| 1 | L1₹36.1 CrAdmitted-Finance KUSHAL BAG RAJ RAJESHWARI COLONY BANSWARA 327001 RAJASTHAN | BANSWARA | BANSWARA | RAJASTHAN | 327001 | ₹36.1 Cr | L1 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Bharti Construction Company L1 |
|---|---|---|---|---|
| 1.00 | Cutting and clearance of jungle, bushes, shrubs Ankra/Ipomoea, Juliflora typna etc. on canal and bunds in dry/moist/slushy conditions including disposal as per instructions of the Engineer-in-charge. Cost of wood has been deducted from rates and thus will be property of contractor after cutting. Ordinary | 6,51,254 | Sqm | 1.34 ₹8.7 L |
| 2.00 | Cutting and clearance of jungle, bushes, shrubs Ankra/Ipomoea, Juliflora typna etc. on canal and bunds in dry/moist/slushy conditions including disposal as per instructions of the Engineer-in-charge. Cost of wood has been deducted from rates and thus will be property of contractor after cutting. Thick | 8,91,032 | Sqm | 2.3 ₹20.5 L |
| 3.00 | Cutting and uprooting of trees including removing of roots and filling of hole, cutting/up rooted would be property of the department Over 15 cms to 30 cms. girth | 26 | Each | 116.21 ₹3,021.46 |
| 4.00 | Cutting and uprooting of trees including removing of roots and filling of hole, cutting/up rooted would be property of the department Over30 cms to 45 cms. girth | 54 | Each | 195.52 ₹10,558.08 |
| 5.00 | Cutting and uprooting of trees including removing of roots and filling of hole, cutting/up rooted would be property of the department Over 60 cms. girth | 137 | Each | 472.22 ₹64,694.14 |
| 6.00 | Removal of slit/soil/earth, sand, pebbles, Malba , debris, rubbish, stone pebbles and obstruction deposited in canal bed up to design line grade and sections having design due to erosion/scour/slips in canal banks/silting with or without bushes and weeds etc. in dry or moist condition from canal bed including dewatering, loading unloading and disposal at suitable place as directed by Engineer in charge with initial lead of 50m. and lift upto 1.5 m with proper dressing on canal bed complete in all respect For depth above 30cm. | 600 | Cum | 83 ₹49,800 |
| 7.00 | Removal of slit/soil/earth, sand, pebbles, Malba , debris, rubbish, stone pebbles and obstruction deposited in canal bed up to design line grade and sections having design due to erosion/scour/slips in canal banks/silting with or without bushes and weeds etc. in dry or moist condition from canal bed including dewatering, loading unloading and disposal at suitable place as directed by Engineer in charge with initial lead of 50m. and lift upto 1.5 m with proper dressing on canal bed complete in all respect Extra on item 7(c) only if silt clearance is done under water and mud. | 360 | Cum | 21.22 ₹7,639.20 |
| 8.00 | Excavation including loading, unloading, disposal and dressing of excavated earth within initial lead of 50m and lift up to 1.5m including dressing of excavated area and dewatering wherever required complete in all respect Hard / dense soil | 93,688.25 | Cum | 87.61 ₹82.1 L |
| 9.00 | Excavation including loading, unloading, disposal and dressing of excavated earth within initial lead of 50m and lift up to 1.5m including dressing of excavated area and dewatering wherever required complete in all respect Hard soil mixed with Kankar / boulders, Morrum | 53,097.09 | Cum | 109.77 ₹58.3 L |
| 10.00 | Excavation including loading unloading disposal and dressing of excavated rock within initial lead of 50m and lift upto 1.5m in dry or moist including dressing of excavated area, de-watering wherever required complete in all respect. Soft / Disintegrated rock | 15,154.49 | Cum | 148.49 ₹22.5 L |
Tender Value
₹39.1 Cr
EMD Value
₹78.3 L
Closing Date
9 Oct 2023, 6:00 pmClosed
ACE Water Resources Zone Udaipur
ACE Water Resources Zone Udaipur
Rehabilitation of Badgaon Medium Irrigation Sub-Project District Chittorgarh- RWSLIP
2023_WRDAS_367420_1
ACE NIT NO 30/2023-24 (1)
Open Tender
Civil Works
1095 days
chittorgarh
Please refer Tender documents.
4 documents required · 4 mandatory
₹10,000
XEN WRD Chittorgarh
₹78.3 L
Yes
Udaipur
18 Dec 2023
16 Sept 2023
10 Oct 2023
18 Sept 2023
9 Oct 2023
18 Sept 2023
29 Sept 2023
Amount
Cutting and clearance of jungle, bushes, shrubs Ankra/Ipomoea, Juliflora typna etc. on canal and bunds in dry/moist/slushy conditions including disposal as per instructions of the Engineer-in-charge. Cost of wood has been deducted from rates and thus will be property of contractor after cutting. Ordinary
Cutting and clearance of jungle, bushes, shrubs Ankra/Ipomoea, Juliflora typna etc. on canal and bunds in dry/moist/slushy conditions including disposal as per instructions of the Engineer-in-charge. Cost of wood has been deducted from rates and thus will be property of contractor after cutting. Thick
Cutting and uprooting of trees including removing of roots and filling of hole, cutting/up rooted would be property of the department Over 15 cms to 30 cms. girth
Cutting and uprooting of trees including removing of roots and filling of hole, cutting/up rooted would be property of the department Over30 cms to 45 cms. girth
Cutting and uprooting of trees including removing of roots and filling of hole, cutting/up rooted would be property of the department Over 60 cms. girth
Removal of slit/soil/earth, sand, pebbles, Malba , debris, rubbish, stone pebbles and obstruction deposited in canal bed up to design line grade and sections having design due to erosion/scour/slips in canal banks/silting with or without bushes and weeds etc. in dry or moist condition from canal bed including dewatering, loading unloading and disposal at suitable place as directed by Engineer in charge with initial lead of 50m. and lift upto 1.5 m with proper dressing on canal bed complete in all respect For depth above 30cm.
Removal of slit/soil/earth, sand, pebbles, Malba , debris, rubbish, stone pebbles and obstruction deposited in canal bed up to design line grade and sections having design due to erosion/scour/slips in canal banks/silting with or without bushes and weeds etc. in dry or moist condition from canal bed including dewatering, loading unloading and disposal at suitable place as directed by Engineer in charge with initial lead of 50m. and lift upto 1.5 m with proper dressing on canal bed complete in all respect Extra on item 7(c) only if silt clearance is done under water and mud.
Excavation including loading, unloading, disposal and dressing of excavated earth within initial lead of 50m and lift up to 1.5m including dressing of excavated area and dewatering wherever required complete in all respect Hard / dense soil
Excavation including loading, unloading, disposal and dressing of excavated earth within initial lead of 50m and lift up to 1.5m including dressing of excavated area and dewatering wherever required complete in all respect Hard soil mixed with Kankar / boulders, Morrum
Excavation including loading unloading disposal and dressing of excavated rock within initial lead of 50m and lift upto 1.5m in dry or moist including dressing of excavated area, de-watering wherever required complete in all respect. Soft / Disintegrated rock
Excavation including loading unloading disposal and dressing of excavated rock within initial lead of 50m and lift upto 1.5m in dry or moist including dressing of excavated area, de-watering wherever required complete in all respect.Hard rock not requiring blasting
Re-handling of excavated material including loading unloading and dressing within initial lead of 50 m and lift of 1.5m with cost of de-watering wherever required and all applicable taxes and levies etc. complete in all respect Earth / Soil
Earth work in rough (borrow area) excavation for embankments in hard soil, morrum or highly weathered strata dry or moist, including laying in 20 cm layers (before compaction) and breaking of clods, sorting of grass, pebbles etc. and dressing when compacted by vibro compactor, vibro sheep foot roller, sheep foot roller/pneumatic tyred roller to obtain dry density of at least 98% of Standard Proctor s density with initial lift of 1.5m (Excluding charges for compaction and watering) including loading and un-loading wherever required complete in all respect.With initial lead of 250 m 5.17.2 Deduct in item no 16 (a) to (d) above if Standard Proctors density to be achived is at least 90%
Earth work in rough (borrow area) excavation for embankments in hard soil, morrum or highly weathered strata dry or moist, including laying in 20 cm layers (before compaction) and breaking of clods, sorting of grass, pebbles etc. and dressing when compacted by vibro compactor, vibro sheep foot roller, sheep foot roller/pneumatic tyred roller to obtain dry density of at least 98% of Standard Proctor s density with initial lift of 1.5m (Excluding charges for compaction and watering) including loading and un-loading wherever required complete in all respect.With lead beyond 250 m and up to 750 m ( Km)
Add extra for each subsequent lead of 500m or part there of beyond 0.50 Km and up to 5 km 5.17.2 Deduct in item no 16 (a) to (d) above if Standard Proctors density to be achived is at least 90%
Extra lead over item no 1 to 8 of excavated material. Add extra for each subsequent lead of 500m or part, there of beyond 0.50 Km. and upto 5 Km
Compaction of earth or highly weathered strataBy manually or plain roller. (density 90% of Proctor)
(i) Compaction of earth or highly weathered strataBy mechanical equipment such as sheep foot roller/ pneumatic tyred roller/vibro compactor / vibro sheep foot compactor required as per site condition to obtain dry density of.at least 95% of Standard Proctor s density
Watering of earth including cost of carriage of water when source of water is up to 1 Km
Preparation of surface of existing concrete surface/ masonry in lime mortar/ cement mortar including removal of organic deposit by washing with etching compound and use of wet sand blasting and final washing the surface with air and water jet including cost of all material and equipment required for the work complete.
Distance stone well dressed of required shape and size 60 cm x 23 cm x 7 cm with exposed faces chiesel dressed.
Fixing of Distance stone in 30x30x30 cm pit excavated in all type of strata and back filling with cement concrete (1:4:8) projected 10 cm above ground level well finished and properly cured. (Excluding cost of Distance stone)
Painting distance mark stone and lettering with light blue white or yellow un-washable paint including cost of material
Providing and Laying in position of Cement concrete Nominal mix (1:2:4) including leads of all construction materials, curing, compaction and finishing with rendering in cement sand mortar 1:3 (1 cement : 3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement. Well graded crusher broken stone aggregate of maximum size upto 20 mm
Dismantling cement concrete including disposal of material within 50 m lead, inclusive of de-watering wherever required. 20.17.1 The rates given are for dismantling of good quality work. For dismantling poor quality or weathered ; weakened work the rates will be reduced by 30%
Demolishing stone rubble masonry including stacking of usable material and disposal of unuseable material within 50 meters lead inclusive of de-watering wherever required.In cement mortar 20.17.1 The rates given are for dismantling of good quality work. For dismantling poor quality or weathered ; weakened work the rates will be reduced by 30%
Random rubble stone masonry (using R. R. stones where 75 % stones to be not less than 15 cm in size in any direction and weighing not less than 23 kg.) for foundation including curing with all leads of all construction materials including curing etc. complete. In cement sand mortar 1:5
Random rubble stone masonry (using R. R. stones where 75 % stones to be not less than 15 cm in size in any direction and weighing not less than 23 kg.) for foundation including curing with all leads of all construction materials including curing etc. complete. In cement sand mortar 1:5 7.13 Add extra for superstructure brick masonry on item no 10
Random rubble stone masonry (using R. R. stones where 75 % stones to be not less than 15 cm in size in any direction and weighing not less than 23 kg.) for foundation including curing with all leads of all construction materials including curing etc. complete. In cement sand mortar 1:6
Random rubble stone masonry (using R. R. stones where 75 % stones to be not less than 15 cm in size in any direction and weighing not less than 23 kg.) for foundation including curing with all leads of all construction materials including curing etc. complete. In cement sand mortar 1:6 7.8.1 Add extra over item no. 1 to 7 for Masonry work in superstructure
Coursed stone Kharanja masonry (using hammer dressed stones not less than 20 cm in any direction and at least 50 % stones to be more than 23 cm in depth) up to 0.5 thickness on top of exposed face, including all leads of all construction materials including curing etc. complete. In cement sand mortar 1:5 7.8.1 Add extra over item no. 1 to 7 for Masonry work in superstructure
Dismantling old plaster or skirting, racking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 m lead, inclusive of de-watering wherever required. 20.17.1 The rates given are for dismantling of good quality work. For dismantling poor quality or weathered ; weakened work the rates will be reduced by 30%
Plaster in cement sand mortar 1:3 including racking of joints, smooth finishing and curing etc. complete including all leads of all construction materials of thickness: 20 mm
Plaster in cement sand mortar 1:4 including racking of joints, smooth finishing and curing etc. complete including all leads of all construction materials of thickness: 20 mm
Providing and laying cement concrete coping in (1:2:4) with maximum size of crusher broken aggregate upto 20 mm including shuttering etc. with all leads of material complete in all respect in thickness of: 75 mm
Supplying and laying quarry spalls properly graded but not more than 10cm in size with spreading in required profile including all leads and lifts
Providing and Laying in position of Cement concrete Nominal mix (1:1.5:3) including leads of all construction materials, curing, compaction and finishing with rendering in cement sand mortar 1:3 (1 cement : 3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement. Well graded crusher broken stone aggregate of maximum size upto; 20 mm
Side shuttering including propping etc. complete (to achieve finish F 2 for :Top or intermediate bed plates, in between masonry or piers, abutments sluice wells etc.
Supplying of M.S. reionforcement including labour charges for bending binding and placing in position all reinforcement as per drawing including cost of binding wire and all leads and lifts using. Tor or ribbed bars (IS :1786-1985)
Preparation and dressing the sub grade including removal of irregularities up to 7.5 cm in soil, morrum mixed with pebbles, small boulders and kankar and murrum for Side slopes
Preparation and dressing the sub grade including removal of irregularities up to 7.5 cm in soil, morrum mixed with pebbles, small boulders and kankar and murrum for Bed
Providing Rubber seals as per IS:11855 for Dam sluice, canal, barrage, stop dam etc. gates of required size and type and specifications with testing, including all lead and lifts, packing and forwarding charges for all components etc. complete. Rubber seal musical note type 100mmx44mm x14mm (44mm Bulb) uncladed
Labour charges for removal of existing wornout/damaged bottom rubber seal of crest Radial Gates, Vertical Gates and Intake Service Well Gates of Dam by cutting bolts with gas cutter, providing holes in new rubber seal insertion of sleevs and fixing over gates with nut blots, washer ect including cost of gas (LPG and Oxygen) cylinder etc complete.
Labour charges for removal of existing wornout/damaged side rubber seal of crest Radial Gates, Vertical Gates and Intake Service Well Gates of Dam by cutting bolts with gas cutter,providing holes in new rubber seal insertion of sleevs and fixing over gates with nut blots, washer ect including cost of gas (LPG and Oxygen) cylinder etc complete
Design, Drawing, fabrication, supply, erection, testing and commissioning of Vertical lift sliding type Dam Shutter gates interchangeable consisting of sealing frame (embedded parts), skin plate of shutters, stiffeners, horizontal and vertical girders, guide, stainless steel flat, lifting hooks, clits fasteners etc., with all accessories including frame and gate complete set for Barrage/ Stop dam/ waste weir / spillway including cost of all materials, machinery, labour, cutting, aligning, welding, finishing, cleaning, tools and tackles, seal fixing, applying one coat of zinc rich epoxy primer and three coats of cold applied coal tar epoxy paint, including primer coating, should not be less than 350 microns., etc. complete as per specifications and approved drawings, including packing and forwarding, transportation charges for structural steel components and other materials.
Centering and shuttering for slabs, beams, lintels Columns, trough with or without caps and base including propping and remove
Making standard type cement gauge including engraving letters and painting including scaffolding etc.
Structural steel work in single section fixed with connecting plate including cutting hoisting fixing in position and applying a priming coat of approved steel primer all complete above plinth level upto 4.5 mtr. height In flates, tees, angles & Channals
Providing and laying canal lining with mechanically vibrated 300 x 150 x 50 mm PCC blocks made from concrete mix 1:2:4, A20 including all leads and lifts of material, curing, stacking, loading, unloading and transportation of blocks from manufacturing site to lining site. Single tile lining consisting of 12 mm thick cement mortar (1:6) plaster on sub-grade, 12 mm thick sandwich plaster in cement mortar (1:5) over sub grade and 50 mm thick tile lining in cement mortar (1:3) laid over 6 mm thick mortar layer in cement mortar (1:3) including curing, all leads of all construction materials, curing charges and machinery charges with mixture vibration etc., complete as per technical specifications.In sides
Providing and laying cast in situ plain cement concrete design mix M-15 grade for lining, using well graded crusher broken aggregate of maximum nominal size 20 mm conforming to IS:383-1970, including proportioning of the ingredients by weigh batching and mixing by mechanical mixer including finishing of concrete lining, cutting of grooves for construction joints, complete as per specification with all leads and lifts of construction material complete for canal bed of thickness. 7.5 cm
Filling of construction joints with Bitumen based sealing compound lining in the grove as per IS made by cutter upto the 1/3 depth of concrete lining as per specification provided in IS: 3384-1986 and all leads of all construction materials including cost of sealing compound, complete in all respect.
Providing and laying under drainage below canal lining consisting of porous concrete of mix ratio 1:4 (1 cement: 4 course aggregate) 75 mm diametre, 300 mm long supported by 75 mm thick layer of coarse aggregate 12.5 mm to 40 mm size and 50 mm thick layer of sand.
Dismantling of masonry with care inclusive of de-watering wherever requiredDry stone masonry or pitching
Supplying stone, spall and laying Rip rap in required profile properly hand packed using stone of specified size including all lead and lifts Only labour charges for laying of rip rap stone in required profile / thickness and hand packed properly using stones already available at site, including all lead and lift.
Supplying stone, spall and laying Rip rap in required profile properly hand packed using stone of specified size including all lead and lifts 23 cm thickness ( 5 % thickness tolerance)
Demolishing of reinforced concrete including stacking of usable material and disposal of unuseable material within 50 m lead inclusive of de-watering wherever required. 20.17.1 The rates given are for dismantling of good quality work. For dismantling poor quality or weathered ; weakened work the rates will be reduced by 30%
Providing and Laying in position of Cement concrete Design mix M-20 including leads of all construction materials, plasticizers (if required), curing, compaction and finishing with rendering in cement sand mortar 1:3 ( 1 cement : 3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement. Well graded crusher broken stone aggregate of maximum size upto; (For mix design Cement content considered 400 kg/ cum of concrete) 20 mm
Providing and Laying in position of Cement concrete Design mix M-30 including leads of all construction materials, plasticizers (if required), curing, compaction and finishing with rendering in cement sand mortar 1:3 ( 1 cement : 3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement. Well graded crusher broken stone aggregate of maximum size upto; (For mix design Cement content considered 428 kg/ cum of concrete) 20 mm
Providing, laying and fixing in position RCC spun or hume pipe with collars (ISI 458-2003) in required size packed in gasket for hume or spun yarn and neatly finished with rich grout of cement mortar 1:3 perfectly air tight including testing of joints. 200mm NP2
Providing, laying and fixing in position RCC spun or hume pipe with collars (ISI 458-2003) in required size packed in gasket for hume or spun yarn and neatly finished with rich grout of cement mortar 1:3 perfectly air tight including testing of joints. 300mm NP3
Providing, laying and fixing in position RCC spun or hume pipe with collars (ISI 458-2003) in required size packed in gasket for hume or spun yarn and neatly finished with rich grout of cement mortar 1:3 perfectly air tight including testing of joints. 900mm NP3
Extra labour charges for RCC due to obstruction in laying and placing the reinforced cement concrete due to reinforcement. Columns, slabs, cantilevers projections staircases, lintels, beams, chajjas, Retaining walls, piers, abutments, galleries, arch covers, bed plates, sluice capstan bases etc.
Refilling the excavated earth (excluding rock) in trenches, plinth side of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering including cost of water, loading and un-loading wherever required with cost of dewatering wherever required.
Providing and laying cement concrete coping in (1:2:4) with maximum size of crusher broken aggregate upto 20 mm including shuttering etc. with all leads of material complete in all respect in thickness of: 50 mm
Providing and Laying in position of Cement concrete Nominal mix (1:3:6) including leads of all construction materials, curing, compaction and finishing with rendering in cement sand mortar 1:3 (1 cement : 3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement. Well graded crusher broken stone aggregate of maximum size upto 20 mm
(i)Removal of slit/soil/earth, sand, pebbles, Malba , debris, rubbish, stone pebbles and obstruction deposited in canal bed up to design line grade and sections having design due to erosion/scour/slips in canal banks/silting with or without bushes and weeds etc. in dry or moist condition from canal bed including dewatering, loading unloading and disposal at suitable place as directed by Engineer in charge with initial lead of 50m. and lift upto 1.5 m with proper dressing on canal bed complete in all respect For depth above 15 cms but upto 30cms having Unlined section
Brick masonry lining consisting of 12 mm thick plaster in cement mortar (1:6) on sub grade, 16 mm thick sandwich plaster in cement mortar (1:3) over base plaster and 70 mm thick brick masonry in cement mortar (1:3) laid over 6 mm thick mortar layer in cement mortar (1:3) including curing etc. including all leads of construction materials complete as per specifications. In bed
Brick masonry lining consisting of 12 mm thick plaster in cement mortar (1:6) on sub grade, 16 mm thick sandwich plaster in cement mortar (1:3) over base plaster and 70 mm thick brick masonry in cement mortar (1:3) laid over 6 mm thick mortar layer in cement mortar (1:3) including curing etc. including all leads of construction materials complete as per specifications. In sides
Add extra over item no. 1 to 7 forEach subsequent height of 3.0 metre or part thereof above initial lift of 5.0 m from ground level (up ward and down ward) for item other than 6 and 7.
Flush or ruled pointing on stone masonry including racking of joints and curing etc. complete including all leads of all construction materials in mortar ratio. In Cement sand mortar 1:3 8.15 Add extra over item No. 13 to 14 for height from more than 5 m from base / floor level of structure / building for every additional height of 3.0 m or part there-of (upward and downward).
Flush or ruled pointing on stone masonry including racking of joints and curing etc. complete including all leads of all construction materials in mortar ratio. In Cement sand mortar 1:3
Add extra over item No. 1 to 7. For each subsequent height of 3.0 meter or part thereof above initial lift of 5.0 m from ground level. (upward and downward)
Plaster in cement sand mortar 1:3 including racking of joints, smooth finishing and curing etc. complete including all leads of all construction materials of thickness: 20 mm 8.15 Add extra over item No. 13 to 14 for height from more than 5 m from base / floor level of structure / building for every additional height of 3.0 m or part there-of (upward and downward).
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils
Providing and laying cement concretee including curing, compaction etc. complete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, levelling course etc up to floor five level excluding the cost of centering and shuttering. M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in: Cement Mortar 1:6 ( 1-Cement : 6-Sand).
Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : Cement mortar 1 : 6 (1 cement : 6 coarse sand)
Providing and laying damp-proof course with cement concretee grade M-150 (1 : 2 : 4) mortar prepared with 1% solution of water-proof compound complete as per specification . 50mm thick.
Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for : Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc.
Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. (Original producers who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786) Thermo-mechanically Treated bars (Conforming of relevent IS code)
Providing and laying in position specified grade of cement concretee for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix
P & F 1st qualityVitrified Porcelain Polished tiles on floor, skirting and steps etc.in different sizes (thickness to be specified by manufactuer) with water absorption less than 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1 : 4 including grounting the joints with white cement and matching pigment etc complete. size 600 mm X 600 mm
Plaster on new surface on walls in cement sand mortar 1:4 including racking of joints etc. complete fine finish : 12mm thick .
Pointing on brick work or brick flooring with cement mortar 1:3 (1 cement : 3 fine sand) : Flush / Ruled/ Struck or weathered pointing.
Providing and fixing M.S. sheet 1mm thick single leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint
Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (IS 1038-1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concretee block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required : Windows side hung /Ventilators top or centre hung (openable)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
Providing and fixing Square bars or other flat welded to window, ventilatiors etc.
P & F G.I. pipes (Internal Work) with G.I. Fittings excluding union (IS:1239 Mark) & MS clamps including cutting and making good the walls and floors: Exposed on wall 15 mm dia nominal bore A Class
Supply & fixing G.I. Union ISI marked in G.I. pipe line as required complete in all respect of size : 15mm dia nominal bore
P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make: Brass 400 gm,15mm nominal bore.
P & F Stop Cock (IS :8931 Mark), superior quality & of approved make: Brass 400 gm. 15mm nominal bore.
P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make : Gun-metal 15mm nominal bore.
P. & F Squatting Pan (Indian type) white glazed vitreous china 1st quality W.C. Pan (IS : 2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor (excluding the pair of foot rest.) Size 510 mm
P & F WVC Foot- rest (IS: 2556 Mark) including cutting and making good the floor size. 250 x 125 x 25 mm
P & F Low level Flushing Cistern of 10 litres capacity (IS : 2556 mark) of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball (IS: 1703 mark) complete including cutting and making good the wall: PVC with PVC bend as per IS : 7231 .
P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant. 110 mm dia
P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant. 75 mm dia
P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: Reducer 110 X 75 mm 110mm dia
P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: Plain Tee 110mm dia
P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: Bend 87.5 110mm dia
P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: Socket plug 110mm dia
P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: W.C. connector bent type 110mm dia
Construction of Soakage well in all types of soil of approved drawing, top 90 Cm .Portion in 450mm thick masonry with CM 1:6, 80 mm thick stone slab covering, jointing of slab in CM 1:3 ,Ralthal, kharanja 40mm thick M-15 grade C.C flooring, earth work etc . complete including disposal of surplus earth within a lead of 50 mtr . Inner dia 90 Cm & 10 to 12 Mtr deep.
P & F PVC Storage Tank ISI Marked (IS : 12701) indicating the BIS license No), of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design:1000 (-do-)
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding: New work (two or more coats) over and including scrapping and priming coat with cement primer.
Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR - Short point (up to 3 mtr.)
Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR - Medium point (up to 6 mtr.)
Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR - Long point (up to 10 mtr.)
Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR - 2 x 6.0 sq. mm. + 1 x 2.5 sq. mm.
Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR - 2 x 6.0 sq.mm
Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR Double pole MCB(With B/C curve tripping Characteristics) - 40 A rating
Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR Single pole MCB (With B/C curve tripping Characteristics) - 6 A to 32 A rating
Providing & Fixing of BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan Conforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . - 1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 )
Providing & Fixing of IP 20 box made out from 1.2mm thick CRCA sheet steel with depth of minimun 30 mm and finished with powder coating and suitable for mounting LED tube including side covers, holders , internal wiring to illuminate the single sided connection LED tube. ( Without tube). All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . - Suitable for 4 LED Tube shape fixture for double rod
Providing & Fixing of energy efficient direct fit (Retrofit) Polycarbonate/ Glass housing SMD Mid Power LED tube rod (with integral driver & alumn. heat sink ), on existing fixture. system lumen efficacy = 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.=0.95,CRI >80 , life time of minimum 35000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . - 1200mm , Min. Lumens output 2000 lm LED Tube rod with Polycarbonate Housing
Providing & Fixing of energy efficient /energy saving IP 20 LED direct retrofit Bulb in existing holder or fixture as required with system lumen efficacy =100 lm/Watt output ,pf 0.95 , CRI >70, minimum life time of minimum 25000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . for additional technical parameters of product/ work, refer Annexure "A" attacheded with this BSR. - 9 Watt
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.03 MB
FINBID.pdf
Tender Documents • 5.75 MB
BOQ_654519.xls
BOQ • 0.31 MB
Drawing.pdf
Other Document • 5.33 MB
Download all tender documents and submit your bid