Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.0 LAccepted-AOC 12 1 FERRIGHAT ROAD P O BHATPARA DIST NORTH 24 PGS WEST BENGAL PIN 743123 | BHATPARA | NORTH 24 PARGANAS | WEST BENGAL | 743123 | L1 | Accepted-AOC L1 |
Tender Value
Refer Docs
EMD Value
₹8,030
Closing Date
27 Nov 2024, 11:00 amClosed
AE HCESD PWD
Office of the AE HCESD PWD, Calcutta High Court
Replacement of damaged parts,devices incl. dismantling, refixing, recommissioning and restoration of the existing Fire detection system at different buildings of Honble High Court, Calcutta.
2024_WBPWD_766971_1
WBPWD/AE/HCESD/NIQ-103/23-243r
Open Tender
FIRE FIGHTING M/R
Item Rate
15 days
High Court Calcutta
Please refer Tender documents.
5 documents required · 5 mandatory
₹8,030
16 Jan 2025
5 Nov 2024
29 Nov 2024
12 Nov 2024
27 Nov 2024
18 Nov 2024
Amount
Supply , Installation, Testing and commissioning of Multi sensor Detector with base[VDS/LPCB approved under EN listed/standards or UL/FM approved under NFPA listed/standards] as per IS:-2189 of latest ammendment with in-built optical smoke-sensor with backward & forward scattering light angles as well as additional heat detector sensors with decentalized intelligence and all necessary accessories suitable for/matching with existing Fire Alarm panel with as rqequired. (Make: Securiton model no.- MCD 573X, FZ:324391 or equivalent model of Autronica/Siemens as approved by E.I.C)
Supply, installation, testing & commissioning of (VDS/LPCB approved under EN listed/standards or UL/FM approved under NFPA listed/standards) Inteliigent addressable manual call point complete with all accessories as per IS-2189 of latest ammendment and suitable for/matching with existing Fire Alarm panel (Make- Securiton model -MCP 545X-N or equivalent model of Autronica/Siemens as approved by E.I.C)
Supply, Installation, Testing & Commissioning of (VDS/LPCB approved under EN listed/standards or UL/FM approved under NFPA listed/standards) Addressable Loop Sounder cum Strobe complete with all accessories as per IS-2189 of latest ammendment and suitable for/matching with existing Fire Alarm panel (Make: Securiton MODEL -BX-SOL-R or equivalent model of Autronica/Siemens as approved by E.I.C)
Supply & Installation of Response Indicator with all necessary accessories suitable for/maching with existing Fire Alarm panel [VDS/LPCB approved under EN listed/standards or UL/FM approved under NFPA listed/standards]. (Make-Securiton/Autronica/Siemens)
Supplying & laying of 2x1.5 sqmm FRLS shielded copper Conductor stranded cables in red/black color and generally confirming to IS-694-2010 and meet the signal cabling requirements (Make-Havells/Finolex/Polycab/Gloster/KEI as approved by E.I.C)
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] of following sizes on wall, ceiling with saddles and other accessories as required and mending good damages to building works [E-16/7(a)]
Charges for checking, testing, rectification & re-commissioning of existing Fire Detection system (Securiton make) at all floors (Multi Sensor Detectors, manual call point, Response Indicator, monitor devices etc & other fire detection system equipments) under panels of Main building, Centenary building, Annex Building and Judge's Library Building different control devices of existing fire Control panel and making integration of all devices of Fire Detection system [existing (make of Securiton) & additional] with existing fire Control panel with proper checking & functioning of existing loops of the said Panels.
Add. G.S.T.@ 18% on total value.
Add. LWC.@ 1% on total value
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .