Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.7 LAccepted-AOC 1 1 A VANSATTART ROW 3RD FLOOR ROOM NO 2A | ₹47.7 L | L1 | Accepted-AOC L1 |
| 2 | L2₹47.9 LRejected-Finance 1 1A VANSITART ROW 2ND FLOOR ROOM NO 2 KOL 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | ₹47.9 L | L2 | Rejected-Finance higher than L1 |
| 3 | L3₹48.2 LRejected-Finance 1 71 SREEMANTA DEY LANE KOLKATA 700012 W B | KOLKATA | KOLKATA | WEST BENGAL | 700012 | ₹48.2 L | L3 | Rejected-Finance higher than L1 |
| Sl No | Description | Qty | Unit | JDJ ENTERPRISE. A UNIT OF JDJ TRADERS PRIVATE LIMITED L1 | ALOK ENTERPRISE. A Unit of Saket Trexim Pvt. Ltd. L2 | ORIENTAL ENGINEERING CO. L3 |
|---|---|---|---|---|---|---|
| 1.00 | Dismantling of the whole water treatment plant unit from the truck and thereafter installation and commissioning of the whole water Treatment Plant including change of pipelines of 1 ½’ CVPC pipes of quantity 100 ft approx including replacement of valve and repairing of the skid etc as per full satisfaction of the EIC to get the production of 4000pouches per hour | 1 | Item | 7,65,917 ₹7.7 L | 7,70,000 ₹7.7 L | 7,74,800 ₹7.7 L |
| 2.00 | Repairing of the whole body of the truck including the base of the body to be replace by MS Plate of minimum 5 mm thickness to accommodate the new generator and water treatment plant inside of the truck including complete paint and polishing of the whole body of the MTU and write the matter on all the four side of the truck including supply of the materials as per existing design and as per direction of EIC | 1 | Item | 9,02,523 ₹9.0 L | 9,05,000 ₹9.1 L | 9,10,600 ₹9.1 L |
| 3.00 | UF unit for removing all undisclosed impurities including suspended solids, colidall impurities having Feed Pressure-5 Bar, Operating Tran membrane Pressure -2 psig, Maximum Backwash- 20 psig as per following specification:-
a) Filtrate Flow- 12.1-29.5 gpm 2.7-6.7m³/hr)
b) Filtrate Turbidity-≥00.7 NTU
c)Virus removal-≥ 4 log
d) Bacteria removal-≥ 4 log
e) Configaration :- Capillary Ultrarafitration Module
f) Membrane Polymar:- Hydrophilic Poly thersulfone
g) Nominal Membrance Area :- 500 ft²(46m² ) or above
h) Fiber Dimensions- ID 0.031" (0.8mm) OD 0.055" (1.4mm)
i) Pore size:- 0.02 micron or less
j) Typical Filtrate Flux Range:- 35-85 gfd (59-145l/m²/h)
k) Maximum Applied Feed Pressure. 73 psig (5bar)
l) Maximum Transmenibrane Pressure - 20psig (1.4 bar)
m) Maximum backwash transtnembrance Pressure :- 20 usig (1.4 bar)
n) Instantaneous Chlorine Tolerance :- 100 ppm
o) Instantaneous Hydrogen Peroxide Tolerance :- 200 ppm**
p) maximum chlorine Expossure :-200.000ppm-hrs
q) maximum instantaneous Feed Turbidity :- 100 NTU
r) Maximum Operating Temperature:- 104° F
s) pH operatin range:- 4.0-10.0
t) Clraning pH Range- 1.5-13.0
u) Operating Mode:- Inside to Outside Filtration Direct flow of Crossflow. | - | - | - | - | - |
| 3.10 | v) Backwash flux-100-150 gfd (170-255 l/m²/hr)
w) Backwash Duration -30-60 seconds.
x) Backwash Frequency-20-60 minutes.
y) Chemical Enhanced Backwash Frequrncy-0-4 ties per day
z) Chemical Enhanced Backwash Duration-1-30 minutes
z1) Disinfection Chemicals -Na0CL, H₂o₂, CLO₂, or , NH₂CL
z2) Cleani9ng Chemicals -NaOH, HCL, H₂SO₄, or Citric Acid
(Make- Suez/Dow/Toray) | 2 | Each | 6,89,385 ₹13.8 L | 6,90,000 ₹13.8 L | 6,95,600 ₹13.9 L |
| 4.00 | Installation and Commissioning of UF unit for removing all undissolved impurities including suspended solids, colidall impurities having Feed Prussure-5 Bar. . (Supplied by Departmentally) | 2 | Each | 22,538 ₹45,076 | 22,600 ₹45,200 | 22,700 ₹45,400 |
| 5.00 | Supply and delivery of Skid mounted Ozonator of capacity 6 gm/hr. | 1 | Each | 7,75,048 ₹7.8 L | 7,80,000 ₹7.8 L | 7,82,000 ₹7.8 L |
| 6.00 | Supply, delivery & Installationof 500 lit capacity PVC Tank (Rectrangular Shape, White Color) for storage of Water of different stages. | 3 | Each | 15,297 ₹45,891 | 15,300 ₹45,900 | 15,435 ₹46,305 |
| 7.00 | Making new internal wiring and fettling illumination arrangement inside the MTU unit as per requirement and making distribution of electric line from DG set to PDB inside of MTU for reorientation of pouch packing machine including servicing of electrical panel as per direction of EIC | 1 | Item | 47,931 ₹47,931 | 48,000 ₹48,000 | 48,360 ₹48,360 |
| 8.00 | Servicing of 25 KVA Diesel Generator set due to including replacing of mobile filter and diesel filter etc. | 1 | Item | 13,658 ₹13,658 | 13,700 ₹13,700 | 13,780 ₹13,780 |
| 9.00 | Deployment of daily service charges of the service engineer with all conveyance fooding and accommodation for the Restoration of the breakdown of Mobile Treatment Unit - Balurghat | 4 | days | 7,649 ₹30,596 | 7,670 ₹30,680 | 7,700 ₹30,800 |
Tender Value
Refer Docs
EMD Value
₹1.1 L
Closing Date
17 Oct 2025, 1:00 pmClosed
Executive Engineer Electrical Divn PHED
P16 India Exchange Place CIT Annexe Bldg Extn 2nd floor Kol 73
E/M works
2025_PHED_912007_9
WBPHED / EE / ED / 13 / 2025-26
Open Tender
Electrical Work/ Equipment
60 days
Office of the Executive Engineer ED PHED
Please refer Tender documents.
5 documents required · 5 mandatory
₹1.1 L
6 May 2026
26 Sept 2025
24 Oct 2025
26 Sept 2025
17 Oct 2025
26 Sept 2025
Amount
Dismantling of the whole water treatment plant unit from the truck and thereafter installation and commissioning of the whole water Treatment Plant including change of pipelines of 1 ½’ CVPC pipes of quantity 100 ft approx including replacement of valve and repairing of the skid etc as per full satisfaction of the EIC to get the production of 4000pouches per hour
Repairing of the whole body of the truck including the base of the body to be replace by MS Plate of minimum 5 mm thickness to accommodate the new generator and water treatment plant inside of the truck including complete paint and polishing of the whole body of the MTU and write the matter on all the four side of the truck including supply of the materials as per existing design and as per direction of EIC
UF unit for removing all undisclosed impurities including suspended solids, colidall impurities having Feed Pressure-5 Bar, Operating Tran membrane Pressure -2 psig, Maximum Backwash- 20 psig as per following specification:- a) Filtrate Flow- 12.1-29.5 gpm 2.7-6.7m³/hr) b) Filtrate Turbidity-≥00.7 NTU c)Virus removal-≥ 4 log d) Bacteria removal-≥ 4 log e) Configaration :- Capillary Ultrarafitration Module f) Membrane Polymar:- Hydrophilic Poly thersulfone g) Nominal Membrance Area :- 500 ft²(46m² ) or above h) Fiber Dimensions- ID 0.031" (0.8mm) OD 0.055" (1.4mm) i) Pore size:- 0.02 micron or less j) Typical Filtrate Flux Range:- 35-85 gfd (59-145l/m²/h) k) Maximum Applied Feed Pressure. 73 psig (5bar) l) Maximum Transmenibrane Pressure - 20psig (1.4 bar) m) Maximum backwash transtnembrance Pressure :- 20 usig (1.4 bar) n) Instantaneous Chlorine Tolerance :- 100 ppm o) Instantaneous Hydrogen Peroxide Tolerance :- 200 ppm** p) maximum chlorine Expossure :-200.000ppm-hrs q) maximum instantaneous Feed Turbidity :- 100 NTU r) Maximum Operating Temperature:- 104° F s) pH operatin range:- 4.0-10.0 t) Clraning pH Range- 1.5-13.0 u) Operating Mode:- Inside to Outside Filtration Direct flow of Crossflow.
v) Backwash flux-100-150 gfd (170-255 l/m²/hr) w) Backwash Duration -30-60 seconds. x) Backwash Frequency-20-60 minutes. y) Chemical Enhanced Backwash Frequrncy-0-4 ties per day z) Chemical Enhanced Backwash Duration-1-30 minutes z1) Disinfection Chemicals -Na0CL, H₂o₂, CLO₂, or , NH₂CL z2) Cleani9ng Chemicals -NaOH, HCL, H₂SO₄, or Citric Acid (Make- Suez/Dow/Toray)
Installation and Commissioning of UF unit for removing all undissolved impurities including suspended solids, colidall impurities having Feed Prussure-5 Bar. . (Supplied by Departmentally)
Supply and delivery of Skid mounted Ozonator of capacity 6 gm/hr.
Supply, delivery & Installationof 500 lit capacity PVC Tank (Rectrangular Shape, White Color) for storage of Water of different stages.
Making new internal wiring and fettling illumination arrangement inside the MTU unit as per requirement and making distribution of electric line from DG set to PDB inside of MTU for reorientation of pouch packing machine including servicing of electrical panel as per direction of EIC
Servicing of 25 KVA Diesel Generator set due to including replacing of mobile filter and diesel filter etc.
Deployment of daily service charges of the service engineer with all conveyance fooding and accommodation for the Restoration of the breakdown of Mobile Treatment Unit - Balurghat
Add: 18% GST
Add: 1% CESS
ALOK ENTERPRISE. A Unit of Saket Trexim Pvt. Ltd. (BID ID -6996865)
ORIENTAL ENGINEERING CO. (BID ID -7044576)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.68 MB
Tendernotice_2.pdf
PDF • 0.51 MB
BOQ_2096571.xls
BOQ • 0.24 MB
Download all tender documents and submit your bid