| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.2 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹16.0 L+₹2.8 L (21.5%)Rejected-Finance FLAT NO 4 VIRGINIA CO OP HOUSING SOCIETY AIR PORT ROAD CHICALIM VASCO DA GAMA GOA 403 711 | SOUTH GOA | GOA | 403711 | L2 | Rejected-Finance Higher Bidder | |
| 3 | L3₹16.9 L+₹3.7 L (27.8%)Rejected-Finance C2 PAIXOMONTIRO APTS BEHIND NSD ALTO DABOLIM VASCO DA GAMA GOA 403 801 | SOUTH GOA | GOA | 403801 | L3 | Rejected-Finance Higher Bidder | |
| 4 | L4₹17.4 L+₹4.2 L (31.9%)Rejected-Finance | L4 | Rejected-Finance Higher Bidder | |
| 5 | L5₹17.8 L+₹4.6 L (34.7%)Rejected-Finance FLAT NO 03 PANCHAVATI BUILDING ADARSH NAGAR CHICALIM GOA 403711 | SOUTH GOA | GOA | 403711 | L5 | Rejected-Finance Higher Bidder |
Tender Value
₹22.5 L
EMD Value
₹45,000
Closing Date
17 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SH A K SINGH SE CWE NAVY VASCO
CWE NAVY VASCO VASCO DA GAMA GOA 403802
PROVISION OF ADDITIONAL SEWAGE LINE AND SEPTIC TANK 400 USERS 2 NOS AND SOAK WELL 2 4 M DIA AND 3 M DEPTH 2 NOS AT VAT SITE AT SMA VARUNAPURI UNDER GE NW VASCO
2021_MES_497863_1
85549/E8
Open Tender
Civil Works
Item Rate
180 days
CWE NAVY VASCO
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
Yes
GE (NW)VASCO
₹45,000
Yes
7 Mar 2022
28 Dec 2021
19 Feb 2022
28 Dec 2021
17 Feb 2022
3 Feb 2022
60 days
Amount
Excavation over areas not exceeding 1.5 m deep in hard dense soil and getting out complete all as specified and as directed.
Excavation over areas not exceeding 1.5 m deep in soft/disintegrated rock and getting out complete all as specified and as directed.
Excavation over areas exceeding 1.5 m and not exceeding 3.00 m deep in hard dense soil and getting out complete all as specified and as directed.
Excavation over areas exceeding 3.00 m and not exceeding 4.50 m deep in soft/ disintegrated rock and getting out complete all as specified and as directed.
Excavation over areas exceeding 4.50 m deep in soft/ disintegrated rock and getting out complete all as specified and as directed.
Returning ,filling in including spreading levelling watering and well ramming of soft/loose soil in layers not exceeding 25 cm thick complete all as specified and as directed.
Removing excavated material exceeding 250 m but not exceeding 500 m and depositing where directed
M& L for cement concrete 1:2:4 Type B1 using 20 mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed.
M&L for pre-cast cement concrete block masonry type C-5 with solid blocks, exceeding. 10 cm in width and setting in mortar 1:6, complete all as specified and as directed
M & L for precast cement concrete hollow block masonry exceeding 10 cm in width and setting in mortar 1:6 complete all as specified and as directed
M&L for reinforced cement concrete design mix M-20 using 20 mm graded stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5 m span complete all as specified and as directed.
M&L for reinforced cement concrete design mix M-20 using 20 mm graded stone aggregate in slabs supported on walls, beams and columns in floors, roofs,landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
M&L for formwork to soffits of suspended slabs such as roof slab, floor slabs, landing and similar work not exc 200mm thick; rough finished surfaces of concrete flat complete all as specified and directed.
M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc rough finished surfaces of concrete flat complete all as specified and as directed.
S&F Hand rails, half round or other stock section, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.)., and similar work conforming to Fe 290 gde E 165 complete all as specified and as directed.
S&F Mild steel TMT bars 10mm dia and over, cut length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to complete all as specified and as directed.
All as per Item No.16 here in before but 6mm to 8mm dia all as specified and as directed.
S&F framed work such as grills gratings, etc., with ends of bars shouldered and/ or riveted, or forged into a pikes; framed guard bars; barred iron doors; ladders; framed baluster, walk ways; railings; framed work or water tanks and similar work conforming to Fe 290 gde E 165 complete all as specified and as directed.
S&F Asbestos cement pipes of 100mm bore dia in any length with cement joints fixed to wall complete all as specified and as directed.
S & F AC slotted vent cowl of 100mm bore dia complete all as specified and as directed.
M&L for rendering 10 mm thick in cement mortar 1:4 on wall of brick work concrete surface, finished fair and even complete all as specified and as directed.
M&L for rendering 5mm thick in cement mortar 1:3 on wall of brick work or concrete surface, finished fair and even all as specified and as directed
Supply only liquid water proofing compound complete all as specified and as directed
Surface dressing not exceeding 15cm deep and getting out in hard/dense soil complete all as specified and as directed
M&L for formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 20cm wide. (Where RCC/PCC band in walls, spanning and opening, the formwork
M&L for hard core of broken bricks for loose filling using 63mm to 100 mm of size complete all as specified and as directed.
S&F PVC (SWR) pipes 110mm single socketed in any length with rubber ring joints, laid in trenches or in floor complete all as specified and as directed.
S&F PVC (SWR) Bend pipes 110mm with or without access door fixed complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth in depth for foundation etc, or cesspits, manholes, pier holes, etc not exceeding 10 Sqm on plan and getting out in soft/ disintegrated rock complete all as specified and as directed.
Excavation in trenches exc 1.5m wide deep and not exceeding 3.0m in depth for foundation etc, or cesspits, manholes, pier holes, etc not exceeding 10 Sqm on plan and getting out in soft/ disintegrated rock complete all as specified and as directed.
M & L for PCC (1:2:4) type B1, using 20 mm graded stone aggregate as in copings and the like including weathering, slightly rounded or chamfered angles and throating with and including necessary use and waste of formwork complete all as specified and as directed
M&L for rendering 15 mm avg thick cement plaster in cement mortar 1:4 (10mm thick 1st coat+ 5mm thick finishing coat) on solid block masonry work mixed with WPC as per manufacturers instructions finished the surface even and smooth without using extra cement complete all as specified and as directed. Note: Water proofing compound shall be measured and paid separately
M&L for precast cement concrete (1:2:4) type B1, using 20mm graded stone aggregate as in cover slab for manholes, etc set in cement mortar 1:4 including necessary use and waste of formwork complete all as specified and as directed.
M & L for PCC (1:2:4) type B0, using 12.5 mm graded stone aggregate as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed
M & L for PCC (1:3:6), type C-2, using 40mm graded stone aggregate as bedding layer of the drain pipe and including packing under haunching against the sides of pipe and after they laid and tested for 200mm dia pipe, etc. complete all as specified and as directed.
M&L for 200 mm dia reinforced concrete pipe class NP-2 laid and jointed complete with collars all as specified and as directed.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms moulds mitred/stopped ends etc complete all as specified and as directed.
S&F Mild steel band straps, supported or stays, for fixed manholes and similar small articles conforming to fe 290 Gde E-165 complete all as specified and as directed.
M/S jvsr constructions
M/S P S BABU
Leela Enterprises
M/s. P S REDDY
M/S Kartik Enterprises
M/S. M M S ENTERPRISES
Tara Construction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .