| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.8 LAccepted-AOC | L1 | Accepted-AOC THE LOWEST TENDERER | |
| 2 | L2₹39.2 L+₹3.4 L (9.37%)Rejected-Finance | L2 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 3 | L3₹39.2 L+₹3.4 L (9.42%)Rejected-Finance 1331 GENERAL GANJ OPP WATER TANK MATHURA 281001 | MATHURA | UTTAR PRADESH | 281001 | L3 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 4 | L4₹39.3 L+₹3.5 L (9.71%)Rejected-Finance | L4 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 5 | L5₹40.0 L+₹4.2 L (11.8%)Rejected-Finance | L5 | Rejected-Finance NOT THE LOWEST TENDERER |
Tender Value
₹47.3 L
EMD Value
₹94,700
Closing Date
18 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE EAST MATHURA
Garrison Engineer East Military Engineer Services Mathura Cantt Mathura 281001
SPECIAL REPAIR TO BLDG NO E-06 (OR LIVING AND DINING HALL) AT OD COMPLEX UNDER GE (EAST) MATHURA
2024_MES_676970_1
8200-1452/E8
Open Tender
Civil Works
Item Rate
180 days
GE EAST MATHURA
AS PER TENDER DOCUMENTS
11 documents required · 11 mandatory
₹500
GE EAST MATHURA
₹94,700
30 Nov 2024
27 Sept 2024
25 Oct 2024
27 Sept 2024
18 Oct 2024
11 Oct 2024
27 Sept 2024 - 18 Oct 2024
Amount
Dismantling of plain or corrugated steel sheeting any gauge, thickness, including including ridges, hips, valleys etc complete all as specified and as directed.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet AZ-150, thickness of 0.50mm of red colour having tensile strength of 550 Mpa as per IS 15965: 2012 in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet AZ-150, thickness of 0.50mm of required colour having tensile strength of 550 Mpa as per IS 15965: 2012 as in ridges/valley gutters, fixed with self tapping screws complete all as specified and as directed.
Demolition of brick work or stone boulder masonary built in cement mortar including all quoins arches, pillars etc. but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and as directed.
M&L for Brick work with sub-class 'B' Bricks straight or curved on plan exc 6 m mean radius as wall built in cement and sand mortar 1:6 complete all as specified and directed.
Taking down cement plaster on brick walls and concrete surface including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and as directed.
M&L rendering 15mm thick plaster on other than fair face of brick work or concrete surface in cement mortar 1:4 and finished the surface even & fair complete all as specified and as directed.
M&L for rendering 10 mm thick on fair faces of brick work or concrete surface in cement mortar 1:6 finished even & smooth without using extra cement complete all as specified and as directed.
M&L for preparation of newly plastered surface of walls and two coat of distemper oil emulsion over and including a coat of alklai resitant primer complete all as specified and as directed.
M&L for complete removal of existing treatment from old plastered surfaces of walls preparation of surface and applying two coats of distemper oil emulsion white or tinted on old walls complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint, white or tined on new wall surfrace over and including a coat of primer complete all as specified and as directed.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing and rubbish off the premises complete all as specified and directed.
M&L for Non Skid ceramic coloured tiles 7 to 8 mm thick, (Square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15 mm thick screed bed in cement motar 1:4 complete all as specified and as directed.
All as per item items 13.00 here-in-before but as on vertical surfaces laid over and including 10 mm thick rendering in cement motar 1:3 complete all as specified and as directed.
M&L for Glazed ceramic coloured tiles in vertical surface of size 450x300x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 10 mm thick backing coat of cement motar 1:3 complete all as specified and as directed.
M&L Machine cut kota stone slab flooring 20-25 mm thick laid over and including 20mm thick screed bed in cement mortar 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
M&L kota stone slab 20-25 mm thick in riser of steps, skirting, dado and pillar laid over and including 10 mm thick rendering in cement mortar 1:3 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
Taking down Chowkhats or frames with shutter without taking off shutters from the frames area exc. 1.5 sqm but n exc 4.00 sqm each complete all as specified and as directed.
S&F Pressed steel frames of size 125 x 60 mm fabricated out of 1.25mm steel sheet for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. complete as specified and as directed.
S&F Pressed steel frames of size 105 x 60 mm fabricated out of 1.25mm steel sheet for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. complete as specified and as directed.
M&L for cement concrete 1:3:6 type C-1 (using 20 mm graded stone aggregate) as in bed blocks for fixing hold fasts and filling of pressed steel frame etc. complete all as specified and as directed.
S&F 30 mm thick factory made flush shutters, solid core construction with block board core and plywood face panel commercial type on both sides complete all as specified and as directed.
S&F 35 mm thick factory made second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc. sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) supplied and fitted to chowkats complete all as specified and as directed.
S&F MS Butt hinges medium weight colled rolled of size 100mm complete all as specified and as directed.
S&F aluminium handles cast type anodised of 150mm size complete all as specified and as directed.
S&F aluminium anodized barrel tower bolts 200 mm length of bolt of extruded section and fixed complete all as specified and as directed.
S&F Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts 250 mm long of extruded sections or cast aluminium alloy and fixed complete all as specified and as directed.
S&F in replacement steel windows with side hung shutter including box type hinges with steel handle of MS flat 25 x 5 mm and 2 Nos 100 mm long steel tower bolt fixed to shutter complete with and including glazing bars, dovetailed or welded, complete all as specified and as directed.
All as per item No 28.00 here-in-before but without Glazing bar, complete all as specified and as directed.
S & F window guard bars, plain and fixed independently in steel window frames, conforming to Fe 290 Gde E-165, complete all as specified and as directed.
S&F stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete as specified and as directed.
S&F 3mm thick, Sheet glass ordinary quality and glazing with ooil putty n exc 0.5 sqm in each pane complete all as specified and as directed.
S&F in repair 3mm thick, Sheet glass ordinary quality and glazing with oil putty n exc 0.5 sqm in each pane complete all as specified and as directed.
S&F in repair stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete as specified and as directed.
S&F in repair 25 mm dia stainless steel tubular drapery rod cut to size and fixed in position including fixing brackets, stop roller end caps etc complete all as specified and as directed.
Dismantling of stone slabs in roofs, suspended floors, chajjas landing etc any thickness, jointed in any mortar complete all as specified and as directed.
M&L for sand stone slabs of 75 mm thick in cills, landings etc n exc, 2m in length punched dressedon face and along exposed edges, self faced on other side and set and pointed in cement mortar 1:4 complete all as specified and as directed.
M&L for plain cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) as in coping, benching etc complete all as directed and as specified.
M&L for preparation of new steel surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamal paint over and including a coat of red oxide primer complete as specified and as directed.
M&L for prepration of new wooden surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over and including a coat of pink primer complete all as specified and as directed.
M&L for prepration of old painted wooden surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
M&L for preparation of old painted steel surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamal paint complete as specified and as directed.
S&F in repair 200 mm bore PVC rain water pipes single socketed, in any length with rubber ring joints, fixed to walls , valley gutters with suitable MS clamps and making it water tight as per manufacturers instructions complete all as specified.
S&F in repair PVC (Rain Water Pipe) 200mm bore bends any radius with oval access door complete as specified and as directed.
S&F in repair 200mm dia PVC tail piece any radius fixed in rain water pipe complete as specified and as directed.
Dismantling wall and ceiling boards (fiber, pulp, insulation, etc) or insulation board/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed .
M&L for providing and fixing inter locking metal grid (snap grid for false ceiling) of size 605 mm x 605 mm in true horizontal level, hot dipped galvanized steel sections (galvanized @ 120 grams/sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 24 mm X 38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross “T” of size 24 mm X 28 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm center to center to form a grid of 1200 mm x 600 mm and secondary cross “T” of length 600 mm and size 24 mm X 28 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200 mm X 600 mm panel to form grids of 600 mm X 600 mm and wall angle of size 24 mm X 24 mm X 0.4 mm. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 mm X 37 mm X 25 mm X 1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 mm X 30 mm X 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint for all hights complete all as specified and as directed.
M&L for 4 mm thick non-asbestos fibre cement building board having fire resistance & moisture resistance properties complete all as specified and as directed.
M&L in repair for 4 mm thick non-asbestos fibre cement building boards, fixed to timber/MS framework complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
S&F rolled mild steel work as in roof trusses (framed), trussed purlins, crane gantries, rails and faternings and heavy bracket framing (Beam, tee angle, channel or flat sections, MS hollow pipe) including distance pieces, cleats etc. conforming to Fe-410W Gde E-250 quality 'A' complete all as specified and directed.
Taking down carefully aluminum/copper point wiring (light ,fan, socket any type, power, bell etc.) complete including fixtures & fittings (such as ceiling rose, socket, Pendent, regulator, etc) and removing the material from site and making good the disturbed surfaces of walls ceiling etc complete all as specified and as directed.
Taking down carefully by Submain wiring of any type making good the disturbed surface to match with existing surface complete all as specified and as directed.
Taking down old unserviceable existing SPN/TPN DB/enclousers any size and type/any descriptions as iron sheet scrap including MCB any type/size and making good disturbed surface/wall as per existing complete all as specified and directed.
M&L for Point wiring complete with 1.5 Sqmm single core PVC insulated (FRLS) cable 1100 volts grade with multi-stranded, copper conductor drawn through and including 20mm dia rigid non-metallic PVC conduit with all acessories such as internal bend end caps etc complete concealed in walls/roof including cutting and chases (making good all to the disturbed surface to match with existing surface) including earth wire PVC insulated FRLS copper conductor multistandard of 1.5 sqmm size in green colour for the following complete all as specified and as directed the followngs:- Note :- Flush metal boxes, modular cover plate with frame shall be measured and paid separately under relevant items of this BOQ.
One light/fan/exhaust fan point controlled by one way switch 5 amp complete all as specified and as directed.
One 3 pin 5 Amps socket point controlled by one way switch on same board complete all as specified and as directed.
One 3 pin 5 Amps socket point controlled by one way switch on independent board complete all as specified and as directed.
All as per item No. 55.00 here-in-above but for 3pin/5pin 16Amps socket point controlled independently, with 4 Sqmm PVC insulated & unsheathed (FRLS) copper conductor cable independent Point wiring complete all as specified and as directed.
Supply and Fixing Modular switch 6 Amps single pole one-way, 1 Module complete all as specified and as directed.
Supply and Fixing Modular switch 16 Amp single pole one way,1 Module complete all as specified and as directed.
Supply & Fixing Modular fan Regulator electronic step type 2M complete all as specified and as directed.
Supply and Fixing Modular socket 2-in-1, 5 pins 6 Amps , combined 2 Module complete all as specified and as directed.
Supply and Fixing Modular socket 2-in-1,3 and 5 pins 6 /16 Amps, combined 2 Module complete all as specified and as directed.
S&F ceiling rose surface bakelite 65mm x 50mm three terminals complete all as specified and as directed.
S&F modular white cover plate with frame, 1 module complete all as specified and as directed.
S&F modular white cover plate with frame, 3 module complete all as specified and as directed.
S&F modular white cover plate with frame, 4 module complete all as specified and as directed.
S&F modular white cover plate with frame, 6 module complete all as specified and as directed.
S&F modular white cover plate with frame, 8 module complete all as specified and as directed.
S&F Modular metal flush box 1/2 Module incl cutting & chases (making good all to the disturbed surfaces as per existing) complete all as specified and as directed.
S&F Modular metal flush box 3 Module incl cutting & chases (making good all to the disturbed surfaces as per existing) complete all as specified and as directed.
S&F Modular metal flush box 4 Module incl cutting & chases (making good all to the disturbed surfaces as per existing) complete all as specified and as directed.
S&F Modular metal flush box 6 Module incl cutting & chases (making good all to the disturbed surfaces as per existing) complete all as specified and as directed.
S&F Modular metal flush box 8 Module incl cutting & chases (making good all to the disturbed surfaces as per existing) complete all as specified and as directed.
S&F indoor decorative ultra slim surface/Wall mounted LED batten tube light fitting with polycarbonate channel housing & integrated electronic driver,energy efficient, 140V-270 volts,co- related colour temperature (CCT) of 6500K, >100 Lm/Watt complete with all accessories internally pre-wired with and including 1 x 20 watt LED tube and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and as directed.
S&F intergrated Batten PC housing extruded T5 LED batten tube 2' light fitting complete with all accessories internally pre-wired with and including 1X9 watt LED Tube connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and as directed.
S&F in replacement of recess mounting LED light fitting 2x2, square shape 24W, 230V complete with all accessories internally prewired and including connected up with twin core twisted flexible copper conductor cable with suitable sizes complete all as specified and as directed.
S&F of 30W LED building security light fitting with lens & driver, powder coated pressure die cast aluminium, top opening and maintainable with heat resistance toughened glass, built-in Short-Circuit Protection, Over voltage Protection and Surge Protection, IP-65 proction with luminaire efficiecy of greater than 80Lumen/Watt, Colour rendering (CRI) of ≥ 70 and co- related colour temperature (CCT) of 5700K (±500K) . The luminaire should have 10 KV surg protection, PF ≥ 0.9 and total harmonic distortion of THD ≤ 10%, voltage range of 140-280V with and including 30W LED tube all connections complete all as specified and as directed.
S&F for building security light bracket made out of 40mm dia medium grade GI pipe of 1.2 m length bent to required shape suitable for fixing street light fitting on Steel tubular pole including two Nos clamps made out 40mm X 6mm flat with suitable nuts and bolts including applying two coats of aluminium paint over a coating of red oxide primer complete all as specified and as directed.
Taking down the ceiling fan/Exhuast fan of any sweep carefully from its installed position, dismantling complete, cleaning all dust, applying grease for bearings, reassembling the fan and blades, painting of fans with synthetic enamel paint by spraying a single coat as per existing colour paint including provision of 3 core twisted flexible copper conductor cable 0.75 Sqmm from ceiling rose to connector of fan, hanging/fixing the fan in its original position and testing on completion complete all as specified and as directed.
M&L for Sub Main Wiring with two runs single core 6 Sqmm PVC insulated unsheathed (FRLS) cable with multistranded, 1100 volts grade copper conductor drawn in suitable size of rigid non-metallic PVC conduit (not less then 25mm dia med gd) and its all accessories complete concealed in wall/roof incl cutting & chases( making good all to the disturbed surfaces as per existing) with and including 6sqmm copper green colour earth wire complete all as specified and as directed. Note: Two runs 6sqmm, one run of 6sqmm earth wire & One run of PVC conduit shall be measured as one unit length.
M&L for Sub Main Wiring with four runs single core 6 Sqmm PVC insulated unsheathed (FRLS) cable with multistranded, 1100 volts grade copper conductor drawn in suitable size of rigid non-metallic PVC conduit (not less then 25mm dia med gd) and its all accessories complete concealed in wall/roof incl cutting & chases( making good all to the disturbed surfaces as per existing) with and including 6sqmm copper green colour earth wire complete all as specified and as directed. Note: Four runs 6sqmm, one run of 6sqmm earth wire & One run of PVC conduit shall be measured as one unit length.
S&F TP&N Vertical Loadline distribution board, 8 Way, Double door, sheet steel, phosphatised, powder coated with Copper bus-bar 250Amp, two neutral link, earth bar with provision for 125Amps MCCB as incomer and SP/TP MCBs as outgoing, cable ties for cable management, 440 V, 4 way complete all as specified and as directed Note : - (i) MCB /MCCB DBs shall be of same make and measured and paid seperately under respective items of this BOQ. (ii) DB shall be fixed in surface/flush pattern by cutting the wall and making good disturbed surface as directed & rate shall be included in this item.
S&F MCB distribution board, TPN 4 Way, Double door, sheet steel, phosphatised, powder painted with bus-bar 200Amp, neutral link, earth bar and din rail , cable ties for cable management, 240 V, complete all as specified and as directed.
S&F sheet metal enclosure MCB distribution board, SPN 8 Way, Double door, phosphatised, powder coated with 200Amp rated bus-bar, neutral link, earth bar and din rail , cable ties for cable management, 240 V complete all as specified and as directed.
S&F MCB distribution board, SPN 4 Way, Double door, sheet steel, phosphatised, powder painted with bus-bar 200Amp, neutral link, earth bar and din rail , cable ties for cable management, 240 V, complete all as specified and as directed.
S&F SP enclosure modular type with a two pin and earth plug and socket complete with SP MCB of rating 20-32 Amps, 240V complete all as specified and as directed.
Supply and fixing MCCB 125Amp rating, 4-pole 415V, adjustable thermal and fixed megnetic type, 'C' series, breaking capacity 16KA complete all as specified and as directed.
S&F MCB TPN 40 to 100 Amps, 'C' series, breacking capacity 10KA, 240V complete all as specified and as directed.
S&F in replacement MCB TP 40-63 Amps, 'C' series, breacking capacity 10KA, 240V complete all as specified and as directed.
S&F MCB DP 40-63 Amps, 'C' series, breacking capacity 10KA, 240V complete all as specified and as directed.
S&F MCB SP 6-32 Amps, 'B' series, breacking capacity 10KA, 240V complete all as specified and as directed.
Supply, laying, jointing and testing of XLPE insulated, sheathed, armoured, heavy duty LT 1100 volts grade cable with aluminium conductor of size 50 Sqmm 3.5 core laid in trenches/duct/fixing on walls with suitable lugs, glands, nuts and bolts in existing Panel from pole/Main Panel Box etc complete all as specified and as directed. Note:- Excavation and earth work shall be measured and paid separately under relevant item(s) of this BOQ.
Excavation in trenches in not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide for foundations, laying of cables etc and getting out as in soft/loose soil complete all as specified and as directed.
Returning, filling in including spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25 cm thick complete all as specified and as directed.
Removal of excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed.
M&L for sand filling in trenches with clean dry fine sand unwashed including gently punning around cables complete all as specified and as directed.
Supply and Laying in trenches Unreinforced precast concrete cable cover class LV type 1, flat, size 250mmx150mmx40mm complete all as specified and as directed.
Supplying & fixing steel tubing ,galvanised, medium grade 40 mm bore with all fittings and fixed complete to walls and ceiling or laid under floor complete all as specified and as directed.
Material and labour for Earthing complete with GI earth plate 600mm x 600mm x 6 mm thick electrode buried directly in ground (earth pit not less then 2.25 metres deep below ground level ) with top edge of the plate not less then 1.5 metres below normal ground level connected to GI wire 4.0 mm as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of MES schedule Part-I and incl 15 mm bore light grade GI protection pipe (upto 7.5 metres beyond outer edge of earth pit) PCC M-10 grade (Nominal Mix) using 40mm graded stone aggregate in pit with 40mm thick RCC cover in reinforced cement concrete M-15 grade (Nominal Mix) using 20mm graded stone aggregate, reinforced with 8mm dia bar both way @ 150mm c/c, watering arrangement with funnel and wire mesh and 20 mm bore light grade GI watering pipe, common salt and chaarcoal filling, necessary excavation and earth work complete.
GANGA CONSTRUCTION (BID ID -3142936)
JWALA ELECTRIC CONTRACTORS (BID ID -3142253)
KALPAARAV CONSTRUCTION (BID ID -3143154)
B S ENTERPRISES (BID ID -3142844)
Deepak Saxena (BID ID -3143071)
BHARDWAJ CONSTRUCTIONS (BID ID -3141838)
M/S ANIL KUMAR (BID ID -3142115)
Karman Infra Projects (BID ID -3141244)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .