Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.7 CrAccepted-AOC 203 B CHAHBAI BAREILLY UP 243001 | BAREILLY | BAREILLY | UP | 243001 | ₹2.7 Cr | L1 | Accepted-AOC Being L1 and reasonable |
| 2 | L2₹2.8 Cr+₹4.0 L (1.46%)Rejected-Finance 159 SHIV NAGAR MODIPURAM MEERUT 250 110 UP | MEERUT | UTTAR PRADESH | 250110 | ₹2.8 Cr+₹4.0 L (1.46%) | L2 | Rejected-Finance Being other than L1 |
| 3 | L3₹2.8 Cr+₹7.5 L (2.72%)Rejected-Finance | ₹2.8 Cr+₹7.5 L (2.72%) | L3 | Rejected-Finance Being other than L1 |
| 4 | L4₹3.0 Cr+₹29.2 L (10.6%)Rejected-Finance 193 1 CIVIL LINES BAREILLY 243001 | BAREILLY | UTTAR PRADESH | 243001 | ₹3.0 Cr+₹29.2 L (10.6%) | L4 | Rejected-Finance Being other than L1 |
| 5 | L5₹3.2 Cr+₹46.6 L (17.0%)Rejected-Finance | ₹3.2 Cr+₹46.6 L (17.0%) | L5 | Rejected-Finance Being other than L1 |
Tender Value
₹2.4 Cr
EMD Value
₹3.1 L
Closing Date
29 Sept 2021, 6:00 pmClosed
Chief Engineer Bareilly Zone
Headquarters Chief Engineer Bareilly Zone Military Engineer Services Sarvatra Bhawan, Station Road Bareilly Cantt Bareilly - 243001
PROVN OF OTM ACCN FOR INF BDE SIG COY AT SHAHJAHANPUR CANTT
2021_MES_449408_2
CEBZ/BLY/T-04 of 2021-22
Open Tender
Civil Works
Lump-sum
365 days
Shahjahanpur
Please refer Tender documents.
8 documents required · 8 mandatory
₹2,000
GE (E) Bareilly
₹3.1 L
Yes
6 Oct 2021
24 Aug 2021
30 Sept 2021
24 Aug 2021
29 Sept 2021
8 Sept 2021
25 Aug 2021 - 2 Sept 2021
Amount
SCHEDULE 'A' PART-I (BUILDING WORK)
Total amount of SCHEDULE 'A' PART-I (BUILDING WORK) (For details see Item No. 01 of Schedule 'A' Part-I in PDF folder)
Total amount of SCHEDULE 'A' PART-II (INTERNAL WATER SUPPLY) (For details see Schedule 'A' Part-II-A in PDF folder)
Total amount of SCHEDULE 'A' PART-III-A (INTERNAL ELECTRIFICATION) (For details see Schedule 'A' Part-III-A in PDF folder)
SCHEDULE 'A' PART-III-B (INTERNAL ELECTRIFICATION)
Material and labour for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper conductor 2.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathed cable 1100 volts grade, ISI-694 marked with valid CML No. in and including medium grade, PVC concealed conduit and conduit accessories concealed in wall/roof/floor etc, ISI marked with valid CML No.(IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories), with mild steel/pressed steel sunken boxes 1.6 mm thick 65 mm depth with earth dolly duly painted with two coats of anti corrosive paint/aluminium paint over a coat of red oxide primer internally, and two coats of black bituminous paint over a coat of red oxide primer externally, covered with 3 mm thick plastic laminated sheet cover for fixing of switches, sockets etc, including PVC insulated multi-stranded copper conductor 2.5 Sq mm nominal cross sectional area single core cable as earth continuity conductor to common earth and connecting to earth dolly complee all as specified and directed at site for the one 3/5 pin 15/16 amps socket outlet independent compete all as specified and directed:
Material and labour for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper conductor 1.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked with valid CML No. in and including medium grade, PVC concealed conduit and conduit accessories concealed in wall/roof/floor etc, ISI marked with valid CML No.(IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories), with mild steel/pressed steel sunken boxes 1.6 mm thick 65 mm depth with earth dolly) duly painted with two coats of anti corrosive paint/aluminium paint over a coat of red oxide primer internally, and two coats of black bituminous paint over a coat of red oxide primer externally, covered with 3 mm thick plastic laminated sheet cover for fixing of switches, sockets and fan regulators etc, including PVC insulated multi-stranded copper conductor 1.5 Sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed at site for the following:-
(a) One light point controlled by one 5/6 amps one way switch
(b) One ceiling fan point controlled by one 5/6 amps one way switch and one fan regulator
(c) One exhaust fan point controlled by one 5/6 amps one way switch
(d) One Socket outlet, three/five pin, 5 Amp, independent controlled by by one 5/6 amps one way switch or switch/socket combination 5 amps, 5 pin.
(e) One Socket outlet, three/five pin, 5 Amp, controlled by by one 5/6 amps one way switch or switch/socket combination 5 amps, 5 pin. on the same board with other switches, sockets, fan regulators etc.
All as per sl item No 07 herein above but for one light point controlled by two way switches
NOTE FOR ITEM NO. 6.00 TO 13.00 - Switch, Socket outlet etc. shall be measured and paid separately.
Supply and fixing LED bulb 9 watt include connection all as specified. (Make - C & S, Cat ref. CHANDRA 9W/W/B22 / Crompton, Cat ref. LED 9W B22-CDL WW / Havells, Cat ref. LED ADORE 9W B22 WW)
Supply and fixed single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp, 240 Volts all as specified and directed.
Supply and fixing surface and wall mounted LED batten, extruded aluminium housing provided for efficient heat dissipation with polycorbonate diffuser & integrated electronic driver with industrial grade heavy duty driver having THD<10% (study table light fitting LED) suitable for 10/12 W 2' long including tube rod etc. (fixture size: LxWxH in 600x108x62 mm) complete with all accessories in and including connecting up with twin core twisted flexible copper conductor cable with suitable size copper wire complete all as specified and directed. (Make - Havells, Cat ref. ENDURALINEARNEOBS10WLED865SPCWH / Philips, Cat ref. BN 021 LED12S 6500 PSU GR / Wipro (TRIM NEO/LL20), Cat ref. LL20-111-XXX-65NE3*)
Supply and fixing LED surface and wall mounted LED batten, extryded aluminium housing provided for efficient heat dissipation with polycorbonate diffuser & integrated driver with industrial grade heavy duty driver having THD<10% suitable for 4' long T8 20W including tube rod (Double side connection) ultra glass LED tube light with very high efficiency sitable for installation in existing T8 fitting with G13 lamp holder, high lumen output, PF>0.98, neutral white 20 W 4 ft light fitting with lamp etc. complete with all light accessories in and including connecting up with twin core twisted flexible copper conductor cable with syitable size copper wire complete all as specified and directed. (Make - Havells, Cat ref. LUMININEBS20WLED865SPCWH / Crompton, Cat ref. LCTLN-20 CDL / Wipro, Cat ref. WIO0Z1208)
Supply and fix decorative wall mounted light fitting LED bulk head luminarie made up of polycorbonate suitable for 9/15W LED lamp B22 Base complete all as specified and directed. (Make - Havells, LHFOPWEIT21W012(MARS/Apple/Globe)
Supply, fixing, connecting and testing building security light fitting LED 35/36 W with pressure die cast aluminium housing, heat resistant toughned glass, IP 66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device, better potics for uniform distrubusion compete with electronic driver, including connecting up with three core copper conductor cable with 1.5 sqmm size copper wire from ceiling rose to connector of light fitting complete all as specified and directed. (Make - C & S, Cat ref. LTESST36WLED/LS / Havells, Cat ref. ENDURACITYLITEPLATPLUSSL35WLEO757SASYBOPC / Philips, Cat ref. BRP030 LED 35 CW MR PSU GR DX)
Material and labour for fabrication & fixing of GI pipe 'light' grade wall mounting bracket of size 40 mm dia. and 1.50 mtr long fixed to wall with suitable size of nuts, bolts and GI clamps of size 50 x 5 mm as required including fixing of building security light fitting of any watt / any make complete all as specccified and directed.
Supply, fixing , connecting and testing ceiling fan, energy saving, 5 star rated complete without regulator 230 volts single phase 1200 mm sweep energy saving fan including canopy set, down rod and shackle assembly, fan hook including providing three core copper conductor cable of size 1.5 sqmm 3 core from fitting to ceiling rose or connector and writing MES No with black synthatic enamel paint 2.0 cm high complete all as specified and directed. (Make - Havells, Model-Aeroking-50 / Crompton, Model-HS Plus / Orient Model-Energy Star)
Supply, fixing , connecting and testing exhaust fan, energy saving, 3 star rated complete without regulator 230 volts single phase 300 mm sweep metallic body energy saving fan including louvers, shutters, brackets etc. complete accessories including providing/cutting the round hole of required size in wall finishing the same supply and grounting the ragged bolts in wall, fixing the frame on the exhaust side (outer surface of the wall and connecting with and including PVC insulated three core 23/0.0076 copper cable rubber insulated from ceiling rose to exhaust fan motor and writing MES No with black synthatic enamel paint 2.0 cm high complete all as specified and directed. (Make - Havells Ventil Air DS / Crompton, Model-Transe Air reversible / Usha Model-Aeroclean / Crompton- Trans Air)
Supply, fixing , connecting and testing exhaust fan, energy saving, 3 star rated complete without regulator 230 volts single phase 230 mm sweep metallic body energy saving fan including louvers, shutters, brackets etc. complete accessories including providing/cutting the round hole of required size in wall finishing the same supply and grounting the ragged bolts in wall, fixing the frame on the exhaust side (outer surface of the wall and connecting with and including PVC insulated three core 23/0.0076 copper cable rubber insulated from ceiling rose to exhaust fan motor and writing MES No with black synthatic enamel paint 2.0 cm high complete all as specified and directed. (Make - Orient (Hill Air) / Havells (Ventil Air DS / Crompton (Trans Air)
Material and labour for sub main wiring concealed in PVC conduit with approved colour coding as per IS (Red, Black and Green for single phase circuits) with two single core PVC insulated FRLS cable 1100V unsheathed with stranded copper conductor of nominal cross section area as under and drawing into and including PVC non metallic rigid conduit, accessories,of medium grade not less than 25mm dia ,including PVC insulated stranded copper conductor nominal cross section area as under of continuous earth wire complete all as specified and directed.
(a) Two runs of 4 Sq mm as current carrying conductor and one run of 4.0 Sq mm as earth conductor including one run 25 mm or higher dia PVC conduit fixed concealed. Note :- Two run of 4.0 sqmm copper cable, one run of 4.0 sqmm copper cable and one run of conduit shall be measured as one unit.
(b) Two runs of 6 Sq mm as current carrying conductor and one run of 6.0 Sq mm as earth conductor including one run 25 mm or higher dia PVC conduit fixed concealed. Note :- Two run of 6.00 sqmm copper cable, one run of 6.00 sqmm copper cable and one run of conduit shall be measured as one unit.
(c) Four runs of 10 Sq mm as current carrying conductor and two run of 10 Sq mm as earth conductor including one run 25 mm or higher dia PVC conduit fixed concealed. Note : Four runs of 10.00 sqmm copper cable, two runs of 10.00 sqmm copper cable and one run of conduit shall be measured as unit.”
Supply and fixing vertical loadline type TPN DB 4 way, as per IS-8623, IP 43 protection, universal mounting with suitable capacity copper busbar with neutral busbar, earth bar and cable ties for cable management, top and bottom removeable gland plate suitable for mounting MCCB TPN 63/125 Amp as incomer and MCB TP/TPN 32/63 Amp outgoing cables with copper lugs complete with crimping tool complete all as specified and directed.
Material and labour for distribution board double door, for mounting MCBs / isolator, ELCBs etc factory made, confirming to IS: 13032 fabricated out of CRCA sheet not less than 1.2 mm thick fitted with DIN channel, neutral link and 200 Amps rated bus bar. DBs shall be semi glossy finished with epoxy polyester based powder paint sprayed and backed at high temperature, between powder paint process the sheet steel having to go through the anti rust conditioning in not less than seven tank process to ensure smooth finish and protection against corrosion atmosphere. The DBs shall be single door type with hinged door with locking arrangement. The DBs shall be of same make as MCBs /Isolator. DB shall also be provided with label marking indicating the incoming and outgoing circuits on all way as specified. The DBs shall be of IP 42 protection class for the followings.
(a) DB SPN 4 Way (with 200 amps rated busbar double door) 240V
(b) DB SPN 6 Way (with 200 amps rated busbar double door) 240V
(c) DB SPN 8 Way (with 200 amps rated busbar double door) 240V
Supply and fixed MCB SPN 10 KA rating confirming to IS complete all as specified for following ratings.
(a) MCB SPN , 240 volt, 6-32 Amp,
Supply and fixed MCB TPN, complete all as specified for following ratings.
(a) MCB TPN, 415 Volt, 25-32 Amp
Supplied and fixed MCB, 240 Volt single pole, breaking capacity 10KA with "B" Characteristic complete all as specified for following ratings.
(a) 5 to 32 Amps
Supplied and fixed MCCB, 4 pole, 415 V, breaking capacity 16 KA with following capacity complete all as specified and directed at site. (for Incomer in Loadline DB)
Supply and fixing blanking plate complete all as specified and directed.
Material and labour for earthing complete with galvanized steel earth plate electrode size 600x600x6.0 mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanized earth lead 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanized including GI protection pipe light grade 15mm dia connected to main earth wire on pole or control board and GI pipe light grade 20mm dia bore for watering funnel with wire mesh. CI cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 5 connected to earthing test point all as specified or indicated including testing on completion. Note: The unit rate includes for protection pipe and GI earth wire 4.0 mm dia from top of earth plate up to 7.5 meter above ground level.
NOTE FOR ITME No. 45.00: - ON TESTING AFTER COMPLETION OF JOB, IF DESIRED EARTH RESISTANCE (i.e. LESS THAN ONE OHM) IS NOT OBTAINED, THE EARTHING SHALL BE REDONE BY THE CONTRACTOR WITHOUT ANY EXTRA COST TO GOVT.
Supply and fixed rigid non metallic PVC conduits concealed exclusive of boxes (junction/terminals) but inclusive of all Tees, bends elbows, reducers bell mouth tube ends and fixing accessories such as couplers , lock nuts, saddles, pipe hooks etc of external dia size as under :-
Supply and fixing junction boxes (1-4 way) PVC type
Supply and fixed TV Socket -1M, complete all as specified and directed at site.
Total amount of SCHEDULE 'A' PART-IV (SITE CLEARANCE AND EARTH WORK) (For details see Schedule 'A' Part-IV in PDF folder)
Total amount of SCHEDULE 'A' PART-V A ( ROAD & PATH) (For details see Schedule 'A' Part- V A in PDF folder)
SCHEDULE 'A' PART-V B ( ROAD & PATH)
M&L for painting , dashes, arrows, letters etc on roads, pavements and like etc exc by providing 2mm thick thermoplastic hot applying paint of approved make of road marking of approved shade and shape with automated machine adhering of exc 10 cm width complete all as specified and directed.
S&F cat eye reflective type of metal body alloy of size 100 mm x 100mm x 20mm with PAMA striplens reflector of model No DA 972.0 fixed with and including MS stud of suitable size as per manufacturers instructions complete all as specified and directed. Make & Model : (a) Future Vista Mumbai, Item code: 38239027 (b) Jiya Engineering Coy, New Delhi, Item code:78639603 (c) Industrial Hardware Centre, New Delhi, Item Code: 130784281
Supply and fixing solar cat eye aluminium alloy shall (100% water proofing design according to 65) of size 125mm x 125mm x 25mm (shank 65 mm) of high efficiency Mono crystafie solar panel 2.4V /0.3 watt one NI-ed rechargeable battery (1.2V/1600MA) consisting of super bright LED with 10,000 to 18,000 mcd completed as per manufacturers instructions etc all as specified and directed. Make & Model : (a) Future Vista Mumbai, Item code: 32752339 (b) GV Road Safety Products Pune, Item code:SS03 (c) Garg Associates Lucknow, Item Code: RSCE02
Total amount of SCHEDULE 'A' PART-VI A (SEWAGE DISPOSAL) (For details see Schedule 'A' Part-VI A in PDF folder)
SCHEDULE 'A' PART-VI B (SEWAGE DISPOSAL)
Construction of septic tank for 50 users, excavation in any type of soil, PCC 1:4:8 below foundation, brick walls, Base slab, baffle walls and Roof Slab including Vent Shaft, manhole openings with cover connection etc complete all as specified and and shown on Drgs.
Construction of brick masonry soak well of 2.40 m dia and 3.00 m effective depth and excavation in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber in CM, RCC cover slab in M25 / SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats complete shown on drawings all as specified and as directed.
Total amount of SCHEDULE 'A' PART-VII (AREA DRAINAGE) (For details see Schedule 'A' Part-VII in PDF folder)
Total amount of SCHEDULE 'A' PART- VIII A (EXTERNAL ELECTRIC SUPPLY) (For details see Schedule 'A' Part-VIII A in PDF folder)
SCHEDULE 'A' PART-VIII B (EXTERNAL ELECTRIC SUPPLY)
Supply and fixing erecting steel tubular poles in vertical position/as strut poles sewaged 410-SP-55, 11 Mtr long, ISI marked complete with cast iron / M S base plate, finial taper plug, bolts, nuts washers and screws as required duly painted with two coats of aluminium paint over a coat of read oxide primer above ground level, internally and including Planting depth (externally) with two coats of bituminous paint and numbering of poles, black strips etc complete all as specified and as directed at site.
Supply and fixing erecting steel tubular poles in vertical position/as strut poles sewaged 410-SP-31, 9.0 Mtr long, ISI marked complete with cast iron / M S base plate, finial taper plug, bolts, nuts washers and screws as required duly painted with two coats of aluminium paint over a coat of read oxide primer above ground level, internally and including Planting depth (externally) with two coats of bituminous paint and numbering of poles, black strips etc complete all as specified and as directed at site.
Supply, fixing, connecting and testing Street light fitting LED 70 W, new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficient LED as lighting source with toughened glass having IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device, better potics for uniform distrubusion compete with electronic driver complete all as specified and directed. (Make- C&S, Cat Ref LTESST700WLED/LS, / Havells, Cat ref. ENDURALTNERNEOSL70WLED757PASYBOTG / Philips, Cat ref. BRPO 32 LED 70 CWMR PSU GRDX)
Material and labour for drop out fuse unit expulsion fuse single pole upto 25 amps 11000 volts complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick burried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connected to galvanized iron earth strip 32X6 mm by means of bolts nuts check-nuts and washers of galvanized iron or steel as shown in electrical plate No 5 of MES schedule Part-I connecting to earthing test point and testing on completion with including 15mm bore light grade GI protection pipe, RCC 1:2:4 type B1 20mm thick cover reinforced with 6mm thick dia MS bars 3 Nos both ways with lifting hook made out of 6mm dia MS bar, watering arrangement with funnel and wire mesh and 20mm bore light grade GI watering pipe, earthing lead from earth plate to eqipment to point (up to 7.5M long) common salt and charcoal filling, necessary excavation and earth work complete all as specified and directed. Note: The unit rate includes for protection pipe and GI earth strip of size 32 x 6 mm from top of earth plate up to 7.5 meter above ground level.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick burried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connected to galvanized iron earth wire 4 mm dia by means of bolts nuts check-nuts and washers of galvanized iron or steel as shown in electrical plate No 5 of MES schedule Part-I connecting to earthing test point and testing on completion with including 15mm bore light grade GI protection pipe, RCC 1:2:4 type B1 20mm thick cover reinforced with 6mm thick dia MS bars 3 Nos both ways with lifting hook made out of 6mm dia MS bar, watering arrangement with funnel and wire mesh and 20mm bore light grade GI watering pipe, earthing lead from earth plate to eqipment to point (up to 7.5M long) common salt and charcoal filling, necessary excavation and earth work complete all as specified and directed. Note: The unit rate includes for protection pipe and GI earth wire 4.00mm dia from top of earth plate up to 7.5 meter above ground level.
Excavation by Trenchless Tech by Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure.
Design, Supply , Installation, testing and commissioning (CPRI Approved) of factory made and tested outdoor type floor mounted LT panel board, cubicle type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with air insulated PVC sleeved aluminium bus bar of rating 200 Amps for phases and half for neutral installed on porcelain insulators. The panel shall be dust and vermin proof IP-54 class protection and made out of 3.15 mm CRCA MS sheet and 50 X 50 X 6 mm thick MS angle iron frame work ( 450 mm above the ground level and 450 mm below the ground level) and front and back opening with double door type of adequate size for housing LT switchgear and measuring instruments duly powder coated after seven tank process on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size but not less than 4.0 sq mm and comprising of followings:-
(a).Compact air insulated rising main with copper busbar 200 Amps, breaking capacity of 35 KA and IP 54 protection. (b) 4 Pole MCCB ,125 Amp 50 Hz 415 V, With Thermal based Release type Capacity 35 KA -01. (c) 3 Pole MCCB ,63 Amp 50 Hz 415 V, WithThermal based Release type Capacity 25 KA-02. (d) 3Pole MCCB , 32 Amp 50 Hz 415 V, With Thermal based Release type Capacity 10 KA-01 Nos. (e) LED based indicator lamp sets comprising of three colours -01 Set (f) Dual meter Analog(0A -200 V, Digital display, flush mounted 3 phase 4 wire with slector switch including CTs of required capacity (g) Supply and fix time switches 415 V three Phase of 20 Amp rating with contactor fitted inside steel enclosure. (h) Internal wiring with single core copper conductor cable/ PVC Insulated Copper Strip of suitable size incoming to bus bar and bus bar to outgoing MCCB/MCB - 01Job.
(j) Fine wiring with single core copper conductor cable for instruments/indicating lamps - 01 Job. (k) Platform for the feeder pillar board with PCC 1:2:4 15 Cm thick in foundation, Brick (Sub Class B) /Stone/ PCC block work in CM 1:6 ,rendering 1:6 on exposed surfaces and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting blots etc for panel . The platform shall be of 450 mm height above ground level and of adequate size leaving minimum 300 mm all around the feeder pillar board for movements.
Supply, installation, testing and commissioning of transformer step down outdoor type, pole mounted, copper wound, 11KV on HT side and 433 volts on LT side at no load 3 phase 4 wire 50 c/s AC supply of 100 KVA , oil immersed laminated iron core naturally cooled with external cooling tubes, delta connected on HT side and star connected on LT side, corresponding to vector group DYn-11 with neutral brought out separately for earthing, off load, tap changing arrangements up to + / - 7½% with a step of + / - 2.5% with HT cable end box on HT side and LT cable end box on LV side complete with first filling of transformer oil up to appropriate level of desired dielectric strength and complete with standard fittings and accessories confirming to IS-2026 (1180 / 2014) all as specified in particular specifications and as followings :-
(i) No Load Voltage Ratio: 11000/433-250 Volts. (ii) No of Phases: Three (iii) Type of Cooling: ONAN (iv) Frequency: 50 c/s (v) Vector Group: DYn11 (vi) Indoor or Outdoor Type: Outdoor Type (vii) Application of Transformer: distribution (viii) Basic Insulation of Level: 75 KVp (ix) No of Tap position on HV Side (offload & manual operated): 7 (x) Tapping Range: +5% to -10% in steps of 2.5% (xi) Two earthing terminals for body earthing and two additional for neutral brought out on a bushing (xii) Oil Level gauge indicating oil level at minimum, 30oC and maximum operating tempreture (xiii) Rating and terminal marking plates
(xiv) Lifting lugs (xv) Dehydrating Breather with dehyrating agent (xvi) Cable end box - HV & LV side (both with Brass cable glands) (xvii) Percentage Impedence - 4.5%(xviii) Oil temperature indicator and winding temperature indicator (xviii) Oil temprature indicator and winding temperature indicator (xix) Arcing horns/Lighting arrester for HT side - 03 Nos (xx) Thermometer pocket with cap (xxi) Conservator with drain plug and afilling hole (11/4 nominal size thread) with cover (xxii) Drain-Cum-Sampling valve (3/4 nominal size thread, IS 554) preferably steel with plug for three phase transformer. (xxiii) Pressure relief device or explosion vent (xxiv) One filter valve on the upper side of tank
(xxv) Undirectional flat rollers (xxvi) Inspection hole (xxvii) First filling of transformer oil specs as per IS-335 (xxviii) Maximum losses of transformer shall be as per energy efficiency level-3 as per IS-1180 (Part-I) 2014 (xxix) Altitude of installation - 1750 m above MSL Note: (1) The transformer shall be ISI marked with energy efficiency level - 3 category and having BEE certification. Routine and type test certificate (as per IS-2026) shall be produced by the tendered. Certification from BIS and BEE shall be produced against the manufacturer. (2) Any subsequent amendment to IS or Govt notification on the subject shall be assumed as implemented in the schedule mentioned above on the date of supply.
Supply and fix FRP type junction / looping box of size 280 x 170 x 130 mm top hinged with aluminium busbar of 50 Amp rating for phase and neutral on porcelain based insulator, fixed on pole with the help of MS nuts, bolts and MS clamps - 2 nos of size 40 x 4 mm thick with one No MCB SP 6 Amp capacity mounted on din rail inside box, work also includes making suitable hole in pole to take out connections to fitting if required at site complete all as specified and directed.
Supply and fix PVC insulated 3 core 2.5 sqmm, FR PVC Round Sheathed, copper conductor (flexible) industrial cable, 1100 Volt, confirmong to IS 694 for connection of street light fitting from junction / looping box to street light fitting complete all as specified and directed.
Material and labour for fabrication & fixing of building security light fitting LED 70 W with GI pipe 'light' grade wall mounting bracket of size 40 mm dia. and 1.50 mtr long fixed to wall with suitable size of nuts, bolts and GI clamps of size 50 x 5 mm as required compleie all as specified and directed.
Supply and fix cable jointing kit for 11 KV grade (Earthed) cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 50 to 95 sq mm complete all as specified and directed.
Supplying, laying, jointing, testing and commissioning of XLPE insulated screened PVC bedded galvanised steel strip or wire armored electric power cable (Heavy duty ) with aluminium conductor 11000 volts grade, cross sectional area 95 sqmm 3 core suitable for 11KV earthed systems complete all as specified and directed. (Note: 1. Cable may be laid in trenches, under road across the nallah, along poles / walls and in ducts etc. 2. Excavation, earthwork, Sand Cushioning, Cable covers, Pipe for cable protection to be measured and paid for separately.
Material and labour for switch air brake gang operated triple pole mechanically operated mounted on HT insulators (12 insulators type ) and MS galvanized steel frame with operating mechanizing worked from ground level including operating rod for current rating up to 200 Amps 11000 volts complete with locking arrangement MS clamps, bolts and nuts and washers etc including drop out expulsion type of fuses with fuse barrels of required capacity to suit load at site including two coats of aluminum paint over a coat of red oxide primer on MS work complete all as specified and directed. Note: Stack for fixing with poles shall be measured and paid separately.
Material and labour for Non linear resistor type surge arrester (lightening arrestors) confirming to IS 3070 (Part 1) having voltage rating 12 KV, Rated frequency-50 HZ, Nominal Discharge current 10 KA (Heavy duty) complete with all fittings , suitable for 11KV, 3-Phase, earthed distribution system complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 Sqmm 3.5 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 4 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 4 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sqmm 4 core complete all as specified and directed.
Total amount of SCHEDULE 'A' PART-IX A (EXTERNAL WATER SUPPLY) (For details see Schedule 'A' Part-IX A in PDF folder)
SCHEDULE 'A' PART-IX B (EXTERNAL WATER SUPPLY)
M&L for construction of valve chamber 1145 x 1375 x1225 mm internal dimensions, 4 mm thick MS sheet cover with 2 Nos MS hinges welded to angle iron frame of 40mm x 40mm x 6 mm thick with lifting hook and locking arrangement complete with necessary earth work, brick work in CM (1:6), 230 mm thick, PCC bed (1:4:8) type D2 150 mm thick, cement plastering, finishing 15 mm thick in CM (1:4) and applying a coat of black bituminous paint to the steel surfaces all as specified and directed at site.
Supply, installation connecting and testing sluice valve cast iron body (Long Body) class PN 1.6 with flanged ends drilled suitable for bore of pipe 50 mm ISI marked (IS:14846:2000) having brass spindle with iron wheel at top complete with nuts bolts washers rubber gasket etc all as specified and directed.
Total amount of SCHEDULE 'A' PART-X A (SOLAR WATER HEATING SYSTEM) (For details see Schedule 'A' Part-X A in PDF folder)
SCHEDULE 'A' PART-X B (SOLAR WATER HEATING SYSTEM)
Supply and Installation of Solar water heating system ,Flat plate collector type ,with heat exchanger of 200 litre per day capacity ,with electrical heating back up including testing commissioning complete all as specified and as directed.
Supply and Installation of Solar water heating system ,Flat plate collector type ,with heat exchanger of 300 litre per day capacity ,with electrical heating back up including testing commissioning complete all as specified and as directed at site.
Cover plate shall be toughened glass confirming t o IS:12933 (Part-1) -1992 with amendment no 1&2, Collector box shall be made of aluminium sheet, Type , grade, size and finish of material used shall be as per IS:12933 (Part -1) -1992 with amendment no 1&2,. Sheet for absorver shall be made of copper, Type, grade, size and finish of material used shall be as per IS: 12933 (Part -1) -1992 with amendment no 1&2,. Absorber shall be made of copper, Type , grade, size and finish of material used shall be as per IS:12933 (Part-1) -1992 with amendment no 1&2,.Collector box insulation shall confirm to Type , grade, size and finish of material used shall be as per IS:12933 (Part-2, Section V) -1992 with amendment no 1&2, Gaskets and gourmets shall confirm to IS-12933 (Paret-2, Section VI) -1992 with amendment no 1 &2,
(b) Insulated stainless steel Hot water storage tank non pressure type made of stainless steel grade 04 Cr 18 NI or 07 Cr 18 NI of IS 1570(Part 3)-1985, TIG welded of 100 liters capacity, nonmagnetic tank with stainless steel fittings with following specifications - 01 No. Shall be insulated with 40 mm thermal grade PU insulation with FRP Cladding , Tank stand assembly shall be made of angle of size 38X38X4mm duly pretreated and stove enameled with black colour paint
(c) Provisions of electrical back up with minimum 2 KW heating element including providing one no 16 Amps MCB 9 KA rupturing capacity in sub-main distribution board (Catered in schedule of internal electrification) and providing electric connection in rigid non metallic PVC concealed conduit with 4 Sq mm single core, stranded aluminium conductor, PVC insulated wire from outlet of MCB to electrical back up with connected accessories-one job. The solar water heating system shall be provided on roof of single/double storey building. The electrical back up connection shall be tapped from sub main board provided at ground floor. (d) Heat exchanger shall be cage type and make of stainless steel tube of grade 04 Cr18NI or 07 18 NI of IS 1570(Part 5) -1885
(e) All other pipe/civil work, steel staging work for PVC tank, electrical work, outlet and inlet thermometer, Air release valves, check valves gate valves controls and instruments etc all as required shall be deemed to be included in unit rate quoted. System internal piping shall be ISI marked GI pipe medium class of IS:1239 duly insulated with 50 mm thick rock wool of 48 Kg/M3 density and26 SWG Al cladding. Notes: 1. The system shall be tested on completion to ensure that 100/200/300(as specified) liters of water at 60 degree centigrade is available in hot water tank on a normal day in cold season.
2. General purpose overhead tank shall be provided at roof 3 M above roof level as catered for in building drawings and schedule. 3. Normal water pipes and accessories from the normal water over head tank to inlet of plate collector shall be measured and paid for separately. Similarly Hot water pipes from hot water storage tank to bathroom/kitchen shall be measured and paid for separately. 4. Makes: The complete solar water heating system shall be one of the following make: BHEL, TATA-BP SOLAR SYSTEMS, BEST AND CROMPTON (CHENNAI), NOVEL ENERGY(P) LTD, (NEW DELHI), SOLAR EQUIPMENT MANUFACTURING CO.(NOIDA), SOLCHROME SYSTEMS INDIA LTD(PARWANOO-HIMACHAL), SURYA JYOTI DEVICES INDIA LTD (ROPAR-PUNJAB)
SCHEDULE 'A' PART-XI (COOLING APPLIANCES)
Supply, installation, commissioning of Water cooler fully stainless steel, electric driven single phase having approx storage capacity of 80 litre and nominal cooling capacity of 40 Litres per hour complete all as specified and directed.
Supply and fix refrigerator, electric driven (single phase), capacity 195 Litres .BEE 3 star rated complete all as specified and directed. Note 1 : If the 195 ltr Cap is NA in market, the Higher cap of refrigarator is accepted for the same quoted rate by the contractor.
Supply and fix voltage stablizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 170V to 250 V with out put voltage stablized at 230 V with accuracy of +2.5% and capacity 2 KVA suitable for above water cooler complete all as specified and directed.
Total amount of SCHEDULE 'A' PART-XII 'A' (DESERT COOLER) (For details see Schedule 'A' Part-XII in PDF folder)
SCHEDULE 'A' PART-XII B (DESERT COOLER)
Supply and installation of desert cooler electric driven (single phase), having nominal air flow capacity of 4000 CuM per hour (or nearest size).made out of 1.6mm thick GI sheet including opening door shutter three side with two Nos door handle and tulu pump and other accessories and making connection of water supply system complete all as specified and as directed.
Arun Construction Co.
M/s DS Enterprises
Sudhir Sharma Associates
TEAM ACC INFRABUILD PRIVATE LIMITED
yash enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .