Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.3 LAccepted-AOC | L1 | Accepted-AOC 1ST LOWEST | |
| 2 | L2₹48.0 L+₹21,963.39 (0.46%)Rejected-Finance | L2 | Rejected-Finance 2ND LOWEST | |
| 3 | L3₹48.3 L+₹52,116.49 (1.09%)Rejected-Finance | L3 | Rejected-Finance 3RD LOWEST | |
| 4 | L4₹48.6 L+₹81,790 (1.71%)Rejected-Finance | L4 | Rejected-Finance 4TH LOWEST | |
| 5 | L5₹49.0 L+₹1.3 L (2.65%)Rejected-Finance | L5 | Rejected-Finance 5TH LOWEST |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
14 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER I GOS
GARRISON ENGINEER I GOPALPUR MILITARY STATION PO GOLABANDHA DIST GANJAM ODISHA 761052
ADDITION ALTERATION TO BUILDING NUMBER P 64 IN ZONE A AREA AT GMS UNDER GE I GOS
2022_MES_559448_1
8000/40/22-23/0939/E8
Open Tender
Civil Works
Item Rate
180 days
GOPALPUR-ON-SEA
PLEASE REFER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER I GOS
₹86,000
Yes
13 Dec 2022
22 Oct 2022
16 Nov 2022
22 Oct 2022
14 Nov 2022
7 Nov 2022
Amount
Demolition of Cement Concrete (unreinforced) of any description & in any position not otherwise specifically provided for complete all as specified & directed.
Demolition of Reinforced Cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified & directed.
Excavation in post holes (or similar holes) each not exceeding 0.50 cum, in soft/loose soil, getting out, returning filling in & ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering or removing surplus soil to a distance not exceeding 50 m & making good surface complete all as specified & directed.
M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate in foundations, filling & mass concrete complete all as specified & directed.
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS:1161-1998 grade St-240 complete all as specified & directed.
M&L for Fe 410-W (Gde E-250 quality A) Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified & directed.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified & directed.
M&L for preparation of new or previously untreated surfaces of any description, over 10 cm in width or girth, not otherwise described & apply two coat of synthetic enamel (ordinary tint) over & including one coat of red oxide, zinc chrome primer complete all as specified & directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Dismantling Framed work timber scantlings in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section complete all as specified & directed.
Dismantling asbestos cement (corrugated, semi corrugated etc) sheets in roof coverings including ridges complete all as specified and directed.
M&L Machine cut kota stone slab flooring 18-20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L Machine cut Kota stone slab flooring 18-20mm thick as in riser, steps & skirting, over cement mortar laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab incl rubbing, polishing & rounding to edges complete all as specified and directed.
M&L for 16 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.
Dismantling of floor, hearth, walls, roof tiles including bedding (but not backing), and rubbish off permises complete all as specified and directed.
M&L for Rendering 10 mm thick in cement mortar 1 : 4 for fixing of wall tiles complete all as specified and directed.
M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in sub base flooring average 25 mm thick surface finished even and rough (as in levelling course) to receive the topping layer complete all as specified and directed.
M&L for screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in CM 1:6 for laying of floor tiles complete all as specified and directed.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as speified and directed.
M&L for pre cast cement concrete 1:1.5:3, type A-1, using 20mm graded stone aggregate as in cover slabs (for manholes etc) and similar articles with plain faces, set in CM 1:4 complete all as specified and directed.
M&L for Mild steel TMT bars 6 to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as speified and directed.
M&L for Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as speified and directed.
M&L for hard core of gauge n exc 63 mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface all as specified and directed.
M&L for PCC 1:4:8 type D2 using 40 mm graded stone aggregate in foundations, filling & mass concrete complete all as specified & directed.
M&L Excavating over areas, n exc 1.5 m deep and getting out in soft/ loose soil complete all as specified and directed.
M&L for Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for foundation etc or for shafts, wells cesspits manholes pier holes etc not exceeding 10 Sqm on plan and not exceeding 1.5 m depth in soft /loose soil etc complete all as specified and directed.
M&L for Returning, filing in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in any type of soil etc complete all as specified and directed
M&L for Removing excavated material (Soil) exc. 250 m but n exc. 500 m and depositing where directed complete all as specified and directed.
