| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.5 LAccepted-AOC | L1 | Accepted-AOC Being L1 bidder. | |
| 2 | L2₹25.9 L+₹2.4 L (10.2%)Rejected-Finance 44B CIRCULAR GARDEN REACH ROAD KOLKATA 700 023 | KOLKATA | WEST BENGAL | 700023 | L2 | Rejected-Finance Rejected due to higher than L1 bidder. Amount considered after deduction of schedule of credit amount i.e Rs. 111595.00 | |
| 3 | L3₹26.5 L+₹2.9 L (12.5%)Rejected-Finance GC ROAD ABDUL LATIF ROAD PO TITAGARH KOLKATA 700119 | 24 PARAGANAS NORTH | WEST BENGAL | 700119 | L3 | Rejected-Finance Rejected due to higher than L1 bidder. Amount considered after deduction of schedule of credit amount i.e Rs. 111595.00 | |
| 4 | L4₹26.6 L+₹3.1 L (13.1%)Rejected-Finance | L4 | Rejected-Finance Rejected due to higher than L1 bidder. Amount considered after deduction of schedule of credit amount i.e Rs. 111595.00 | |
| 5 | L5₹26.8 L+₹3.2 L (13.8%)Rejected-Finance 117 LENIN SARANI KOLKATA 700 013 WEST BENGAL | KOLKATA | KOLKATA | WEST BENGAL | 700013 | L5 | Rejected-Finance Rejected due to higher than L1 bidder. Amount considered after deduction of schedule of credit amount i.e Rs. 111595.00 |
Tender Value
₹25.0 L
EMD Value
₹49,960
Closing Date
4 Jun 2021, 6:00 pmClosed
GE CENTRAL, KOLKATA
GE Central Kolkata, T-37, Napier Road, Hastings, Kolkata-7000022
REPAIR/ REPLACEMENT OF EXTERNAL ELECTRIC SUPPLY INCLUDING REPAIR TO FEEDER PILLAR BOX, LT PANELS, CABLES, JUNCTION BOXES AND STREET LIGHT AT BM CAMP INCLUDING AF CAMP AT BMC UNDER GE (CENTRAL) KOLKATA
2020_MES_396870_4
8323
Open Tender
Miscellaneous Works
Item Rate
270 days
Kolkata
As per tender documents
10 documents required · 10 mandatory
₹500
Yes
GE CENTRAL KOLKATA
₹49,960
Yes
22 Jul 2021
15 May 2021
5 Jun 2021
15 May 2021
4 Jun 2021
23 May 2021
15 May 2021 - 22 May 2021
Amount
Excavation in trenches not exc. 1.5 metre wide and not exc. 1.5 metre in depth and getting out as in soft/loose soil for foundation of pole, laying of electric cables etc complete all as directed by the Engr-in-Charge.
All as per Item No.1 above here in before but for each additional 1.5m or part thereof in depth beyond the first 1.5 m complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 Cm thick complete all as specified in soft/loose soil and as directed by Engineer-in-Charge.
Removing excavated materials of soil not exc. 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed by Engineer-in-Charge.
Materials and Labour Cutting existing road / path etc for taking out cable and proction pipe and making good the disturbed surfaces with cement concrete type C2 ( 1:3:6, using 40mm graded crushed stone aggregates) of suitable depth complete all as directed by Engineer-in-Charge.
Supply and laying dry coarse sand as in cushioning of under ground electric cable in trenches, laid to a uniform thickness of 23 Cm (15 Cm under the cable & 8 Cm over the cable) and gently punned down to 18 Cm thickness complete all as specified and as directed by the Engr-in-Charge. Note:- Thickness after punning down shall be measured for payment.
Supply and laying in trenches Bricks, sub class 'B' over burnt (kiln burnt) old size bricks, laid flat dry with width of the bricks laid to the axis of the cable for protection of cable complete all as specified and as directed by the Engr-in-Charge.
Laying only in trenches Old serviceable bricks obtained from taking out old unserviceable XLPE cable, laid flat dry with width of the bricks laid to the axis of the cable for protection of cable complete all as specified and as directed by the Engr-in-Charge.
Material and labour for PCC (1:3:6) type C-2 using 40mm graded stone aggregate with and including all necessary form work complete all as specified & directed including demolition of old PCC/broken PCC
Material and labour for PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in coping of pole/struts and other similar location etc with and including all necessary form work complete all as specified & directed including demolition of old PCC/broken PCC.
Taking out unserviceable UG cables of any type and any sizes from trenches etc and removing from the site of work complete all as specified and directed. Note:- (i) Serviceable bricks obtained shall be stacked properly for re-use. (ii) Excavation and earth work shall be measured and paid separately under relevant item of these schedule.
Supply and laying XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 185 Sqmm 3.5 core in trenches/ duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as directed by the Engr-in-Charge.
Supply and laying XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 120 Sqmm 3.5 core in trenches/ duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as directed by the Engr-in-Charge.
Supply and laying XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 95 Sqmm 3.5 core in trenches/ duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as directed by the Engr-in-Charge.
Supply and laying XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 70 Sqmm 3.5 core in trenches/ duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as directed by the Engr-in-Charge.
Supply and laying XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 50 Sqmm 3.5 core in trenches/ duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as directed by the Engr-in-Charge.
Supply and laying XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 35 Sqmm 3.5 core in trenches/ duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as directed by the Engr-in-Charge.
Supply and laying XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 25 Sqmm 4 core in trenches/ duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as directed by the Engr-in-Charge.
Supply and laying XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 16 Sqmm 2 core in trenches/ duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as directed by the Engr-in-Charge.
Supply and laying XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 10 Sqmm 2 core in trenches/ duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as directed by the Engr-in-Charge.
Supply and fix Timer switch of analogue type for street light fittings, module 1 including taking down old unserviceable one complete all as specified and as directed. Make:- L&T / Schneider / ABB / SIEMENS/ Legrand/C&S.
Supply and Fix Modular Contactor, 40A-2NO, 3 module taking down old unserviceable one complete all as specified and as directed. Make:- L&T / Schneider / ABB / SIEMENS/ Legrand.
Supply and Fix Modular Contactor, 40A-4NO, 3 module taking down old unserviceable one complete all as specified and as directed. Make:- L&T / Schneider / ABB / SIEMENS/Legrand.
Suplly and fix PVC insulated, stranded copper electric cable, 2.5 Sqmm 2 core drawn into the steel tubular pole by drilling holes above the junction box and another holes near street light bracket including taking out old unserviceable copper wire complete all as specified and as directed.
Supply and fix Thermoplastic, polycarbonate pole junction box of size 240mmx 120mmx 95mm along with MCB 6 Amps and fixed to pole with MS clamp made out of MS flat of section 25x 3mm including all necessary fittings and connection including taking down old unserviceable one complete all as directed by Enginner-in-Charge. Make:- Sintex Cat Part No.GSJB 2817 or equivalent model from make:- Hansel.
Supply and fix Thermoplastic, polycarbonate pole junction box of size 103mmx 103mmx 73mm and fixed to pole with MS clamp made out of MS flat of section 25x 3mm including all necessary fittings and connection including taking down old unserviceable one complete all as directed by Enginner-in-Charge. Make:-Sintex cat Part No.GSMB 1111 or equivalent model from make:- Hansel.
Supply and fixing of junction pole box made of high quality thermoplastic polycarbonate (shock proof ,rust free,corrosion free,acid and chemical resistant,fire retardant, having high impact strength, of IK 9, made of halogen and silica free recyclable material IP66/67 degree of protection UV resistant, having high graded internally embedded gasket made of poly urethane should withstand glow wire test at 960 c centigrade should be flame retradant and self extingushing with switch gear assemblies as per IEC-439-1 the junction box should have 4 power terminal of 25 Sqmm and earth terminal along with SP MCB of 6 Amp fitted in it the dimension of box shall be 250x200x105 in mm (LxHxD) . and fixing to tubular /PCC pole using MS flat of size 25x3mm with suitable nuts and bolds after taking down old unserviceable one. Make:- Sintex Cat Part No.GSMB 2520 or equivalent model of make:- Hansel.
Supply and fix Asthetically designed decorative hot dipped galvanised mild steel pole for street light / security light with grey powder coated finish complete including taking down old unserviceable street light pole, as directed by Engineer-in-charge. Make:-Havells cat part No. 6MPE or equivalent model of make:-Crompton/ Bajaj/Surya
Supply, installation, testing and commissioning of feeder pillar box CPRI approved of size 1.5m x 1.2m x0.60m, outdoor type, totally enclosed, dust and vermin proof, factory made, confirming to IP-54, double door both front and back side, with locking arrangement, prewired, made out of 3mm thick CRCA sheet with 04 Noslegs, MS angle of size 40x40x6mm of size 0.60m long suitably grouted with PCC type C2 ( 1:3:6, using 40mm graded crushed stone aggregates) and 15mm thick cement plaster in CM 1:4 over concrete surfaces including two coats of synthetic enamel paint of approved colour over a coat of red oxide primer on stell surfaces both internally and externally with aluminium bus bar 600 Amps rated duly colour coated 04 Nos and connection through aluminium busbar of appropriate size to MCCBs and MCBs and power contactor and accessories fitted in it for incoming and outgoing cable, including LED multi function meter and necessary cable, lugs and glands with following accessories including taking down old unservicaeble feeder pillar box complete all as directed by Engineer-in-Charge. Note:- Cost of spare parts as mentioned below shall deemed to be included in the rate quoted by the tenderer against these item. (a) MCCB, 400Amps, 4 Pole, 415 Volts, 36 kA with thermal and magnetic release. -01 No ( Incoming). (b) MCCB, 100Amps, 4 Pole, 415 Volts, 25 kA with thermal and magnetic release. -04 No ( outgoing). (c) MCB, 10kA, B series, 32 Amps, 415 Volts, Four pole. -02 Nos. (d) LED Multifunction meter with CT of required capacity -01 No. (e) LED Phase indicating lamp RYB- 1 SET (f) Timer switch of analogue type ,-01 No. (g) Modular Contactor, 40A, 3 module-4 Nos .
Repairs to LT panels/LT feeder piller boxes by carrying out through check all eletrical connections, lugs, busbar voltmeter, ammeter, cableglands, insulator on busbar, and tighting all connections properly with proper size of new nut bolts washer as per the site requirements and insulation of busbar with colour code insuation tapes and preparation of surfaces internal and external of panels/feeder piller boxes by cleaning with dry cloth/removal dust particles by using air blower and scratching the old painted surfaces as directed and painting two coat of synthetic enamel paint over a coat of red oxide prime rand writting existing letters/numbers or as directed and repair the existing PCC basement of the feeder piller box/LT panel as per site requirement or directed and preparation of old decorated/concrete surfaces and applying one coat of cement base paint and testing complete with all electrical connection made all as specified and directed by the Engr-in-Charge.
Supply only MCCB, 400 Amps, 25kA, four pole with thermal and magnetic release complete all as specified and as directed. Make:-Schneider/Siemens/ L&T/ ABB/ Legrand.
Supply only MCCB, 100 Amps, 25kA, four pole with thermal and magnetic release complete all as specified and as directed. Make:-Schneider/Siemens/ L&T/ ABB/ Legrand.
Supply only MCB, FP, 10kA, B series, 32 Amps including necessary connection and taking down old unserviceable one complete all as specified and as directed. Make:-Schneider/Siemens/ L&T/ ABB/ Legrand.
Supply only LCD Multifunction meter with CT complete all as specified and as directed. Make:- L&T/ABB/Schneider/Siemens/Legrand.
Supply only LED indicating lamp RYB suitable for electric panels complete complete all as specified and as directed by the Engr-in-Charge. Make:- L&T / Siemens / RR Micro/ BCH/ Schneider/ GE./ ABB
Supply only Timer switch of analogue type for street light fittings, module 1 complete all as specified and as directed. Make:- L&T / Schneider / ABB / SIEMENS/ Legrand/C&S.
Supply and Fix Modular Contactor, 40A-4NO, 3 module complete all as specified and as directed. Make:- L&T / Schneider / ABB / SIEMENS/Legrand.
Supply only Changeover Switch, in sheet steel enclosure, four pole, 250 Amps, Manual type, 415 V complete all as specified and as directed. Make:- As specified in list of make given in Particular specification here in after.
Supply and fix MCCB, 400 Amps, 36kA, four pole, 415 V with thermal and magnetic release, Icu =Ics=100%, IP43, IK-09 adustable type, overload setting 70-100%of input including necessary connection and taking down old unserviceable one complete all as specified and as directed. Make:-L&T/ Legrand/ ABB/ Schneider/ Siemens.
Supply and fix MCCB, 250 Amps, 36kA, four pole, 415 V with thermal and magnetic release, Icu =Ics=100%, IP43, IK-09 adustable type, overload setting 70-100%of input including necessary connection and taking down old unserviceable one complete all as specified and as directed. Make:-L&T/ Legrand/ ABB/ Schneider/Siemens.
Supply and fix MCCB, 200 Amps, 36kA, four pole, 415 V with thermal and magnetic release, Icu =Ics=100%, IP43, IK-09 adustable type, overload setting 70-100%of input including necessary connection and taking down old unserviceable one complete all as specified and as directed. Make:L&T/ Legrand/ ABB/ Schneider/Siemens.
Supply and fix MCCB, 160 Amps, 36kA, four pole, 415 V with thermal and magnetic release, Icu =Ics=100%, IP43, IK-09 adustable type, overload setting 70-100%of input including necessary connection and taking down old unserviceable one complete all as specified and as directed. Make:L&T/ Legrand/ ABB/ Schneider/Siemens.
Supply and fix MCCB, 100 Amps, 25kA, four pole, 415 V with thermal and magnetic release, Icu =Ics=100%, IP43, IK-09 adustable type, overload setting 70-100%of input including necessary connection and taking down old unserviceable one complete all as specified and as directed. Make:-L&T/ Legrand/ ABB/ Schneider/Siemens.
Supply and fix MCB, SP, 10kA, B series, 6-32 Amps including necessary connection and taking down old unserviceable one complete all as specified and as directed. Make:-L&T/ Schneider/ ABB/ Schneider/Legrand
Supply and fix MCB, TP, 10kA, B series, 63 Amps including necessary connection and taking down old unserviceable one complete all as specified and as directed. Make:-L&T/ Schneider/ ABB/Schneider/ Legrand
Supply and fix MCB, TP, 10kA, B series, 32 Amps including necessary connection and taking down old unserviceable one complete all as specified and as directed. Make:-L&T/ Schneider/ ABB/ Schneider/Legrand
Materials and labour Earthing complete with galvanised steel earth plate electrode 60 Cm x 60 Cm x 6.00 mm thick buried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI strips 32x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel, GI strip projected by 40 mm bore light grade GI pipe and other end connected to earth test point as directed including funnel with watering pipe 20 mm bore medium grade galvanised iron, wire mesh, charcoal or coke common salt laid in alternative layer of 15 cm (complete thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1, 50 mm thick pre-cast RCC (1:2:4) type B-1 normal mix cover slab reinforced with 8 mm dia TMT bar 10 Cm c/c both ways and single handle of 10 mm dia round bar including necessary excavation, earth work etc. in soft / loose soil and disposal pf soil to a distance n. exc. 50 m and necessary testing on completion all as shown in electrical plate No. 3 MES Schedule Part-I including taking out of old unserviceable earth pit with all accessories complete all as specified and as directed. Note:- Earthing strip upto 7.5m shall deemed to be included in the rate quoted ahaist these Item and beyond 7.5m shall be measured and paid relevant item of these schedule here in after.
Supply and fix Straight through XLPE cable jointing kit 1100V ( Earthed) grade for indoor termination heat shrinkable type complete with jointing materials and accessories suitable for XLPE armoured aluminium conductor cable of size 25 Sqmm to 50 Sqmm 3.5 core complete all as specified and as directed.
Supply and fix Straight through XLPE cable jointing kit 1100V ( Earthed) grade for indoor termination heat shrinkable type complete with jointing materials and accessories suitable for XLPE armoured aluminium conductor cable of size 70 Sqmm to 150 Sqmm 3.5 corecomplete all as specified and as directed.
Supply and fix Straight through XLPE cable jointing kit 1100V ( Earthed) grade for indoor termination heat shrinkable type complete with jointing materials and accessories suitable for XLPE armoured aluminium conductor cable of size 185 Sqmm to 300 Sqmm 3.5 core complete all as specified and as directed.
Supply and fix LED indicating lamp RYB suitable for electric panels including making connection complete including taking down old unserviceable one complete all as specified and as directed by the Engr-in-Charge. Make:- L&T / Siemens / RR Micro/ Legrand/ Schneider/ ABB
Supply and fix LED decorative post top lantern, 35/40 Watt capacity for energy efficient conservation upto 50% and with eco friendly lighting system with all accessories and necessary connection including taking down old unserviceable one complete all as specified and as directed. Make:- Havells Cat Part No. RUBYPT35WLED830PSYMTOPC or Surya cat part No. SLE PT 40W-ETPP or Make:- Bajaj cat part No.BGCL 40W LED WH
Supply and fix LED IP65 rated inverted Pyramid Tripod type, LED Bollard 8/9/10 Watt capacity with soft 360° light distribution with all accessories and necessary connection including taking down old unserviceable one complete all as specified and as directed. Make:- Crompton cat part No. LBLSN 10 CDL or Make:- Surya cat part No. SLE BL 9W- BLK800 or Make:- Havells cat part.CONEXXGBLS8WLED830SPSYMTOPCM.
Supply & Fixing in replacement aviation obstruction light in yellow coloured die cast aluminium alloy housing with built in 75 VA step up transformer, heat resistant, clear thick glass dome mounted on hinged die-cast aluminium ring secured to the body by two studs and wing nuts with neon spiral lamp plugged into spring loaded high tension nylon socket and wired upto the terminal block having degree of protection- IP 54 including dismantling and taking down existing unserviceable/worn out aviation light from RCC over head tank of height not more than 21.0 Mtr complete in all respect as specified and directed. Make:- Bajaj Cat part No BGAV 302 LED or equivalent model of make:- Havells / Crompton.
Material and labour Cross arms of MS channel or angle sections of required size and shape including clamps, D clamps, eye hooks, back plate with bolts, nuts and washers, drilling holes for bolts inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified & directed at site including dismantling old unserviceable cross arm.
Materials and Labour Glow sign board along with pipe bracket with accessories including 0.20mm thick white rubber coated vinyl or synthetic vinyl 1 sheet painted with scotch / computer inject printing with outdoor ink and with 300x 720 DPI and also 140 DPI laminated with average 0.15mm high quality weather procted with chemical and including 1.5mm thick poly carbonated PVC milky / transparent sheet drawing art work computer designing including 22 SWG sheet frame work arrangement for fixing LED tube light fittings 18/20 Watt 1no per sqm with necessary connection with 1.5 Sqmm single core copper conductor cable and 50mm dia Light grade pipe 3Rm x 2 Nos duly grouted 0.80m deep in PCC type B2 (1:2:4, using 40mm graded crushed stone aggregates) including all necessary fixing arrangement & tools and plants complete all as directed by Engineer-in-Charge including taking down old unserviceable glow sign board complete.
Supply and erecting steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts and screw as specified, type 410 SP-31, 9 Metre long including two coats of aluminium paint over one coat of red oxide primer including 200mm thick PCC type D2 ( 1:4:8, using 40mm graded crushed stone aggregates) for pole foundation bed with dismantling of old unserviceable pole and PCC complete all as specified and as directed by the Engr-in-Charge. Note:- Rates quoted shall be deemed to be inclusive of following works:- (a) Material and labour for painting of pole externally with one coat of black bituminous paint (upto planting depth) and above plinth block concrete collar with two coats of aluminium paint over a coat of red oxide primer including preparation of surface. (b) Material and labour for writing letter or figures (Block, Roman, Italic as Indian) with thick synthetic enamelled paint of apprised shade n exc 5 Cm height including numbering of pole all as directed by EIC.
Materials and Labour Scrapping, cleaning and preparation of surfaces of all electric pole and applying black bituminious paint to the section of 15Cm x 15 Cm on 2 m from ground level for writing MES no/ pole no of size 15mm x 120mm in white synthetic enamel paint for each pole complete all as directed by Engineer-in-Charge.
Routine and periodical cleaning the inside area of 11 KV Sub Stations including cutting and removal/uprouting of unwanted grass/bushes, small trees near all around sub station and pump houses complex complete including surface dressing and leveling by surface excavation wherever as required or as directed.
Routine and periodical work required for trimming / cutting of tree branches of any girth, touching / obstructing the over head lines of HT/LT Poles of three phase distribution system at places not more than 40 Mtr span distance so as to keep minimum 2.0 mtr clearance all around the lines and poles with due care after taking proper electric shutdown from concern executive including disposal thereof( trimmed branch) to a distance not exceeding 100 mtr complete all as specified and directed.
Supply and fix in repairs GI strip of size 32 x 6 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as directed.
Supply and fix as in repair Air termination aluminium single pointed rod 12 mm dia, 300 mm long complete all as specified and as directed.
Supply and fix in repair test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25 mm drilled and screwed including 3 nos 8mm dia 25mm long hex head screw complete all as specified and as directed.
Supply and fix New generation energy saving and environmental friendly long life LED street light luminaries 45 watt with 50mm dia light grade GI pipe bent to shape of 45º 1.5 long, made up of pressure die cast aluminium housing with high power LED as lighting source and lens separate driver compartment with IP66 protection after taking down old unserviceable one complete all as specified and as directed by the Engr-in-Charge. Make:- Surya cat part No. SLE UL 45W IP66 (LXN) or Make:- Bajaj BRTFG 45W LED V2 or make:- Crompton cat part No.LSTS 45 CDL M.
Supply and fix New generation energy saving and environmental friendly long life LED street light luminaries 90 watt with 50mm dia light grade GI pipe bent to shape of 45º 1.5 long, made up of pressure die cast aluminium housing with high power LED as lighting source and lens separate driver compartment with IP66 protection after taking down old unserviceable one complete all as specified and as directed by the Engr-in-Charge. Make:- Crompton cat part No. LSTP-90-CDL-M or Make:- Bajaj cat part No. BRTFG 90W LED I V2 or Make:- surya cat part No. SLE UL 90W IP66 (LXN)
Supply and fix LED flood light luminarie of 70/80 Watt capacity, pressure die cast with IP66 proction, efficient high output emitter LED including all accessories and neccsaary connection complete after taking down old unserviceable one complete all as specified and as directed by the Engr-in-Charge. Make:- Crompton Cat Part No. LFL 80 CDL/60-M or Make:- Havells cat part No. JETAPROFFL70WLED757LTG Or make:- Bajaj cat Part No.BJFL 80W LED I WW.
Material and labour Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size including taking down old unserviceable Danger notice plate complete all as specified and directed.
Taking down existing LED street light/ security light fittings carefully (any capacity any type) from pole, carrying out necessary repairing at E/M yard and refixing into the existing location including replacement of unserviceable/ defective LED driver, cleaning of acrylic cover with detergent and replacement of internal wiring with two runs of PVC insulated 1.5 Sqmm copper conductor cable from fittings to connector block and testing after refixing at site complete all as specified and directed . Note:- LED Driver required for replacement shall be measured and paid for separately as 'Supply only'.
Supply only Constant current LED driver, operating Voltage 180V-270V, AC 50/60 Hz, output Voltage 36V, DC/2.8 Amp, power factor 0.95 LED security light 90 watt complete all as specified and as directed by Engineer-in-Charge. Make:- Bajaj cat part No. BGD 36 240 5Y or equivalent model from make;- Philips / Crompton greves.
Supply only Constant current LED driver, operating Voltage 180V-270V, AC 50/60 Hz, output Voltage 36V, DC/2.8 Amp, power factor 0.95 for LED security light 45 watt complete all as specified and as directed by Engineer-in-Charge. Make:- Bajaj cat part No. BGD 70 065 5Y or equivalent model from make;- Philips / Crompton greves.
Supply and Fix Power factor correction MPP standard duly capacitor bank cylinder type, 440V, 1 KVAR and making electrical connection and testing including taking down old unserviceable capacitor complete all as specified and as directed. Make:- L&T/ Siemens/ Schneider/ ABB/ Legrand
Supply and Fix Power factor correction MPP standard duly capacitor bank cylinder type, 440V, 2 KVAR and making electrical connection and testing including taking down old unserviceable capacitor complete all as specified and as directed. Make:- L&T/ Siemens/ Schneider/ ABB/ Legrand
Supply and Fix Power factor correction MPP standard duly capacitor bank cylinder type, 440V, 3 KVAR and making electrical connection and testing including taking down old unserviceable capacitor complete all as specified and as directed. Make:-L&T/ Siemens/ Schneider/ ABB/ Legrand
Supply and Fix Power factor correction MPP standard duly capacitor bank cylinder type, 440V, 5 KVAR and making electrical connection and testing including taking down old unserviceable capacitor complete all as specified and as directed. Make:- L&T/ Siemens/ Schneider/ ABB/Legrand
Supply and Fix Power factor correction MPP standard duly capacitor bank cylinder type, 440V, 10 KVAR and making electrical connection and testing including taking down old unserviceable capacitor complete all as specified and as directed. Make:- L&T/ Siemens/ Schneider/ ABB/ Legrand
Supply and Fix Power factor correction MPP standard duly capacitor bank cylinder type, 440V, 20 KVAR and making electrical connection and testing including taking down old unserviceable capacitor complete all as specified and as directed. Make:- L&T/ Siemens/ Schneider/ ABB/Legrand
Supply and Fix Power factor correction MPP standard duly capacitor bank box type, 440V, 1 KVAR and making electrical connection and testing including taking down old unserviceable capacitor complete all as specified and as directed. Make:-L&T/ Siemens/ Schneider/ ABB/ Legrand
Supply and Fix Power factor correction MPP standard duly capacitor bank box type, 440V, 2 KVAR and making electrical connection and testing including taking down old unserviceable capacitor complete all as specified and as directed. Make:- L&T/ Siemens/ Schneider/ ABB/ Legrand
Supply and Fix Power factor correction MPP standard duly capacitor bank box type, 440V, 3 KVAR and making electrical connection and testing including taking down old unserviceable capacitor complete all as specified and as directed. Make:- L&T/ Siemens/ Schneider/ ABB/ Legrand
Supply and Fix Power factor correction MPP standard duly capacitor bank box type, 440V, 5 KVAR and making electrical connection and testing including taking down old unserviceable capacitor complete all as specified and as directed. Make:- L&T/ Siemens/ Schneider/ ABB/ Legrand
Supply and Fix Power factor correction MPP standard duly capacitor bank box type, 440V, 10 KVAR and making electrical connection and testing including taking down old unserviceable capacitor complete all as specified and as directed. Make:- L&T/ Siemens/ Schneider/ ABB/ Legrand
Supply and Fix Power factor correction MPP standard duly capacitor bank box type, 440V, 20 KVAR and making electrical connection and testing including taking down old unserviceable capacitor complete all as specified and as directed. Make:- L&T/ Siemens/ Schneider/ ABB/Legrand
Supply and Fix Capacitor duty contactor MOC 5 suitable for 415V, 3 Phase, 50 Hz capacitor bank, 1NO contact complete including taking down old unserviceable one , all as directed by Engineer-in-Charge. Make:-L&T/ Siemens/ Schneider/ ABB/ Legrand
Supply and Fix Capacitor duty contactor MOC 8.5 suitable for 415V, 3 Phase, 50 Hz capacitor bank, 1NO contact complete including taking down old unserviceable one , all as directed by Engineer-in-Charge. Make:- L&T/ Siemens/ Schneider/ ABB/ Legrand
Supply and Fix Capacitor duty contactor MOC 25 suitable for 415V, 3 Phase, 50 Hz capacitor bank, 1NO contact complete including taking down old unserviceable one , all as directed by Engineer-in-Charge. Make:-L&T/ Siemens/ Schneider/ ABB/ Legrand
Supply and Fix On/OFF Switch push button with element type suitable for APFC panels including taking down old unserviceable one complete all as directed by Engineer-in-Charge. Make:- L&T / Schneider / ABB/ Siemens/ Legrand.
Supply and fix PVC flexible pipe 25mm suitable for electric connection including taking down old unserviceable one complete all as specified and as directed by the Engr-in-Charge.
Supply and fix GI pipe, 40mm bore, light grade for protection & passing of LT cable fixed to pole/walls/laid under floor/roads complete including fittings/clamps as required at site all as specified for size of 40mm bore dia all as specified & directed at site including taking out old unserviceable one.
Supply and fix GI pipe, 50mm bore, light grade for protection & passing of LT cable fixed to pole/walls/laid under floor/roads complete including fittings/clamps as required at site all as specified for size of 50mm bore dia all as specified & directed at site including taking out old unserviceable one.
Supply and fix GI pipe, 100mm bore, light grade for protection & passing of LT cable fixed to pole/walls/laid under floor/roads complete including fittings/clamps as required at site all as specified for size of 80mm bore dia all as specified & directed at site including taking out old unserviceable one.
INDIA ELECTRICAL EQUIPMENTS
KWALITY CONSTRUCTION
G D TRADERS
BHARUKA ENTERPRISES
DILIP CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .