| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.7 LAccepted-AOC PLOT NO 46 WARD NO 08 OPPOSITE RADIO TOWER SAGAR ROAD TILAK NAGAR BIKANER 334003 RAJ | BIKANER | BIKANER | RAJASTHAN | 334003 | L1 | Accepted-AOC L1 | |
| 2 | L2₹30.6 L+₹88,892.09 (3.00%)Rejected-Finance | L2 | Rejected-Finance L2 FOR REJECTED | |
| 3 | L3₹30.7 L+₹98,426.59 (3.32%)Rejected-Finance | L3 | Rejected-Finance L3 FOR REJECTED | |
| 4 | L4₹31.4 L+₹1.7 L (5.89%)Rejected-Finance | L4 | Rejected-Finance L4 FOR REJECTED | |
| 5 | L5₹31.5 L+₹1.8 L (6.17%)Rejected-Finance RM 01 RIDHISIDHI I SRI GANGANAGAR 335001 RAJ | SRI GANGANAGAR | SRI GANGANAGAR | RAJASTHAN | 335001 | L5 | Rejected-Finance L52 FOR REJECTED |
Tender Value
Refer Docs
EMD Value
₹47,140
Closing Date
23 Mar 2023, 6:00 pmClosed
CWE SRI GANGANAGAR
HQ CWE POST BOX 48 SRI GANGANAGAR-335001 (Rajasthan)
CA No CWE SGNR TOKEN-52 OF 2022-23 PROVN OF MECHANICAL LAUNDRY 50 KG AT PATIENTS LAUNDRY AREA IN MILITARY HOSPITAL AT SRI GANGANAGAR MIL STATION (3RD CALL)
2022_MES_566103_3
CA NO CWE SGNR T-52 OF 2022-23
Open Tender
Civil Works
Item Rate
180 days
GE SRI GANGANAGAR
AS PER NIT
9 documents required · 9 mandatory
₹500
Yes
GE SRI GANGANAGAR
₹47,140
Yes
29 Mar 2023
11 Mar 2023
25 Mar 2023
11 Mar 2023
23 Mar 2023
18 Mar 2023
Amount
Excavation in trenches, not exc. 1.50 mtr wide and not exc 1.50 mtr in depth and getting out in soft / loose soil for foundations complete all as specified and directed by Engineer - in - Charge.
M & L for PCC (1:4:8) type D-2 ( using 40mm crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed by Engineer - in - Charge.
M&L for form work on flat surfaces, rough finish to sides of concrete foundations, footings, bases of columns, raft beams sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter complete all as specified and directed by Engineer-in-Charge.
M&L for RCC M-25 design mix using 20 mm graded stone aggregate as in foundations, including rafts, footings, foundation beams, plinth beams, base for columns, etc basements slabs under rammed piles and mass concrete complete all as specified and directed by Engineer - in - Charge.
M&L for formwork to sides of pillars Square, Circular rectangular on plan or polygonal posts, struts, piers, columns and stanchions complete all as specified and directed by Engineer - in - Charge.
M&L for RCC M-25 design mix using 20 mm graded stone aggregate as in Columns, pillars, piers, posts and struts complete all as specified and directed by Engineer - in - Charge.
M&L for form work for rough finished flat surface of concret to roof beams, beam haunching, girders, lintals etc. also splays between floors and beem complete all as specified and directed by Engineer - in - Charge.
M&L for RCC M-25 design mix using 20 mm graded stone aggregate as in Beams cantilevers, bressummers lintels over 1.5 m span complete all as specified and directed by Engineer - in - Charge.
M&L for formwork to soffits of suspended slabs such as roof slabs,floor slabs thickness n. exc. 200 mm (horizontal or sloping) in rough finish complete all as specified and directed by Engineer - in - Charge.
M&L for Formwork to edges of concrete flats and similar works thickness n. exc. 200 mm wide in rough finish complete all as specified and directed by Engr-in-Charge.
M&L RCC M-25 (Design Mix) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engr-in-Charge.
S & F TMT bars 10mm dia and over cut to length bent to shape required , incl cranking , bending spirally for hoping for columns , hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer - in - Charge.
As per item No. 12 above but 5mm dia and over upto and including10mm dia as in stirrups, spacers and binders complete all as specified and directed by Engineer - in - Charge.
M&L for brick work with sub class `B` old size bricks straight or curved on plan exceeding 6 mtr mean radius and built in cement mortar (1:4) complete all as specified and directed by Engineer-in-Charge.
M&L 15mm thick rendering in two layers, first coat 10 mm thick and second coat 5mm thick with water proofing compound by weight of 3% of cement layer of brick/concrete surface in CM (1:4) finished even and smooth (with out using extra cement) complete all as specified and directed by Engineer - in - Charge.
Supply only Interal water proofing compound complete all as specified and directed by Engineer - in - Charge.
M&L for 15mm thick rendering in CM (1:6) to brick/ concrete wall surfaces finished even & smooth w/o using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for 5 mm thick rendering in CM (1:3) to concrete surfaces of ceiling surfaces finished even & smooth w/o using extra cement complete all as specified and directed by Engineer - in - Charge.
M & L for preparation of new plastered surfaces of wall and applying two coats of cement base paint over one coat of alkali resistant primer ccomplete all as specified and directed by Engineer - in - Charge.
M&L for preparation of newly plastered surface of wall any description and applying two coats of oil emulsion distemper over 3 mm thick wall putty over a coat of chalk whiting layer on plastered surfaces preparatory to distempering complete all as specified and directed by Engineer - in - Charge.
M & L for three coats of white washing on new plastered surfaces of on ceiling surface including preparation of surface complete all as specified and directed by Engineer - in - Charge.
M&L for Roof treatment to RCC roof as follows:- (a) Cleaning the roof surfaces thoroughly using wire brusehes to remove sharp projections, cleaning joints, washing, drying and removing all dirt/dust to receive concrete padding/plaster etc. (b) Providing 15 mm thick screed bed or bedding layer of cement mortar (1:4) with WPC, finished even and smooth without using extra cement. (c) Providing one coat of approved bituminous primer @100 gms per sqm, over dried plastered surface. (d) Laying 3 mm thick APP membrane,(mineral finish) minimum weight 3kg/sqm reinforced with non woven polyster fabric(weight not less than 150 gms/sqm), by torch application. The overlapping while torching shall be 75 mm on longitudinal direction and 100 mm on the transverse direction complete all as specified and directed by E-in-Charge. Notes:- (i) All joints and change in directions should be covered wih cement mortar (1:3) mixed with SBR latex @ 200 ml/bag of cement/as per site reqmt and cured well before laying membrane by torching. (ii) All angles and abuttments should be sealed well with extra care to ensure full bondage. (iii) Water proofing treatment shall be got carried out by approved authorised applicator of manufacturer only. The name of firm shall be got approved from CWE before carrying out the wk. (iv) The independent testing of membrane for technical parameters given in particular specifications shall be carried out from Govt approved labs having fascilities for testing of membrane. (v) The guarnatee of treatment shall be for min 10 yrs reckoned from date of completion of whole wk. Make :- STP Dr Fixit/Pidilite, Texsa India Ltd/Tikitar Dansona/Bengal Bitumen
M&L for 75 mm thick cement concrete type C-2, (1:3:6) using (40mm graded stone aggregate) as in plinth protection,hard standing finishing even and smooth without using extra cement complete all as specified and directed by Engineer - in - Charge.
M&L for Anti termite Treatment to the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed by Engineer - in - Charge.
M&L for Anti termite Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed by Engineer - in - Charge.
M&L for Anti termite treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed by Engineer - in - Charge.
M&L for Cement concrete Type B1, (1:2:4), using 20 mm gradded stone aggregate as in roof kerbs or mud stops, rounded or chamfered on edges Providing, cement concrete in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed by Engineer - in - Charge.
M&L for earth filling, spreading and levelling in layers n exc. 25 cm thick complete all as specified and directed by Engineer - in - Charge.
M&L for 150 mm thick Hardcore of broken stone or boulders gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer - in - Charge.
M&L for 75 mm thick plain Cement concrete (1:4:8) type D-2, using 40mm graded stone aggregate as in sub base of floor complete all as specified and directed by Engineer - in - Charge.
M&L for machine cut kota stone slab flooring 20-25mm thick (minimum size 55 cm x 55 cm) over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, mirror polishing including 15mm of screed bed in CM (1:6) complete all as specified and directed by Engineer - in - Charge.
Return filling in incl spreding levelling watering and well ramming in layers not exc 25 cm complete all as specified and directed by Engineer - in - Charge.
Removing excavated soil not exc. 50 mtr and depositing where directed at a level n. exc. 1.50 mtr above the starting point complete all as specified and directed by Engineer - in - Charge.
M&L for heat resistance tiles of size 300x300x10mm thick on roof slab of any colour approved over and including 15mm thick screed bed in CM (1:4) technical specification of roof tiles shall be as per IS 4457:2007 complete all as specified and directed by Engineer - in - Charge.
M&L for pressed steel frame for doors of size 125 x 60 mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate complete all as specified and directed by Engineer - in - Charge.
M&L for providing cement concrete (1:3:6) type C1 using 20 mm gradded stone aggregate for filling in pressed steel frames and other similar items complete all as specified and directed by Engineer - in - Charge.
M & L for factory made 35 mm thick second class hard wood plain framed panelled shutters (two number of panells) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both fraces. The size of rail and stile as per IS:1003 (Part1), kiln seasoned and chemically pressure treated complete all as specified and directed by Engineer - in - Charge.
M&L for two coats of synthetic enamel paint over a coat of red oxide on steel surface over 10 cm width or girth, not otherwise described including preparation of new surface complete all as specified and directed by Engineer - in - Charge.
M & L for preparation of new wooden surfaces exc 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed by Engineer - in - Charge.
S& F steel windows with side hung shutters including projecting type hinges with steel handle, tower bolts and steel peg stay complete with glazing bars, dovetailed or welded complete all as specified and directed by Engineer - in - Charge.
S&F galvanized mild steel wire cloth 0.56mm nominal dia of wire and aperture 1.18mm and fixed with tinned tacks or galvanized wire staple complete all as specified and directed by Engineer - in - Charge.
S & F aluminium anodized barrel tower bolts of extruded section 300 mm long complete all as specified and directed by Engineer - in - Charge.
S & F aluminium handle cast type anodized 150 mm long complete all as specified and directed by Engineer - in - Charge.
S&F 300 mm aluminium sliding door bolt with hasp & staple (bolt type) and fixing clip of sheets cast or extruded section and fixing bolt and sliding bolt of extruded section complete all as specified and directed by Engineer - in - Charge.
S&F Grating square 150mm size of PTMT(Minimum weight 50 gms) complete all as specified and directed by Engineer - in - Charge.
S&F PVC(SWR) 75mm bore pipes single socketed in any length witlh rubber ring joints laid in trenches or in floors complete all as specified and directed by Engineer - in - Charge.
S&F PVC (SWR) bend 75mm dia radius complete all as specified and directed by Engineer - in - Charge.
M&L for 75mm dia PVC SWR floor trap, with grating including joining to waste pipe fixed in cement concrete type B-1, (1:2:4) using 20mm gradded stone aggregate complete all as specified and directed by Engineer - in - Charge.
S&F 1000 litres capacity Rotational moulded polyethylene water storage tanks triple layered (Cylindrical vertical with closed top) hoisted and fixed in position including 20 mm dia Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 2 0 m m - 2 1 0 g m s) complete all as specified and directed by Engineer - in - Charge.
S&F 15mm bore GI tubing, 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer - in - Charge.
S&F 20mm bore GI tubing, 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer - in - Charge.
S&F 15 mm bore bib tap cast copper alloy, chromium plated, fancy type with crutch or butterfly handle, approved quality screwed for iron pipe complete all as specified and directed by Engineer - in - Charge.
Supply , install , testing and commissioning of Tumble Dryer 50 to 60 Kg (range) capacity with front loading and open pockets, micorprocessor controlled with automatic cool down feature , stainless steel drum, stainless steel durm have to be programable for forward and reverse roation, self cleaning lint mesh ,minimum dimensions WxDxH in mm (1360X1990X2135) alongwith Hot /steam/cold pipelines, control/starter panels complete with the fwg features and specification :- (a) Minimum Dimensions & capacity- (i) Basket/Drum (Vol-1227 Ltr, Dia-1220mm, Depth-1050mm) (ii) Door Opening (Dia -750mm) (iii) Motor Capacity (2 HP) (iv) Exhaust Motor (2 HP) (v) Inlets sizes as per reqmt (vi) Heater Capacity 27 kW (vii) Steam pressure 4-5 bar (viii) Steam consumption 80 kg/hour
M & L for concealed conduit point wiring complete for light/ fan on independent /combined board with cable 1.5 sqmm (Nominal area) FRLS, PVC insulated multistranded unsheathed copper conductor, drawn in and including PVC Concealed conduit pipe medium grade 20 mm dia, pipe hooks , elbows, juction covers and junction boxes , after cutting in wall chasing for conduits and sinking's for sunken cast iron/ pressed steel terminal boxes suitable length and thickness for mounting, switches, sockets,fan regulator with 3 mm thick plastic laminated sheet cover fixed with brass screwed and cup washers, duly grouting and painted with red oxide metal primer and making the good disturbed surfaces of wall in CM 1:3 with white wash or existing colour including provision of continuous earth continuity conductor along with point wiring of 1.5 sqmm copper PVC insulated cable for one light/ fan point controlled by one switch and connected to common earth dolly, complete all as specified and direced by the Engineer in charge.
All as per Srl item No -56 here in before but for one switch socket combination 5/6 amp on independent board
All as per Srl item No -56 here in before but for one three pin socket outlet 5 Amp on same board with other switches.
All as per Srl item No. 56 here in before but for one switch socket combination 6 pin, 5/ 15 Amps on independent board with copper conductor 2.5 Sqmm complete all as specified and directed by Engineer - in - Charge.
S & F switch socket combination 5 pin, type 5/6 Amps flush type complete all as specified and directed by Engineer - in - Charge.
S & F switch socket combination 6 Pin, 5/16 Amps flush type complete all as specified and directed by Engineer - in - Charge.
S & F Socket outlet 5 pin, 5 Amps flush type complete all as specified and directed by Engineer - in - Charge.
S & F ceiling rose surface bakelite three terminals complete all as specified and directed by Engineer - in - Charge.
S & F switch piano flush type 5/6 Amps single pole one way complete all as specified and directed by Engineer - in - Charge.
S&F LED lamp 9W for angle holder complete all as specified and directed by Engineer - in - Charge.
S & F Tube light fitting with LED batten with aliminium housing and integrated electronic driver, 20 watt having input voltage AC90-300V, 50 Hz , 6500K, and all other accessories including connection with flexible cable copper conductor twin core of size 23/.2 mm upto ceiling rose/connector complete all as specified and directed by Engineer - in - Charge. Make:Havells cat part No: LUMILINEPLUSBS20WLED865SPCSS, Bajaj cat part no.: BCLSBAL 20W CW ,Crompton cat part No. : CCS-100-20-65-HL2-DP-NWH)
S&F security light fitting LED TYPE 25 watt with all necessary acessories, Clear transparent acrylic cover, prewire suitable to operated on 230 volt 50 HZ AC & Supply and fixing to wall / on pole including fixing arrangement with suitable galvanized iron pipe 35 mm bore “light grade” brackets 2 mtr length bent to shape to obtained required shape including clamps, nuts / bots / washers etc connecting with suitable flexible copper wire of size 23/0.0076 complete all as specified and directed by Engineer - in - Charge. Make:Havells cat part no: ENDURAPEARLSL25WLED757SASYTOPCMP, Bajaj cat part no. BRLEP 25W LED WH, Crompton cat part No. LSTS-25-CDL-M.
S & F Water tight bulk head fitting,comprision of connector galvanised cast iron back plate,weather proof enamelled gallery ,glass well,and including 10 watt LED lamp all as specified and directed by Engineer - in - Charge. Make:Havells cat part no : HEXAFT10WLED857SSYMBOPC, Bajaj cat part no. BIBWP 10W LED, Crompton cat part No. LBHP-10-CDL.
Supply and fixing ceiling fans complete with blades , down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE five star ratedwith brushless direct current motor (BLDC) all as specifiend and directed by Engr-in-Charge.
S & F stepped type,single socket fan regulator for ceiling fan 1200/1400mm sweep complete all as specified and directed by Engineer - in - Charge
Supply and fix heavy duty meatal body Exhaust fan 300mm sweep complete with frame , louvers, nuts bolts etc all as direceted.by Engineer - in - Charge.
S & F Sub-main wiring with two single core cables PVC insulated and un-sheathed 6 sqmm (Nominal Area) FRLS stranded copper conductor drawn in concealed PVC conduit dia 20mm “medium quality” conduit including 6.00 Sq mm (Nominal Area) copper cable as earth continuity conductor after chasing in wall and making good the disturbed surfaces and white wash or existing colour , necessary junction box and covers including necessary connections, PVC flexible pipes are used in pannel board while connecting the cable complete all as specified and directed by Engineer - in - Charge. Note: (i) PVC cable and PVC conduit shall be ISI marked) (ii) Three run of 6 sqmm wire and PVC conduit shall be measured as one Run
S & F sheet metal enclosure for double door DB made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted SP & N 8 ways, 240 Volts, ISI marked, 200 Amps bus bar stove enameled dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed by Engineer - in - Charge.
S&F Sheet metal enclouser for doble door Vertical DBs made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mouting VTPN 4 Way 415 Volt ISI marked 300 Amps busbar stove enameled dust and vermin proof,IP:43 protection suitable for incorporation FP MCCB(V-Tech) N1 Frame upto 125A ,Isolators and including give connection with wire and cable etc complete all as specified and directedby engineer -in-charge.
S&F MCCB TP&N 100 Amps with breaking capcity 16kA ,Fixed TM and 415 volts AC Supply ISI marked complete all as specified and directed by Engineer - in - Charge.
S & F MCB ‘B’ series type suitable for 240 volts, AC supply 5 to 40 Amps , single pole with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in - Charge.
S & F MCB ‘B’ series type suitable for 240 volts, AC supply 5 to 40 Amps, S P & N with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in - Charge. Make:- Havells / Standard / Indo Asian
M & L for sand cushioning with dry and clean locally available sand for underground cable 8cm before laying cable and 15 cm after laying cable and punned to 18 cm after laying of cable complete all as specified and directed by Engineer-in-Charge. (Note: Pressed thickness shall be considered for payment purpose)
Supply and laying well burnt clay brick old size class 'B' laid dry flat for cable protection over the cable, length of bricks shall accorss the length of cable complete all as specified and directed by Engineer - in - Charge.
Supplying,laying, jointing and testing and commissioning 25 Sqmmx4 core XLPE insulated, screened , PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty multi stranded aluminium conductor & PVC sheathed LT cable 1100 V grade conforming to IS-7098 laid in trenches/ducts/fixed on poles wall/laid under roads/paths/drain/culverts or passing through pipes complete all as specified and directed by engineer in charge.
M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to 4mm dia GI wire and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 15mm dia upto earthing test point and watering pipe 20mm dia GI medium grade with socket and plug 30 cm above ground level including earthwork, PCC chamber in PCC (1:3:6) type C-2 using 40mm stone aggregate, cast iron cover, wire meah etc all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 complete and all as specified and direcrted by Engr-in-charge. Notes:- (i) 20 mm dia GI pipe for watering to be provided with a socket and plug and should be 30 cms above ground level. (ii) GI wire connecting upto pump,Gen set,LT panel and DBs earth connection or earthing test point is included in this item. (iii) GI pipe 15 mm dia protection pipe shall be provided upto earthing test point .
Dashmesh Construction Company
Engineers CXonstruction Company
ram rattan dass aggarwal
KHANNA CONSTRUCTIONS
Soma Enterprises
M/s Karan Builders
THAKURJI ENTERPRISES
Lalgarhia Enterprises
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .