Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.2 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹41.5 L+₹5.2 L (14.5%)Rejected-Finance B 134 GANESH MURTHI NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹43.5 L+₹7.2 L (20.0%)Rejected-Finance 47 HUSENI LAKDA BAZAAR 242 BELLAIS ROAD MUMBAI 08 | MUMBAI | MUMBAI | MAHARASHTRA | 400008 | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹44.9 L+₹8.7 L (23.9%)Rejected-Finance B 101 SURAJ TOWER MIRA BHAYANDER ROAD OPP SAI PETROL PUMP MIRA ROAD EAST THANE 401107 | MIRA ROAD EAST | THANE | MAHARASHTRA | 401107 | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹50.8 L+₹14.6 L (40.3%)Rejected-Finance A 14 USHA SADAN NEAR POST OFFICE COLABA MUMBAI 05 | MUMBAI | MUMBAI | MAHARASHTRA | 400005 | L5 | Rejected-Finance Being other than lowest |
Tender Value
Refer Docs
EMD Value
₹95,920
Closing Date
28 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NW NAVY NAGAR COLABA MUMBAI
GE NW NAVY NAGAR COLABA MUMBAI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI
REPAIR MAINTENANCE TO EXTERNAL WATER SUPPLY AND ALLIED WORKS AT RS AREA UNDER GE NW NAVY NAGAR COLABA MUMBAI
2024_MES_640236_1
8332/E8
Open Tender
Civil Works - Water Works
Item Rate
270 days
GE NW NAVY NAGAR COLABA MUMBAI
Class D and Category a(ii)
8 documents required · 8 mandatory
₹500
GE NW NAVY NAGAR COLABA MUMBAI
₹95,920
Yes
19 Mar 2024
1 Feb 2024
29 Feb 2024
1 Feb 2024
28 Feb 2024
15 Feb 2024
1 Feb 2024 - 21 Feb 2024
Amount
Supply and fix in repairs cast iron pipes with spigot and socket centrifugally cast class `LA' in any length laid in trenches including nut, bolts, washer, gasket, welding work etc of following sizes.
300mm bore
250 mm bore
200 mm bore
150 mm bore
100 mm bore
80mm bore
Supply and fix in repairs DI pipes with spigot and socket centrifugally cast class `K-9' in any length laid in trenches including nut, bolts, washers, rubber gasket, flanges, welding works etc of following sizes.
350 mm bore
300 mm bore
200 mm bore
150mm bore
100mm bore
80 mm bore
M & L for CI specials confirming to IS - 1538, spigot /socket or flanged fitting I.e. bend, tee, collar, flanged/ socket /spigot, Tappers and tails pieces etc suitable for 80/100/150/200/250/300 mm bore pipes (joints and joining material shall be measured and paid seperately)
M & L for DI specials confirming to IS - 1538, spigot /socket or flanged fitting I.e. bend, tee, collar, flanged/ socket /spigot, Tappers and tails pieces etc suitable for 100/150/200/250/300/350 mm bore pipes (joints and joining material shall be measured and paid seperately)
M & L for run lead joint in repair with pig lead including pumping out / bail out water and necessary excavation and earth work in any type of soil,to repair the joints for following sizes of pipes :-
300 mm bore
250 mm bore
200 mm bore
150 mm bore
100 mm bore
80 mm bore
M & L for Cutting existing DI pipes and reducing for insertion of DI fittings to required length in position for following sizes :-
350 mm bore
300 mm bore
200 mm bore
150 mm bore
100 mm bore
80 mm bore
M & L for Cutting existing cast iron pipes and reducing for insertion of CI fittings to required length in position for following sizes :-
300 mm bore
250 mm bore
200 mm bore
150 mm bore
100 mm bore
80 mm bore
Excavation in trenches not exceeding 1.5 mtr wide not exceeding 1.5 mtr in depth and getting out in soft/ loose soil all as specified.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cms in any type of soil all as specified. Note : For item No 8.00 and 9.00 above rate deemed to be included for earth work and form work required as per site requirement & as directed by Engineer-in-Charge.
Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15 cm thickness (below or above ground level) and debris out side MD land all as specified.
M&L cement concrete 1:2:4, type B-2 (using 40 mm graded stone aggregate) as in support of CI pipes, foundation and hardstanding finishing even and fair without using extra cement all as specified.
Removing excavated material to a distance exc 250m but n.exc 500m and depositing where directed all as specified.
S&F in repair sluice valves flanged end, cast iron body, flanged and drilled and non rising type brass spindle with nut, long body, class P N 1.6, confirming to IS 14846 of 2000 for following sizes including all flange joint with rubber or fiber board, bolts, nuts, washers welding works complete including pumping out accumulated water all as specified and directed of following size.
300 mm bore
250 mm bore
200 mm bore
150 mm bore
100 mm bore
80 mm bore
Taking down/Removing old plasters, broken bricks, PCC , MS Chanel, MS Plate & debries inside the valve chamber in repair/maintenance of existing brick masonry valve chamber of size 1.2 x 1.2 x 1.2m (internal dimension) (above GL 0.30 mtr) , 15cm thick foundation using PCC 1:4:8 type D-2 over 15cm thick hardcore of broken stone, 23cm thick brick walls built in cement and sand mortar 1:4, 15mm thick internal and external plaster including top of floor in cement and sand mortar 1:3, 15mm thick, finished even and smooth, without using extra cement, 5 mm thick MS plate cover over complete chamber on 50mm x 50mm x 6mm MS angle frame embeded in PCC 1:2:4 type B-1coping, having rectangular, hinged, opening of size 150 x 100mm with locking arrangements ,hold fasts, etc, applying one coat of red oxide primer and two coats of synthetic enamel paint to all steel surfaces and earth work in any type of soil including disposal of debris outside MD land complete all as specified. Note :- Rates for removing of old plasters, broken stones/bricks, PCC of any type, earth work, M S Chanel, MS Plate e.t.c are deemed to be inclueded in the quoted rated.
Attending the water supply breakdowns of any size/type of pipes in any position/location/depth including necessary excavation, earth work, cutting of pipes, welding, replacement of pipes of any nature, flanges, bends, collars, nut bolts, gasket, run lead joint or any other items required for rectification of break downs, testing and making good to the disturbed surfaces after rectification complete all as specified and directed for the following size of pipe lines :- Note :- (a). Items like run lead joint, CI/DI /MS fittings or pipes, nut bolts shall be measured and paid separately under relevant item of schedule 'A (b). Remaining items are shall be deemed to be included in the item rate and no extra payment shall not to be claimed for the completion of break down. (c). After hand over of complaint, contractor shall complete the break down within 24 hrs or other wise panel recovery shall be made 2500/- per breakdown
(a) 350/300 mm dia CI/DI/MS pipe line
(b) 250/200 mm dia CI/DI/MS pipe line
(c) 150/100 mm dia CI/DI/MS/GI pipe line
(d) 80 mm dia CI/DI/MS/GI pipe line
Supply and fixing in repairs, Installing,Testing and Commissioning of Ultrasonic Level Transmitter Range : 0-5 metres Accuracy : 0.5 % minimum 34. Supply Voltage : 24V DC Output : 4-20 mA Ultrasonic Frequency:75 kHz burst, rep. rate 96 ms Delay at Power-up: 1.5 seconds Temperature Effect: Uncompensated: 0.2% of distance/°C &Compensated: 0.02% of distance/°C Delay at Power-up: 1.5 seconds Resolution: 1.0 mm Output Response Time: 100 ms to 2300 ms Minimum Window Size: 20 mm Environmental Rating: Leakproof design is rated IEC IP67; NEMA 6P Operating Conditions: Temperature: –20 °C to 70 °C (–4 °F to 158 °F) Maximum relative humidity: 100% Note :- Core cutting on sump/tank as required at site shall be deemed to be item rate. Make : Endress/ Hauser/ Banner/ Krohnc/ Marshal/ Siemens
Material and labour for bacteriological and chemical analysis of water sample at govt approved lab (Iso 9001:2008)including collecting sample from pumphouse using labed owned sample jar and testing every month all directed and specfied by Engineer-in-charge. (Note : Before claiming payment, the contractor has to submit the test report)
Supply and fixing in repairs, Installation Testing & Commissioning of direct acting type release solenoid valve for air release during priming; with follwing specifications : Size: 10 mm, Pressure rating: 10 kg / sq. cm. Type: Normally closed
Supply/ Fixing in repair/replacement of steel water tubing, galvanised, Medium grade with all fittings in shafts such as nipple, union, socket, elbow, bends, fixed to wall including necessary & capacity up to 15 th floor in high rise buildings in short piece/length, including breaking the existing brick wall for replacement of corroded GI pipe in/on wall and making good the disturbed surfaces complete all as specified and directed by Engineer-in-charge.Note (1)Work to be carried out in high rise buildings plain wall or in shafts or in terraces or inside the flats for cutting the existing GI pipe line and replace the same with new GI pipe in short piece of full length.
25 mm bore
40 mm bore
50 mm bore
80 mm bore
Taking down GI tubing fixed to wall at location cleaning and refixing the same with clamping on wall including necessary fitting in high rise building (G+14 stories) for the following :-
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
Supply and fix in repairs in existing line, gun metal gate valve with iron wheel head screwed both ends for iron pipe including fittings i.e. union, socket etc complete all as specified of following sizes :-
25 mm bore
40 mm bore
50 mm bore
80 mm bore
Taking out existing unserviceabe lid cover of PVC water storage tank and supply/Fixing FRP lid cover on existing PVC tank including complete accessories for closing and locking arrangement as per BMC Specification. Suitable for :
5000 Ltrs PVC tank
3000 Ltrs PVC tank
2000 Ltrs PVC tank
1000 Ltrs PVC tank
S& F Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, of size Fe 410-W(GdeE- 250) quality A including dismantling of old one and all as specified and directed by Engineer-in-Charge.
S&F PVC water storage Tank three layer hoisting and fixing in position at any location removing existing distmantling RCC/PCC OHT and new foundation making as well as disconnecting all incoming & out going connection , provision of new tank fittings & connecting it at existing position up to 50 mm GI Pipe connection complete all as specified and directed.
5000 Ltr capacity
3000 Ltrs capacity
2000 Ltr capacity
1000 Ltr Capacity
Supply and fix in repair, Installation, Testing & Commissioning of Motor Actuated Butterfly Valve consisiting of Quarter turn single phase Actuator and Wafer type butterfly valve of size 300 mm dia with appropriate bracket/mounting arrangement including two nos. limit switches for open and closed condition and splash proof enclosure. Specifications & Features Input Voltage: 230 V, A.C. Designed line pressure: 10 kg/sq cm. Operating Angle: 90 degrees Disc Material: CI with nylon coating Limit Switches : 02 Nos.For open and close status Mounting :Extended type with universal joint for installation 18 -24 inches above ground level with angle mounting including raising of existing chamber if required. Make: EMTORK / HASEL HOFENER / RITETORK /SIEMENS/ HONEY WELL
Supply and fix in repair, Installation, Testing & Commissioning of Motor Actuated Butterfly Valve consisiting of Quarter turn single phase Actuator and Wafer type butterfly valve of size 200mm dia with appropriate bracket/mounting arrangement including two nos. limit switches for open and closed condition and splash proof enclosure. Specifications & Features Input Voltage: 230 V, A.C. Designed line pressure: 10 kg/sq cm. Operating Angle: 90 degrees. Disc Material: CI with nylon coating Limit Switches : 02 Nos.For open and close status Mounting : Extended type with universal joint for installation 18 -24 inches above ground level with angle mounting including raising of existing chamber if required. Make: EMTORK / HASEL HOFENER / RITETORK /SIEMENS/ HONEY WELL
Supply and fix in repair, Installation Testing & Commissioning of Motor Actuated Butterfly Valve consisiting of Quarter turn single phase Actuator and Wafer type butterfly valve of size 150 mm dia with appropriate bracket/mounting arrangement including two nos. limit switches for open and closed condition and splash proof enclosure. Specifications & Features Input Voltage: 230 V, A.C. Designed line pressure: 10 kg/sq cm. Operating Angle: 90 degrees Disc Material: CI with nylon coating Limit Switches : 02 Nos.For open and close status Mounting :Extended type with universal joint for installation 18 -24 inches above ground level with angle mounting including raising of existing chamber if required. Make: EMTORK / HASEL HOFENER / RITETORK /SIEMENS/ HONEY WELL
Supply and fix in repair, Installation, Testing & Commissioning of Motor Actuated Butterfly Valve consisiting of Quarter turn single phase Actuator and Wafer type butterfly valve of size 100 mm dia with appropriate bracket/mounting arrangement including two nos. limit switches for open and closed condition and splash proof enclosure. Specifications & Features Input Voltage: 230 V, A.C. Designed line pressure: 10 kg/sq cm. Operating Angle: 90 degrees Disc Material: CI with nylon coating Limit Switches : 02 Nos.For open and close status Mounting ::Extended type with universal joint for installation 18 -24 inches above ground level with angle mounting including raising of existing chamber if required. Make: EMTORK / HASEL HOFENER / RITETORK /SIEMENS/ HONEY WELL
Supply and fix in repair , Installation, Testing & Commissioning of Motor Actuated Butterfly Valve consisiting of Quarter turn single phase Actuator and Wafer type butterfly valve of size 80 mm dia with appropriate bracket/mounting arrangement including two nos. limit switches for open and closed condition and splash proof enclosure. Specifications & Features Input Voltage: 230 V, A.C. Designed line pressure: 10 kg/sq cm. Operating Angle: 90 degrees Disc Material: CI with nylon coating Limit Switches : 02 Nos.For open and close status Mounting :Direct mounted Make: EMTORK / HASEL HOFENER / RITETORK /SIEMENS/ HONEY WELL
Supply and fix in repair, laying in repair, 6 core 1.5 sqmm armoured cable with copper conductor.
Supply and fix in repair, laying in repair, 4 core 1.5 sqmm armoured cable with copper conductor.
Supply and fix in repair foot valve threaded type or flanged type in existing location or new position or location in the sump of any capacity including making of flanged joints , nut bolts washers rubber gasket welding work flange joints etc and repair making good to existing PCC surface of following sizes :-
80 mm bore
150 mm bore
200 mm bore
250 mm bore
300 mm bore
Supply and fix in repair of Non return valve confirming to IS 5312-1(2004) including nut, bolts, washer, flanges, gaskets, wleding works etc of the following sizes :-
300 mm dia
250 mm dia
200 mm dia
150 mm dia
100 mm dia
Material and labour for rubber gasket joint of following sizes complete all as specified and directed
300 mm bore
250mm bore
200 mm bore
150 mm bore
100 mm bore
Supply and fix in repairs MS Pipe confirming to IS 1239 Part-I (2004) including nut, bolts, washer, flanges, gaskets, wleding works etc equivalent to BS 1387/1985 of following dia incl applying one coat of red oxide primer and two coats of synthetic enamel paint of colour required at site.
300 mm bore (Minimum wall thickness 6.35 mm)
200 mm bore (Minimum wall thickness 6.350 mm)
150 mm bore (Minimum wall thickness 4.78 mm)
100 mm bore (Minimum wall thickness 3.96 mm)
80 mm bore (Minimum wall thickness 3.05 mm)
Scrapping of paint complete pump and motor, base frame and accessories complete including making new synthetic enamel paint of two coats over a coat of red oxide primer of motor of capacity 15 HP to 75 HP complete all as specified and directed.
Rubbing with emery papers for removing of rusting material on fire fighting Pipe lines , fittings, motors, pumps, cabinet boxes, valve chamber covers, fire brigades and other items relating to complete fire fighting system in buildings up to (G+15 floors), cleaning and painting with two coats red colour synthetic enamel paint over a coat of red oxide primer complete all as specified and directed
SHRI SAI ENTERPRISES
Unity Enterprises
Saviour Security Systems
S S ENTERPRISES
Shetty Construction Co
Shree Ayyappa Engineering
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .