Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.1 LAccepted-AOC | ₹24.1 L | L1 | Accepted-AOC Accepted. Being the L1 bidder. |
| 2 | L2₹24.4 LRejected-AOC NOT AVAILABLE | ₹24.4 L | L2 | Rejected-AOC Rejected as not being the lowest bidder. |
| Sl No | Description | Qty | Unit | AMBICA ENGINEERING L1 | SHREE JAGDISH FURNITURE CO. L2 |
|---|---|---|---|---|---|
| 1.00 | M & L Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out In Hard/dense soil. Completed all as specified and directed by Engineer-in-charge. | 100 | Sqm | 225 ₹22,500 | 88 ₹8,800 |
| 2.00 | Excavating in trenches, by mechanical means(hydraulic excavator) n exc 1.5 m wide and n exc 1.5 m in depth; for footing, Plinth Beam & Dwarf Wall, etc. n exc 10 sq m on plan and getting out in any type of soil. Completed all as specified and directed by Engineer-in-charge. | 40 | Cum | 250 ₹10,000 | 247 ₹9,880 |
| 3.00 | M & L for Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface. Completed all as specified and directed by Engineer-in-charge. | 85 | Sqm | 200 ₹17,000 | 55 ₹4,675 |
| 4.00 | M & L for Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured). Completed all as specified and directed by Engineer-in-charge. | 35 | Sqm | 200 ₹7,000 | 75 ₹2,625 |
| 5.00 | M & L Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall. Completed all as specified and directed by Engineer-in-charge. | 40 | Rm | 200 ₹8,000 | 47 ₹1,880 |
| 6.00 | M & L Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area. Completed all as specified and directed by Engineer-in-charge. | 30 | Sqm | 200 ₹6,000 | 58 ₹1,740 |
| 7.00 | M & L Cement concrete in foundations, filling and mass concrete 1:4:8 (Type D2) using 40 mm graded aggregate. Completed all as specified and directed by Engineer-in-charge. | 6 | Cum | 4,500 ₹27,000 | 3,700 ₹22,200 |
| 8.00 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in any type of soil/rock. Completed all as specified and directed by Engineer-in-charge. | 20 | Cum | 750 ₹15,000 | 125 ₹2,500 |
| 9.00 | Removing excavated material in any type of Soil/rock n exc. 500m and depositing where directed at a level n exc. 1.5 m above the starting point. Completed all as specified and directed by Engineer-in-charge. | 40 | Cum | 900 ₹36,000 | 555 ₹22,200 |
| 10.00 | M & L RCC- M-30 (Design Mix) using 20mm graded aggregate for footing and plinth beams. Completed all as specified and directed by Engineer-in-charge. | 7 | Cum | 8,800 ₹61,600 | 7,547 ₹52,829 |
Updated dates
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
13 Nov 2025, 6:00 pmClosed
GE (NW) BHANDUP
GE (NW) BHANDUP, MUMBAI
CONSTRUCTION OF LAB UNDER PM SHRI SCHEME IN PM SHRI KENDRIYA VIDYALAYA BHANDUP, MUMBAI UNDER GE (NW) BHANDUP
2025_MES_734851_1
8445/B
Open Tender
Civil Works
180 days
PM SHRI KENDRIYA VIDYALAYA BHANDUP, MUMBAI
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (NW) BHANDUP
₹50,000
Yes
19 Jun 2026
11 Oct 2025
15 Nov 2025
11 Oct 2025
13 Nov 2025
25 Oct 2025
11 Oct 2025 - 21 Oct 2025
Amount
M & L Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out In Hard/dense soil. Completed all as specified and directed by Engineer-in-charge.
Excavating in trenches, by mechanical means(hydraulic excavator) n exc 1.5 m wide and n exc 1.5 m in depth; for footing, Plinth Beam & Dwarf Wall, etc. n exc 10 sq m on plan and getting out in any type of soil. Completed all as specified and directed by Engineer-in-charge.
M & L for Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface. Completed all as specified and directed by Engineer-in-charge.
M & L for Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured). Completed all as specified and directed by Engineer-in-charge.
M & L Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall. Completed all as specified and directed by Engineer-in-charge.
M & L Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area. Completed all as specified and directed by Engineer-in-charge.
M & L Cement concrete in foundations, filling and mass concrete 1:4:8 (Type D2) using 40 mm graded aggregate. Completed all as specified and directed by Engineer-in-charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in any type of soil/rock. Completed all as specified and directed by Engineer-in-charge.
Removing excavated material in any type of Soil/rock n exc. 500m and depositing where directed at a level n exc. 1.5 m above the starting point. Completed all as specified and directed by Engineer-in-charge.
M & L RCC- M-30 (Design Mix) using 20mm graded aggregate for footing and plinth beams. Completed all as specified and directed by Engineer-in-charge.
M & L RCC- M30 (Design Mix) using 20mm graded aggregate for RCC Column complete all as specified and directed. Completed all as specified and directed by Engineer-in-charge.
M & L RCC- M30 (Design Mix) using 20mm graded aggregate for beams and lintels complete all as specified and directed. Completed all as specified and directed by Engineer-in-charge.
M & L RCC- M30 (Design Mix) using 20mm graded aggregate for RCC Slab. Completed all as specified and directed by Engineer-in-charge.
M & L RCC- M30 (Design Mix) using 20mm graded aggregate for RCC parapet wall/drops/RCC Chajjas. Completed all as specified and directed by Engineer-in-charge.
S & F TMT bars 10mm dia & over of Grade Fe 500 incl cutting, bending, binding & placing in position with binding wirefor footings Slab beams roof slab etc Completed all as specified and directed by Engineer-in-charge.
All as per item No 15 but 5 to 10mm dia in stirrups, spacers & binders. Completed all as specified and directed by Engineer-in-charge.
M & L Form work for rough finished surfaces of concrete measured flat for For Footing. Completed all as specified and directed by Engineer-in-charge.
M & L Form work for rough finished surfaces of concrete measured flat for Column. Completed all as specified and directed by Engineer-in-charge.
M & L use & waste Form work for rough finished surfaces of concrete measured flat for Plinth Beam. Completed all as specified and directed by Engineer-in-charge.
M & L use & waste Form work for rough finished surfaces of concrete measured flat for RCC beams sides and soffits. Completed all as specified and directed by Engineer-in-charge.
M & L use & waste Form work for rough finished surfaces of concrete measured flat for RCC Slab. Completed all as specified and directed by Engineer-in-charge.
M & L use & waste Form work for rough finished surfaces of concrete measured flat for RCC drops/Chajjas. Completed all as specified and directed by Engineer-in-charge.
M & L Pre-cast cement concrete Type C1 1:3:6 (20mm graded aggregate) block masonry with solid blocks, exc 10 cm in width and setting in cement mortar 1:6, Complete all as specified and as directed by Engineer-in-charge.
S& F factory made WPC solid door frames of size 65x125mm including fixing to walls using three numbers dash through bolt on each side Completed all as specified and directed by Engineer-in-charge.
S& F factory made single extruded WPC solid door shutters decorative type flush door of size 30mm Completed all as specified and directed by Engineer-in-charge.
S& F factory made single extruded WPC jali door shutters decorative type door of size 30mm Completed all as specified and directed by Engineer-in-charge.
S&F extruded aluminum alloy handles (150mm ) fabricated type anodised Completed all as specified and directed by Engineer-in-charge.
S&F hinges (150 mm) stainless steel medium weight Completed all as specified and directed by Engineer-in-charge.
S&F aluminum anodised barrel tower bolts (150 mm ) of extruded section Completed all as specified and directed by Engineer-in-charge.
S&F 300 mm Aluminium alloy , anodised , sliding door bolt with hasp, staple (bolt type ) and fixing clips of sheet , cast , exctruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed Completed all as specified and directed by Engineer-in-charge.
M&L for Ready mix plaster 10mm thick on internal faces of bricks or concrete surface including including preparation of wall surfaces etc Completed all as specified and directed by Engineer-in-charge.
M&L for rendering 5mm thick in ready mix plaster on ceiling surface and finishing the surfaces even and smooth without using extra cement including scrapping down and preparation of ceiling surfaces to receive plaster, scaffolding as reqd etc, Completed all as specified and directed by Engineer-in-charge.
M&L for Ready mix polimer modified cement based plaster 20mm thick on new external bricks or concrete surface including preparation of wall surfaces etc Completed all as specified and directed by Engineer-in-charge.
M & L for preparation of new surfaces of wall and thereafter applying two coats of plastic emulsion painting with roller over a coat of Primer and 3mm thick wall care putty Completed all as specified and directed by Engineer-in-charge.
Material & Labour for applying two Coats Of Oil Bound Distemper Over One Coat Of Primer on ceiling incl 3mm thick wall care putty. Completed all as specified and directed by Engineer-in-charge.
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additivesM @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. Completed all as specified and directed by Engineer-in-charge. (Note : Warranty should be for 05 years).
M & L Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface. Completed all as specified and directed by Engineer-in-charge.
M & L 75 mm thick Cement concrete type D-2 1:4:8 (40mm graded aggregate) as in Sub-Floors, Sub-Bases, Floors and pavings, etc Complete all as specified and as directed by Engineer-in-charge.
M&L Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete incl Screed bed 20 mm thick in cm 1:6 for laying floor finishes Completed all as specified and directed by Engineer-in-charge.
M&L Machine cut kota stone slab flooring 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete incl Screed bed 20 mm thick in cm 1:6 for laying floor finishes Completed all as specified and directed by Engineer-in-charge.
M&L for glazed ceramic coloured tiles 450x300mmx7mm thick in vertical surfaces such as skirting/dado and risers to steps and including over 10mm thick rendering in CM 1:4 on fair faces of brick/concrete surfaces as in backing coat for tiles. etc, Completed all as specified and directed by Engineer-in-charge.
M & L for granite work(table rubbed and polished) in jambs, steps, window cills, platforms and like in cement mortar 1:4 including pointing in white cemnt using marble dust with admixture of pigment to match with shade of granite 20mm thick, all as specified and directed complete
M & L 75mm thick Plinth Protection PCC (1:3:6) Type C1 using 20mm graded aggregate. Completed all as specified and directed by Engineer-in-charge.
M&L for application of 7 layer of waterproofing system on leaking roof by thorough surface preparation, opening and filling of cracks, application of absorption coat of Thermacool WP51, application of sandwich coat of elastomeric (Thermacool WP51 + Cement) waterproofing layer with 80 gsm non woven fibre mesh, application of 3 rd coat of elastomeric (Thermacool WP51 + Cement) waterproofing layer and topcoated with two coats of Thermacool 0.3c elastomeric, waterproofing solar IR heat reflective coating having a min. Service life of 10 years Completed all as specified and directed by Engineer-in-charge.
M&L for screed bed or bedding layer of mortar CM(1:3) 10 mm thick using water proofing compound. Completed all as specified and directed by Engineer-in-charge. Note: WPC will be paid separately.
Supply only Water Proofing compound. Completed all as specified and directed by Engineer-in-charge.
S & F powder coated aluminium sections frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc.Completed all as specified and directed by Engineer-in-charge.
S&F aluminum anodised grill DG- 202 ( 10 mm x 5.2mm ) of Deco grill or equivalent fixed with 'F' section min weight not less than 3.6 kg/sqm of approved make. Completed all as specified and directed by Engineer-in-charge. Note:- (i) Make shall be of M/s Decogrille of M/s Associated Groups or equivalent as approved by the GE. (ii) Minimum thickness of anodizing shall be 15 microns.
Supply only 5.5 mm thick glass ordinary quality in plain exc 0.50 Sqm each pane including rubber beading or gasket for aluminium section Completed all as specified and directed by Engineer-in-charge.
Supply only of stainless steel wire cloth of 0.36 mm nominal dia of wire and average width of aperture 1.40 mm , fixed in aluminium windows Completed all as specified and directed by Engineer-in-charge.
S&F in Godrej night latch 4 lever for entrance door with fittings Completed all as specified and directed by Engineer-in-charge.
S&F in repair brass chromium plated towel rail 20mm dia 'D' type 600mm long between flanges, Cat No BA -01 of with and including chromium plated brass screws etc Completed all as specified and directed by Engineer-in-charge. Make:Prayag polymers Pvt Ltd or equivalent
S&F in repair for 20mm dia fancy type chromium plated curtain rods with fixing fancy brackets, brass screws etc Completed all as specified and directed by Engineer-in-charge.
S&F CI floor trap 100mm dia outlet, with CP grating including jointing to waste pipe, fixed in cement concrete type B1 (1:2:4) Completed all as specified and directed by Engineer-in-charge.
S&F wash hand basin, vitreous china white of size 550x 400mm excluding taps, waste chain and plug and porcelain stopper but including brackets,32mm waste fitting, brass, chromium plated for glazed ware wash basin and CP 15mm dia pillar taps with swan neck chromium plated fancy type etc complete all as specified and directed.
S&F CP angle cock 15mm bore fancy type chromium plated.with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed Completed all as specified and directed by Engineer-in-charge.
S&F Brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed Completed all as specified and directed by Engineer-in-charge.
S/Fin repair 15mm size PVC connection with PTMT nuts 450mm length. Completed all as specified and directed by Engineer-in-charge.
S&F low density polyethene pipes (LDPE) 32mm of pressure rating 6 Kg/cm2 fixed to walls or laid in floors etc. Completed all as specified and directed by Engineer-in-charge.
S&F SS soap dish of Prayag polymers Pvt Ltd or equivalent Completed all as specified and directed by Engineer-in-charge.
S&F 15mm bore U- PVC pipes of pressure rating 10 kgf/cm2 fixed concealed to wall, ceiling or floors etc. with all fittings Completed all as specified and directed by Engineer-in-charge.
All as per item No 61 but 20 mm bore. Completed all as specified and directed by Engineer-in-charge.
Supplying and fixing in repair rotational moulded polythylene water storage tanks, double layered (ISI marked) of 1000 litres capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I, including provision of necessary fittings for connecting the overflow, drain out, inlet and outlet pipes, complete all as specified and as directed.
S&F in repair 20mm bore UPVC gate valves with butterfly head for controll, Completed all as specified and directed by Engineer-in-charge.
S&F PVC(SWR) pipes single socketed in any length with rubber ring joints fixed to walls 110mm dia Completed all as specified and directed by Engineer-in-charge.
M&L synthetic Writing board with green or white colour surface fixed to walls including raised wooden boarders all as specified of size 4mx1.80m
Consultancy: (a) Consultancy to be carried out by E-in-C approved consultant including preparation of architectural and structural design and dgrs with specifying strata for construction of Lab having size 7.00mtr x 10.60 mtr incl passage area 2.10mtr wide. (b) Preparation of detailed estimate as per given drgs based on SSR 2020. (c) Para (a) & (b) to be vetted by IIT/ NIT/ any AICTE approved Govt Engineering College. (d) Submission of 3 Nos of hard copies incl soft copy in CD. Note : Rate for identifying strata to be included in this item only. No extra payment will be given. Also charges for site visit during execution, if required will also be included in this item without any extra cost to Govt.
Material and Labour for point wiring using approved colour coding as per IS ,with multistranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit with all fittings, accessories, PVC junction boxes etc.with and including concealed PVC switch, socket, regulator mounting, SAC-WHT-JBX1, 86 Size, ( HSN 85365020) junction box Make Jaquar or equivalent and also including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH cable as earth continuity conductor along with wiring and connecting to earth dolly Completed all as specified and directed by Engineer-in-charge. for the following:- (a) One light point/ exhaust fan point controlled by one, one way switch 6 Amps.
(b) All as per description of item No 68 but Two light point controlled by one, one way switch 6 Amps on the same switch circuit Completed all as specified and directed by Engineer-in-charge.
(c) All as per description of item No 68 but One 5 pin socket outlet plug point, 16 Amps, controlled by one, switch on same board Completed all as specified and directed by Engineer-in-charge.
(d) All as per description of item No 68 but One two way light point controlled by two nos. two way 6A switches Completed all as specified and directed by Engineer-in-charge.
(e) All as per description of item No 68 but One bell point controlled by one, one way switch 6 Amps Completed all as specified and directed by Engineer-in-charge.
(f) All as per description of item No 68 but One ceiling fan point & regulator controlled by one, one way switch 6 Amps Completed all as specified and directed by Engineer-in-charge.
Description all as per Item No 68 here-in before but using 2.5 Sqmm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 Volts grade for one 6 pin socket outlet plug point, 6 Amps independent including necessary running of 2.5 Sqmm PVC insulated multistranded copper conductor single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly all as specified and as directed. Note for Item 68 & 74:- Cutting chases for conduits and sinking's for PVC switch boxes and making good to walls in cement mortar 1:3 to match with existing surfaces shall be carried out by the contractor without any extra cost from the department.
Supply and fixing High strength, flame retardant, fade-resistant Poly Carbonate, Easy on-off, White 16AX Three gang one way switch and face plate in one complete with Terminal screw in ready for wiring. Completed all as specified and directed by Engineer-in-charge. Make Jaquar Cat No SWG-WHT-PC16A3G01 or Equivalent as approved by GE.
Supply and fixing High strength, flame retardant, fade-resistant Poly Carbonate, Easy on-off, White 16AX Two gang two way switch and face plate in one complete with Terminal screw in ready for wiring. Completed all as specified and directed by Engineer-in-charge. Make Jaquar Cat No SWG-WHT-PC16A2G02 or Equivalent as approved by GE.
Supply and fixing High strength, flame retardant, fade-resistant Poly Carbonate, Easy on-off, White 16A Door bell one way switch and face plate in one complete with Terminal screw in ready for wiring Completed all as specified and directed by Engineer-in-charge. Make Jaquar Cat No SWG-WHT-PC16A1GB1 or Equivalent as approved by GE.
Supply and fixing High strength, flame retardant, fade-resistant Poly Carbonate, Easy on-off, White 1 Gang 16A switched socket with indicator and face plate in one complete with Terminal screw in ready for wiring. Make Jaquar Cat No SKG-WHT-PC16ASC1GS1 or Equivalent as approved by GE.
Supply and fixing High strength, flame retardant, fade-resistant Poly Carbonate, Easy on-off, White 1 Gang Fan speed controller switch in one complete with Terminal screw in ready for wiring Completed all as specified and directed by Engineer-in-charge. Make Jaquar Cat No- SWG-WHT-PC1ARFSS or Equivalent as approved by GE.
M & L Ceiling rose, 3 terminal /PVC/ polycarbonate, isolated body Completed all as specified and directed by Engineer-in-charge.
Supply and fixing electric Buzzer, Ding Dong bell suitable for operation on AC. 230 volts, single pole Completed all as specified and directed by Engineer-in-charge.
Supply and fixing wall/ surface mounted, LED- 35W ± 10% watt Power consumption, AL. Extruded Housing, 230 VAC, 50Hz batten fitting complete with standard warranty of manufacturer from date of purchase/ installation Completed all as specified and directed by Engineer-in-charge. Make Jaquar Cat No- HBT-WHT-LKBU4KVS35XC or equivalent in Philips, Crompton.
Supply and fixing energy saving, Full Glow LED Surface Light luminaire complete with Motion Sensor, Power consumption 15 Watt, Round Shape, single Phase 230 Volt. fitting and standard warranty of manufacturer from date of purchase/ installation all as specified and directed. Make Philips ( Product SKU : 929003671501) or equivalent in Jaquar, Crompton.
Supply and fix for energy saving new generation environmental friendly long life versatile pressure die aluminium IP-66 for security light fitting luminaire of capacity 30 watt with high power LEDs as light source and electronic driver , necessary mounting arrangements and provision of 1.0 Sqmm 3 core copper conductor cable multistranded from ceiling rose to light fitting including 1.5 metres long GI pipe medium grade bracket of suitable size & shape to light fitting mounting dia, secured and fixed with clamps made out of MS flat iron of size 25mm x 5mm, nuts, bolts etc , as approved, Completed all as specified and directed by Engineer-in-charge. Make- Jaquar Cat No LPCRSRT30WXW or equivalent in Philips, Havells.
Supply and fixing ceiling fans working on single phase input voltage 140-285 , Sweep- 1200 mm, Power 32 W, 345 RPM , with 232 Air delivery CMM (m3 /min), complete with compact BLDC Motor, blades, down rods, electronic regulator and accessories, including making connections with provision of flexible wire 23 /0.0076 twin core copper conductor from ceiling rose/connector to fan in Philips, Havells Make- Atomberg (Renesa Alpha) or Equivalent in Havells Model -Trinity
M & L for submain wiring with approved colour coding as per IS with two single core PVC insulated FRLS multistranded copper conductor cable of size 4 Sqmm nominal area and drawing into concealed PVC non metallic rigid heavy duty conduit and its accessories (ISI marked) of suitable size including PVC insulated multistranded copper conductor 4 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly complete all as specified and as directed. Note- Three run of 4 Sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed
Supply and fixing 25 A Heavy Duty MCB COMBO WITH 4M (Metal) Power box, with 6 A/16 A Heavy Duty Socket with Shutter and one single pole 25 A SP C MINI MCB including white cover plate complete all as specified and as directed
S & F sheet metal enclosure suitable for Flush Mounting and Surface Mounting, MCB DB with 250 Amps rated bus bar for each phase, Fully insulated & shrouded 2 Neutral bars, 2 Earthbar and Cable ties for Cable management, & With provision for DPX³ 250 MCCB as incomer and SP/TP MCB's as outgoing, 415 Volts, IP 43 - #IK 09 with metal double door & magnetic locking system including inserting the DBs in wall by cutting the brick/ stone masonary etc and making good of disturbed surface in cement mortar to match the existing surface & colour to wall in Philips, Havells (a) VTPN 4 Way. (Make Legrand Cat No - 5077 58 orequivalent.)
Supply and fixing DPX³ 160 MCCB with O/L & S/C thermal magnetic protection unit, 25 KA breaking Capacity, 4 Pole , 63 Amps, in Philips, Havells. Make Legrand Cat No 4200 53 or Equivalent in L&T
Supply and fixing amp rating 240V, 10KA 'C' curve, IP 20 protected terminals, miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning:- (a) SP 5 To 32 AMP
M & L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick, buried vertically in ground (Earth pit not less than 2.25 metres deep below normal ground level and top edge of the plate not less than 1.5 m below ground level), connected to and including galvnised steel earthing lead wire 4 mm dia, by means of bolts, nuts, check nuts and washers etc; GI pipe 15 mm dia medium grade pipe for protection of G.I earth lead wire, both to be provided to the extent of 7.5 metres, all as shown on electrical plate No 3 of MES SSR-2009 Part-I, other end connected to electrical main switch board (inside the bldg) GI protection pipe buried in ground, laid under floors/plinths or fixed on walls or concealed in walls etc; with provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate , including PCC 1: 2 : 4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with G.I 20 mm dia medium grade pipe and M.S funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of strata & testing on completion Complete all as specified and as directed by Engineer-in-charge.
Surface excavation n.exc. 30 cm deep and averaging 15 deep and getting out in soft loose soil. Complete all as specified and as directed by Engineer-in-charge.
M & L Rendering 15 mm thick on fair faces of brick work or concrete surfaces using CM 1:4, finished the surface even and smooth Complete all as specified and as directed by Engineer-in-charge.
M & L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade mixed with greay cement and pigment. Complete all as specified and as directed by Engineer-in-charge.
M & L for sand filling under floors or in foundations incl watering and consolidation Complete all as specified and as directed by Engineer-in-charge.
M & L Reinforced concrete pipe class NP 2 laid and jointed complete with collars of 200 dia bore. Complete all as specified and as directed by Engineer-in-charge.
M & L concrete bed to drain pipe of 200 dia bore using type C2 (1:3:6). Complete all as specified and as directed by Engineer-in-charge.
Excavation in Trenches not exc 1.50 Metre wide and not exc 1.50 Metre depth for laying of UG Cable etc and getting out in Soft/Loose Soil, Complete all as specified and as directed by Engineer-in-charge.
Removing Surplus excavated Soil to a distance not exc 50.00 Metre away and depositing where directed at a level not exc 1.50 Metre above the Starting Point, complete all as specified and as directed.
Supply and fixing Unplasticised PVC (UPVC) pipes of pressure rating 10 kgf / cm2 with all fitting and fixed complete to walls with clips, wall hooks, wooden plugs, and ceilings or laid in floors Complete all as specified and as directed by Engineer-in-charge for bore of pipe:- (a) Bore of pipe 25 mm
Supply and fixing Unplasticised PVC (UPVC) pipes of pressure rating 10 kgf / cm2 with all fittings and fixed complete, together with Pipe, laid in trenches complete all as specified and as directed bore of pipe:- (a) Bore of pipe 32 mm
(b) All as per item No 101 but Bore of pipe 40 mm. Complete all as specified and as directed by Engineer-in-charge.
S & F UPVC Ball valve 25 mm Outer dia heavy weight as per pre requirement of the site with handle screwed both ends for UPVC Pipes or for unions Complete all as specified and as directed by Engineer-in-charge.
S & F UPVC Ball valve 40 mm Outer dia heavy weight as per pre requirement of the site with handle screwed both ends for UPVC Pipes or for unions Complete all as specified and as directed by Engineer-in-charge.
Cutting existing steel tubing for alterations or additions (Each cut measured) for Bore of Pipe 40mm or 50mm without taking down Complete all as specified and as directed by Engineer-in-charge.
Screwing existing steel tubing for alterations or additions (or lengthening screw on pipe to form connector) for Bore of Pipe 40mm or 50mm without taking down Complete all as specified and as directed by Engineer-in-charge.
Material and labour for cable route marker made of Pre-cast cement concrete block masonry Type C1 1:3:6 (20mm graded aggregrate) with solid blocks, exc. 10 cm in width and setting in cement concrete mortar 1:6, including embosing DANGER/ LT CABLE / MES on cable route marker and properly painting with approved colour, size of cable route marker 900x300x100mm complete buried in ground for a depth of 45 cm & necessary earth work Complete all as specified and as directed by Engineer-in-charge.
Supply and laying HDPE Pipe PN 10 Size 40 mm laid in trenches along with accessories such as coupler for electrical applications as in cable protection pipe from physical damage Complete all as specified and as directed by Engineer-in-charge.
Supply and laying across road crossing reinforced concrete pipes, class NP2, laid and jointed complete with collars of size 150 mm Complete all as specified and as directed by Engineer-in-charge.
Material and Labour Soling (or sub base) 150 mm spread thickness with broken boulders or quarried stone, inter stices filled, surface formed and rolled and consolidated to required gradient and camber Complete all as specified and as directed by Engineer-in-charge.
M&L Cement Concrete Type B2-1:2:4 (40mm graded aggregate) as in Foundation filling and mass concrete for grounting of panel and making good disturbed road surfaces including necessary Formwork (as/if required) Complete all as specified and as directed by Engineer-in-charge.
Supply & laying LT Aluminium Conductor Power Cables, Stranded Conductor, XLPE Insulated, Cores Laid Up, PVC Innersheathed, Armoured galvanised steel strip, Extruded PVC Type ST2 Outer Sheathed, 1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments. cross-sectional area 25 Sqmm 4 Core, passing in HDPE Pipe laid in trenches/ fixing on surface of Wall in cable tray securing with GI Cable clamps including Brass Cable Glands at termination end points Mild Steel Flat Iron Clamps of adequate size, etc. and Testing complete all as specified and as directed.
Supply and fixing DPX³ 160 MCCB with O/L & S/C thermal magnetic protection unit, 25 KA breaking Capacity, 4 Pole , 63 Amps, Complete all as specified and as directed by Engineer-in-charge. Make Legrand Cat No 4200 53 or Equivalent.
SHREE JAGDISH FURNITURE CO. (BID ID -3464637)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.34 MB
TENDERDOCUMENTS.pdf
Tender Documents • 1.45 MB
BOQ_822852.xls
BOQ • 1.07 MB
Download all tender documents and submit your bid