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
M&L for Brick work with fly ash bricks straight or curved on plan exceeding 6 m mean radius complete built in cement mortar 1:6 complete all as specified and directed.
M&L for Brickwork with flyash bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and directed.
Taking down cement plaster on brick or concrete surface including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for Rendering 15 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces, finished even and smooth (without using extra cement) complete all as specified and directed.
M&L for applying 2mm thick Birla / JK Putty in two layers on newly plastered walls surfaces making absolutely even and smooth, rubbing with sand paper complete all as specified and directed.
M&L for applying 2mm thick Birla / JK Putty in two layers on old wall surfaces including complete removal of existing wall finish of any type with wire brush, brooming, dusting and finally washing with water to clean the surface absolutely free from any kind of foreign materials and making good minor cracks etc. and surfaces absolutely even and smooth, rubbing with sand paper complete all as specified and directed.
M&L for applying two coats of oil bound distemper on wall or concrete surfaces on prepared surfaces including, rubbing with sand paper complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs /blankets, any thickness, including cover fillets complete all as specified and directed.
S&F 12 mm thick plain Gypsum Board False Ceiling with GI frame including all necessary drilling cutting to fix electric items complete all as specified and directed with following:- (a) GI Grid channel 30x25x20 mm of 24 gauge fixed with rawl plug and screw 450 mm centre to centre alongwith perimeter walls. (b) GI channel made to shape 50x40x40 mm of 24 gauge placed @ 600 mm centre to centre from perimeter at wall except long wall (in one span). (c) GI intermediate runners of size 45x10x10 mm of 24 gauge fixed @ 1200 mm centre to centre leaving frame of one side walls (in other span). (d) GI sheet 25 mm wide and 20 mm gauge suspended fixed with steel fastner to roof ceiling and 1200 mm centre to centre including pluging of RCC Slab. (e) 12 mm thick gypsum board filling joints with POP and finishing complete with two coat of plastic emulsion paint over one coat of primer on ceiling.
Providing and fixing factory made uPVC white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. (Note: The unit rate quoted by contractor includes cost of glass and includes all other connected accessories.) (Area not exceeding 2.00 sqm)
Taking down chowkhat or frames exc 1.50 Sqm and n exc 4 Sqm each with shutters (without taking off shutters from the frame) and removing to store complete all as specified and directed
Taking down chowkhat or frames n exc 1.50 Sqm each with shutters (without taking off shutters from the frame) and removing to store complete all as specified and directed
S&F in repairs 7mm thick aluminium grills of make "Decogrill' model DG 104 surrounded by aluminium 'C' channel with mesh size 99 X 105 mm all as specified and directed.
M&L applying two coats of acrylic exterior weather proof emulsion paint over a coat of exterior primer on newly plastered wall surfaces/ old decorated wall surfaces, in case of old decorated wall surfaces includes complete removal of existing wall finish of any type with wire brush, brooming, dusting & finally washing with water to clean the surface absolutely free from any kind of foreign materials and making good minor cracks etc complete all as specified and directed.
M&L 75 mm thick PCC 1:3:6 type C-1 using 20mm graded aggregate as in plinth protection finishing even & fair without using extra cement laid in bays with construction, 6mm thick joints should be filled with bitumen mastic filling comprising of one part of heated bitumen 80/100 gde and three part of sand ( all by weight) complete all as specified and directed.
Taking down eaves gutters and rain water pipes of any size or pattern including all fittings etc complete all as specified and directed.
S&F PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints laid in floors, trenches complete all as specified and directed.
S&F PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints fixed to wall complete all as specified and directed.
S&F PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joints laid in floors, trenches complete all as specified and directed.
S&F PVC (SWR) pipes 75 mm bore Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F PVC(SWR) bends, any radius of 110 mm bore complete all as specified and directed.
S&F PVC(SWR) bends, any radius of 75 mm bore complete all as specified and directed.
S&F Stack clamps made out of 50x5 mm flat iron, 16mm dia round iron stays including bolts & nuts and securing ends of stays to wall or roof for 110 mm PVC pipe complete all as specified and directed.
S&F Stack clamps made out of 50x5 mm flat iron, 16mm dia round iron stays including bolts & nuts and securing ends of stays to wall or roof for 75 mm PVC pipe complete all as specified and directed.
M&L for hard core of gauge n exc 63 mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface all as specified and directed.
M&L for 100 mm thick cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as sub base of floor complete all as specified and directed.
M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in sub base flooring average 25 mm thick surface finished even and rough (as in levelling course) to receive the topping layer complete all as specified and directed.
M&L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors and pointed with grey pigment cement and pigments complete all as specified and directed.
M&L for screed bed or bedding layer of mortar 15 mm thick in CM 1:4 for laying floor finishes complete all as specified and directed.
M&L for Demolition and breaking up drain pipe (salt glazed ware, AC or reinforced concrete ) set in cement mortor for 150 mm internal dia of pipe com plete all as specified and directed.
M&L for salt glazed stoneware (SGSW) drain pipes laid in trenches of 150 mm internal diameter of pipe and jointed in CM 1:1 complete all as specified and directed.
M&L for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (½ round or ¾ section) in cement concrete 1:2:4 type B-1 smooth finished ,and reforming benching as required for 150 mm internal dia of pipe complete all as specified and directed.
M&L for cement concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid & tested for 150 mm bore of pipe with cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate complete all as specified and directed.
M&L in repairs salt glazed stone ware gully traps size 150 x 150mm, square or round mouthed, type ‘P’ including setting and jointing to drains with CM 1:1 including demolition of existing traps complete all as specified and directed. (Note: CI grating will be meaured separately).
M&L for pre cast cement concrete 1:1.5:3, type A-1, using 20mm graded stone aggregate as in cover slabs (for manholes etc) and similar articles with plain faces, set in CM 1:4 complete all as specified and directed.
Demolition of Reinforced Cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified & directed.
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in lintels upto 1.5 m clear span, coping, benching, bed block, lintel band, plinth courses etc and similar work including weathering,slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed.
S&F mild steel framed work such as grills, gratings etc with ends of bars shouldered and / or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walkways, railings,frame work of watertanks and similar work conforming to Fe -290 Gde E-165 complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in surface channels and drains complete all as specified and directed.
M&L Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc complete all as specified and directed.
M&L for add or deduct for each 25mm girth or part thereof over or under 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc complete all as specified and directed.
Taking down copper /aluminium point wiring (light, fan, bell,socket or power) complete including fixture and fittings such as switches , ceiling roses , pendent , regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces of walls, floors etc complete all as specified and directed at site.
Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as specified and directed.
Taking down carefully copper/aluminium Sub main wiring of any size from surface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed.
Taking down ceiling fan/ exhaust fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan blades and deposit to MES store yard of AGE E/M Gopalpur on Sea complete all as specified and as directed.
M&L for point wiring with 1.5 Sq mm single core PVC insulated unsheathed copper FRLS multi stranded conductor cable in and including Concealed PVC conduit of size 20/25mm ISI marked inclusive of tees ,bend ,elbows etc upto and including sunk in anodized pressed steel box for housing switch socket etc with white laminated 3 mm thick hylam sheet cover ISI marked of suitable size complete including PVC insulated multi stranded copper conductor 1.5 Sq mm FRLS cable as earth wire to common earth dolly for connection to ceiling rose to earth terminal including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed by Engr-in-charge for One light point controlled by one, one way switch 5 Amps.
All as per item no. 80 but for One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator
All as per item no. 80 but forOne 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
All as per item no. 80 but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad.
All as per item No 80 here in before but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly.
S & F for Switch Piano type single pole 5 amp, 230 Volts complete all as specified and directed at site.
S & F for Switch Piano type single pole 15 amp, 230 Volts complete all as specified and directed at site.
S & F for socket outlet 2 in 1 , 5 pin, 5 amp, 230 Volts complete all as specified and directed at site.
S & F for socket outlet 2 in 1 , 5 pin, 5/15 amp, 230 Volts complete all as specified and directed at site.
S & F for Ceiling rose, surface Bakelite with 3 terminals, ISI marked for batten fitting complete all as specified
S & F for stepped type electronic fan regulator flushType complete all as specified and directed at site.
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 10 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 10.0 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Two runs of 10 sqmm cable,one run of 10 sqmm cable and one run of PVC conduit will be measured as one unit.
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 4 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 4.0 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Two runs of 4.0 sqmm cable,one run of 4.0 sqmm cable and one run of PVC conduit will be measured as one unit.
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 2.5 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 2.5 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Two runs of 2.5 sqmm cable,one run of 2.5 sqmm cable and one run of PVC conduit will be measured as one unit.
S & F for sheet metal enclosure MCB DB SPN 12 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
S & F for MCB Single pole and neutral rated capacity 63 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
S & F for MCB Single pole rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
S & F for ceiling fan, 230 Volts, 50Hz, 1200 mm sweep with down road, canopy, blades, BLDC motor etc and service value of the fan shall be greater than 6.1 as per BIS with necessary accessories and electrical connections from ceiling rose to fan teriminal including writting the MES Number with synthetic enamel paint complete all as specified and as directed.
S & F for wall mounted LED tube light fitting 20 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouput box type fitting, 230 volts and intregrated electronic driver connector block etc with warranty option of 5 years from date of installation complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. Make :- Make Havells Cat part No LUMILINEBS20WLED865SPCWH or its equvalent in Philips, CG.
S & F for Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 for security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 35 watts with pre wired and necessary mounting arrangements and provision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed by Engineer- in-charge. Make :- Bajaj Cat part No ENXT P 24L WH CR PC SD (Edge plus series) or its equvalent in Philips, Wipro.
S & F for PVC non-metallic rigid conduit ISI marked heavy duty white/ Ivory colour and its accessories heavy duty ISI marked of size 20 mm dia for LAN, telephone and TV connections including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed.
M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to GI earth wire 4mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia. medium grade protection pipe for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron pipe light grade 20 mm dia, PCC Chamber, CI frame and cover, MS funnel with wire mesh all as shown in electrical plate no 3 of SSR part I including excavation and earthwork in any type of soil/strata and testing on completion. Note :- GI earth wire 4 mm dia and 15 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted.
S&F air curtain 6ft with censor, 220 volts, 50 Hz complete all as specified and directed
S&F ultra modern slim recess mounting luminaire with high performance LEDs, suitable for mounting with armstrong/ grid ceiling of size 2x2 ft with capacity 36 watts, 50 Hz complete all as specified and directed. Make : Havells cat part No VENUSNEO2X2PLR36WLED857STTR
M&L for round metal iron metal clamp fan hanger brass hook roof hanging hook suitable to hang ceiling fan of 1200/1400 mm complete all as specified and directed
M&L for alloy steel D hook hanger (Heavy duty) with M10X75MM fastners for hanging ceiling fan of size 1200/1400mm complete all as specified and directed
Supply and fix VTPN 12 way 415 V double door with capacity of fixing 160 Amps MCCB complete all as specified and directed. Make- Legrand Cat Part No EKINOX 507728 or equivalent.
MCCB 4 Pole , 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA complete all as specified and directed.
Taking down existing three phase electric energy meter of any capacity after disconnecting all necessary electrical connections and deposit to MES store yard of AGE E/M Gopalpur on Sea and refixing the same after complete wiring of the bldg all as specified and as directed.
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and directed.
Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 metre in depth and getting out soft/loose soil, complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick, complete all as specified and directed by Engr-in-Charge.
Supply dry sand for cushioning to underground cables 8cm thick before laying cable and 15cm thick after lying and streching the cable, complete all as specified and directed by Engr-in-Charge. Note :- For payment purpose punned thickness shall be measured.
Removing surplus soil to a distance n.exc 50m and deposited where directed at a level not exceeding 1.50 m above the starting point, complete, all as specified and directed by Engr-in-Charge.
Sub class ‘B brick, old size, as cable protection cover, laid dry, flat, transversally along the length of cable, on sand cushioning, with width equal to the length of the brick, complete all as specified and directed by Engr-in-Charge.
M&L for laying of steel water tube medium grade under road/ path of bore 80 mm complete all as specified and directed by Enhr-in-Charge
M&L for laying in replacement XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 Sqmm 4 Core complete
M&L for laying in replacement XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 Sqmm 3.5 Core complete
M&L for laying in replacement XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 Sqmm 3.5 Core complete
M&L for laying in replacement XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 70 Sqmm 3.5 Core complete
M&L for laying in replacement XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 95 Sqmm 3.5 Core complete
Earthing complete with galvanised steel earth plate electrode 600x600x6mm burried directly in ground not less than 2.25 mtr deep below normal ground level with top edge of earth plate not less than 1.5mtr below normal ground level connected to the Galvanised iron strip 32x6mm size by means of bolts ,nuts,check nuts and washers of galvanised iron and 32x6mm GI strip procted by provision of GI light grade pipe 40 mm bore incl provision of concrete pit in PCC1:2:4 type B-1, using 20 mm graded stone aggregates with 40 mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg /Sqm and 6mm dia bar handle ,excavation and earth work in any type of soil ,charcoal dust and salt light grade GI watering pipe 20 mm bore with funnel and wire mesh and medium grade GI protection pipe 15mm bore 5 Mtr long and GI strip upto main earthing of pole complete all as shown in electrical plate No 3 of MES Sch 2009 Part-I all as specified and directed. Notes:- (i) Main earthing strip from earth plate electrode to test point upto length of 7.5 metres length shall deem to be included in the unit rate quoted against this item. (ii) GI protection pipe & earthing lead beyond 7.5 metres shall be measured and paid for seperately under appropriate item of Sch A part-I. (iii) On testing after completion if desired resistanace is not obtained, the contrator shall redo the earthing without any extra cost to the department.
M&L for removing the existing LT panel by breaking the PCC from the pedastal, disconnecting the existing cable and placing at a suitable palce as shown by Engr-in-Charge by doing PCC, connecting the cable and testing and commisioning complete all as specified and directed. Note :- Before staring the work for removal the contractor has to take permission from the JE concerned for shutdown. Damage occured if any during the work will be paid by the contractor at no extra cost. Items extra required for the execution of work will be measured and paid against separate items in this BOQ
Supply and fixing cable jointing kit for 1.1 KV (Earthed) grade cable for heat shrinkable straight end termination kit outdoor type complete with jointing material and accessories suitable for XLPE, LT cable, 1100 volts grade of size 25 to 50 Sqmm 4 core complete all as specified and directed by Engr-in-Charge. Make - 3M or equivalent
Supply and fixing cable jointing kit for 1.1 KV (Earthed) grade cable for heat shrinkable straight end termination kit outdoor type complete with jointing material and accessories suitable for XLPE, LT cable, 1100 volts grade of size 70 to 120 Sqmm 4 core complete all as specified and directed by Engr-in-Charge. Make - 3M or equivalent
Boring of holes horizontally for laying of 80mm dia pipe (minimum depth 0.60 Mtr from top level) under road, Pavement, hard standing complete all as specified and directed.
Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 metre in depth and getting out soft/loose soil, complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick, complete all as specified and directed by Engr-in-Charge.
Removing surplus soil to a distance n.exc 50m and deposited where directed at a level not exceeding 1.50 m above the starting point, complete, all as specified and directed by Engr-in-Charge.
Supply and laying for 3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings of outer dia 110MM laid in trenches. complete all as specified and directed
Supply and laying for 3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings of outer dia 40 MM laid in trenches. complete all as specified and directed
Supply and laying for 3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings of outer dia 25 MM laid in trenches. complete all as specified and directed
Supply and fixing Sluice Valve Class PN 1.6 size 100 mm dia complete as per requirement on the site
S&F PP-R Gate valves (brass insert) as per requirement of the site of size 25 mm complete all as specified and directed
S&F PP-R Gate valves (brass insert) as per requirement of the site of size 40 mm complete all as specified and directed
Making connection of PP-R distribution branch with PP-R main of 100 MM sizes by providing and fixing tee including cutting and making fusion joint etc
Making connection of PP-R distribution branch with PP-R main of 16-40 MM sizes by providing and fixing tee including cutting and making fusion joint etc
Boring across the road/ hard surface with mechanical boring equipment not less than 50 mm bore complete all as specified and directed
M/S. KISHAN ENGINEERING
DHABALESWAR ENGINEERING WORKS
M/S JAGANNATH SASMAL
M/s MAA BHAIRABI ENTERPRISES
HARAGOURI SUPPLIERS
M/S SIWALIK AND CO
G.KRISHNA MURTHY AND PARTNERS
M/s Ats Electricals
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .