Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.4 LAccepted-AOC | L1 | Accepted-AOC Lowest amount quoted | |
| 2 | L2₹53.3 L+₹2.3 L (4.48%)Rejected-Finance H NO 2702 JHANDA CHCOWK PURANI BASTI RANJHI JABALPUR M P 482005 | JABALPUR | MADHYA PRADESH | 482005 | L2 | Rejected-Finance Highest
amount quoted |
Tender Value
Refer Docs
EMD Value
₹99,700
Closing Date
2 Apr 2022, 6:00 pmClosed
Shri Dhiraj Kumar, IDSE, EE
Garrison Engineer (East), Near COD Estate, Ranjhi, Jabalpur (MP)-482011
As per BOQ
2022_MES_511423_1
8408/E8
Open Tender
Civil Works
Item Rate
240 days
Garrison Engineer (East) Jabalpur
D a(i)
7 documents required · 7 mandatory
₹500
Garrison Engineer (East) Jabalpur
₹99,700
Yes
29 Apr 2022
4 Mar 2022
4 Apr 2022
4 Mar 2022
2 Apr 2022
18 Mar 2022
4 Mar 2022 - 11 Mar 2022
Amount
Demolation of brick or stone /boulder masonry built in CM or cement lime mortar including all quions, arches, pillars etc, but excluding ashlar fecings, dressed stone work & precast concrete articles complete all as specified and directed.
Demolation of PCC of any description & in any position not otherwise specifically provied for (unreinforced) including removal of debries as directed by Engr-in-Charge.
PCC (1:3:6) type C-2 using 40 mm graded crushed stone aggregate as in foundation & mass concrete.
RCC design mix M-30 using 20 mm graded crushed stone aggregate in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete.
RCC design mix M-30 using 20 mm graded crushed stone aggregate Walls,retaining walls, basement walls and the like ant thickness , above top of footings including attached pilasters and buttresses and Incl water bar as specified and joints inside walls shall be provided AS Per IS 3370 Part-I to IV. Note. Water bar shall be measured and paid seperately under relevant item.
S&F 150 mm width POLYVINYL CHLORIDE water bars providing as per IS 3370 (Part 1) : 2009.
Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finished curved surfaces of concrete.
Formwork to faces of walls, retaining walls, abutments, parapets & staircase railing and similar work including attched pillasters,buttresses etc: vertical or to better rough finished curved surfaces of concrete.
TMT HYSD reinforcement bars 10 mm over dia including all cutting bending binding cranking placing & binding with MS wire (annealed) not less than 0.90 mm dia complete all as specified and directed. Note :- Design Static tank shall be got done by the contractor duly vetted by Government Engineering College/NIT and the cost of the same is inluded in quoted rates.
TMT HYSD reinforcement bars 5 mm dia and over upto and incl 10 mm dia in stirrups, spacers and binders.
M&L for two coat plaster, first coat 12 mm thick and next 10 mm thick on concrete surface in CM 1:3 with intergal WPC, finished fair& even surface complete. Note. (i) Intergal WPC paid seperaitly. (ii) The second coat should be Applied after allowing for first coat to harden.
Supplying only inergral water proofing compound (ISI Mark).
Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering as directed by Engr-in-Charge.
Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface.
M&L for 100 mm thick PCC type D-2 (1:4:8) using 40 mm graded crushed stone aggregate.
M&L for 40 mm thick PCC type B2-2 (1:2:4) using 20 mm graded srushed stone aggregate.
Forming Construction joints joint 30 mm deep x 10 mm wide filled with sealing compoud complete all as sepicified and directed.
M&L for forming 20 mm thick expansion joints filled with preformed bituminous filler and top 30 mm primed and sealed with compound Grade 'A' complete all as sepicified and directed.
S&F for Aluminium Stairs (framed) including stringers, treades, landing, balusters, hand rails etc. including cleats, brackets, etc.complete all as specified and directed.
Applying evenly a black bitumen in outer side surface of concrete of in dustrial bitumen 85/25 at the rate of 1.2 Kg per sqm etc.complete all as specified and directed.
Preparation of new plastered or un-plastered surface and applying three coat of white wash on walls complete all as specified and directed.
Dismantling posts or struts (wood, steel or RCC) embedded in PCC etc any section, including taking out embedded portion and making good disturbed ground complete all as specified and directed.
Dismantling of fencing wire mesh, concertina coil of any type complete all as specified and directed.
M&L for PCC in type B1(1:2:4) 20 mm aggregate as in copings including necessary form work.
Dismantling of stone/boulder masonry, built in CM or cement lime mortar including all quions, arches, pillars etc, including ashlar facings, dressed stonework & precast concrete articles complete all as specified and directed.
M&L for random rubble walling, brough to course, well bonded, bedded and solidly hearted built in CM (1:6).
M&L for random rubble walling, brought to course, well bonded, bedded and solidly hearted built in CM (1:6) except stone.
S&F hand rails, half round or other stock section or core for wooden hand-rail straight protion, drilled & countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete & screwing etc wind ties for roof including securing bolts; posts & struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc; flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting, etc & similar work conforming to Fe 290-O-Gde E-165 complete all as specified and directed.
Fixing only in repair Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled & countersunk for balusters running bars, for doors,balusters,nosing to steps including embeding in concrete & screwing etc. wind ties for roof including securing bolts; posts & struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., & similar work conforming to Fe 290-0 Gde E-165.
Fixing only chain link MS galvanised fencing of any size with GI wire including line wires of any mesh, size and type to any type of standards, rails, straining bolts, etc including provision of binding wire complete all as specified and directed.
Supply only chain link MS galvanised fencing mesh, size and type to any type of standards, etc complete all as specified and directed.
S&F in repair for galvanised 2 strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossings with and provision of galvanised mild steel wire staples or steel pins etc complete all as specified and directed. (Each line wire to be measured).
M&L for preparation of new or previously untreated surfaces of steel of any description, n exc 10 cm in width or girth any apply two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L in repair for Galvanised 2 strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia barbed with 2mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts including, securing or tying at crossings with and provision of galvanised mild steel wire , staples or steel pins etc as directed (each line wire to be measured ) complete and all as specified and directed by Engr-in-Charge.
Dismantling structural steel work including doors, gates but excluding framed truss etc.
S&F Rolled mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc complete, drilled for fixing of steel sheeting or other covering, doors etc to be prepared for hanging or sliding with & including either hooks & hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails & guides) & hanging; also fastening & fixing complete GDE Fe410-O or Fe310-O.
Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required; hooks (stay), heavy, for large gates; hook & pintel hinges; large hasps & staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trussers or rafters; knee piece inserts; two way & three way straps, plate washers & similar small articles conforming to Fe290-O Gde E-165.
Excavating in trenches, n exc 15 m wide & n exc 1.5 m in depth; for foundation etc or for shafts, wells, cesspits, manholes, pier holes, etc n exc 10 sqm on plan & getting out in soft/loose soil.
M&L for PCC in foundations, filling and mass-concrete type D2 (1:4:8) using 40 mm graded crushed stone aggregate asin sub base.
M&L for RCC in foundations, filling and mass-concrete type B1 (1:2:4) using 40 mm graded crushed stone aggregate.
M&L for RCC type B1 (1:2:4) using 20 mm graded crushed stone aggregate in columns, pillars, piers, posts and struts.
M&L for mild steel TMT bars 6-8mm dia & over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality conforming to GD-I. IS-432 (Part I).
Returning, filling in, including spreading, levelling, watering & well ramming in layers n exc 25 cm in soft/loose soil.
Removing excavated soil n exc 50 m & depositing where directed at a level n exc 1.5 m above the strating point.
Demolition of reinforced Cement concrete of any description & in any position not otherwise specifically provided for (reinforced).
M&L for raised pointing to random or polygonal rubble, uncoursed or brought upto courses in m cement mortat (1:4) all as specified and directed.
Form work to sides of pillars, posts, struts, piers, columns and stanchions rough finished surfaces of concrete square, rectangular or polygonal
Separating, scrapting & cleanding of reinforcement (Demolition of concrete measured separately).
Supply only Mild steel round bars 10 mm dia & over, cut to length, as in stiffners in chaink link fencing as specified and directed by Engr-In-Charge.
Demolition of reinforced Cement concrete of any description & in any position not otherwise specifically provided for (unreinforced).
M&L for type 1:2:4 using 16 mm aggregate as per IS 383 Precast cement concrete block masonry exc. 10 cm in wid th and setting in mortar complete width and setting in mortar complete.
Supply only Mild steel screw bolts (machine made) dia 5 to 10 mm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square not exceeding 5 cm.
S&F Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks & similar work conforming to Fe 290-0 Gde E-165.
Schedule of credit amount of Rs. 1,60,884.00 to be deducted during AOC.
R R VISHWAKARMA CONSTRUCTION CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .