Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Not Admitted-Fee/PreQual/Technical A 604 A SUSHANT LOK I GURGAON GURGAON GURGAON HARYANA 122009 | GURUGRAM | HARYANA | 122009 | Not Admitted-Fee/PreQual/Technical Others-Documents submitted by the agency are not as per NIT hence not admitted |
| 3 | Not Admitted-Fee/PreQual/Technical TEHSIL BHORANJ VILLAGE SAMMU BHORANJ ROAD DISTT HAMIRPUR HP 176045 | HAMIRPUR | HIMACHAL PRADESH | 176045 | Not Admitted-Fee/PreQual/Technical Others-Documents submitted by the agency are not as per NIT hence not admitted |
Tender Value
Refer Docs
EMD Value
₹27,930
Closing Date
14 Apr 2025, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE(E) Shimla
Block no. 35 SDA Complex Kasumpti Shimla
RC for PITC of AFD and FA system at various buildings of Hamirpur
2025_BSNL_231920_1
02/EE/E/BSNL/ED/ETENDER
Open Tender
Electrical Works
Item Rate
30 days
SHIMLA
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
AO (Cash), O/o GMTD Shimla
₹27,930
5 May 2025
3 Apr 2025
15 Apr 2025
3 Apr 2025
14 Apr 2025
3 Apr 2025
Amount
Supplying, Installation, Testing and Commissioning of following zone micro processor based MAIN Fire control panel suitable for wall/floor mounting fabricated from 16 SWG CRCA sheet along with sealed maintenance free battery as secondary power source, power supply & battery charger etc. of capacity to take care of standby power supply inbuilt PA system. The necessary talk back facility between panels shall be incorporated in the panel itself complete with telephone hand set & necessary hardware & software etc. as required. (BSNL Approved make)
12 Zone a/w upto 12 speaker circuit (8 ohm/4 watt) 60 watt P.A Facility
8 Zone a/w upto 12 speaker circuit (8 ohm/4 watt) 60 watt P.A Facility
6 Zone a/w upto 12 speaker circuit (8 ohm/4 watt) 60 watt P.A Facility
SITC of following zone solid state microprocessor based LOCAL Fire control panel, wall mounted type fabricated from 16SWG CRCA sheet incorporating audio And visual indications for each zone, complete as per specification attached. (BSNL Approved make)
Supplying, Installation, Testing and Commissioning of following detectors complete with builtin LED and base of detector etc as required as per specification attached. The base shall be of same make as that of detector. (BSNL Approved make)
Photo Electric Smoke Detector
Ionisation type Smoke Detector
Heat detector operating at 54C/57°C with rate of rise cum fixed temperature (Dual Thermistor type)
Supplying, Installation, Testing and Commissioning of response indicators made of 16SWG MS sheet. The response indicator box should have a provision for conduit entry from one side and terminal strip fitted for connection. The response indicator shall lit by means of twin LEDs in Red colour. The indicator should have a screw type cover and suitable for operation loaded lamps etc as required and entire unit of the same make as of control panel.
Supplying, Installation, Testing and Commissioning of manual call point (pillbox) using push button in red colour. The box made of thickness not less than 16SWG CRCA sheet of size 100mmx100mmx55mm deep with fire red finishing the front should be sealed by means of breakable glass and should be dust & vermin proof. The push button should have a pair of NO/NC contract and provision for LED.
Supplying, Installation, Testing and Commissioning of electronic hooter cum speaker enclosed in 16 SWG MS enclosure of suitable size painted with fire red shade etc.and compatible with the Fire Panel and as per specifications attached.
S/F of following sizes of steel conduit along with the following accessories in surface/ recess including painting in case of surface conduit or cutting the wall and making good the same in case of recessed conduit as reqd. (suitable size of MS box will be provided where ever detectors are to be fixed in surface conduit)
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
2x1.5 Sq. mm
3x1.5 Sq. mm
4x1.5 Sq. mm
Supplying and Fixing following sizes PVC insulated PVC sheathed FRLS copper conductor single core XLPE armoured cable on wall/cable tray as required.
2x1.5 Sq. mm
3x1.5 Sq. mm
4x1.5 Sq. mm
Supplying and fixing of following type fire extinguishers including hanging hooks as per the specification etc complete as required. (M/s Safex/ Cease fire / Monark / Firex/Safeguard or Similar superior make)
4.5 Kg CO₂ type extinguisher with hose & ready to use.
6KG ABC Powder Type (Stored Pressure) for Class 3A type of fire filled with MAP Powder with hose ready to use.
Supplying & Fixing Photo Luminescent non toxic, non-radioactive maintenance free self glowing exit signs comprising zinc sulphide chargeable crystals which glows in dark printed on u-1000 photo luminescent containing luminescent I I I as base chemical cover with u/v stabilized coating and mounting arrangement for wall/ceiling mounting as per site conditions the colour combination and size of the letters shall be as per IS: 12349 amended up to date for 4mm acrylic Double side 12"x 6".
Supplying & Fixing Photo Luminescent non toxic, non-radio active maintenance free self glowing exit signs comprising zinc sulphide chargeable crystals which glows in dark printed on u-1000 photo luminescent containing luminescent I I I as base chemical cover with u/v stabilized coating and mounting arrangement for wall/ceiling mounting as per site conditions the colour combination and size of the letters shall be a per Is: 12349 amended up to date for 4mm acrylic Single side 12"x 6".
Supplying and fixing Laminated mimic diagram of size 2'X2'/ 2x1.5' (Size as per space available at site) indicating all zone etc as required.
Supplying and fixing Laminated mimic diagram of size 1'x1' indicating all zone etc as required.
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .