| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.3 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹24.3 L+₹2.0 L (8.84%)Rejected-Finance GP RAM COLONY AMRITSAR JALANDHAR 144103 | AMRITSAR | AMRITSAR | PUNJAB | 144103 | L2 | Rejected-Finance other then lowest | |
| 3 | L3₹25.5 L+₹3.2 L (14.4%)Rejected-Finance 179 URBAN ESTATE RAM TIRATH ROAD NR GURUDAWARA DARSHAN SINGH AMRITSAR PUNJAB 143001 | AMRITSAR | PUNJAB | 143001 | L3 | Rejected-Finance other then lowest | |
| 4 | L4₹26.4 L+₹4.1 L (18.2%)Rejected-Finance PLOT NO 33 MW INDUSTRIAL AREA PHASE 1 CHANDIGARH CHANDIGARH 160002 UDYAM CH 01 0045211 | CHANDIGARH | CHANDIGARH | 160002 | L4 | Rejected-Finance other then lowest | |
| 5 | L5₹26.7 L+₹4.4 L (19.9%)Rejected-Finance NEAR RAILWAY CROSSING ADAMPUR DOABA JALANDHAR JALANDHAR PUNJAB 144103 | JALANDHAR | PUNJAB | 144103 | L5 | Rejected-Finance other then lowest |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
14 Dec 2019, 6:00 pmClosed
GE AF ADAMPUR
GE AF ADAMPUR
REPAIR TO ROOF TREATMENT IN CERTAIN BUILDINGS IN DOMESTIC CAMP AREA AT AF STN ADAMPUR
2019_MES_297315_1
REPAIR TO ROOF TREATMENT IN CERTAIN BUILDINGS IN D
Open Tender
Civil Works
Item Rate
180 days
GE Af Adampur
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
Yes
₹50,000
4 Jan 2020
13 Nov 2019
16 Dec 2019
13 Nov 2019
14 Dec 2019
27 Nov 2019
13 Nov 2019 - 18 Nov 2019
Amount
Dismantling of brick tiles or terracing tiles laid bedded and pointed in cement mortar in single layer on roofs complete all as specified and directed by Engr-in-Charge.
Demolition of Mud in roofs any thickness, including plastering and leaping etc complete all as specified and directed by Engr-in-Charge.
Cutting out natural vegetation plants grown up on wall or roof including roots in any depth and in any position and making good the damaged portion of wall and roof by PCC 1:2:4 or CM 1:4 to match with the exiting surface of roof and wall complete all as specified and directed by Engr-in-Charge.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specially provided for complete all as specified and directed.
10mm thick rendering in cement mortar 1:4 on concrete surfaces and rendering is to be eve and smooth with water proofing compound as per manufacturers instructions complete all as specified and directed by Engineer-In-Charge
Supply only integral water proofing compound
Preparation of newly plastered / RCC surfaces, making the surface completely dry and applying roof treatment consisting of a coat of cold bitumen primer confirming to IS 3384-1965 @ 0.30 Kg / Sqm and a tack coat of hot blown bitumen 85/25 grade @1.2kg/Sqm and applying APP modified water proofing membrane with non-woven polyester reinforcement, 3 mm thick superior multi polymeric, weighing not less than 3.00 Kg / Sqm with properties of high penetration and centre core consisting of 90 micron high molecular high density polyethylene (MHHDPE) film consisting of five layers, APP shall be laid with torching application and sealing the side as well as end overlaps also with torching application (overlaps shall not be less than10 cms) complete all as specified and as directed by Engineer in Charge. Make : IWL / Multi plast / Hyper plast / Shalimar Tar Products / Shivam Tar Products. Note : (i) Contractor’s quoted rates shall include for necessary over laps which shall be minimum 10 cm both on width & lengthwise complete all as per manufacturer’s instructions. (ii) The work shall be got carried out through authorized applicators of manufacturer for which prior approval shall be obtained from GE.
Cement concrete 1:2:4 type B-1 (20 mm graded crushed stone aggregate) as in coping, roof padding, in roof Kerb or mud stops, water trough and like including weathering, slightly rounded or chamfered angle and throating with necessary form work all as specified and directed.
40 mm thick brick tiles laid on cement mortar, 15 mm thick in 1:6 and joints grouted and pointed in Cement mortar 1:3 mixed with 5% crude oil by weight of cement on APP complete all as specified and as directed by Engineer in Charge.
Description all as per Srl item No 9 here-in before but except tiles.
Demolition of brickwork built in cement mortar including all quoins, arches, pillars, etc., but excluding ashlars facings, dressed stone work and pre-cast concrete articles complete all as specified and as directed by Engineer-in-Charge.
Brick work with sub class ‘B’ bricks, straight or curved on plan to any radius, using old size bricks walls built in cement mortar (1:6) complete all as specified and directed by the Engineer in Charge .
Description all as per Srl item No 12 here-in-before but except bricks.
Taking down cement plaster of any description on brick walls or concrete surfaces etc. including racking out joints, hacking for key, scrubbing down with water complete all as specified and as directed by Engineer-in-charge
15 mm thick rendering on brick / concrete surfaces in cement mortar 1:6 and finished the surfaces even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge.
Taking up and down steel tubing and connections 15 mm bore including cutting chases ,making good the chases etc in cement mortar (1:3) after fixing of pipe complete all as specified and directed. complete all as specified and directed.
Taking up and down steel tubing and connections 20 mm bore including cutting chases ,making good the chases etc in cement mortar (1:3) after fixing of pipe complete all as specified and directed. complete all as specified and directed.
GI tubing 15 mm bore medium grade with necessary GI fittings and fixed complete to wall/ceiling or laid under floors complete all as specified and as directed by the Engineer-in-Charge.
GI tubing 20 mm bore medium grade with necessary GI fittings and fixed complete to wall/ceiling with clips, wall hooks, and wooden plugs etc. or laid under floors complete all as specified and as directed by the Engineer-in-Charge.
Description all as per Srl item No 18 but fixing only GI pipe with new fittings.
Description all as per Srl item No 19 but fixing only GI pipe with new fittings.
Demolition of cement concrete (reinforced) of any description and in any position complete all as specified and directed.
500 Litres capacity rotational moulded polythylene water storage tanks ISI marked three layers construction (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed.
1000 Litres capacity rotational moulded polythylene water storage tanks ISI marked three layers construction (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed.
20 mm ball valves high pressure of PTMT with epoxy coated aluminium rod and high density ball screwed for iron pipe or brass ferrule fixed in repairs completed all as specified and directed.
110 mm PVC (SWR) pipe single socketed in any length with rubber ring joints fixed to walls or laid in trenches or in floor and in sewage soil waste or in rain water including dismantling of old pipes complete all as specified directed. Make FINOLEX, SUPREME, KISAN PRINCE, JAIN
110 mm PVC (SWR) bends any radius any radius with access door fixed in repairs complete all as specified directed.
Disconnecting existing tank exc 250 but not exceeding 500 ltrs capacity, setting aside (or lowering as required) for repairs of roof, cleaning etc. and hoisting if required, refixing and reconnecting the same after roof treatments in the same position complete all as specified and directed.
Disconnecting existing tank exc. 500 but not exceeding 1000 ltrs capacity and removing to store complete all as specified and directed.
Preparation of newly plastered or unplastered surface of wall and applying two coats of exterior emulsion paint complete all as specified and directed by the Engineer-in-Charge.
Preparation of newly plastered or unplastered surface of wall and applying two coats of oil bound distemper complete all as specified and directed by the Engineer-in-Charge.
15 mm thick rendering on brick / concrete surfaces in cement mortar 1:4 and finished the surfaces even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge.
Notes : (i) Amount of credit for retrieved materials is mentioned in Sch 'A' Section-II of tender documents in pdf form which will be deducted while acceptance of tender offline.
AAR KAY BEE ENTERPRISES
M/S MAHAJAN CONSTRUCTION CO
PRITAM SINGH AND SONS
M/S GURBACHAN SINGH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .