johnson. The lift shall be provided with and including the following :-
(g) Automatic rescue device (ARD) during power failure including manual operation provision with suitable capacity of battery designed for running the lift with full load.(h) Battery operated emergency light (LED ceiling fitting) alarm (speaker for emergency alarm system to be fixed) and stop button in car with rechargeable arrangement for battery.(j) Decorative ceiling panel light (LED)(k) One sleek circular PVC heavy duty fan in false ceiling make for manufacturer.(l) continuous earting for machine and equipment.(m) Steel wire rope of adequate size as per relevant IS and as per manufacturer specification.(n) Other standard fixtures and fittings like guide rails, sheaves, counter weights with guards, buffers, gear unit brakes control panel, locks governor, car operational panel power control and trailing cables complete.(o) Suitable phase reversal relay shall be provided on the controller to protect lift/equipment against phase reversal, phase failure and low voltage.
Note 2: (a) The bidder to visit the shafts where lift is to be installed. (b) The lift Machine is to be installed above the shaft. (c) Addition alteration to the approach of the lift machines is to be done in the rate quoted. (d) Lift panel and Machine should be easily accessible for repair and Maintenance. (e) Locking arrangement to the lift machine room is to be provided in the rate quoted. (f) defect liability period will be two years from the date of completion / commissioning . (g) Cost of spares required during DLP will be arranged by the contractor. (h) Comprehensive maintenance of the lift during the second year defect liability period is responsibility of the contractor and the quoted rate deemed to be included against this item.
Supply, install testing and commissioning of gearless and machine room less electrically operated passenger lift of capacity 08 passenger lift (544 Kgs) in the existing lift well, of size 1.6 mtr x 1.8 mtr (LxW) 1.5 m/s speed with automatic GIEN micro stroke button control microprocessor based controller,full collective control suitable for 3 phases 50 Hz 415 volts AC supply independent operation Alternating Current voltage frequency (ACVF) with micro processor based VVVF control closed loop with power saving regenerative drive with gearless motor unit of capacity as per design to serve ground plus three upper floors (G+3) i.e. with 04 stops and 4 landings(Travel/rise 10.8 M approx) with or without attendant suitable for synchronized operation automatic power operated centre opening fully automatic landing doors in stainless steel Hairline finish of 16 segment display with infra red sensors all along the higher for car door with automatic rescue/levelling device/ automatic evacuation to nearest floor (ARD) with + or – 12 mm) with suitable dry maintenance free batteries haul position digital indicators in car and all landing with call indicating lights etc including necessary arrangement for mounting machine including all civil works required in connection with erection of lifts complete all as specified and directed. Make :Otis Elevators, Mitsubishi, Schindler, Hitachi, Toshiba, Fujitec India Ltd, KONE, Thyssen Krupp, Johnson. The lift shall be provided with and including the following :-
(g) Automatic rescue device (ARD) during power failure including manual operation provision with suitable capacity of battery designed for running the lift with full load.(h) Battery operated emergency light (LED ceiling fitting) alarm (speaker for emergency alarm system to be fixed) and stop button in car with rechargeable arrangement for battery.(j) Decorative ceiling panel light (LED)(k) One sleek circular PVC heavy duty fan in false ceiling make for manufacturer.(l) continuous earting for machine and equipment.(m) Steel wire rope of adequate size as per relevant IS and as per manufacturer specification.(n) Other standard fixtures and fittings like guide rails, sheaves, counter weights with guards, buffers, gear unit brakes control panel, locks governor, car operational panel power control and trailing cables complete.(o) Suitable phase reversal relay shall be provided on the controller to protect lift/equipment against phase reversal, phase failure and low voltage.
Note 2: (a) The bidder to visit the shafts where lift is to be installed. (b) The lift Machine is to be installed above the shaft. (c) Addition alteration to the approach of the lift machines is to be done in the rate quoted. (d) Lift panel and Machine should be easily accessible for repair and Maintenance. (e) Locking arrangement to the lift machine room is to be provided in the rate quoted. (f) defect liability period will be two years from the date of completion / commissioning . (g) Cost of spares required during DLP will be arranged by the contractor. (h) Comprehensive maintenance of the lift during the second year defect liability period is responsibility of the contractor and the quoted rate deemed to be included against this item.
Supply and fixing of VTPN DB double door,IK 09,IP43-Metal door, 4 way, made of CRCA sheet steel ,RAL 9003,powder coated with bus bar, neutral link, earth bar withprovision for DU125A MCCB,4 pole as incomer and SP/TP MCBs as Outgoings, including taking down old one complete all as specified and directed.( Make - L&T / HPL/Legrand/Havells/C&S
S&F 4 Pole MCCB 125 Amp, 50 Hz, 415 V with rupturing capacity 30 KA/35 KA complete all as specified and directed. Make : L&T/HPL/Legrand/Havells/C&S
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 40 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed. Make:L&T / HPL/Legrand/Havells/C&S
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed. Make:L&T / HPL/Legrand/Havells/C&S
Supply and fixing SPN 32 AMP rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) in the MCB DB complete with connection testing and commissioning complete all as specified and directed. Make:L&T / HPL/Legrand/Havells/C&S
Supply and fixing TPN 40 AMP rating 415V, 10KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning. Make:L&T/Legrand /HPL/Havells/ C&S
S & L of cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 volt grade with stranded aluminium conductor of size 25 Sqmm 4.0 Core. Fixing on wall or surface with fixing arrangement/layered in trenches complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level) with top edge of plate not less than 1.5 Mtr below normal ground level connected to earth lead wire of GI wire 4 mm dia by means of nuts/bolts and washers, check nuts and washer of galvanized iron or steel including 15 mm dia GI pipe light grade upto 1.5 mtr below ground level for protection pipe ,excavation and earth work charcole dust, common salt PCC 1:3:6 type C-I using 20 mm stone aggregate for chamber and MS angle iron frame 40x40x3mm and RCC cover 40 mm thick (1:2:4) type BI using 20 mm graded stone aggregate reinforced with 8 mm dia TMT bars @ 75 mm c/c both ways with MS handle 12 mm dia, round ,PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in Plate no 3 of SSR Part I of 2009 and connected to earth test point incl testing complete all as specified and directed . Note :- Cost of earthing strip & GI pipe 25mm up to 7.5 m shall be included in cost of above item.
Taking Down Old Unserviceable Lift with Complete Accessories complete all as specified and directed.
S & F 4 mm dia GI wire as earth continuity complete all as specified and directed
Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in depth and getting out in soft/loose soil for laying of cables, foundation of poles, and stay assembly complete all as specified and directed.
Supply and filling Sand coarse dry as in cushioning of under ground electric cable in trenches, laid to a uniform thickness of 23 cm (15 cm under the cable & 8 cm over the cable) and gently punned down to 18 cm thickness complete all as specified and directed. Note : Punned thickness will be measured for payment purpose
S&L well burnt sub class ‘B’ bricks (using old size brick) laid in trenches above sand cushioning for cable protection complete all as specified and directed.
Returning, filling in (Soil) including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed.
Removal of excavated soil to a distance not exceeding 50 Mtr depositing where directed at a level not exc 1.5 Mtr above the starting point complete all as specified and directed.
SCH 'A' PART-II (COMPREHENSIVE MAINTENANCE OF LIFT WORK) Comprehensive maintenance, servicing and repairs including renewal/replacement of defective parts for Automatic Rescue Device (ARD) complete with batteries, fan and lights, fully automatic operated 2 Nos lift with automatically operated door i.e. 10 passengers lift (680 Kg) at New Trade Centre No 2 and 8 Passenger lift (544 Kg) at Type-V quarters at Paradip as installaed in this contract for following period :-
(a) AMC on 1st year after expiry of defects liability period of Phase-I.
(b) AMC on 2nd year after expiry of defects liability period of Phase-I.
(c) AMC on 3rd year after expiry of defects liability period of Phase-I.
Note for Sl No 26 : (i) The rate quoted are deemed to include all/any charges related to renewal of lift license and lift insurance from State Govt/other Agency. (ii) The rate is inclusive of all items as requried at site including any spares to keep the lift operated all the time. (iii) The maintenance of the lifts should be done through the OEM. (iv) The contractor should attend the complaint/breakdown immediately. (v) Maintenance of the lift should be done as per manufacturer instructions. (vi) Unit rate quoted is deemed to be inclusive of comprehensive maintenance for two lifts per one month.
Amba Tirupati Zetetic Engg Pvt Ltd (BID ID -3141039)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .