OFFICE OF THE EXECUTIVE ENGINEER STD DODA
OFFICE OF THE EXECUTIVE ENGINEER STD DODA
Additional Works to be carried out under the approved work of augmentation of transformer capacity from 6.30 MVA to 10MVA at Receiving station Mandal and 3.15 MVA to 6.30 MVA at receiving station Bheli-Ghat
2021_PDD_133237_1
STD/Doda/Capex 21-22/13 of 2021
Open Tender
Electrical Works
Turn-key
45 days
DODA
KINDLY REFER TO SBD
2 documents required · 2 mandatory
₹500
THE EXECUTIVE ENGINEER STD DODA
₹16,000
21 Oct 2021
5 Aug 2021
18 Sept 2021
5 Aug 2021
16 Sept 2021
5 Aug 2021
5 Aug 2021 - 7 Aug 2021
BOQ 1 Supply,Installation Testing and commissioning of electrical equipments for replacement of damaged/dysfunctioning equipment,up gradation of switchgear protection system at 6.30 MVA Receivinjg Station Bheli Ghat.
11 kV Indoor Heat Shrinkable Cable Termination Kits 300 Sqmm,three core
11 kV Outdoor Heat Shrinkable Cable Termination Kits 300 Sqmm,three core
11 kV Indoor Heat Shrinkable Cable Termination Kits 240 Sqmm,three core
11 kV Outdoor Heat Shrinkable Cable Termination Kits 240 Sqmm,three core
11 KV link Sets Heavy Duty 50x6 mm suitable for Dog Conductor(set of 3 limbs)
11 kV VCB Panel Board outgoing (12 kV, 1250A, 25 kA, with O/C, E/F relays (IEC61850), Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps, DLMS Compliant with RS-485 port (Easun Reyrolle make) to replace the existing dysfunctional panel
33 KV Post insulators
30 V tripping coils to replace the existing damaged coils
MIT 103 Relay
33 KV Isolator with Earthing Blade
Improvement of outdoor switch yard of 2x10 MVA Receiving Station Mandal Kishtwar by way providing and renovation of damaged busbar of switch yard/outgoing structures.
33 KV disc insulators(Polymer type)
200mm sq ACSR Panther Conductor only labour charges (available at site)
33 KV Post insulators
T-clamps
Single tension panther fittings
Red oxide Paint
Al. Paint
Nuts and bolts (Galvanised )
Electrification of control room at Receiving station Mandal , Kishtwar.(All the material should be of Anchor/Havells make)
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sqmm FRLS PVC insulated copper wire single core cable in surface/recessed medium class PVC Conduit with modular switch modular plate, suitable GI box and earthing the point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable etc as required
Wiring for light/power plug with 2x4 sqmm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No 4 sqmm FRLS PVC insulated copper conductor single core cable for loop earthing as required .
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper comductor,single core cable in surface/recessed medium class PVC conduit as required 2x2.5 Sqmm+1x2.5sqmm earth wire
Supplying and fixing of following sizes of medium class PVC Conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required 40mm
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 &15/16 amps modular socket and 15/16 amps modular switch ,connection etc as required
Supply and fixing following modular switch/socket on the existing modular plate and switch box including connections but excluding modular plate etc as required
5/6 amp switch
3 pin 5/6 amp socket outlet
Blanking Plate
Fan regulator
Supplying and fixing following way horizental type three pole and neutral sheet stel MCB distribution board 415 volts on surface/recess complete with tinned copper bus bar ,neutral bus bar.earth bar,din bar, interconnections,power painted including earthing etc as required (But without MCB/RCCB/Isolator). 6 way (4+8), Double door
Supplying and fixing 5 amps to 32 amps rating 240/415 volts "C" curve miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections testing and commisioning etc as required.
Single pole
Single Pole and Neutral
Supplying and fixing of following rating 240 volts "C" Series miniature circuit breaker suitable for lighting and other loads of following poles in the esixting MCB DB complete with connections testing and commissioning
Single Pole and Neutral 63 Amp.
Supplying and fixing of 10 watt LED batten fitting for Mirror Light Including connections etc as required
Supplying and fixing of surface mounted 20/22 watt LED batten fitting 4 feet Long including connections etc as required Light Including connections etc as required
Supply and fixing of Angle/Batten Holder polycarbonate including making complete connections etc as required along with providing and fixing of 15 watt LED Bulbs
Supplying and fixing of 10 watt LED bulb head light for outdoor use fitting complete with the suitable sizes accessories including connections etc. as required
Supplying and fixing of following electrical items suitable for operating on 240/230 Volts AC,50HZ including comnnections etc as required.
Miscellaneous items
Ceiling fan 1200mm sweep (5 star rating ) sweep preferred make Crompton Greaves Smart Breeze model or equivalent Model of Havells, Orient ,Usha.
16 Sq mm Aluminium 2 core cable
BOQ 2 Civil Work at Receiving station Mandal
33 KV yard metalling
Surface dressing of ground removal of inadequate vegetation.
Note- Rate quoted above in BOQ 1 include the cost of civil works where ever required. No extra bill be accepted
power control system
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .