EEE-II/SSZ
MUNICIPAL CORPORATION OF DELHI OFFICE OF THE Ex. ENGINEER (ELECT)-II 2 nd Floor Technical Laboratory Near NH-24 Ghazipur Delhi
Provision of lighting arrangements at Mpl park of Bholanath Nagar in ward 215 under SSZ
2024_MCD_181344_1
EEE-II/SSZ/2023-24/32.5
Open Tender
Electrical Works
Item Rate
90 days
work
Please refer to tender documents
4 documents required · 4 mandatory
₹590
₹9,503
29 Jan 2024
11 Jan 2024
19 Jan 2024
11 Jan 2024
18 Jan 2024
11 Jan 2024
Amount
122.1.2:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*6 sqmm
122.2.4:SITC of Pillar box size 900 mm x 450mm x 250mm suitable for mounting incomer of 250 A MCCB/Main switch 4 Pole and energy meter 3 phase complete with eluotropic grade Aluminium bus bar of size 25mm x 19 mm mounted on galvanized M. S. body power quoted pilferage proof SMC door duly welded with S.S. with rain cover size 40mm x 40mm x 5mm x 600mm height in cutting 300 mm height below ground and covered with shode proof SMC sheet of 3 mm as required.
122.2.139:Supplying and laying of following size of C PVC pipe in along with all accessories like socket, bend, couplers etc. conforming to IS :4985:2000, Part II complete with fitting and cutting, jointing etc. direct in ground ( 50 cm below ground level ) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. complete as required. 25 mm dia
122.2.140:Fabrication, supplying, installation, testing and commissioning of Bollard light having length 750mm of MS Sheet i/c making design by Laser cutting , as approved by engineer In charge and welding the same, with 2 nos. 10 watt warm white 2 feet long LED tube light fitting and having suitable arrangement to accommodate 2 nos. 10 watt warm white 2 feet long LED tube light , duly painted with one coat of primer and two coat PU paint i/c J-type foundation nut bolt but excluding foundation complete etc. as required.
122.2.156.(b):P&F following sizes of PVC insulated & PVC sheathed copper conductor 3 core submersible cable confirming to IS.694/1990 etc. as reqd. 3x 4 sq.mm
122.2.120:Supplying and fixing 63A, 4 Pole rating, 415V, and 10KA ''C Curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB Complete with connections, testing and commissioning etc. as required.
122.2.24:Providing and laying of HDPE PIPE OF 40mm outer dia with PN 4 rating by hand Moling/Mannual method Confirming to IS 4984 592
DSR ELECTRICAL
OD22187/2023-2024:DSR 22.2.12.2 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63Amps
OD22188/2023-2024:DSR22 14.16.3 S & L of following size DWC HDPE pipe ISI marked along with all accessoried like socket ,bend,couplers etc. Confirming to Is 14930, Part II complete with fittings and cutting jointing etc. Diret in ground (75 Cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covring etc. complete as reqd. (a) 63 mm dia (OD-63mm & ID-51 mm nominal.
OD22189/2023-2024:7.5.1:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm
OD22190/2023-2024:5.16:Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
OD22191/2023-2024:5.1:Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
OD22819/2023-2024:DSR 22 14.6 Excavation of the cable trenches in hard rock not exceeding 1.5 metres in width, and lift upto 1.5 metres, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 metres
DSR CIVIL
4.3.1:Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns
4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
Iluminators And Circuiteers
Bidder Name
Iluminators And Circuiteers
M/S. A.K. Electricals
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .