| 1 | L1₹25.0 LAccepted-AOC NO 9 1ST FLOOR C J N HERITAGE PWD MAIN ROAD AKASH NAGAR B NARAYANAPURA DOORAVANI NAGAR BANGALORE 560016 | BANGALORE | BENGALURU URBAN | KARNATAKA | 560016 | L1 | Accepted-AOC L1 | |
| 2 | L2₹32.7 L+₹7.7 L (30.6%)Rejected-AOC NO S 7 2ND CROSS 2ND MAIN KEB LAYOUT SANJAYANAGAR BANGALORE 560094 | BENGALURU URBAN | KARNATAKA | 560094 | L2 | Rejected-AOC L2 | |
| 3 | L3₹38.1 L+₹13.1 L (52.1%)Rejected-AOC NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L3 | Rejected-AOC L3 | |
| 4 | L4₹39.6 L+₹14.6 L (58.1%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | Rejected-Technical | - | Rejected-Technical Unenlisted |
Tender Value
₹29.3 L
EMD Value
₹58,540
Closing Date
23 Apr 2022, 6:00 pmClosed
GE (AF) Yelahanka
GE (AF) Yelahanka Bangalore - 63
PROVISION OF HIGH-STATIC DUCTABLE SPLIT AIR CONDITIONER WITH CORDED REMOTE FOR STATION AUDITORIUM AT AFS YELAHANKA
2022_MES_513929_1
8946/E8
Open Tender
Civil Works
Item Rate
180 days
AFS Yelahanka
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) Yelahanka
₹58,540
Yes
24 Jan 2023
16 Mar 2022
25 Apr 2022
16 Mar 2022
23 Apr 2022
6 Apr 2022
Amount
Supply, installation, testing and commissioning of high static ductable split Air conditioner with corded remote, capacity 11.0 TR with R-407C/410A refrigerant, airflow not less than 7480 CMH, air cooled condensing unit, Harmetic scroll compressor 3 Phase (415 V), 50 Hz complete with indoor and outdoor units all as specified and directed by Engr-in-Charge Make : Voltas model No ACADS11012 or equivalent in Daikin/Blue Star Note : The MS cage will be measured and paid separately.
Supply, installation, testing and commissioning of high static ductable split air conditioner with corded remote, capacity 17.0 TR with R-407C/410A refrigerant, airflow not less than 11560 CMH, air cooled condensing unit, Harmetic scroll compressor 3 phase (415V), 50 Hz complete with indoor and outdoor units all as specified and directed by Engr-in-Charge. Make : Voltas model No ACADS11012 or equivalent in Daikin/Blue Star Note : The MS cage will be measured and paid separately.
Supply, installation, testing and commissioning of high static ductable split air conditioner with corded remote, capacity 5.5 TR with R-407C/410A refrigerant, airflow not less than 3740 CMH, air cooled condensing unit, Harmetic scroll compressor 3 Phase (415V), 50 Hz complete with indoor and outdoor units all as specified and directed by Engr-in-Charge. Make : Voltas model No ACADS11012 or equivalent in Daikin/Blue Star Note : The MS cage will be measured and paid separately.
Supply of refrigerant copper piping with nitrile rubber insulation for suction and discharge for 5.5 TR ductable unit complete all as specified and directed by Engr-in-Charge.
Supply and fixing of Hardrawn refrigerant copper piping with nitrile rubber insulation for suction and discharge for 11/17 TR ductable units complete all as specified and directed by Engr-in-Charge.
Supplying and fixing of CPVC drain pipes f size 32mm SDR 11 & Plain CPVC SDR 11 with necessary accessoriesto drain the condensation drain water from the drain tray to the nearest drain point complete all as specified and directed by Engr-in-charge.
Supply, installation, testing and commisioning of 6 core x 2.5 sqmm shielded copper communication cable for the communication from outdoor to indoor unit for ductable units complete all as specified and directed by Engr-in-Charge.
Supply and fixing of MS Fabricated stand to mount the outdoor with isolation rubber pads and one coat of primier and 1 coat of black paint for 11/17 TR ductable units complete all as specified and directed by Engr-in-Charge.
Supply and fixing of MS Fabricated stand to mount the outdoor with isolation rubber pads and one coat of primier and 1 coat of black Paint for 5.5 TR ductable unit complete all as specified and directed by Engr-in-Charge.
Supply of Refrigerant Gas R-32/R410A all as specifed and directed by Engr-in-Charge.
Supply , assembly and erection of GI sheet with C & SS rectangular/square duct made out of 'L' shaped hollow profile, duly factory boxed, incl all accessories such as Corner, Cleat, Carriage bolt, Gasket and appropriate sealant on longitudinal joints etc complete of following sizes complete all as specified and directed by Engr-in-Charge.
24 gauge galvanised sheet
22 gauge galvanised sheet
Supplying and instalation of Aucostic insulation 10mm open cell with tpe and adhesive complete all as specified and directed by Engr-in-Charge
Supply and Installation of thermal insulation on ducts with 9 mm thick Nitrile rubber with cotton tape and adhesive complete all as specified and directed by Engr-in-Charge.
Supply and installation of under Deck insulation for ductable split AC unit location (RB Glass wool + 26 Gauge aluminium perforated sheet+ Roofing Bolts) complete all as specified and directed by Engr-in-Charge including the following:- (a) M&L for cleaning the duct surface (to be insulated ) by scrapping carefully with wire brush etc. to make the surface completely free of millscale, dirt, dust, grease and other foreign materials, taking special care so that all duct joints are sealed against any leakage. (b) M&L for applying rubber based adhesive CPRX compound. (c) M&L for sealing of all longitudinal joints and circular overlaps with and including Aluminium foil tape 50 mm wide, to make the insulation leakproof. (d) M & L for securing the insulation with and including mechanically fastened nylon/ steel straps of size 12 mm/50 mm at maximum intervals of 1.2 mtr.
Supply & fixing of flexible connections constructed of fire resistant double between machine mouth to main duct canvas sleeve with zip provision complete all as specified and directed by Engr-in-Charge.
Supply and installation of GI Volume Control Dampers of GSS blades, channels, flanges for duct mounting, operationg handle etc complete all as specified and directed by Engr-in-Charge.
Supply & installation of fresh air arragnement with birdmesh, vcd & cowl complete all as specifed and directed by Engr-in-Charge.
Supply of Aluminum powder coated Supply Air Grill with Collar Damper Size:600X600mm complete all as specified and directed by Engr-in-Charge.
Suply of Aluminum powder coated Return Air Grill without Collar Damper Size: 600X600mm complete all as specified and directed by Engr-in-Charge.
Supply of 10" Flexible duct,Mixing Boxes & Butterfly Dampers with jubilee clamps complete all as specifed and directed by Engr-in-charge.
Air Balancing for Air Terminals of required CFM and all volume control dampers to acheieve the air flow of desired air volume at desired locations as per the client and the consultant.
Dismantling of ceiling boards(fibre, Pulp, insulation etc) or insulation boards/slabs thickness,including cover fillets and re fixed in same position on completion of job as on ceiling
Note: (a) The work will be carried out in Auditorium at the approx height of 9.00m (b) The system should be capable to maintaining inside conditioned air temperature 21±3 degree centigrade and RH 55%±5%. (c) The rate includes Necessary core cutting and tarpaulin between AC duct and evaporator unit
UNIVERSAL ENGINEERING
devan enterprises
SREE VARU ELECTRICALS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .