Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.8 LAccepted-AOC HYDERABAD TELANGANA 500076 INDIA UDYAM TS 02 0009467 | MEDCHAL MALKAJGIRI | TELANGANA | 500076 | L1 | Accepted-AOC Being L1. | |
| 2 | L2₹12.2 L+₹1.3 L (12.1%)Rejected-Finance 50 SARASWATI VIHAR SINGHAWALA AMBALA CITY | AMBALA CITY | L2 | Rejected-Finance Being not L1. | |
| 3 | L3₹14.0 L+₹3.1 L (28.9%)Rejected-Finance | L3 | Rejected-Finance Being not L1. | |
| 4 | Rejected-Technical | - | Rejected-Technical Not enlisted in appropriate category i.e. b(ii) | |
| 5 | Rejected-Technical | - | Rejected-Technical Not enlisted in appropriate category i.e. b(ii) |
Tender Value
₹18.7 L
EMD Value
₹37,400
Closing Date
20 Jan 2021, 6:00 pmClosed
GE
GE (AF) MC CHANDIGARH
Repair/maint to DG sets/standby system and other misc electrical equipments at 3BRD AF Station Chandigarh under GE (AF) MC Chandigarh
2020_MES_406243_1
GE(AF) MC CHD-35/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
CHANDIGARH
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE (AF) MC CHANDIGARH
₹37,400
Yes
CHANDIGARH
9 Mar 2021
23 Dec 2020
22 Jan 2021
23 Dec 2020
20 Jan 2021
6 Jan 2021
24 Dec 2020 - 29 Dec 2020
30 Dec 2020
Amount
Material and labour for servicing to DG sets 10 KVA to 50 KVA capacity by replacing following spare parts. The servicing should be carried out by representative of Original Equipment Manufacturer to the entire satisfaction of Engr-in-charge. ( a) Fuel Filter (Primary & Secondary) - 01 Set, ( b) Oil Filter - 01 Set, (c) Air filter - 01 No (d) Engine Oil and Coolant - As per capcity of DG Set Note : Rate of the Spare parts and Engine oil deemed to be included in quoted rate.
Material and labour for servicing to DG sets 62.5 KVA to 82.5 KVA capacity by replacing following spare parts. The servicing should be carriedout by representative of Original Equipment Manufacturer to the entire satisfaction of Engr-in-charge. (a) Fuel Filter (Primary & Secondaroy) - 01 Set, (b) Oil Filter - 01 Set, ( c) Air filter - 01 No (d) Engine Oil and Coolant - As per capcity of DG Set. Note : Rate of the Spare parts and Engine oil deemed to be included in quoted rate.
Material and labour for servicing to DG sets 100 KVA to 125 KVA capacity by replacing following spare parts. The servicing should be carried out by representative of Original Equipment Manufacturer to the entire satisfaction of Engr-in-charge. (a) Fuel Filter (Primary & Secondaroy) - 01 Set, (b) Oil Filter - 01 Set, (c) Air filter - 01 No ( d) Engine Oil and Coolant - As per capcity of DG Set. Note : Rate of the Spare parts and Engine oil deemed to be included in quoted rate.
Material and labour for servicing to DG sets 160 KVA capacity by replacing following spare parts. The servicing should be carried out by representative of Original Equipment Manufacturer to the entire satisfaction of Engr-in-charge. (a) Fuel Filter (Primary & Secondaroy) - 01 Set, (b) Oil Filter - 01 Set, (c) Air filter - 01 No (d) Engine Oil and Coolant - As per capcity of DG Set. Note : Rate of the Spare parts and Engine oil deemed to be included in quoted rate.
Material and labour for servicing to DG sets 200 KVA capacity by replacing following spare parts. The servicing should be carried out by representative of Original Equipment Manufacturer to the entire satisfaction of Engr-in-charge. (a) Fuel Filter (Primary & Secondaroy) - 01 Set, (b) Oil Filter - 01 Set, (c) Air filter - 01 No (d) Engine Oil and Coolant - As per capcity of DG Set. Note : Rate of the Spare parts and Engine oil deemed to be included in quoted rate.
Material and labour for servicing to DG sets 250 KVA capacity by replacing following spare parts. The servicing should be carried out by representative of Original Equipment Manufacturer to the entire satisfaction of Engr-in-charge. ( a) Fuel Filter (Primary & Secondaroy) - 01 Set, ( b) Oil Filter - 01 Set, ( c) Air filter - 01 No ( d) Engine Oil and Coolant - As per capcity of DG Set. Note : Rate of the Spare parts and Engine oil deemed to be included in quoted rate.
Material and labour for servicing to DG sets 320 KVA capacity by replacing following spare parts. The servicing should be carried out by representative's of Original Equipment Manufacturer to the entire satisfaction of Engr-in-charge. ( a) Fuel Filter (Primary & Secondaroy) - 01 Set, (b) Oil Filter - 01 Set, (c) Air filter - 01 No d) Engine Oil and Coolant - As per capcity of DG Set. Note : Rate of the Spare parts and Engine oil deemed to be included in quoted rate.
Material and labour for servicing to DG sets 500 KVA to 625 KVA capacity by replacing following spare parts. The servicing should be carried out by representative's of Original Equipment Manufacturer to the entire satisfaction of Engr-in-charge. (a) Fuel Filter (Primary & Secondaroy) - 01 Set, (b) Oil Filter - 01 Set, (c) Air filter - 01 No (d) Engine Oil and Coolant - As per capcity of DG Set. Note : Rate of the Spare parts and Engine oil deemed to be included in quoted rate.
Material and labour for top up lubrication oil Viscosity No SAE 15W/40 for DG sets of capacity 10 KVA to 625 KVA at different locations for top up of the Engine tank complete all as specified and directed. MAKE : Servo /Castrol/Veedol
Supply and fixing in replacement of battery 12 volts 150 AH with 25 Nos plates complete all as directed. Make; Exide - (Little Champ) FLCO-EXLC150R , TATA GREEN - 150G51CV, LUMINOUS - IG 1500
Supply and fixing in replacement of battery 12 volts 180 AH plates comple all as directed. Make; Exide - (Little Champ) FLCO-EXLC180R , TATA GREEN - 180H52CV, LUMINOUS - IL22000
Supply and fixing in replacement of Auto Voltage Regulator suitable for 50 KVA to 160 KVA , 415 V AC as per existing make and pattern complete all as specified and directed. Make: Kirloskar/Stamford/Ashok Lyland
Supply and fixing in repalacement of Auto Voltage Regulator suitable for 200 KVA to 625 KVA , 415 V AC as per existing make and pattern complete all as specified and directed. Make: Kirloskar/Stamford/Ashok Lyland
Material and labour in repair of self starter 12 volts duly rewinding of armature and replacement of unservicable spare parts etc DG Sets capacity from 10KVA to 100KVA DG set including testing complete all as specified and directed.
Material and labour in repair of self starter 24 volts duly rewinding of armature and replacement of unservicable spare parts etc DG Sets capacity from 125KVA to 625KVA DG set ncluding testing complete all as specified and directed.
Material and labour in repair of battery charger including rewinding of transformer and replacement of rectifier,toggle switches,voltmeter, ammeter & MCB etc of capacity 12 volts complete all as specified and directed.
Material and labour in repair of battery charger including rewinding of transformer and replacement of rectifier,toggle switches,voltmeter, ammeter & MCB etc of capacity 24 volts complete all as specified and directed.
Supply and fixing in repair of battery charger including copper wound transformer, rectifier, toggle switches, voltmeter, AM meter & MCB etc of capacity 12 volts complete all as specified and directed.
Supply and fixing in replacement of battery lead copper of 50 sqmm as per sample ( Red and Black colour ) battery lead all as specified and directed.
Supply and fixing in replacement of heavy duty battery terminal positive marking /negetaive marking of brass of existing size battery terminal complete all as specified and directed.
Material and labour for top up coolent for DG sets complete all as specified and directed. Make: CASTROL - RADICOOL HEAVY DUTY COOLANT or Equivalent of SERVO , VEEDOL
Supply and fixing in replacement of MCCB 4 pole 160 Amps with adjustable type 36 KA breaking capacity complete all as specified and directed. Make Schneider Cat Part No LV430780 or equivalent make of Hager/ABB/Legrand/Havells
Supply and fixing in replacement of MCCB 4 pole 250 Amps with adjustable type 36 KA breaking capacity MCCB all as specified and directed. Make Schneider Cat Part No LV431780 or equivalent make of Hager/ABB/Legrand/Havells
Supply and fixing in replacement of MCCB 4 pole 400 Amps with adjustable type, 36 KA breaking capacity complete all as specified and directed. Make Schneider Cat Part No LV432677 or equivalent make of Hager/ABB/Legrand/Havells
Supply and fixing in replacement of MCCB 4 pole 630 Amps with adjustable type,50 KA breaking capacity complete all as specified and directed. Make Schneider Cat Part No LV432677 or equivalent make of Hager/ABB/Legrand/Havells
Supply and fixing in replacement of off load Change over switch 4 pole of capacity 400 Amps, AC, 50 Hz, 415 volts with sheet steel enclosure out door type all as directed. Make:Cat No IHCFFE0400 of HAVELLS or equivalent C & S ,Legrand
Supply and fixing in replacement of off load Change over switch 4 pole of capacity 630 Amps, AC, 50 Hz, 415 volts with sheet steel enclosure out door type all as directed. Make: Cat No IHCFFE0630 of HAVELLS or equivalent C & S,Legrand
Supply and fixing in replacement of Dynamo Assy from 125 KVA DG Set to its original position complete all as directed.
Supply and fixing in replacement of Dynamo Assy from 30 KVA DG Set to its original position complete all as directed.
M&L for preparation of new steel surface and applying one coat of red oxide primer with two coat of synthetic enamel paint on surfaces of any description, over 10cm in width or girth, not otherwise described complete all as specified and directed.
Supply and fixing in replacement of radiator from the 200/250 KVA DG Set including connected hose pipe etc and cleaning thoroughly all the tubes and fins etc and carrying out copper brazzing to stop the leakage of the cooling tubes complete all as directed.
Supply and Fixing in replacement of self starter 12 Volts complete all as directed. Make : Audolek or Equivalent
Supply and Fixing in replacement of self starter 24 Volts complete all as directed. Make : Audolek or Equivalent
Supply and fixing in repalacement of Three Phase Ems 926 Controller suitable for 10 KVA to 30 KVA as per existing make and pattern complete all as directed. Make: Kirloskar or as approved by GE.
Supply and fixing in repalacement of Ems 907 Controller suitable for 200 KVA to 250 KVA as per existing make and pattern complete all as directed. Make: Kirloskar or equivalent as approved by GE.
Supply and fixing in repalacement of Under Voltage Relay 415V AC for control Panel as per existing make and pattern complete all as directed. Make: Teknika or equivalent as approved by GE.
Supply and fixing in repalacement of Tripping coil ACB 240 V AC complete all as directed. Make: Siemens or equivalent as approved by GE.
Supply and fixing in repalacement of Contactor 4 Pole 400 Amp 440 volt complete all as directed. Make: Schneider or equivalent as approved by GE.
Supply and fixing in repalacement of ACB Closing coil 200 V to 250 V complete all as directed. Make: Schneider or equivalent as approved by GE.
Supply and fixing in repalacement of under voltage release type mv coil 220 V and 415 V complete all as specified and directed. Make: L&T
Supply and fixing in repalacement of Brass oil pressure sensor complete all as directed. Make: Cummins or equivalent as approved by GE.
Supply and fixing in repalacement of Three Phase Kg 934 V2 controller complete all as directed. Make: Kirloskar or equivalent as approved by GE.
Supply and fixing in repalacement of Panel mounting Timer on-delay, 5Amp complete all as directed. Make: Mistura or equivalent as approved by GE.
ELECTRICAL ITEMS
Disconnecting of HT connections and DC connections from existing bus bar and disconnecting trolley including servicing of complete parts of VCB, cleaning with carbon tetra chloride, lubrication of mechanical parts, adjustment and calibration of complete relays etc and checking complete parts, repairs to control wiring with single core PVC insulated copper conductors of existing size as required at site of VCB of make Crompton Greaves/Megawin of capacity up to 630 Amp for satisfactory running and replacement of defective spare parts inlcuidng wiring, other connected parts and reassembling the same re-connecting all HT & AC / DC connections complete in functional order including testing on existing load complete all as specified and directed. Note :- 1. Spare parts shall be measured and paid for separately under respective items of this schedule as supply only. These shall be identical to those specified by original manufacturer and small parts such as nuts, bolts, screws & washers required at site are deemed to be included in the cost quoted by the contractor. 2. Calibration to be done by OEM or his authorised rep. Test report will be provided after test with warranty.
Supply only spring charging motor AC /DC of VCB trolley as per existing sample complete all as directed. Make:- DELCO/ Electra.
Supply only motor cut off switch for spring charging motor of VCB trolley as per existing sample complete all as directed.
Supply only current transformer moulded in epoxy compound with dual ratio 80/40/1/1 Amps or 100/50/5/5 Amps or 200 / 100/ 5 /5 Amps as per existing sample complete including connection with copper wire 2.5 Sqmm and beading as per existing VCB at site complete all as directed. Make:- AE/Crompton Greaves/AREVA T&D/English Electric.
Supply only HRC fuse base with HRC fuse 20Amp suitable for PT, 415 V, 80 KA complete all as directed. Make : L&T/Scheneider/Legrand
Supply only multifunction meter for 11 KV VCB as per existing sample complete all as directed. Make :- Scheneider Model Conzerv M 6459 or equivalent L&T, Legrand
Supply only indicator lamps as per existing colour code for 11 KV VCB & RMUs complete all as directed. Make :- L&T/AE/Secure /Scheneider
Supply only spring charging Gear assembly of VCB trolley as per existing sample complete all as directed.
Supply only shunt tripping coil 24V DC of VCB trolley as per existing sample complete all as directed.
Supply only closing coil 24 V DC of VCB trolley as per existing sample complete all as directed.
Supply only power pack with input 220-110V AC and output 24V DC of VCB as per existing sample complete all as directed. Make:- Mahamai/Alan/Gogate Electric system.
Supply only plug & socket assembly as per existing sample of VCB trolley complete all as directed.
Supply only resin encapsulated vacuum interrupter bottles of the same specification as per existing sample of circuit breaker trolley of 11 KV VCB complete all as directed. Make : ABB/Scheneider/Crompton Greaves/Siemens/ITL.
Supply only control wiring 1.5 sqmm FRLS PVC insulated copper conductor for control circuits and 2.5 sqmm FRLS PVC insulated copper conductor for CT circuits as per existing diagram including provided cable ties, beading etc of VCB or RMU complete all as directed. Make of wire:- FINOLEX / L & T / RPG / POLYCAB / GRANDLAY/Anchor
Supply only 11 KV/110 Volt 3 phase 3 limb 3 wire resin cast, drawout type, air cooled, potential transformer having 100 VA output at CL-0.5 and Rail complete all as directed.
Supply only aluminium thimble of size upto 50 sqmm complete all as directed. Make: Dowells/Jainson
Supply only aluminium thimble of size 70 sqmm to 150 sqmm complete all as directed. Make: Dowells/Jainson
Supply only aluminium thimble of size 185 sqmm to 240 sqmm complete all as directed. Make: Dowells/Jainson
Supply only aluminium thimble of size 300 sqmm to 400 sqmm complete all as directed. Make: Dowells/Jainson
Supply only aluminium thimble heavy duty long neck of size 95 sqmm to 120 sqmm complete all as directed. Make: Dowells/Jainson
Supply only aluminium thimble heavy duty long neck of size 150 sqmm to 185 sqmm complete all as directed. Make: Dowells/Jainson
Supply only HT bituminous tape suitable for 11 KV of size 0.6mm thick 20mm wide and 3.3 mtr length complete all as directed. Make: M Seal/Incab
Supply only coton empire tape suitable for 11 KV of size 20mm wide and 5 Mtr in length complete all as directed. Make: M Seal/Incab
Supply only LT PVC self adhesive electrical insulation tape of size W-30mm x L-15 Mtr x T- 0.125 mm ISI marked for cable insulation complete all as directed. Make : Anchor/PCG
Supply and fix in replacement of ACB 4pole, 415 Volt with thermal magnetic release (manual fixed type) of capacity 630 Amps as per existing size and make complete all as directed. Make : ABB/Legrand/C&S
Supply and fix in replacement of ACB 4pole, 415 Volt with thermal magnetic release (manual draw out type) of capacity 630 Amps as per existing size and make all as directed. Make : ABB/Legrand/C&S
Supply and fix in replacement of MCCB 4 pole 200 Amps with adjustable thermal magnetic release 35 KA breaking capacity complete all as directed. Make : Schenider cat part No LV431641 or equivalent ABB/Legrand/ Havell's/Indo Asian
Supply and fix in replacement of MCCB 4 pole 250 Amps with adjustable thermal magnetic release 35 KA breaking capacity complete all as directed. Make :Schenider cat part No LV431640 or equivalent ABB/Legrand/ Havell's/Indo Asian
Supply and fix in replacement of MCCB 4 pole 400 Amps with adjustable thermal magnetic release 35 KA breaking capacity complete all as directed. Make :Schenider cat part No LV431640 or equivalent ABB/Legrand/ Havell's/Indo Asian
R N Enterprises
M/S BALWINDER SINGH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .