Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.2 LAdmitted-Finance B 1015 GREENFIELD COLONY SECTOR 42 FARIDABAD HARYANA 121010 | FARIDABAD | HARYANA | 121010 | ₹5.2 L | L1 | Admitted-Finance |
| 2 | L2₹5.4 L+₹23,730 (4.57%)Admitted-Finance | ₹5.4 L+₹23,730 (4.57%) | L2 | Admitted-Finance |
| 3 | L3₹5.5 L+₹31,450 (6.06%)Admitted-Finance C 3 LAKHAN SONA NEAR RPS MORE BAILEY ROAD PATNA BIHAR PIN 801503 | PATNA | BIHAR | 801503 | ₹5.5 L+₹31,450 (6.06%) | L3 | Admitted-Finance |
| 4 | Rejected-Technical A 1165 24 SHRI RAM COLONY RAJIR NAGAR DELHI 94 | 940000 | - | - | Rejected-Technical As the firm not fulfills all the parameters of NIT hence recommended to Disqualify for next stage. |
| Sl No | Description | Qty | Unit | SHIV VIJAY ENGICON PRIVATE LIMITED L3 | Vibrant Enterprises L1 | HABRICK COMPANY L2 |
|---|---|---|---|---|---|---|
| 1.00Concrete | ||||||
| 2.00 | Fabrication, Installation, Testing and Commissioning of double door with locking arrangement front openable, totally enclosed, compartmentalized, dust, vermin proof and outdoor type Meter Panel (IP54) fabricated out of 2 mm/1.6mm thick cold rolled close annealed sheet steel for Load/Non Load bearing members, with 250 Amp 4 strip Copper bus bar, powder coated paint of approved shade after 7 tank treatment process with following switchgears,making connections/ inter connections with lugs/ thimble for switch gears, Viewing Glass for Meter Reading purpose including providing 50mm X 50mm X 6 mm thick MS Angle with four legs to keep the Feeder Pillar upto 600 mm above ground level and 300mm grouted in cement concrete 1:2:4.(as per TNEB/TANGEDCO Standards.) Panel Size-(1350 mm x 1500 mm x 400 mm) with Bus Bar 250 Amp TPN aluminium spreader link.(Drawing shall be got approved from Engineer in charge before fabrication ,MCCB'S lcs=100% lcu) | 1 | Each | 70,000 ₹70,000 | 80,000 ₹80,000 | 68,000 ₹68,000 Lowest |
| 3.00 | Fabrication, Installation, Testing and Commissioning of double door with locking arrangement front openable, totally enclosed, compartmentalized, dust, vermin proof and outdoor type Meter Panel (IP54) fabricated out of 2 mm/1.6mm thick cold rolled close annealed sheet steel for Load/Non Load bearing members, with 250 Amp 4 strip Copper bus bar, powder coated paint of approved shade after 7 tank treatment process with following switchgears,making connections/ inter connections with lugs/ thimble for switch gears, Viewing Glass for Meter Reading purpose including providing 50mm X 50mm X 6 mm thick MS Angle with four legs to keep the Feeder Pillar upto 600 mm above ground level and 300mm grouted in cement concrete 1:2:4.(as per TNEB/TANGEDCO Standards.) Panel Size-(1775 mm x 900 mm x 500 mm) with Bus Bar 250 Amp TPN aluminium spreader link.(Drawing shall be got approved from Engineer in charge before fabrication ,MCCB'S lcs=100% lcu) | 1 | Each | 61,000 ₹61,000 Lowest | 75,000 ₹75,000 | 61,000 ₹61,000 Lowest |
| 4.00 | Fabrication, Installation, Testing and Commissioning of double door with locking arrangement front openable, totally enclosed, compartmentalized, dust, vermin proof and outdoor type Meter Panel (IP54) fabricated out of 2 mm/1.6mm thick cold rolled close annealed sheet steel for Load/Non Load bearing members, with 250 Amp 4 strip Copper bus bar, powder coated paint of approved shade after 7 tank treatment process with following switchgears,making connections/ inter connections with lugs/ thimble for switch gears, Viewing Glass for Meter Reading purpose including providing 50mm X 50mm X 6 mm thick MS Angle with four legs to keep the Feeder Pillar upto 600 mm above ground level and 300mm grouted in cement concrete 1:2:4.(as per TNEB/TANGEDCO Standards.) Panel Size-(1200 mm x 900 mm x 450 mm) with Bus Bar 250 Amp TPN aluminium spreader link.(Drawing shall be got approved from Engineer in charge before fabrication ,MCCB'S lcs=100% lcu) | 1 | Each | 54,500 ₹54,500 | 52,000 ₹52,000 Lowest | 54,100 ₹54,100 |
| 5.00 | Providing, fixing testing and commissoning of 250 Amp 3Pole 36 kA MCCB | 3 | Each | 35,500 ₹1,06,500 | 27,900 ₹83,700 Lowest | 35,000 ₹1,05,000 |
| 6.00 | Providing, fixing testing and commissoning of 100 Amp 3Pole 25 kA MCCB | 8 | Each | 13,000 ₹1,04,000 | 10,000 ₹80,000 Lowest | 12,800 ₹1,02,400 |
| 7.00 | Providing, fixing testing and commissoning of 100 Amp 2 Pole 25 kA MCCB | 15 | Each | 7,410 ₹1,11,150 | 4,000 ₹60,000 Lowest | 7,350 ₹1,10,250 |
| 8.00 | Providing, fixing testing and commissoning of ROH | 12 | Each | 1,600 ₹19,200 | 4,000 ₹48,000 | 1,560 ₹18,720 Lowest |
| 9.00 | Providing, fixing testing and commissoning of Metering | 6 | Each | 1,450 ₹8,700 | 2,000 ₹12,000 | 1,410 ₹8,460 Lowest |
| 10.00 | Providing, fixing testing and commissoning of MF Digital | 3 | Each | 5,200 ₹15,600 | 9,500 ₹28,500 | 5,000 ₹15,000 Lowest |
Tender Value
₹5.6 L
EMD Value
₹11,128
Closing Date
3 Sept 2026, 12:30 pmClosed
Commandant 194 RAF
194 RAF ,Bawana, New Delhi-110039
Repairing/Replacement of 03 Nos HT/LT Electric Main Feeder panel at HQ/194 RAF,Bawana,New Delhi
2026_CRPF_924090_1
B.V/2026-27-194-Bldg (NIT-05) Dated 21/08/
Open Tender
Electrical Works
Item Rate
60 days
HQ 194 RAF Bawana New Delhi Pin 110039
Please refer Tender documents.
16 documents required · 16 mandatory
₹0
₹11,128
15 Sept 2026
29 Aug 2026
4 Sept 2026
29 Aug 2026
3 Sept 2026
29 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Concrete | - | - | - | - |
| 2 | Fabrication, Installation, Testing and Commissioning of double door with locking arrangement front openable, totally enclosed, compartmentalized, dust, vermin proof and outdoor type Meter Panel (IP54) fabricated out of 2 mm/1.6mm thick cold rolled close annealed sheet steel for Load/Non Load bearing members, with 250 Amp 4 strip Copper bus bar, powder coated paint of approved shade after 7 tank treatment process with following switchgears,making connections/ inter connections with lugs/ thimble for switch gears, Viewing Glass for Meter Reading purpose including providing 50mm X 50mm X 6 mm thick MS Angle with four legs to keep the Feeder Pillar upto 600 mm above ground level and 300mm grouted in cement concrete 1:2:4.(as per TNEB/TANGEDCO Standards.) Panel Size-(1350 mm x 1500 mm x 400 mm) with Bus Bar 250 Amp TPN aluminium spreader link.(Drawing shall be got approved from Engineer in charge before fabrication ,MCCB'S lcs=100% lcu) | 1 | Each | - | - |
| 3 | Fabrication, Installation, Testing and Commissioning of double door with locking arrangement front openable, totally enclosed, compartmentalized, dust, vermin proof and outdoor type Meter Panel (IP54) fabricated out of 2 mm/1.6mm thick cold rolled close annealed sheet steel for Load/Non Load bearing members, with 250 Amp 4 strip Copper bus bar, powder coated paint of approved shade after 7 tank treatment process with following switchgears,making connections/ inter connections with lugs/ thimble for switch gears, Viewing Glass for Meter Reading purpose including providing 50mm X 50mm X 6 mm thick MS Angle with four legs to keep the Feeder Pillar upto 600 mm above ground level and 300mm grouted in cement concrete 1:2:4.(as per TNEB/TANGEDCO Standards.) Panel Size-(1775 mm x 900 mm x 500 mm) with Bus Bar 250 Amp TPN aluminium spreader link.(Drawing shall be got approved from Engineer in charge before fabrication ,MCCB'S lcs=100% lcu) | 1 | Each | - | - |
| 4 | Fabrication, Installation, Testing and Commissioning of double door with locking arrangement front openable, totally enclosed, compartmentalized, dust, vermin proof and outdoor type Meter Panel (IP54) fabricated out of 2 mm/1.6mm thick cold rolled close annealed sheet steel for Load/Non Load bearing members, with 250 Amp 4 strip Copper bus bar, powder coated paint of approved shade after 7 tank treatment process with following switchgears,making connections/ inter connections with lugs/ thimble for switch gears, Viewing Glass for Meter Reading purpose including providing 50mm X 50mm X 6 mm thick MS Angle with four legs to keep the Feeder Pillar upto 600 mm above ground level and 300mm grouted in cement concrete 1:2:4.(as per TNEB/TANGEDCO Standards.) Panel Size-(1200 mm x 900 mm x 450 mm) with Bus Bar 250 Amp TPN aluminium spreader link.(Drawing shall be got approved from Engineer in charge before fabrication ,MCCB'S lcs=100% lcu) | 1 | Each | - | - |
| 5 | Providing, fixing testing and commissoning of 250 Amp 3Pole 36 kA MCCB | 3 | Each | - | - |
| 6 | Providing, fixing testing and commissoning of 100 Amp 3Pole 25 kA MCCB | 8 | Each | - | - |
| 7 | Providing, fixing testing and commissoning of 100 Amp 2 Pole 25 kA MCCB | 15 | Each | - | - |
| 8 | Providing, fixing testing and commissoning of ROH | 12 | Each | - | - |
| 9 | Providing, fixing testing and commissoning of Metering | 6 | Each | - | - |
| 10 | Providing, fixing testing and commissoning of MF Digital | 3 | Each | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.02 MB
BOQ_971066.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .