EE PD PWD Shrawasti
EE PD PWD Shrawasti
Installation of New V.C. Room In District Megistrate office in financial year 2026-27 at Shravasti District
2026_CEDPW_1166080_1
1648/E-tender/2026-27 Dated-23/06/2026
Open Tender
Civil Works - Buildings
Fixed-rate
Shravasti
Please refer Tender documents.
2 documents required · 2 mandatory
₹945
₹1.4 L
Yes
Shravasti
9 Jul 2026
3 Jul 2026
9 Jul 2026
3 Jul 2026
9 Jul 2026
3 Jul 2026
4 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead: Of area 3 sq. metres and below 15.12 | 2 | No | 275 | ₹550 |
| 2 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) | 0.69 | Cum | 7,000 | ₹4,830 |
| 3 | 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand) 13.8.2 | 13.58 | Sqm | 305 | ₹4,141.9 |
| 4 | Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. Casement door single panel with zinc alloy (zamak) 3D hinges, multi-point locking system with cylinder, zinc alloy (zamak) powder coated handles on both sides. Using R4 series with frame (64 mm & above) x (55mm & above) & sash (64 mm & above) x (100mm & above). (Height above 2.5 meter). 9.147.F2.2 | 4 | Sqm | 9,100 | ₹36,400 |
| 5 | Float glass panes of nominal thickness 5 mm (weight not less than 12.5kg/sqm). 14.7.2 | 4 | Sqm | 1,050 | ₹4,200 |
| 6 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm | 48.25 | Sqm | 1,175.96 | ₹56,740.07 |
| 7 | Providing and Fixing Knauf Channeled Wood works perforated panels of width 192 mm , thickness of 15 mm and length 2400 mm, made of a Moisture resistant fibre boardsu bstrate witha laminated facing as per the approved shade (Portland Maple , Sea Beech , Siam Wood & Mystique Walnut, Interior White , Alumina Pear l) and a melamine balancing layer on the reverse side. The boards shall have a special perforation pattern where the reverse surfacehas a “Helmholtz” fluted perforation with consecutive 3 mm wide groove followed by 1 /21 mm of visible pane.The edge softhe panel shall be “tongue - and -grooved ”tofix special clips for installation and seamless visual. The back of the perforated panel shall have sound absorbing non-woven acoustical fleece hot pressed to achieve NR C upto 0.6. (Averag evalue of Absorption Co efficient readings taken at 250Hz ,500Hz ,1000 Hzand 2000 Hz ) aspe ASTMC 423 and Humidity Resistance (RH) of 70% with camber limit less than 1 mm/1000 mm and bow less than 1 mm/300 mm. The panels shall be mounted on special aluminium splines (keel) using inside clips provided by Knauf and approved by the Architect/ Engineer-in-Charge. Make : Armstrong | 93 | Sqm | 7,350 | ₹6,83,550 |
| 8 | Providing & Fixing Armstrong Soft Fibre Acoustical Suspended Ceiling System with Optra (Bevelled Tegular/ML) Edge Tiles With Grid. The tiles should have Humidity Resistance (RH) of 95%, NRC 0.9 1.0 , Light Reflectance ≥85%, Colour White, Fire Performance UK Class 0/Class1 (BS476pt-6&7) in module size of 600x600x15 mm , suitable for Green Build in g application, with Recycled content of 66% GW & 74% RW. The tile shall be laid on15mm wide T-section flanges colour white having rotary stitching on all T sections i.e. the Main Runner ,1200mm & 600mm. Cross Tees with a web height of 32 mm and a load carrying capacity of 14Kgs/M2 with a minimum pull out strength of 100 kgs .The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system. Make : Armstrong | 42 | Sqm | 2,500 | ₹1,05,000 |
| 9 | Providing and fixing curtain blinds for window | 16.32 | Sqm | 2,550 | ₹41,616 |
| 10 | Enternal ellectric wiring including false ceiling light switch board etc | 1 | Job | 45,000 | ₹45,000 |
stage.html
html • 0.01 MB
tech_bid_open.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.77 MB
T1.pdf
Tender Documents • 1.25 MB
BOQ_2187152.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .