Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.3 LAccepted-AOC | ₹28.3 L Quoted ₹29.7 L | L1 | Accepted-AOC Lowest |
| 2 | L2₹30.5 L+₹82,765 (2.79%)Rejected-Finance | ₹30.5 L+₹82,765 (2.79%) | L2 | Rejected-Finance Higher |
| 3 | L3₹30.6 L+₹87,650 (2.95%)Rejected-Finance HOUSE NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR PB 144022 | JALANDHAR | JALANDHAR | PUNJAB | 144022 | ₹30.6 L+₹87,650 (2.95%) | L3 | Rejected-Finance Higher |
| 4 | L4₹30.7 L+₹98,845 (3.33%)Rejected-Finance | ₹30.7 L+₹98,845 (3.33%) | L4 | Rejected-Finance Higher |
| 5 | L5₹31.0 L+₹1.3 L (4.39%)Rejected-Finance 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | ₹31.0 L+₹1.3 L (4.39%) | L5 | Rejected-Finance Higher |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
23 Mar 2021, 6:00 pmClosed
GE NAMS
GE NAMS KHASA CANTT AMRITSAR
REPAIR/MAINT OF UG CABLE AND ALLIED WORK IN TECHNICAL AREA AT NAMS
2021_MES_427421_1
GE NAMS - 91 / 20 - 21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
NAMS CANTT
Class D
Category b i
6 documents required · 6 mandatory
₹500
Yes
GE NAMS
₹80,000
Yes
31 Mar 2021
3 Mar 2021
24 Mar 2021
3 Mar 2021
23 Mar 2021
17 Mar 2021
Amount
M & L in replacement for air break gang operated triple pole mechanically operated mounted on HT insulators and galvanised steel frame with operating rod of 25mm bore medium grade GI pipe suitable for operation while standing on ground for current rating 200 Amps suitable for 11000 volt 50 Hz supply including 12 insulator and drop out fuse carrier element all as specified and directed by Engineer-in-charge.
Supply & fixing in replacement of lighting arrestor metel oxide type gap less hreavy duty single pole suitable for rated wsystem on voltage 12 KV and working rated 9 KV normal discharge.
Opening up the top cover of the servo voltage stabilizer by taking out the transformer oil in a separate container after disconnecting/taking out the In/Out side electric connections from both the primary & secondary side of the servo voltage stabilizer of any type/ description (indoor type ) installed in Power house for carrying out necessary repair/rewinding or any other repair as required after shifting the stabilizer to contractor's work shop including taking out complete core assembly, Magger the winding for identifying the fault/defective winding, seggregating the defective winding portion/taking out, cleaning the laminated core rewinding with appropriate gauge winding wire of existing description for servo voltage stabilizer of capacity 200 to 315 KVA including assembling & testing on completion & installation the same at the site all as specified and directed by Engr-in-charge. Note : (i) Winding of coil and spares required as per repair shall be measured and paid separately under respective items. (ii) The transpotation charges and taking down/taking up and returning to site of servo voltage stabilizer are inclusive in the quoted rates. (iii) The cost for the dehydration of transformer oil if reqd shall be measured & paid separately. (iv) The cost of insulation material such as paper, cotton tape , latheroid sheet , casl sheet etc are inclusive in the quoted rate. (v) servo voltage stabilizer shall be returned duly repaired within 15 days failing a penal recovery (Lump Sum) of Rs 5000/- shall be made from contractor's dues.
Supply and replacement of LT coils made out of super enameled LT copper strip of servo voltage stabilizer capacity 200 to 315 KVA(Note coil to be replaced shallhave same number of turns,gauge,insulation value matching with manufactures design
Supply and replacement LT 430V bush rod suitable for 200 to 315 KVA servo voltage stabilizer complete with brass stud, brass nuts, brass cup and packing gasket complete all as spd and directed.
Rubbing/scratching old paint of servo voltage stabilizer/transformer of capacity 200 to 315 KVA, through cleaning with kerosene oil and providing two coats of metallic paint including writing MES No on Transformer body with black paint complete all as specified and directed.
Cleaning, dehydration/ reconditioning of transformer oil different location by dehydration plant including testing as per IS Specification and result not less than 40 KV at site, complete all as specified and directed by Engineer-in-Charge.
Supply laying & testing in replacement cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (Heavy duty) LT 1100 volt grade with stranded aluminium conductor of size 10 sqmm 4 core complete all as specified and directed.
All as per srl item No 9.00 here-in-before but of size 10 Sqmm 2 core.
All as per srl item No 9.00 here-in-before but of size 25 Sqmm 4 core.
All as per srl item No 9.00 here-in-before but of size 16 Sqmm 4 core.
Supply,laying & fixing double wall corrugated (DWC) pipes made of high density polythyline (HDPE) with all accessories i.e. all type of joints,Sockets,Elbows,bends and End caps etc.. of size 77mm outer dia and 63mm inner dia for LT UG cables sizes all as specified and directed by Engr in Charge.
Supply and fixing in replacement APFC relay 8 stage with single CT input power factor control relay with internal wiring complete all as specified.
Supply and fixing in replacement (Colour RYB) Neon indicator as per existing LT Panel/Capacitor Panel/Servo stabilizer complete all as specified.
Supply and fix in replacment capacitor duty contractors (CDC) as per existing type suitable for 10KVAr APFC panel including complete internal wiring all as specified and directed by Engr-in-charge.
Supply and fixing in replacement shunt capacitor 10 KVA with internal wiring complete all as specified.
Supply laying & testing in replacement cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (Heavy duty) LT 1100 volt grade with stranded aluminium conductor of size 70 sqmm 3.5 core complete all as specified and directed.
All as per srl item No 18.00 here-in-before but of size 50 Sqmm 3.5 core.
All as per srl item No 18.00 here-in-before but of size 95 Sqmm 3.5 core.
S & F in replacement straight through/end termination joint cold shinkable of any size suitable for 3 core 11000 volts XLPE HT UG cable of size 70 Sq mm to 185 Sq mm complete all as specified and directed.
Exacavates and relaying cables loops near the poles LT Panels,LT Pole & transformers, cutting the damages/burnt parts of cable and reconnecting its positions complete with thimbles, nut bolts, sleaves all as specified and directed by Engineer-in-Charge.
S & F in replacement of MCCB Capacity 36 KA 3 pole 400 Amps thermal megnate to release type with preader and aluminium lugs all as required at site.
All as per item 23 here in before but 315 Amp 25 KA
All as per item 23 here in before but 200 Amp 25 KA
Material and labour for preparing old painted surface of panel board by cleaning removing of old paint by scratching with wire brush / sand paper etc and including denting of broken / rusted surface and applied two coat of synthetic surface enamel paint by spray painting outside surface of panel as existing colour of panel all as specified and directed.
Material and labour for repairing existing LT Panel doors of front , back and internal sheets complete with new locking arrangement complete all as specified and directed. Note: Any part/spare found defective such as packing, nuts bolts,hinges & (welding machine works) etc shall be repaired/replaced which cost shall be deemed to be included in the unit rate quoted for this item.
Excavation in trenches not exceeding 1.5m wide & not exceeding 1.5m in depth for and getting out in any of soil complete all as specified and directed.
Returning, filling including spreading, leveling, watering and well ramming in layers not exc 25 cm thick all as specified and directed.
Removal of surplus excavated soil to a distance not exc 50m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified
Supply laying & testing in replacement cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (Heavy duty) LT 1100 volt grade with stranded aluminium conductor of size 300 sqmm 3.5 core complete all as specified and directed.
All as per srl item No 31.00 here-in-before but of size 240 Sqmm 3.5 core.
All as per srl item No 31.00 here-in-before but of size 185 Sqmm 3.5 core.
M & L in replacement galvanised pipe 80mm bore light grade fixed to pole with clamps nuts, bolts and washers or laid under road crossing or fixed to wall complete all as specified and directed.
M & L in replacement galvanised pipe 100mm bore light grade fixed to pole with clamps nuts, bolts and washers or laid under road crossing or fixed to wall complete all as specified and directed.
M&L for Pre stressed concerete pole in replacement 9 mtr long of cross section of 102mmx 172mm at top and 102mm x 279 mm at bottom class 10 complying with requirement of IS-1678-1978 including painting of poles woth two coats of synthetic paint in black & white step each upto 1.5 mtr high from coping over a coat of primer including numbering of poles as directed.
M & L in replacement of out door type aluminuam bus bar chamber feeder box of cap 300 Amp , 3 phase, 4 wire, 415 Volts with porcelain insulator of size 90 x 60 x 45 cm made out of 3.15 mm CRCA Sheet duly painted with two coats of synthetic enameld paint over a red oxide primer and fixed and supported with anlge iron grouted in PCC 1:2:4 upto 0.30 mtr high from ground level all as directed by Engr-In-Charge.
Supply laying & testing in replacement cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (Heavy duty) LT 1100 volt grade with stranded aluminium conductor of size 120 sqmm 3.5 core complete all as specified and directed.
Supply and fixing in replacement flood Light Luminaire 120 watt with .high power SMD LED cool white,CRI 75,+/- 5% supply voltage 220/240/50 Hz, light engine driver base.pole adapter, pressure die cast LM6 diffusor:injection model polycarbonate, powdre coated in IP 66 Incliding protection over temperature complete all as specified and directed.
Supply and fixing in replacement flood Light Luminaire 150 watt with .high power SMD LED cool white,CRI 75,+/- 5% supply voltage 220/240/50 Hz, light engine driver base.pole adapter, pressure die cast LM6 diffusor:injection model polycarbonate, powdre coated in IP 66 Incliding protection over temperature complete all as specified and directed.
Supply and laying or fixing in replacement 1100 Volts grade heavy duty cable with PVC insulated aluminium standard conductor served with an inner sheathing of PVC tape and over all PVC Sheathed one twin core 10 Sqmm cable standard conductor cable flat or circular all as specified and directed by Engineer- in- Charge.
Supply and laying or fixing in replacement 1100 Volts grade heavy duty cable with PVC insulated aluminium standard conductor served with an inner sheathing of PVC tape and over all PVC Sheathed one twin core 6 Sqmm cable standard conductor cable flat or circular all as specified and directed by Engineer- in- Charge.
Taking out carefully manually by excavation of existing cable with loops and relaying with DWC pipe the same after repair of cutting the damages / burnt parts of cable and reconnecting its into original positions complete with cable joints all as specified and directed by Engineer-in-Charge.Note:-(i) LT Cable Joint & DWC Pipe will be measured and paid sepearetly. (ii) Unit rate shall be included in excavation and returning filling.
Material and Labour straight through joint heats shrinkable suitable for upto 95 sqmm LT 3.5 core 1100 volts XLPE cable type complete all as specified and directed.
Material and Labour straight through joint heats shrinkable suitable for 120 sqmm to 300 sqmm LT 3.5 core 1100 volts XLPE cable type complete all as specified and directed.
Supplyand fixing in replacement of MCB single pole 6 to 32 Amps all as specified and directed
S & F in replacement of MCB 40 amps single pole with neutral, AC 230 volts complete all as specified and directed.
S&F in replacement of GI strip 32 mm x 6 mm buried In ground complete all as spd and directed
Earthing complet with galvanised steel earth plate electrode 60cmx60cmx6mm thich burried directely in ground vertically to adepth not less than 2.25m below ground level with top edge of earth plate at a depth not less than 2.25m below ground level connected with an including GI Strip 32mmx6mm by means of nuts and bolts , check nuts, washers of galvanised iron and thimbles, earth plate surrounded by picked layers of coal, dust and common salt 15cm thick all around top and bottom and watering , excavation, earth work PCC Chamber in cement concrete 1:3:6 type C-2 and RCC Cover in M-20(design mix) complet all as shown in Electric plate No.5 of MES Standerd schedule of rates (Part-I) of 2009 complet all as specified and directed and testig on completion. Note(i) Unit rate shall be included for protection pipe, GI water pipe wire mesh funnel excavation , RCC pit cover , test point, 32mmx6mm GI Strip top of earth plate upto 5m above ground level and if GI Protection is less than 5m no price adjustment shall be made (ii) PCC Pit shall be provided at least 500mm away from the earth pit and extra cost of additional length of water pipes and fittings, junction elbowetc. Shall be deemed in inclusive.
Supply, Install in replacement factory made CPRI approved outdoor type dust and vermin proof feeder Pillar LT Panel board cubicle double door hinged type of suitable size 415V AC, 50Hz, fabricated of GP/CRCA sheet 3mm thick machine pressed and angle iron frame 50mm X 50mm X 6mm grouted in PCC 1:2:4 type BI (20mm grade stone aggregated) powder coated in Nine Tank process inside and outside complete including 4 Pole aluminum Bus Bar of suitable size mounted on porcelain insulator ,concealed hinged door with 3Positioning door locking arrangement and enclosed in chamber made out of 2mm sheet thick GP/ CRCA sheet machine pressed and connection from incoming and outgoing electric cable with suitable size thimbles/lugs cable gland with open able shutters on both side and comprising of following as per item 51.00
(i)MCCB 200 Amps 35KA 4pole with microprocessor release adjustable type of as a incomer-01 (ii) MCCB 25 KA TPN 100Amp -01 (iii) MCCB 16 KA TPN 63A -03 (iv) Aluminium Busbar of 300 Amps 3 phase+Nutral with insulated (v) Digital Ammeter and volt meter of suitable size Note:- Existing Old/Unserviceble Panels including accessories are removed and deposit to MES Store yard by the contractor from his own arrangement without any extra cost.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine for road crossing GI tubing of any size for cable protection complete all as specified and directed.
Supply and fixing in replacement of HT underground cable XLPE insulated PVC bedded, galvanised steel strip armoured electric power cables (heavy duty) with stranded aluminium conductor 11000 volts grade cross sectional area 120 sqmm 3 core laid in duct / trench/along pole etc including making connection complete all as specified and directed.
Supply and fixing in replacement of sheet steel enclouser distribution boards, double door factory made TPN Vertical 4 way 3 phase 415 volts 4 way with 200 amps rating copper bus bar and PVC insulated copper jumpers of suitable size from the MCCB to the out going circuits one incoming MCCB and 12 outgoing MCBs circuits comprising of 3 phase 4 wire of suitable rating complete all as spcd and directed with the following accessories :- (a) MCCB 100 amps, 25 KA, TP, 415 volts, 50 Hz = 01 No. (Note:- Out going MCB shall be measured and paid for separately)
M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth lead wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade) and watering pipe 20 mm bore GI pipe (light grade ) and chamber of pcc 1:4:8 type D2 using 40 mm graded stone aggregate and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 5 of SSR PART 1 , with charcoal dust and salt complete and earth lead connected to earthing test point (up to main switche, DBs) complete all as specified & testing on completion.
Supply and fixing in replacement of sheet metal enlosure for DBs when MCBs to be used double door factory made flush fixed complete with 100 amps rated bus-bar 240 volts single phase 6 ways including necessary brick work and plaster to match with the existing surface complete all as specified.
Supply and fixing in replacement of sheet metal enlosure for DBs when MCBs to be used double door factory made flush fixed complete with 100 amps rated bus-bar 240 volts single phase 8 ways including necessary brick work and plaster to match with the existing surface complete all as specified.
Servicing of HT VCB 11KV,630A of Kirloskar make alongwith tripping system and testing of vaccum circuit breaker 11KV, 630A, 25KA including taking out Breaker/trolley and carried out the fwg repair/tests made for smooth operation (a) Cleaning and greasing of mechanism- 01 Job (b)Tightning testing of mechanism parts- 01 Job.(b)Tightning testing of mechanism parts- 01 Job.(c ) Alignment testing and adjustment of mechanism- 01 Job.(d) Operation, testing of trip and close electrical and manual mode- 01 Job.(e) Spring charging testing electrical and manual mode- 01 Job.(f) Cleaning of panel insulater CT &PT unit- 01 Job.(g) Cleaning and tightning of control/wiring CT &PT unit- 01 Job.(h) Cleaning and testing of relay with current injection method- 01 Job.(j) Testing of auxillary relay - 01 Job.(k) Allingment of trolley, checking/greasing of shutter /lock of breaker Note :- (a) Service will be carried out through any reputed Manfacturer authorised (ie L&T, Schenieder,CG,Kirloskar & ABB) Service Engineer only. (b) The cost of minor spare parts i.e nut and bolts, springs, grommets, dust cover, ring of isolator contacts, clips, pin for release prop, 'Y' Phase shround, over ride stop pin etc. unless or otherwise mentioned here-in-after but essentially required to make the panel serviceable shall be deemed to be included in the quoted rate.
Supply and fixing in replacement CT unit 100/50/5A, 15 VA 50Hz suitable for 11KV VCB.
Supply and fix spring charging electric motor suitable for kriloskar VCB of cap 630 Amp with complete accessories as per existing.
Supply and fixing in replacement of 11KV support insulator suitable for 11KV VCB dismantling and mantling of VCB Panel labour charge,high quality 11KV VCB busbar Insulation Material and Nutbolts included in quoted rates complete all as specified
Supply and fixing in replacement RYB indicator suitable for 11KV VCB complete all as specified.
Supply and fixing in replacement of Amp meter suitable for 11KV VCB DM 3 252 complete all as specified.
Supply and fixing in replacement of volt meter suitable for 11KV VCB DM 3 251 complete all as specified.
Supply and fixing in replacement Earth fault relay instant under voltage relay/over voltage relay complete all as specified.
Supply and fixing in replacement trip coil assembly 24V DC complete all as specified.
Supply and fixing in replacement of Breaker control switch of 11KV VCB for charging/discharging complete all as specified .
Supply and fixing in replacment of HRC Fuse cap 4 Amp to 10Amp suitable for 11 KV VCB DC Circuit all as specified and directed by Engr-In-charge.
S&F DC Power back min 2Hrs battery backup 24V DC including charging equipment suitable for 11KV 800Amp VCB operting system complete all as specified .
Material and labour for PCC 1:4:8 type D-2 using 40mm graded broken stone aggregate as in mass concrete in foundation of poles complete all as soecified.
M & L in replacement cross arms bracings supports clamps and back plates fabricated from structural steel sections including nut bolts washers welding bending cold and hot drilling holes for bolts in any shape or size as indicate or directed and inclusive of one primer coat one under coat and one finishing coat of paint.
Supply and fill up transformer oil topping up having dielectric strength not less than 40 KV at 4 mm gap conforming to IS complete all as specified and directed.
All as per srl item No 73 here-in-before but of of size 50mm outer dia and 38mm inner dia for LT UG Cable
Material and labour for sand cushioning with a layer of fine sand 8 cm thick before laying the cable and 15 cm after laying the cable in trenches to cover under ground cable complete all as specified and directed. Note :-Punned down thickness of sand shall be considered for measurement)
Supply and laying un-reinforced precast concrete cable cover factory made, class HV, type I, flat of size 300mm x 180mm x 40mm complete all as specified and directed.
M & L for sub class "B" brick covering laid dry flat (width equal to be length of the bricks) over sand cushioning along the length of cable complete all as specified and directed.
Supply and fixing LED type street light fitting pressure die cast aluminium housing (Heat sink) for effective thermal management,IP 66,Operating Voltage 140-270 Volts, with Lens and Surge Voltage Protection of luminaires 60 watt LED 6000K complete fitting including 1.50mtr(minimum) 2core PVC insulated aluminium cable from conductor to street light fitting all as specified.
Supply and fixing street light bracket made out of GI pipe 40/32 mm suitable for 60watt LED Street light, medium grade 1.2 mtr long made to shape with fixing clamps of MS flat 40x6mm nut bolts etc for street light all as specified and directed
Supply and fixing in replacement thermoplastic polycarbonate cable junction box hinged door type of size 200x160x 98 mm for 3 Phase and Nutral incoming cable, 3 Phase and Nutral outgoing cable and single Phase & Nutral connection for light fitting with aluminiuam bus bar of 25 x 3mm strip, 4 pole, 415 volt with insulator porceline and one MCB sp 6 Amp, 240 Volt and clamp system (screw less), shock proof safe IP-55, weather proof, rust, dust and water proof internally embedded gasket with provision for cable entry through gland alongwith MS clamps and mounting brackets as required at site complete all as specified & directed.
Supply and fixing in replacement of onload change over switch 4 pole 315 Amp in existing LT panel complete all as specified and directed.
KARACHI ELECTRIC & TRADING CO.
UNITED ENGINEERING CORPORATION
Santokh Singh and Associates
Raman Electric Trading Co
BHARAT ENGINEERS
M/S BALWINDER SINGH
Bharat Builder
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .