| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹1.2 Cr | L1 | Accepted-AOC Being 1st lowest |
| 2 | L2₹1.2 Cr+₹63,837.30 (0.52%)Rejected-Finance SHOP NO 106 1ST FLOOR ASHOKA SHOPPING CENTRE LT ROAD MUMBAI 400001 | MUMBAI | MUMBAI | MAHARASHTRA | 400001 | ₹1.2 Cr+₹63,837.30 (0.52%) | L2 | Rejected-Finance Being 2nd lowest |
| 3 | L3₹1.2 Cr+₹1.6 L (1.31%)Rejected-Finance 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | ₹1.2 Cr+₹1.6 L (1.31%) | L3 | Rejected-Finance Being 3rd lowest |
| 4 | L4₹1.3 Cr+₹4.0 L (3.22%)Rejected-Finance | ₹1.3 Cr+₹4.0 L (3.22%) | L4 | Rejected-Finance Being 4th lowest |
| 5 | L5₹1.3 Cr+₹5.4 L (4.37%)Rejected-Finance | ₹1.3 Cr+₹5.4 L (4.37%) | L5 | Rejected-Finance Being 5th lowest |
| Sl No | Description | Qty | Unit | somnath engineering corporation L5 | pk Enterprises L2 | RADHA ENTERPRISE L8 | BRITE INDUSTRIES L6 | Shree Ayyappa Engineering L1 | cooltech engineering services L7 | DARSHAN CONSTRUCTION Co. L4 | sapana enterprises L3 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | PART - I :
(a) B/R Works
Dismantling Asbestos cement (corrugated, semi corrugated, etc.) sheets in roof coverings, complete all as specified and directed by Engr-in-Charge. | 285 | Sqm | 30 ₹8,550 | 20 ₹5,700 | 37 ₹10,545 | 35 ₹9,975 | 10 ₹2,850 Lowest | 33 ₹9,405 | 28 ₹7,980 | 23 ₹6,555 |
| 2.00 | Supply and Fix Pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed by Engr-in-Charge. | 215 | Sqm | 850 ₹1,82,750 | 837 ₹1,79,955 | 861 ₹1,85,115 | 650 ₹1,39,750 Lowest | 830 ₹1,78,450 | 853 ₹1,83,395 | 875 ₹1,88,125 | 950 ₹2,04,250 |
| 3.00 | Supply and Fix Pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet to be used as crimp curve 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed by Engr-in-Charge. | 30 | Sqm | 850 ₹25,500 | 839 ₹25,170 | 857 ₹25,710 | 750 ₹22,500 Lowest | 830 ₹24,900 | 851 ₹25,530 | 890 ₹26,700 | 900 ₹27,000 |
| 4.00 | Supply and Fix Pre- painted galvalume aluminium zinc coating GI based plain steel sheet to be used as valley gutter 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed by Engr-in-Charge. | 40 | Sqm | 750 ₹30,000 | 741 ₹29,640 | 757 ₹30,280 | 700 ₹28,000 Lowest | 750 ₹30,000 | 754 ₹30,160 | 750 ₹30,000 | 760 ₹30,400 |
| 5.00 | Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed by Engr-in-Charge. | 16 | Qtl | 1,600 ₹25,600 | 1,515 ₹24,240 | 1,654 ₹26,464 | 530 ₹8,480 | 700 ₹11,200 | 1,616 ₹25,856 | 1,490 ₹23,840 | 400 ₹6,400 Lowest |
| 6.00 | Supply and Fix for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc, complete all as specified and directed by Engr-in-Charge. | 1,500 | Kg | 130 ₹1,95,000 | 117 ₹1,75,500 | 137 ₹2,05,500 | 125 ₹1,87,500 | 124 ₹1,86,000 | 131 ₹1,96,500 | 135 ₹2,02,500 | 107 ₹1,60,500 Lowest |
| 7.00 | Supply and Fix for mild steel Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165, complete all as specified and directed by Engr-in-Charge. | 100 | Kg | 165 ₹16,500 | 153 ₹15,300 | 171 ₹17,100 | 180 ₹18,000 | 142 ₹14,200 Lowest | 167 ₹16,700 | 158 ₹15,800 | 155 ₹15,500 |
| 8.00 | Material and Labour for preparing new or previously untreated steel surface of any description over 10cm in width or girth and applying 2 coats of synthetic enamel paint over one coat of red oxide primer, complete all as specified and directed by Engr-in-Charge. | 60 | Sqm | 138 ₹8,280 | 127 ₹7,620 | 145 ₹8,700 | 140 ₹8,400 | 144 ₹8,640 | 141 ₹8,460 | 132 ₹7,920 | 110 ₹6,600 Lowest |
| 9.00 | Taking down chowkhats or frames exc 1.5sqm but not exc 4 sqm each but with shutter (without taking off shutter from the frame) , complete all as specified and directed by Engr-in-Charge. | 15 | Each | 300 ₹4,500 | 285 ₹4,275 | 317 ₹4,755 | 350 ₹5,250 | 254 ₹3,810 | 313 ₹4,695 | 260 ₹3,900 | 210 ₹3,150 Lowest |
| 10.00 | Taking down chowkhats or frames not exc 1.5sqm each but with shutter (without taking off shutter from the frame) , complete all as specified and directed by Engr-in-Charge. | 4 | Each | 280 ₹1,120 | 263 ₹1,052 | 287 ₹1,148 | 250 ₹1,000 | 264 ₹1,056 | 283 ₹1,132 | 250 ₹1,000 | 220 ₹880 Lowest |
Tender Value
₹1.3 Cr
EMD Value
₹2.0 L
Closing Date
18 Aug 2025, 6:00 pmClosed
CWE Karanja
CWE Karanja, Naval Station Karanja, Uran, Raigad, Maharashtra
COMPREHENSIVE REPAIR / MAINTENANCE OF CHILLERS, AHU UNIT, COOLING TOWER, COMPRESSOR, CONDENSOR, EXPANSION VALVES OF AC PLANT ALONGWITH ALLIED B/R WKS OF ZONE IV LOCATIONS OF NAD NON EXPLOSIVE AREA AT NAVAL STATION KARANJA
2025_MES_721500_1
84463-K/E8
Open Tender
Electrical and Maintenance Works
Item Rate
420 days
Naval Station Karanja
Please refer Tender Documents
8 documents required · 8 mandatory
₹1,000
GE (NW) Karanja
₹2.0 L
3 Oct 2025
19 Jul 2025
20 Aug 2025
19 Jul 2025
18 Aug 2025
9 Aug 2025
Amount
PART - I : (a) B/R Works Dismantling Asbestos cement (corrugated, semi corrugated, etc.) sheets in roof coverings, complete all as specified and directed by Engr-in-Charge.
Supply and Fix Pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed by Engr-in-Charge.
Supply and Fix Pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet to be used as crimp curve 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed by Engr-in-Charge.
Supply and Fix Pre- painted galvalume aluminium zinc coating GI based plain steel sheet to be used as valley gutter 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed by Engr-in-Charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed by Engr-in-Charge.
Supply and Fix for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc, complete all as specified and directed by Engr-in-Charge.
Supply and Fix for mild steel Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165, complete all as specified and directed by Engr-in-Charge.
Material and Labour for preparing new or previously untreated steel surface of any description over 10cm in width or girth and applying 2 coats of synthetic enamel paint over one coat of red oxide primer, complete all as specified and directed by Engr-in-Charge.
Taking down chowkhats or frames exc 1.5sqm but not exc 4 sqm each but with shutter (without taking off shutter from the frame) , complete all as specified and directed by Engr-in-Charge.
Taking down chowkhats or frames not exc 1.5sqm each but with shutter (without taking off shutter from the frame) , complete all as specified and directed by Engr-in-Charge.
Material and Labour for greasing and easing in position of mild steel rolling shutters of area not exc 10sqm each for full movement and for easy operation for shutters including taking down of old Shutter, complete all as specified and directed by Engr-in-Charge.
Material and Labour for greasing and easing in position of mild steel rolling shutters of area exc 10sqm and not exc 20sqm each for full movement and for easy operation for shutters including taking down of old Shutter, complete all as specified and directed by Engr-in-Charge.
Material and Labour for greasing and easing in position of mild steel rolling shutters of area exc 20sqm and not exc 50sqm each for full movement and for easy operation for shutters including taking down of old Shutter , complete all as specified and directed by Engr-in-Charge.
Material and Labour in repair for Opening of rolling shutter hood cover, greasing to gears, helical spring and guide channels and refixing all accessories back in position of area not exc 10sqm each, complete all as specified and directed by Engr-in-Charge.
Material and Labour in repair for Opening of rolling shutter hood cover, greasing to gears, helical spring and guide channels and refixing all accessories back in position of area exc 10sqm and not exc 20sqm each , complete all as specified and directed by Engr-in-Charge.
Material and Labour in repair for Opening of rolling shutter hood cover, greasing to gears, helical spring and guide channels and refixing all accessories back in position of area exc 20sqm and not exc 50sqm each, complete all as specified and directed by Engr-in-Charge.
Supply and Fix Steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type including taking down of old Shutter, complete all as specified and directed by Engr-in-Charge.
Supply and Fix Steel rolling shutters, with out ball bearing, thickness of laths 1.00mm as specified including top cover, anchoring rod, hasp and staple and erected in position as indicated, complete: gear operated type with bevel gear box and crank handle including taking down of old Shutter complete all as specified and directed by Engr-in-Charge
Material and Labour for preparing new or previously untreated steel surface of any description over 10cm in width or girth and applying 2 coats of aluminium paint over one coat of red oxide primer, complete all as specified and directed by Engr-in-Charge.
Material and Labour for preparing old painted steel surface of any description over 10cm in width or girth and applying one coat of aluminium paint, complete all as specified and directed by Engr-in-Charge.
Supply and Fix for Providing and fixing in repair ball bearing for rolling shutters, complete all as specified and directed by Engr-in-Charge.
Supply and Fix Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 50 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30 mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. (Note: stainless steel butt hinges and necessary SS screws shall be paid separately)
Supply & Fixing solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube and edges will be painted to match will printed sheet fixed in opening as per specification & drawings, complete all as specified and directed by Engr-in-Charge.
Supply and fixing factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of mild steel tube top & bottom rail mild steel frame shall be covered with heat moulded plain colour PVC “C” channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap inserted for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the mild steel frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement supplying & fixing in the frame at site as per specification and drawing, complete all as specified and directed by Engr-in-Charge.
Supply and Fix extruded aluminium alloy handles fabricated type anodized 150 mm size, complete all as specified and directed by Engr-in-Charge.
Supply and Fix stainless steel dash fasteners of 8 mm dia and 75 mm long bolt for fixing item No 22.00 here-in-before, complete all as specified and directed by Engr-in-Charge.
Material and Labour for Providing and fixing IS : 12817 marked stainless steel butt hinges of size 100 x 58 x 1.90mm with stainless steel screws etc, complete all as specified and directed by Engr-in-Charge.
Supply and Fix 200mm long aluminium anodized barrel tower bolts of extruded sections, complete all as specified and directed by Engr-in-Charge.
Supply and Fix 300mm long aluminium alloy, anodized sliding door bolts with hasp & staple (bolt type) and fixing clips of sheet cost of extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy, complete all as specified and directed by Engr-in-Charge.
Material and Labour for PCC 1:3:6, type C1 (using 20 mm graded aggregate) coping or filling for hold fast without using extra cement, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair 8 to 9 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12 micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit in existing false ceiling frame work, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair 4 mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/ GI/ Aluminium framework with screws in ceiling flat or sloping, complete all as specified and directed by Engr-in-Charge. Note:- Item rate shall be include any height of Bldgs for scaffolding as all arrangement.
Material and Labour for preparing asbestos & ceiling board surfaces and applying two coats of oil bound distemper over a coat of chalk whitening on plastered surfaces , complete all as specified and directed by Engr-in-Charge. Note:- Item rate shall be include any height of Bldgs for scaffolding as all arrangement.
Dismantling wall and ceiling boards or insulation boards, any thickness, any description, including cover fillets , complete all as specified and directed by Engr-in-Charge. Note:- Item rate shall be include any height of Bldgs for scaffolding as all arrangement.
Supply and Fix Anodised aluminium snap grid of size 600x600 mm frame work for false ceiling complete all as specified and directed by Engr in Charge.
Supply and Fix Hangers 6 mm dia GI ( upto 1200 mm length ) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long , complete all as specified and directed by Engr-in-Charge.
Supply and Fix 4 mm thick asbestos cement plain building board fixed to aluminium grid frame work in ceiling , complete all as specified and directed by Engr-in-Charge. Note:- Item rate shall be include any height of Bldgs for scaffolding as all arrangement.
Demolition of cement concrete in ground floor and paving not exceeding 15cm thick below or above ground level un re-inforced, complete all as specified and directed by Engr-in-Charge.
Material and Labour for PCC 1:4:8 type D2, using (40 mm graded aggregate) ,100 mm thick as in sub base of flooring, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repairs PVC tiles /sheets, of 2mm thick laminated plain coloured homogenous, laid with approved rubber based adhesive in floors, complete all as specified and directed by Engr-in-Charge.
Material and Labour for PCC 1:2:4 type B2, using (40 mm graded aggregate) ,100 mm thick as in flooring , complete all as specified and directed by Engr-in-Charge.
Material and Labour PCC 1:3:6, type C2 (using 40 mm graded aggregate) 75 mm thick as in plinth protection without using extra cement complete all as specified and directed.
Taking down cement plaster on brick walls or stone walls etc including raking out joint, hacking for key, scrubbing down with water etc including removing debris directed for a distance max upto 500m, complete all as specified and directed by Engr-in-Charge.
Material and Labour for rendering 15 mm thick on fair faces of brick/concrete surfaces cement plaster in CM (1:4) , finished even and smooth without using extra cement, complete all as specified and directed by Engr-in-Charge.
Material and Labour rendering 15mm thick on fair faces of brick work or concrete surfaces of walls in cement mortar 1:6 finished even and smooth (with out using extra cement), complete all as specified and directed by Engr-in-Charge.
Material and Labour for rendering 5mm thick in CM 1:3 on ceiling finished even and smooth including sagol finish , complete all as specified and directed by Engr-in-Charge.
Material and Labour for preparation of new or previously untreated plastered surfaces of walls and applying two coats of acrylic antifungal paint exterior grade paint plain or camouflage pattern on one coat of primer , complete all as specified and directed by Engr-in-Charge.
Material and Labour for preparing new plastered surfaces of walls and applying two coats of oil bound distemper over a coat of chalk whitening on plastered surfaces, complete all as specified and directed by Engr-in-Charge.
Material and Labour preparation of new plastered surface of ceiling and applying three coat of white wash on ceiling, complete all as specified and directed by Engr-in-Charge.
Demolition of pre-cast concrete block masonry built in cement mortar including all quoins, arches, pillars etc. and pre cast concrete articles , complete all as specified and directed by Engr-in-Charge.
Material and Labour for pre-cast cement concrete block masonry with solid blocks in 10cm in width in type B1 (1:2:4) and setting in mortar (1:6), complete all as specified and directed by Engr-in-Charge.
Supply and Fix rubber sponge gasket of 20mm thick and 40mm width fixed with and including approved adhesive, complete all as specified and directed by Engr-in-Charge.
Material and Labour for preparation of old wall surfaces of any description & applying one coat of acrylic (antifungal) exterior grade paint of camouflage pattern, complete all as specified and directed by Engr-in-Charge.
Material and Labour preparation of old plastered / decorated surfaces of walls and applying one coat of oil bound distemper on plastered/decorated wall surfaces including preparing surfaces with application of putty wherever required, complete all as specified and directed by Engr-in-Charge.
Supply and Fix for aluminium door/window/ventilator/partition, made out of extruded powder coated aluminium sections, with sliding or openable shutters including frame & necessary jointing cleats, glazing clips, powder coated aluminium snap beading, screws etc, complete and also including powder coated aluminium fittings such as cobra hinges, butt hinges, tower bolts, hooks & eyes, peg stays and handles including connected items, with and including making good to the disturbed portion with its original specifications, complete all as specified and directed by Engr-in-Charge.
Supply and Fix 4 mm thick sheet glass, ordinary quality ,fixed in aluminium Door /window shutter area not exceeding 0.50 Square Metre each pane, complete all as specified and directed by Engr-in-Charge.
Supply and Fix 4 mm thick sheet glass, ordinary quality ,fixed in aluminium Door /window shutter area . exceeding 0.50 Square Metre each pane , complete all as specified and directed by Engr-in-Charge.
Supply and Fix for concealed star lock powder coated for aluminium window fixed as per manufacturers instructions , complete all as specified and directed by Engr-in-Charge.
Supply and Fix aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair to aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specified and directed by Engr-in-Charge.
Supply and Fix 4 mm thick sheet glass, ordinary quality , glazing with oil putty or with wooden beads, area not exceeding 0.50 Square Metre each pane including hacking out old glass, complete all as specified and directed by Engr-in-Charge.
Supply and Fix 4 mm thick sheet glass, ordinary quality , glazing with oil putty or with wooden beads, area exceeding 0.50 Square Metre each pane including hacking out old glass , complete all as specified and directed by Engr-in-Charge.
Supply and Fix for rubber beading suitable for fixing 4mm / 5mm thick glass in aluminium window / doors etc, complete all as specified and directed by Engr-in-Charge.
Supply and Fix Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge.
PART - I : (b) E/M Works Taking down carefully copper /aluminium point wiring (light, fan socket or power) through stove enamelled steel conduit/pvc conduits including complete fittings such as switches, ceiling roses, pendants, regulators, sockets,, switch sockets, electrical fittings etc removing and making good disturbed surfaces of walls/ceiling etc, complete all as specified and directed by Engr-in-Charge.
Material and Labour for point wiring with 1.5 Sqmm single core, multi stranded copper conductor 1100 V grade, ISI marked , PVC insulated unsheathed cable (with approved colour code) FRLSH cable drawn in casing caping of 25 mm wide, with double locking type, ISI marked including all accessories casing caping as approved by Eng-in-charge, with PVC 1.5 mm multi stranded insulated unsheathed FRLSH copper wire, ISI marked of green colour for continuous earth, including sunken box made out of suitable thickness and not less than 60 mm in depth GI/MS/ pressed steel terminal box to be concealed in wall, duly painted including 3mm hylam /masonite sheet cover, for mounting of fittings like switches, sockets, fan regulators etc. fixed with galvanised screw and cup washer, complete all as specified and directed by Engr-in-Charge, for One light point or one fan point controlled by one switch. Note : Wiring to be done as per approved colour code.
-Ditto - all as per item No 67.00 here-in-before but One light point controlled by 2 way switch SP, 5 Amp, 240 Volts
-Ditto - all as per item No 67.00 here-in-before but one 5 amp socket point on same board
-Ditto - all as per item No 67.00 here-in-before but one 5 amp multi socket, independent
-Ditto - all as per item No 67.00 here-in-before but using 2.5 sqmm ( nominal area) multistranded FRLSH copper conductor cable/wire & 2.5 sqmm size PVC insulated unsheathed copper conductor cable for earth continuity ( green colour) for one 5 pin socket outlet 5 / 15 Amp multi purpose independent point controlled by 15 Amp switch, SP one way, 240 Volts & Socket, complete all as specified and directed by Engr-in-Charge.
-Ditto - all as per item No 67.00 here-in-before but using 4 sqmm (nominal area) FRLSH multistranded copper conductor cable/wire for one 5/15 Amp socket point controlled by 15 Amp switch, SP one way 240 Volts & Socket, complete all as specified and directed by Engr-in-Charge.
Supply and fixing switch piano type flush button type single pole one way 5 Amps 240V front operated, complete all as specified and directed by Engr-in-Charge.
Supply and Fix Switch socket combination 2 in 1 3 pin, 5 A and 15Amp flush type universal, complete all as specified and directed by Engr-in-Charge.
Supply and Fix socket 3 pin 5 A flush type, complete all as specified and directed by Engr-in-Charge.
Supply and Fix Bell buzzer 240V 50 Hz, complete all as specified and directed by Engr-in-Charge.
Supply and Fix Bell push 240V 50 Hz, complete all as specified and directed by Engr-in-Charge.
Supply and Fix ceiling rose PVC/polycarbonate, isolated body surface Bakelite 65mm dia three terminals, complete all as specified and directed by Engr-in-Charge.
Supply and Fix repair/replacement switch piano flush button single pole one way, 6 Amp (ISI marked) complete all as specified and directed by Engineer-in-Charge.
Supply and Fix in repair/replacement Switch socket outlet 2 in 1, 3 pin, 6 Amp flush type (ISI marked) complete all as specified and directed by Engineer-in-Charge.
Supply and Fix in repair/replacement Socket outlet 2 in 1, 3 pin, 6 Amp flush type (ISI marked) complete all as specified and directed by Engineer-in-Charge.
Supply and Fix in repair/replacement Switch bell push flush type 5 Amp (ISI marked) all as per complete all as specified and directed Engineer-in-Charge.
Supply and Fix in repair/replacement Switch socket combination outlet 15 Amp, 5-in-1, controlled by one switch (ISI marked) complete all as specified and directed by Engineer-in-Charge.
Supply and Fix in repair/replacement Switch flush button, single pole two way, 6 Amp (ISI marked) complete all as specified and directed by Engineer-in-Charge.
Supply and Fix in repair/replacement Socket type EME fan 5 step regulator switch/socket type for ceiling fan of suitable size, complete all as specified and directed by Engineer-in-Charge.
Supply and Fix in repair/replacement Lamp holder/angle holder insulated body with black/white plate for batten fittings, complete all as specified and directed by Engr-in-Charge.
Material and Labour for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 4.0 Sqmm (with colour code), drawn in but including non metallic rigid PVC conduit of 25mm dia/casing capping/ suitable size , ISI marked including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 4.0 Sqmm (Green colour) as continuous earth conductor cable connected to earth dolly in surfaces/ recess complete including taking down all as specified and directed by Engr-in-Charge.
Material and Labour for cutting of wall/ceiling/column for laying submain of any size including plastering ,white wash, complete all as specified and directed by Engr-in-Charge.
Supply and fixing repair/replacement LED building security light fitting with suitable size bracket/angle with three core flexible wire to fit security light of 45 W, IP 66 protection LED, complete all as specified and directed by Engr-in-Charge.
Supply and fix repair/replacement LED batten with 20/22W LED tube light in wall/surface connecting with all required accessories like PVC box base, flexible cable from ceiling rose etc Surface and wall mounted LED batten, Engineering plastic batten with accessories complete all as directed and specified by Engr-in-charge.
Supply and Fix double door MCB DB made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 100 Amps rated bus bar 12 way double door open able, including taking out old unserviceable MCB DB any size/type, complete all as specified and directed by Engr-in-Charge.
Supply and Fix double door MCB DB made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 100 Amps rated bus bar 8 way double door open able, including taking out old unserviceable MCB DB any size/type, complete all as specified and directed by Engr-in-Charge.
Supply and Fix double door MCB VTPN DB 4 Way made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 100 Amps rated bus bar 4 way ,including taking out old unserviceable MCB DB any size/type, complete all as specified and directed by Engr-in-Charge.
Supply and Fix double door MCB VTPN DB 8 Way made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 200 Amps rated bus bar 4 way ,including taking out old unserviceable MCB DB any size/type, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement 6 to 32 AMP MCB single pole 240 V 10 KA (C-Series), complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement SPN 32 AMP ,240 V 10 KA (C-Series) , complete all as specified and directed by Engr-in-Charge.
Supply and fix LED Bulk head fittings 9/10W luminaire including LED light driver holder 220 V, AC,50HZ connecting up with three core flexible copper conductor cable of suitable size complete with all accessories complete all as specified and directed by Engr-in-charge.
Supply and Fix in repair/replacement LED tube rod 20/22 watt, 220V,AC, 50Hz change with existing any tube rod including flexible wire and connected accessories , complete all as specified and directed by Engr-in-Charge.
Supply and Fixix in repair/replacement Batten MS suitable for 18/22/24W LED rod 220V,AC, 50Hz with accessories including suitable 1.5 sqmm 2 core wire for connecting with ceiling rose, complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair/replacement LED batten 10W, 2 feet with LED tube light 220V,AC,50HZ in wall/surface connecting with all required accessories like flexible cable from ceiling rose etc as directed and specified by Engr-in-charge.
Supply and Fix in repair/replacement MCCB 4 pole, thermal magnetic release range 100 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement MCCB 4 pole, thermal magnetic release range 125 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified and directed by Engr-in-Charge.
Material and Labour for daily complaint checking & repairing of DBs/meter panel board/circuits/submain wiring/switches/sockets etc and other connected work including rectification of faults , complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement MCCB 4 pole, thermal magnetic release range 63 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement MCCB 4 pole, thermal magnetic release range 40 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair/replacement PCRD plug of capacity 15 amp , AC, 220V, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement of old existing sunken/terminal box of size approx 10x10cm, concealed/surface mounted alongwith hylam sheet for fixing existing switches, sockets & regulators etc and making good disturbed surfaces of walls, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement of old existing sunken/terminal box of size approx 15x7.5cm, concealed/surface mounted alongwith hylam sheet for fixing existing switches, sockets & regulators etc and making good disturbed surfaces of walls, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement of old existing sunken/terminal box of size approx 20x15cm, concealed/surface mounted alongwith hylam sheet for fixing existing switches, sockets & regulators etc and making good disturbed surfaces of walls, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement of old existing sunken/terminal box of size approx 20x25cm, concealed/surface mounted alongwith hylam sheet for fixing existing switches, sockets & regulators etc and making good disturbed surfaces of walls , complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement emergency bulb LED 10W, 230V, 50Hz, with 2/4 hour backup, complete all as specified and directed by Engr-in-Charge.
Material and Labour for taking out and refixing of tube light, mirror light etc after cleaning and any type rectifying defect, complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair/replacement LED batten with 20W LED tube light (four feet) with inverter type with 2 hrs backup in wall/surface connecting with all required accessories like PVC box base, flexible cable from ceiling rose etc Surface and wall mounted LED batten, Engineering plastic batten with accessories complete all as directed and specified by Engr-in-charge.
Material and Labour for checking ceiling fan of size 1200/1400mm and change defective part quarter pin/ nut bolt , capacitor ,rewinding, bearing and minor items etc, complete all as specified and directed by Engr-in-Charge.
Material and Labour for earthing complete with GI earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below the normal ground level connected with GI strip 32 x 6 mm by means of bolts, nuts, check nuts & washers of galvanised iron steel including necessary excavation and earth work in any type of soil, removing surplus soil to a distance not exc 50 m, with and including PCC chamber in PCC (1:2:4) , type B1, using (20 mm graded stone aggregate), mild steel angle iron frame made out of MS angle iron of size 40x40x6 mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20 mm dia medium grade pipe for watering ,40 mm dia light grade GI pipe for lead protection in & including alternate layers of charcoal dust and common salt complete all as shown in electrical plate No 3 of SSR Part-1(2009) connected to earthing test point all as specified and indicated including testing on completion, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair GI strip 32mm x 6 mm saddle in wall for loop earthing and ground grid , complete all as specified and directed by Engr-in-Charge.
Supply and fix fan rod repair/replacement of size 1/1.5 feet suitable for mounting ceiling fan of size 1200/1400 mm, complete all as specified and directed by Engr-in-Charge.
Supply and fix repair/replacement flexible wire 1 sqmm x 2 core including taking out, complete all as specified and directed by Engr-in-Charge.
Supply & fixing, jointing, connecting & testing in saddle on wall 10 sqmm x 2 core, XLPE/PVC insulated PVC sheathed cable heavy duty 1100 volts grade, aluminium conductor in trenches / ducts/ of the following sizes including taking out cable cover & cable, complete all as specified and directed by Engr-in-Charge.
Supply & fixing in repairs/replacement air termination single pointed aluminium rod 12 mm dia and 300 mm long with necessary fixing arrangement on blocks on roof, complete all as specified and directed by Engr-in-Charge.
Supply & fixing in repairs/replacement air termination single pointed aluminium rod 12 mm dia and 1000 mm long with necessary fixing arrangement on blocks on roof, complete all as specified and directed by Engr-in-Charge.
Supply and Fix test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25 mm thick drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screws fixed to GI strip bracket fixed to porcelain insulator in wall as in repairs, complete all as specified and directed by Engr-in-Charge. Note :- Porcelain insulator will be measured & paid for separately.
Supply and Fix repair/replacement vitreous china porcelain insulator with busbar support white type, complete all as specified and directed by Engr-in-Charge.
Removing existing worn out CI cover with angle iron frame of earth chamber and supply and fix new CI cover of size 30 cm x 30 cm x 6 mm thick fixed in frame made out of mild steel angle iron 40 mm x 40 mm x 6 mm thick with and including locking and lifting arrangement, painting with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement 40 mm dia GI pipe medium grade for post not exceeding 3 metres in length truly vertical position embedded in PCC including not exc and earth work as in repairs, complete all as specified and directed by Engr-in-Charge. Note -: PCC of pole embedded will be measured and paid separately under relevant items of Sch.
Material and Labour for PCC (1:2: 4) type B0, using (12.5 mm graded stone aggregate) of blocks size and IE rules including necessary use and waste of form work as in grounting of porcelain insulator, complete all as specified and directed by Engr-in-Charge.
Material and Labour for PCC (1:2:4) type B1, using (20 mm graded stone aggregate) for earth chambers as in repairs, coping for GI pipe post including necessary form work, excavation in soft loose soil, returning in filling and removing surplus soil to a distance not exc 50 metre and deposing where directed, complete all as specified and directed by Engr-in-Charge.
Removing & refixing of air termination single pointed aluminium rod 12 mm dia and 300 mm long by tightening with necessary fixing arrangement fixed on existing/new PCC blocks on roof and making good complete all as specified and directed, complete all as specified and directed by Engr-in-Charge.
Material and Labour repair/replacement Submain wiring with two core 1100 volts 1.5 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through and including PVC conduit 20 mm dia with accessories like bend, junction box etc complete all as specified in and including 1.5 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuity conductor by using green colour to common earth and connecting to earth point and connecting to earth dolly, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement aluminium strip of size 25 x 3.15 mm fixed with suitable saddle, screw etc on roof with rubber & bitumen washer & fixed to insulator on wall for down conductor as fixed in repairs, complete all as specified and directed by Engr-in-Charge.
Re-fixing in repair only aluminium strip of size 20/25 mm x 3.15 mm fixed to porcelain insulator fixed with suitable saddle, screws etc for roof with rubber & bitumen washer & fixed to insulator only on wall for down conductor, complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair/replacement two way sheet metal enclosure with three pin socket and plug top and 20 amp single pole MCB, complete all as specified and directed by Engr-in-Charge.
PART - I : (c) AC Works Supply and fix in repairs cooling tower fan Assembly with fan speed not exceeding 60m/s, outlet air velocity not less than 610 m/min and noise level not exceeding 75 dBA made out of propeller type light weight solid/ hollow FRP rust resistant with statically and dynamically balanced blades alongwith galvanised steel guard protection to protect fan and out side area suitable for 61 to 120 TR capacity AC plants, complete all as specified and directed by Engr-in-Charge.
Supply and fix in repairs cooling tower fan Assembly with fan speed not exceeding 60m/s, outlet air velocity not less than 610 m/min with noise level not exceeding 75 dBA made out of propeller type light weight solid/ hollow FRP rust resistant with statically and dynamically balanced blades alongwith galvanised steel guard protection to protect fan and out side area suitable for upto 60 TR capacity AC plants, complete all as specified and directed by Engr-in-Charge.
Material and labour for taking out all old unserviceable PVC fills from cooling tower of capacity upto 100 TR and supply and fix in replacement of eliminator of cooling tower upto 100 TR, complete all as specified and directed by Engr-in-Charge.
Cleaning the cooling tower by applying wire brush, washing powder and other solvent by removing the deposited impurities such as silt, dust particles mud/ sand inside the dome and around the fins, cleaning of base tray & grills, pot stainer, main shaft etc and other connected items, servicing of fan motor including changing of bearings and greasing refixing the fan, frill & top cover including testing commissioning after reassembling complete including painting all as directed by Engr-in-charge
(a) cooling tower of capacity upto 35 TR
(b) cooling tower of capacity 66 TR to 250 TR
Supply and fix in repairs Sprinkler Assembly complete with Header Nozzles made out of Galvanised iron suitable to fix in cooling towers of upto 60 TR capacity AC plants, complete all as specified and directed by Engr-in-Charge.
Supply and fix in repairs Sprinkler Assembly complete with Header Nozzles made out of Galvanised iron suitable to fix in cooling towers of 61 TR and above Capacity AC plant, complete all as specified and directed by Engr-in-Charge.
Material and Labour for Charging of refrigerant gas R- 407C/ R134/R22 in sealed cylinder after making system leak proof, complete all as specified and directed by Engr-in-Charge. (Note:-Refrigerant shall be issued to contractor for each AC plant from AGE E/M -II store yard. Transportation as well as loading/unloading of cylinder from AGE E/M store yard to AC plant will be the responsibility of the contractor)
Supply and fixing of filter drier for chiller as per existing make and model , complete all as specified and directed by Engr-in-Charge.
Supply and Fix of supply / return / exhaust air grills /of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core, complete all as specified and directed by Engr-in-Charge.
Complete Servicing of AHUs installed in Zone-IV AC plants, removing of air filters and refixing after cleaning with air blower and water with suitable cleaning agent , cleaning of cooling coil with wire brush ,air blower and water spraying pump with gun and mixing the chemical sittable for removing of scales on aluminium fins and straighten the fins of cooling coil by using suitable brush for capacity upto 10000 CFM as directed by Engr-in-Charge.
Complete Servicing of AHUs installed in Zone-IV AC plants, removing of air filters and refixing after cleaning with air blower and water with suitable cleaning agent , cleaning of cooling coil with wire brush ,air blower and water spraying pump with gun and mixing the chemical sittable for removing of scales on aluminium fins and straighten the fins of cooling coil by using suitable brush for capacity 10000 CFM to 20000CFM as directed by Engr-in-Charge.
Material and Labour for repairs to condenser of AC plant by blocking the damaged/corroded tubes with the following instructions :- (i) Disconnecting the side covers of the condenser from their existing positions. (ii) Leakage testing of the condenser using pressurised nitrogen gas and finding the leaked tubes. (iii) Blocking the damaged/leaked tubes by brass plugs. (iv) Re-fixing the side covers of the condenser and the condenser valves from their existing positions with new nuts, bolts, rubber gasket and washers etc and painting the surface with approved shade of synthetic enamel paints for following capacities of condenser :-
(a) up to 35 TR Capacity
(b) 35TR and above capacity
Supply and fix regenerable coarse type, dust proof AHU air filter for following sizes:-
(a) AHU air filter of size 60cm x 60 cm x 5 cm
(b) AHU air filter of size 60cm x 50 cm x 5 cm
(c) AHU air filter of size 60cm x 40 cm x 5 cm
(d) AHU air filter of size 60cm x 30 cm x 5 cm
Dismantling and removing old unserviceable compressor sealed unit of Scroll Type Compressor carefully and supply, installation, testing new sealed Compressor unit of capacity 12.5 TR Model No SZ185S4RC of Make Blue Star/ Danfoss or equivalent complete with all standard accessories as per existing model installed at AC plant, complete all as specified and directed by Engr-in-Charge. Notes :- (i) Sealed unit shall be purchased from authorised dealers/agents (ii) Cost of labour for fixing and testing of leakage alongwith initial charging of suitable refrigerant and T&P shall be deemed to include in the quoted rate of this item. (iii) Unit rate quoted shall include for the necessary electrical check i.e. checking of panel wiring to run the compressor smoothly. (iv) Before opening/ dismantling of unserviceable compressor the refrigerant to be taken in empty cylinder as directed by Engr-in Charge.
Dismantling and removing old unserviceable compressor sealed unit of Scroll Type Compressor carefully and supply, installation, testing new sealed Compressor unit of capacity 5 to 10 TR as per existing model of Make Blue Star/ Danfoss or equivalent complete with all standard accessories as per existing model installed at AC plant, complete all as specified and directed by Engr-in-Charge. Notes:- (i) Sealed unit shall be purchased from authorised dealers/agents (ii) Cost of labour for fixing and testing of leakage alongwith initial charging of suitable refrigerant & T & P shall be deemed to include in the quoted rate of this item. (iii) Unit rate quoted shall include for the necessary electrical check i.e checking of panel wiring to run the compressor smoothly. (iv) Before opening/ dismantling of unserviceable compressor the refrigerant to be taken in empty cylinder as directed by Engr-in-Charge.
Dismantling and taking down defective parts of chiller/condenser pump set of capacity 7.5 to 10HP, replacement of defective parts like-bearing, bushes, impeller and shaft including lathe work and reassembling complete set including connecting and testing in presence of MES rep with entire satisfaction of Engr-in-Charge. Notes:- (i) bearing, bushes and impeller and shaft shall be measured and paid separately. (ii) Quoted rates are also deemed to be included for replacement of gaskets, packing with bearing grease, glands with graphite packing , nuts bolts , washers etc. (iii) Cost of transportation shall be deemed to be included in the rate quoted for these items. (iv) While taking out pump for repairs , the contractor will make arrangement plugging suction and discharge line with dead flanges, so that pumping of installation is not disturbed and there is no leakage of water.
Supply only in replacement the following spare parts for servicing and repairs of pump set under item No 148.00 here in before, complete all as specified and directed by Engr-in-Charge :-
Ball bearing suitable for 7.5 HP pump set
Ball bearing suitable for 10 HP pump set
Bronze impeller suitable for 7.5 HP pump set.
Bronze impeller suitable for 10 HP pump set.
Bronze bush suitable for 7.5 HP pump set
Bronze bush suitable for 10 HP pump set
Bronze shaft suitable for 7.5 HP pump set
Bronze shaft suitable for 10 HP pump set
Dismantling and taking down defective parts of chiller/condenser pump set of capacity 3 to 5 HP, replacement of defective parts like-bearing, bushes, impeller and shaft including lathe work and reassembling complete set including connecting and testing in presence of MES rep with entire satisfaction of Engr-in-Charge. Notes:- (i) bearing, bushes and impeller and shaft shall be measured and paid separately. (ii) Quoted rates are also deemed to be included for replacement of gaskets, packing with bearing grease, glands with graphite packing , nuts bolts, washers etc. (iii) Cost of transportation shall be deemed to be included in the rate quoted for these items. (iv) While taking out pump for repairs , the contractor will make arrangement plugging suction and discharge line with dead flanges, so that pumping of installation is not disturbed and there is no leakage of water.
Supply only in replacement the following spare parts for servicing and repairs of pump set under item No 150.00 here in before, complete all as specified and directed by Engr-in-Charge.
Ball bearing suitable for 3 HP pump set
Ball bearing suitable for 5 HP pump set
Bronze impeller suitable for 3 HP pump set.
Bronze impeller suitable for 5 HP pump set.
Bronze bush suitable for 3 HP pump set
Bronze bush suitable for 5 HP pump set
Bronze shaft suitable for 3 HP pump set
Bronze shaft suitable for 5 HP pump set
Material and Labour for painting of motor & pump for removing the existing deteriorated paint by scrapping the complete body along with complete foundation of Pump and Motor and filling the cavities with filter spray painting with Anti corrosive paint, two coats over a coat of red oxide zinc chrome and marking of SM/MES No. with black/white paint, complete all as specified and directed by Engr-in-Charge for following:-
(a) Capacity 7.5 HP and above
(b) Capacity below 7.5 HP
Material and Labour for rewinding of induction motor 900RPM, 3 phase, 50 Hz, 415 volt of compressor motor and AHU Blower , chiller , condenser motor comprising of the following activities for induction motor of following capacities complete all as specified and directed as per manufacturer's instructions. :- Notes :- (i) Any adjustment in the pump set if required. The same shall also be carried out by the contractor without any extra payment. (ii) Any damage to the pump set occurs due to improper installation of motor, contractor shall be liable for repair.
(a) Capacity 7.5 HP.
(b) Capacity 5 HP.
(c) Capacity upto 1 to 3 HP.
Dismantling electrically and mechanically electric motor any size, dismantling part, taking out unserviceable bearing capacity upto 15 HP including supply and replacement of new bearing, reassembling, reinstallation and testing complete all as specified and directed by Engr-in- Charge.
Dismantling electrically and mechanically electric motor of any size of AHU, taking out unserviceable Parts like-shaft, Impeler, bushes, fan blade, coupling and fan belt, replacement with new one, reassembling, reinstallation and testing the following size all as directed by Engr-in- Charge.
Supply only in replacement the following spare parts for servicing and repairs of AHU unit under item No 155.00 here in before, complete all as specified and directed by Engr-in-Charge :-
Bronze shaft suitable upto 60 TR AHU Unit
Fan belt suitable as per existing
Supply and Fix gland packing in 10/12.5 HP pump set, complete all as specified and directed by Engr-in-Charge.
Supply and Fix gland packing in 5/7.5 HP pump set, complete all as specified and directed by Engr-in-Charge.
Supply and Fix Water seal for upto 5 HP, complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement bimetal overload relay type MN-02 of relay range, 2.5 to 4.5 Amp with single phasing protection, complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement bimetal overload relay type MN-02 of relay range, 4.5 to 7.5 Amp with single phasing protection, complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement bimetal overload relay type MN-02 of relay range, 9 to 15 Amp with single phasing protection, complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement bimetal overload relay type MN-02 of relay range, 14 to 23 Amp with single phasing protection all as specified and directed by Engr-in-Charge.
Supply and fix in replacement Thermal overload relay type LRD 08 relay range, 4.00 to 7.50 Amp with single phasing protection, complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement electronic timer 800SQA, working voltage 240V 50 Hz , complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement Air break contactor Model No 3TS3500-0A with Auxiliary 3TX400--2A 1 NC 415 V, 50 Hz, AC , complete all as specified and directed by Engr-in-Charge.
Supply and fixing MCB SP 6 to 32 amp rating 240V, 10KA 'C' curve , complete all as specified and directed by Engr-in-Charge.
Supply and fixing MCB TP 40 to 63 AMP 415V 10KA 'C' curve , complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement MCCB 3 Pole, 415 V, fixed type, 25 to 100 Amps with breaking capacity 16 KA , complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement MCCB 3 Pole, 415 V, fixed type, 25 to 400 Amps with breaking capacity 36 KA , complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA , complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement MCCB 4 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement MCCB 4 Pole, 415 V, Adjustable type, 400 Amps with breaking capacity 36 KA, complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement power contactor 3 pole, type MNX 12, 1NO + 1 NC aux contracts with standard coil voltage 240 volts, rating 30 Amp of equivalent contactor of other makes as per site requirement in bluestar and voltas AC plants, complete all as specified and directed by Engr-in-Charge. (Make should be as per existing item)
Supply and fix in replacement power contactor 3 pole, type MNX 18, 1NO + 1 NC aux contracts with standard coil voltage 240 volts, rating 30 Amp of equivalent contactor of other makes as per site requirement in bluestar and voltas AC plants, complete all as specified and directed by Engr-in-Charge.(Make should be as per existing item)
Supply and fix in replacement power contactor 3 pole, type MNX 22 or 25 , 1NO + 1 NC aux contracts with standard coil voltage 240 volts, rating 30 Amp of equivalent contactor of other makes as per site requirement in bluestar and voltas AC plants, complete all as specified and directed by Engr-in-Charge. (Make should be as per existing item)
Supply and fix in replacement power contactor 3 pole, type MNX 32 , 1NO + 1 NC aux contracts with standard coil voltage 240 volts, rating 30 Amp of equivalent contactor of other makes as per site requirement in bluestar and voltas AC plants, complete all as specified and directed by Engr-in-Charge. (Make should be as per existing item)
Supply and fix in replacement power contactor 3 pole, type 1 NO/NC (Normal open/Normal Close) 65 Amps with standard coil voltage 415 volts, Chint's NC-1 6511 contactor of bluestar and voltas AC plants compressor unit of make M/s Chint's including taking down old unserviceable contactor, complete all as specified and directed by Engr-in-Charge. (Make should be as per existing item)
Supply and fix in replacement power contactor 3 pole, 18 Amps Power contactor Lc1D18M7 for CT fan motor of bluestar and voltas AC plants unit of make M/s Schneider including taking down old unserviceable contactor , complete all as specified and directed by Engr-in-Charge. (Make should be as per existing item)
Supply and fix in replacement power contactor 3 pole, 15 Amps Power contactor Lc1D15M7 for CT fan motor of bluestar and voltas AC plants unit of make M/s Schneider including taking down old unserviceable contactor , complete all as specified and directed by Engr-in-Charge. (Make should be as per existing item)
Supply, assembly and erection in repair of GI sheet with C & SS rectangular/square duct made out of 'L' shaped hollow profile, duly factory boxed, including all accessories such as corner, cleat, carriage bolt, gasket and appropriate sealant on longitudinal joint etc complete of size 24 gauge, complete all as specified and directed by Engr-in-Charge.
Material and Labour in repair for duct insulation with resin bonded fibre glass wool roll of density 24 Kg/Cum, with factory laminated aluminium vapour barrier, thickness of insulation 50 mm all as specified and including the following :- (a) Material and Labour for cleaning the duct surface (to be insulated) by scrapping carefully with wire brush etc. to make the surface completely free of mill scale, dirt, dust, grease and other foreign materials, taking special care so that all duct joints are sealed against any leakage. (b) Material and Labour for applying rubber based adhesive CPRX compound. (c) Material and Labour for sealing of all longitudinal joints and circular overlaps with and including aluminium foil tape 50 mm wide, to make the insulation leak proof. (d) Material and Labour for securing the insulation with and including mechanically fastened nylon / steel straps of size 12 mm / 50 mm at maximum intervals of 1.2 metre.
Material and Labour in repair for duct insulation with resin bonded fibre glass wool roll of density 24 Kg/Cum, with factory laminated aluminium vapour barrier, thickness of insulation 40 mm all as specified and including the following :- (a) Material and Labour for cleaning the duct surface (to be insulated) by scrapping carefully with wire brush etc. to make the surface completely free of mill scale, dirt, dust, grease and other foreign materials, taking special care so that all duct joints are sealed against any leakage. (b) Material and Labour for applying rubber based adhesive CPRX compound. (c) Material and Labour for sealing of all longitudinal joints and circular overlaps with and including aluminium foil tape 40 mm wide, to make the insulation leak proof. (d) Material and Labour for securing the insulation with and including mechanically fastened nylon / steel straps of size 12 mm / 40 mm at maximum intervals of 1.2 metre.
Supply and fix in replacement of thermostatic expansion valve of suitable capacity MVE size suitable for scroll type chiller units for keep a constant superheat or refrigerant level situation in refrigeration system based on evaporator outlet temperature and pressure. Brazing of the expansion valve is in the scope of the contractor in this item, all as specified and directed by Engr-in-Charge.
Material and Labour for descaling of complete condenser units Quarterly for central/ package type AC plants of following capacities by means of adding descaling chemical solution (HCL) or equivalent into the cooling tower sump as per requirements, and running the plant pump continuously till all the scale of pipes/shell are removed including removing side covers of condenser and cleaning the water tubes by means of nylon brushes till the scaling is removed and re fixing of covers including replacement of neoprene rubber gasket and refixing pipe connection etc. all as specified and directed to complete satisfaction of Engineer-in-charge
(a) condenser unit of AC plant up to 60 TR
(b) condenser unit of AC plant up to 120 TR
Supply and fix Microprocessor Scroll Controller for compressor of 12.5-40 TR Capacity including removing unserviceable of Microprocessor complete all as specified and directed. The Microprocessor should be as per the existing one and installed by the company authorised person duly calibrated and necessary wiring work also included in the quoted rate to the satisfaction of Engr-in-charge.
Supply and fix Microprocessor Scroll Controller for compressor of 41-80 TR Capacity including removing unserviceable of Microprocessor complete all as specified and directed. The Microprocessor should be as per the existing one and installed by the company authorised person duly calibrated and necessary wiring work also included in the quoted rate to the satisfaction of Engr-in-charge.
Supply and fix Micro controller system of Scroll compressor of 12.5-40 TR Capacity including removing unserviceable of Micro controller system complete all as specified and directed. The Micro controller system should be as per the existing one and installed by the company authorised person duly calibrated and necessary wiring work also included in the quoted rate to the satisfaction of Engr-in-charge.
Supply and fix in replacement of Single phase preventer type SPP VSP3 3 phase, 415 Volts, 50 Hz AC, complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of CVT for chiller controller power supply 3 phase, 415 Volts, 50 Hz AC, complete all as specified and directed by Engr-in-Charge.
Supply and fixing of connector in HVAC panel 6 Amp to 35 Amp, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement MS ERW tubing medium grade 80mm dia for condenser water circulation pipes, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement MS ERW tubing medium grade 100mm dia for condenser water circulation pipes, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement MS ERW tubing medium grade 65 mm dia for condenser water circulation pipes, complete all as specified and directed by Engr-in-Charge.
Material and Labour for Nitrogen leak test entire system of the AC plant of Cap upto 150 TR with Nitrogen gas. If found any leakage or reduction in the scale of pressure shall be located and arrest the leakage immediately by soldering or an appropriate measure are to be taken to stop the leakage permanently complete all as specified & directed by Engr-in-Charge.
Supply and Fix in replacement of butter fly valve of 50 mm dia, cast iron body, integrally molded close and body construction with hand lever, operated and rating of PN 10 with thermal insulation as per requirement of condenser and chilled water line, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement of butter fly valve of 65 mm dia, cast iron body, integrally molded close and body construction with hand lever, operated and rating of PN 10 with thermal insulation as per requirement of condenser and chilled water line , complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement of butter fly valve of 80 mm dia, cast iron body, integrally molded close and body construction with hand lever, operated and rating of PN 10 with thermal insulation as per requirement of condenser and chilled water line, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement of butter fly valve of 100 mm dia, cast iron body, integrally molded close and body construction with hand lever, operated and rating of PN 10 with thermal insulation as per requirement of condenser and chilled water line, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement of gun metal gate or globe valve of 15 mm dia with iron wheel head screwed both ends for iron pipes, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement of gun metal gate or globe valve of 25 mm dia with iron wheel head screwed both ends for iron pipes, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement of 15 mm dia ball brass valve , high pressure, with polythene float and fly nuts complete, screw for iron pipe or brass ferrule and mixed, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement of 25 mm dia ball brass valve , high pressure, with polythene float and fly nuts complete, screw for iron pipe or brass ferrule and mixed, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repairs of Chilled water sensor as per existing make and type, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repairs of pressure transducer sensor for LP and HP of the compressor unit as per existing make and type, complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of flow switch as per existing make and model, complete all as specified and directed by Engr-in-Charge.
Material and Labour in repairs Strip heater finned 2 inch wide aluminised steel fins of 415 volt 1.5 to 3 KW capacity to match with the existing, complete all as specified and directed by Engr-in-Charge.
Supply and fix in repairs pressure gauge of range -30-150, complete all as specified and directed by Engr-in-Charge.
Supply and fix in repairs pressure gauge of range 0-150 , complete all as specified and directed by Engr-in-Charge.
Supply and fix in repairs in repair on-off push button pendants with elements red/green/orange, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement V Belt, complete all as specified and directed by Engr-in-Charge of following sizes :-
(a) V Belt B-105
(b) V Belt A-26
(c) V Belt B-71
(d) V Belt B-78
(e) V Belt A-53
Dismantling/Taking down old unserviceable FRP body structure of cooling tower carefully and cleaning the sump with chemical and supply and fixing of new FRP sheets as per size existing at site including all fixing material such as m seal other water resistance adhesive and making the cooling tower structure leak proof, complete all as specified and directed by Engr-in-Charge.
Taking down old unserviceable insulation over the chiller pipe line, cleaning water pipe surface with steel brush removing dirt/dust, Material and labour for chilled pipe line insulation by applying a coat of zinc chromate primer & applying two coats of cold setting adhesive compound (CRPX) on pipes for sticking the insulation bonded mineral wool of density 144 Kg/cum, 50mm thickness tightly pressed on the pipe upto 250mm dia seal all the joint with adhesive compound warp the insulation surface by using one layer of polythene sheet 50mm wide PVC tape covering the entire surface with chicken mesh , of density 144 Kg/Cum and cover 26 gauge aluminium GI cladding of approved colour & cover with Glasswool complete all as specified and directed by Engr-in-Charge.
Supply and fix in repairs protection caps made out of GI Sheet of thickness 1.6 mm with three GI strip supports of size 25x3mm for fixing with the Cooling Tower including GI nuts & bolts for fixing, complete all as specified and directed by Engr-in-Charge.
Material and Labour for earthing complete with copper earth plate electrode of 60 cm x 60 cm x 3.15 mm size, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to copper strip of size 20 mm x 3 mm as earth lead, by means of bolts, buts, check nuts and washers of galvanised iron or steel, galvanized iron pipe of 40 mm diameter, connected to earthing test point, all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion and including excavation, earthwork, PCC earth pit of dimensions 550 mm X 550 mm (outer) and 300 mm X 300 mm (inner) and 250 mm deep, with a 10 mm thick CI cover, hinged to CI frame on ground level, GI watering pipe, funnel, etc. complete as specified and directed by the Enngr-in-Charge. Notes: (i) The cost of earth continuity conductor with GI pipe 40mm medium grade upto 7.5m is deemed to be included in respect of above item. (ii) The earth resistance value should not be more than 2 Ohm. (iii) Earth test report shall be submitted by contractor. If the earth resistance value is more than 2 Ohm new earthing will be done by contractor as replacement and no payment shall be mate for it. (iv) The earth chamber to be constructed 0.5m from edge of earth pit with necessary watering arrangement. The cost for the same is deemed to be included in above item
Material and Labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 20 x 3 mm copper strip complete as specified and directed by the Engr-in-Charge.
Supply and fixing of canvas housing suitable for existing connection AHU damper to Supply air Duct, complete all as specified and directed by Engr-in-Charge.
Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 KV for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m, complete all as specified and directed by Engr-in-Charge.
Supplying and fixing in repairs of fire dampers in supply air duct/ main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal as required, complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of wall mounting /hanging type LED digital type temperature /relative humidity indicator with 2" large size display and minimum size (445x130x115mm) with following specifications complete all as specified and as directed by Engr-in-charge :- Display : 2" Red LED x 2 Display, Accuracy : + 0.5%, Resolution : 0.1 deg C, 0.1 % RH, Input : 4-20mA, Enclosure : Powder coated metal case. Operating Voltage : 230V AC
Material and labour for laying, jointing, connecting and testing in repairs sensor cable 3 core 2.5 sqmm PVC insulated and sheathed with bare annealed copper conductor as per IS 694:1990 for connecting RH+T sensor to RH+T indicators complete all as specified and as directed by Engr-in-charge.
Material and labour for laying, jointing, connecting and testing in repairs indicator cable 2 core 1.5 sqmm PVC insulated and sheathed with bare annealed copper conductor complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of Thermal Insulation of Ducts with Nitrile Rubber, 25 mm thick with aluminium cladding, all as specified and as directed by Engr-in-charge. Density of Material shall be between 40 to 60 Kg/m3. Note :- Material shall have flammability class V-0 as per UL 94 and shall be FM Approved.
Material and Labour for replacement of unserviceable pot strainer 80/100mm including replacement of unserviceable rusted nut bolts, washers, & gasket complete all as specified and as directed by Engr-in-charge.
Material and Labour for spray painting to Central AC Plant complete, comprising of compressors, motors, condenser, cooling tower and cooling tower pumps, pump / monoblocks, MS / GI pipe lines of sizes etc after preparation of old painted surface as per colour code including and marking arrow, SM/ MES Nos, colour for upto 60 TR AC plant all as specified and as directed by Engr-in-charge.
Material and Labour for spray painting to Central AC Plant complete comprising of compressors, motors, condenser, cooling tower and cooling tower pumps, pump / monoblocks, MS / GI pipe lines of sizes etc after preparation of old painted surface as per colour code including and marking arrow, SM/ MES Nos, colour for upto 120 TR AC plant all as specified and as directed by Engr-in-charge.
Supply and Fix of Drift eliminator of cooling tower having capacity of 20TR to 85TR as per existing at site complete all as specified and as directed by Engr-in-charge.
Supply and Fix of Drift eliminator of cooling tower having capacity of 85TR and above as per existing at site complete all as specified and as directed by Engr-in-charge.
POWER CABLES - Material and Labour for ISI marked 1.1 kV grade aluminium conductor, XLPE insulated armoured cables, conforming to IS: 7098 (Part 1)- 1988 having stranded aluminium compact shaped conductor as per Cl. 2, IS: 8130- 1984, PVC inner sheath, single armouring of galvanized steel strip/wire and PVC Type ST2 outer sheath conforming to IS: 5831- 1984, including termination complete all as specified and as directed by Engr-in-charge.
(a) 3.5 Core 70 Sqmm
(b) 3.5 Core 35 Sqmm
(c) 4 core 25 Sqmm
(d) 3 core, 10 mm² (for Cooling Tower)
(e) 3 core, 6 mm²
(f) 2 core, 1.5 Sqmm ( for chillers interlocking)
Taking down and dismantling existing street Light/ Flood Light / post lantern / tube light fittings any type any wattage for repair or replacement of burnt /worn out accessories and refixed in position after repair all as specified and as directed by Engr-in-charge. Note :- (i) Accessories only wherever required shall be measured and paid separately as supply only. (ii) Labour charges for taking down and repair including minor spares like nuts, bolts , insulation materials & cleaning of area upto one metre around the street light/ building lights/ Poles shall be deemed to be included in the quoted rate .
Supply and fixing Pressure die cast aluminium housing LED street light luminaires with IP66 of 35/45/50 Watts all as specified and as directed by Engr-in-charge.
Supply and fixing Pressure die cast aluminium housing LED street light luminaires with IP66 of 90 Watts all as specified and as directed by Engr-in-charge.
Supply and fixing Pressure die cast aluminium housing LED street light luminaires with IP66 of 120 Watts all as specified and as directed by Engr-in-charge.
Supply and Fix LED floodlight luminaire with secondary optics made in pressure die cast housing and heat sink in aluminium extrusion with IP66, Turbo LED series ,120Watt & accessories and connecting up to looping box with PVC insulated multi stranded copper conductor cable 1.5 sqmm twin Core all as specified and as directed by Engr-in-charge.
Supply & Fix in repair bracket for street light fittings made out of 40 mm bore medium grade GI tubing 1.2 m long bent to shape and including suitable size of MS clamps, nuts, bolts and washers applying two coats of aluminium paint over a coat of red oxide zinc chrome primer repair complete all as specified and as directed by Engr-in-charge.
MAKE UP TANK : Supply and fix for PVC two mounting layered, closed lid cylindrical shapes ISI marked water tank of 5000 litres capacity mounted on suitable stage PCC 1:2:4 complete all as specified and as directed by Engr-in-charge. Note :- In case some parts required extensive repair and replacement , the same shall be done by contractor. Rates deemed to be included in quoted rate.
MAKE UP TANK : Supply and fix for PVC two mounting layered, closed lid cylindrical shapes ISI marked water tank of 10000 litres capacity mounted on suitable stage PCC 1:2:4 complete all as specified and as directed by Engr-in-charge. Note :- In case some parts required extensive repair and replacement , the same shall be done by contractor. Rates deemed to be included in quoted rate.
Supply only Rotational moulded polyethylene water storage tanks 500 litres capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified and directed by Engr-in-Charge.
Supply and Fix in repairs steel water tubing galvanised iron 25 mm dia medium grade with all fittings ISI marked including taking down old unserviceable GI pipe all as specified and directed by Engr-in-Charge.
Supply and Fix in repairs steel water tubing galvanised iron 40mm dia light grade with all fittings ISI marked including taking down old unserviceable GI pipe all as specified and directed by Engr-in-Charge. (item used for earthing only)
Supply and Fix in replacement of Non return single plate check valve designed for return flow prevention in pipeline installation of size 80 mm dia, cast iron body for water delivery line complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement of Non return single plate check valve designed for return flow prevention in pipeline installation of size 65 mm dia, cast iron body for water delivery line complete all as specified and directed by Engr-in-Charge.
PART - II : (a) Manning & Operation Outsourcing of services for Manning and operation of central AC plants by one skilled ref mech operator in each shift of 08 hrs i.e. Three (03) in a day for shifts i.e. 0600 Hrs to 1400 Hrs, 1400 Hrs to 2200 Hrs, 2200 Hrs to 0600 Hrs including Sunday & Holiday. The documentation of plant to be done by Ref Mech including maintaining Log Book. Routine maintenance including upkeep and cleanliness of other equipment like pump/motors, Cooling tower, AHU and surrounding area will be done by Ref Mech. The following AC plant equipments, accessories and control panel will be maintained as specified and as directed by Engr-in-charge. (a) Chilled water type central AC plant make Blue star of capacity 74 TR (02 working + 01 stand by) installed at EMR Workshop for maintaining Temp 22°C + 2°C and humidity 60 + 5%. (b) Chilled water type central AC plant make Blue star of capacity 20 TR (02 working + 01 stand by) installed at Bldg No 515 for maintaining Temp 23°C + 2°C and humidity 60 + 5%.
Outsourcing of services for Manning and operation of central AC plants by one skilled ref mech operator in each shift of 08 hrs i.e. Three (03) in a day for shifts i.e. 0600 Hrs to 1400 Hrs, 1400 Hrs to 2200 Hrs, 2200 Hrs to 0600 Hrs including Sunday & Holiday. The documentation of plant to be done by Ref Mech including maintaining Log Book. Routine maintenance including upkeep and cleanliness of other equipment like pump/motors, Cooling tower, AHU and surrounding area will be done by Ref Mech. The following AC plant equipments, accessories and control panel will be maintained as specified and as directed by Engr-in-charge. (a) Chilled water type central AC plant make Blue star of capacity 74 TR (02 working + 01 stand by) installed at RT Workshop for maintaining Temp 23°C + 2°C and humidity 60 + 5% (b) Chilled water type central AC plant make Blue star of capacity 72 TR (02 working + 01 stand by) installed at Bldg No 388 for maintaining Temp 23°C + 2°C and humidity 60 + 5%
Outsourcing of services for Manning and operation of central AC plants by one skilled ref mech operator in each shift of 08 hrs i.e. Three (03) in a day for shifts i.e. 0600 Hrs to 1400 Hrs, 1400 Hrs to 2200 Hrs, 2200 Hrs to 0600 Hrs including Sunday & Holiday. The documentation of plant to be done by Ref Mech including maintaining Log Book. Routine maintenance including upkeep and cleanliness of other equipment like pump/motors, Cooling tower, AHU and surrounding area will be done by Ref Mech. The following AC plant equipments, accessories and control panel will be maintained as specified and as directed by Engr-in-charge. (a) Chilled water type central AC plant make Voltas of capacity 240 TR (02 working + 01 stand by) installed at Harpoon Process Building for maintaining Temp 23°C + 2°C and humidity 65 + 5%
General notes for Item No 244.00 to 246.00 (a) Rate quoted by tenderer for the above items shall be deemed to be included for the expenditure of keeping general cleanliness of the area of the installations complete including cutting of grass shrubs & vegetations around the installations. (b) Protective clothing as per IS and safety instructions & tools required as applicable shall be provided by the contractor and shall be continuously in use of the operator on duty. No extra payment will be made to contractor for the same. (c) Printed log sheet shall be provided and maintained by the contractor properly as per the format approved by Eng-in-Charge duly signed by all concerned and no extra cost shall be admissible for this account. Log book shall be deposited with concerned JE every months and no payment will be made in absence of the same. (d) ITI qualified in Air Conditioning & Refrigeration or having minimum 5 years experience in operation and maintenance of Air Conditioning & Refrigeration plant shall be deployed by the contractor. Contractor shall arrange his man power in such a way that each employee should not be assigned more than one shift of 8 hours in a single day and weekly one day off is given to each employee for which separate manpower arrangement to be done by the contractor without any extra cost to the dept. (e) Any breakdown of AC Plant shall be reported immediately to JE E/M / Engr-in- Charge. (f) Life insurance of employed person shall be carried out by the contractor at his own cost from any insurance company approved by IRDA.
(g) Contractor will provide the uniform as recommended by Engr -in-Charge. The safety of equipment necessary T & P shall be maintained at all the installations. The contractor shall be fully responsible for safety of staff employed. Department will not be held responsible for any eventuality occurred to staff employed. The contractor will be responsible / liable to pay all type of compensation etc to employed staff in accordance with prevailing labour laws in country/ staff. (h) The tradesmen shall be well conversant with preventive measures (First Aid) in case of electrical accidents and fire fighting systems. (j) Carrying out operation of equipments, as a part of day to day operation and in accordance with relevant PM checklists and as per schedules that will be prepared upon activation of contract. The salient features in these checklists are as follows :- (i) Starting and stopping of the equipment as per requirement of the user. (ii) Checking the water level in the cooling tower (applicable for water cooled units) (iii) Recording the equipment operational parameter including pump pressure and motor amps in the log sheet. (iv) Checking the central AC or Refrigeration system and equipment such as compressors, motors, pumps, cooling towers and their electrical controls on the respective equipment. (v) Checking the refrigeration system for any leaks. (vi) Checking the electrical and refrigeration control system for operation and adjustments of set values as necessary. (k) Penalty of absence of any Ref Mech shall be Rs 2500/- per shift per day. (l) Tmp measurer shall be provided by contractor in respective installation in proper working condition. Rates quoted deemed to include the same.
Notes:- The quoted rate for above plants described at item No 244.00 to 246.00 here-in-before shall be deemed to be included the following:- (i) The operator shall be ITI holder with sufficient experience (not less than 05 years). The operator should be capable to rectify both mechanical as well as electrical defects for smooth functioning of AC plants. It is responsibility of contractor to provide a reliever to the operator. So that the operator is available all time. (ii) Man power list with aadhar linked bank account number, qualification certificate will be submitted prior to commencement of work for necessary sanction from GE. (iii) The contractor/ service providing agency shall be wholly and exclusively responsible for payment of wages of persons engaged by it in compliance with all the statutory obligations under all related legislations as applicable to it from time to time including Minimum Wages Act, ESI Act, EPF Act and the Department MES shall not incur any liability for any expenditure whatsoever on the persons employed by the contractor/ agency on account of any obligation. The contractor/ service providing agency will be required to provide particulars of group Insurance of employees engaged by him to the GE before processing of RAR payment. (iv) The contractor/ service providing agency will be required to provide two set of uniform to all operators with name and firm tag. (v) To carry out routine periodical checkups as directed by GE & Engr-in-Charge. (vi) Maintaining all the accessories such as electric panel, Interlocking wiring cables, pumps etc and all assemblies such as chillers etc and sub assemblies such as AHU, tower etc functional in any situation round the clock for the period including holidays etc. (vii) Maintaining the surrounding area of central AC plant building, cooling tower, etc neat & clean at all time. No wild vegetation to be seen with in the surrounding of building upto 5 metres all around (viii) Tools and plants such as spanners, wrench, screw driver, pliers, puller (Mechanically hydraulic) and alike items required for operation, sufficient running of the parts shall be arranged & are kept permanently with the staff (contractor's staff). However any major items which are required, as part of the installation shall arranged by the department.
pk Enterprises (BID ID -3394400)
sapana enterprises (BID ID -3397939)
DARSHAN CONSTRUCTION Co. (BID ID -3397196)
somnath engineering corporation (BID ID -3393435)
BRITE INDUSTRIES (BID ID -3395765)
cooltech engineering services (BID ID -3396323)
RADHA ENTERPRISE (BID ID -3394516)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .