Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.3 LAccepted-AOC | L1 | Accepted-AOC AWARD OF CONTRACT | |
| 2 | L2₹49.5 L+₹33,222 (0.68%)Rejected-Finance 121004 | L2 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 3 | L3₹49.7 L+₹56,685 (1.15%)Rejected-Finance PAYYOOR KOTTARATHI HOUSE POST AMAYUR KOPPAM PALAKKAD KERALA 679303 | PALAKKAD | KERALA | 679303 | L3 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 4 | L4₹49.9 L+₹71,692 (1.46%)Rejected-Finance | L4 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 5 | L5₹49.9 L+₹75,720 (1.54%)Rejected-Finance 30 20 ATHIPALAYAM ROAD CHINNAVEDAM PATTI POST COIMBATORE 641 006 TN | COIMBATORE | COIMBATORE | TAMIL NADU | 641006 | L5 | Rejected-Finance BEING NOT LOWEST TENDER |
Tender Value
Refer Docs
EMD Value
₹98,400
Closing Date
6 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF SULUR
Garrison Engineer AF Sulur Military Engineer Services Kangayampalayam Post Sulur Coimbatore 641 401
PROVISION OF CERTAIN SANCTIONED WORK AND MINOR WORK AT AFS SULUR
2023_MES_618975_1
8610/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE AF SULUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE AF SULUR
₹98,400
Yes
21 Oct 2023
15 Sept 2023
7 Oct 2023
15 Sept 2023
6 Oct 2023
30 Sept 2023
15 Sept 2023 - 27 Sept 2023
Amount
SCHEDULE A BOQ
Supply, installation, testing & commissioning of maintenance free chemical earthing system comprising 17mm dia copper bonded rod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducing liquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation complete all as specified and directed.
The unit quoted rate shall deem to be included for the following :- (i) Prior to installation of maintenance free chemical earthing, soil resistivity test to be carried out at the location where earthing work to be done in presence of Engr-in- Charge/JE (E/M),user and the report has to submit to Garrison Engineer with recommendation of manufacturer, if required additional interconnection of earthing (not more than 04 number of earthing) to achieve earth result less than 1 Ohms. The arrangement done for soil resistivity testing and submission of report with recommendation deemed to be included in the quoted rate.
(ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors.
(iii) Rate of earth energizer compound of 25 Kg of 02 bags and earth resistance reducing liquid 10 litre per cane for each pit deemed to be included in the quoted rate.
(iv) Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor before commencement of work.
(v) Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintained duly signed by all concerned. After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained.
(vi) Earth resistance tester will be provided by the contractor. Tester should be calibrated from authorised company/ lab.
(vii) The contractor shall give a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion.
(viii) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock.
(ix) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is maintained.
(x) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing per each earthing shall be retained from payment due to the contractor for the guarantee period.
(xi) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH valve should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete.
(xii) The electrode shall carry manufacturer's name .
(xiii) The connection clamp shall be permanently welded to the copper bounded rod to avoid any kind of connectivity loss, The pre-welded copper bounded rod shall not need any additional clamp for termination.
(xiv) Copper strip of size 20 x 3 mm should be fixed on proper post insulator at the instrument end (cost for copper strip up to 7.5m is deemed to be inclusive in quoted rate). Any additional requirement will be paid and measured separately under relevant item here-in-below
(xv) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm.
(xvi) The contractor shall submit CPRI India certified document for copper bonded rod to ensure genuity of material.
(xvii) Sign board of mild steel 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide Zinc chrome primer showing result of earthing should be fixed near the earth pit after completion as directed by engr -in- charge.
(xviii) Earth work such as auguring and making good the surrounding area shall carried out in any type of soil.
S & F Earth pit cover made of heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 9.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm dia for each electrode pit complete all as specified and directed.
Note for Item No 21 :- The contractor shall submit load bearing capacity certificate from the manufacturer.
Supply and fixing copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc all as directed.
S&F epoxy base insulators of suitable size 40mm height for fixing copper earth strip on wall/ceiling/floor/poles etc. complete all as specified and as directed
M&L for recharging of existing defective earth pit after excavation up to one feet depth of surrounding the earth pit as notified by the Engr-in-Charge by pouring the Earth Re-charger Hydrate Crystalline Gel Earthing Compound packing of 6 Kgs Bucket for each earth pit with Water Soluble soil Reactivation Earthing Compound for earth resistance enhancement in all type of existing earth pits, to have environmentally & metallurgically Safe, Non-Corrosive, eco friendly, and purity of the compound is 98-100%, to enable to be effective for min 12 to 18 months from the date of completion, complete all as specified and as directed.
Note for Item No 25 :- Earth pit will be checked pre and post recharging the pit
Resistance after using the gel should reduced by 60-70%
Testing and commissioning shall be done by the contractor
S & F earth pit locater/sign boards fabricated with 1meter long flat iron of size 50mm width x 3 mm thick, duly fixed in concrete block of size 100mmx100mmx100mm and other end mounted with equilateral triangular shaped steel plate (100mm length in each sides) of 3mm thick duly welded and treated with two coats of synthetic enamel paint over one coat of red oxide primer and duly marking of numbers on plate complete all as specified and directed.
Supply, installing, testing and commissioning of wall mounted split type AC of capacity 1.5 TR, (indoor/outdoor unit complete) with 5 star rating and EER 3.2, inverter technology and cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality complete all as per specified and directed
Note for Item No 30:- Copper tube, insulation materials, clamps, out door unit stand and water pipe from condenser unit etc as required shall be arranged by the contractor and cost for the same is deemed to be inclusive in this item.
Supply and fixing and testing of 4 KVA capacity Voltage stablizer for automatic operation, single phase naturally air cooled , copper wound, indoor type & designed for input variation between 170V - 250V with output voltage stabilized at 230 V with accuracy of ± 2.5% complete all as per manufacturers instructions and directed by Engineer-in-Charge.
M&L for sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and including suitable size non metallic PVC conduit / casing capping and all accessories fixed to wall / floors along with 1 run of 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly complete all as specified and as directed.
Note for Item No 33:- (a) 2 runs of 4 sqmm cable along with 1 run of 4 sqmm cable for earth conductor and one run of PVC conduit/ casing capping shall be measured as one length.
(b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
Supply & fix industrial type metal clad plug top & socket single pole and a neutral link earth enclosure with one MCB SP 32 Amp complete all as specified and directed
S & F Digital 2 AC wall mounting type cyclic timer for automatic change over with two heavy duty 30 Amp relay output capable to take load of AC-1 and AC-2 up to 2 Tons complete with following technical specification as per manufacturers instructions and directed by Engineer-in-Charge.
Note for Item No 37 :- (i) Operating Voltage Range :- 90 V to 440 V AC, 50 Hz
(ii) Maximum contact rating :- 30 A @ Unity PF
(iii) Technology :- Advanced Micro - Controller with Memory Backup
(iv) Mounting :- Wall or board mountable
(v) Display :- 16 Characters x 2 lines Multi- info LCD with Back-light
(vi) Setting :- Simple 3 buttons to set AC-1, AC-2 ON and OFF Times independently
(vii) Modes :- Auto & Manual Modes
(viii) Memory Backup :- Up to 7 Years for the setting done for AC-1 & AC-2 by way of replicable coin cell
Suppy and fix high precision electrical/ digital thermo hygrometer with touch screen wall mounted weather station with orange back light display showing temperature in degree celcius/faren heat, switchable all time/24 hours maximum minimum temperature and humidity complete all as specified and directed.
Note for Item No 46 :- (i) The temperature measuring range :- (-) 20⁰C to (+) 70⁰C / (-) 4⁰F to (+) 158⁰F with accuracy + 1⁰C /+ 1.8⁰F Resolutuon :- 0.1⁰C / 0.1⁰F
(ii) Humidity measuring rage :- 30%-70% RH with accuracy + 5% Resolutuon :- 1% RH
(iii) The equipment shall be capable to measure real time temperature and humidity along with maximum and minimum value of all time/24hour temperature and humidity
Taking down carefully aluminium point wiring in & including wood battens, surface conduit and board/ blocks etc or through conduits for light, socket or power point, fan point complete including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets , light fitting etc and making good disturbed surfaces of walls, floors etc. complete all as specified and directed.
M&L point wiring using approved colour coding as per IS with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through PVC casing and capping fixed on surface of wall, columns etc including PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) copper conductor as earth wire and connected to earth dolly complete all as specified and as directed for the followings complete all as specified and directed.
One light point/fan/bell point controlled by one switch
All as per item No. 51 here in before but for one 3 pin socket outlet 5 amp on the same board
All as per item No. 51 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 51 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
Supply and fix modular switch 1 way 6 amp.1 module complete all as specified and directed.
Supply and fix modular switch 1 way 16 amp.1 module complete all as specified and directed.
Supply & fix modular Socket, 6A - 2/3 pin combined, 2 module complete all as specified and directed.
Supply & fix modular Socket, 6A/16A - 2/3 pin combined, 2 module complete all as specified and directed.
Supply & fix modular bell push 6 amp, 1 module complete all as specified and directed.
Supply & fix modular white cover plate with frame, 1 module complete all as specified and directed.
Supply & fix modular white cover plate with frame, 3 module complete all as specified and directed.
Supply & fix modular white cover plate with frame, 6 module complete all as specified and directed.
Supply & fix modular white cover plate with frame, 8 module complete all as specified and directed.
Supply & fix modular Metal flush box, 1/2 module complete all as specified and directed.
Supply & fix modular Metal flush box, 3 module complete all as specified and directed.
Supply & fix modular Metal flush box, 6 module complete all as specified and directed.
Supply & fix modular Metal flush box, 8 module complete all as specified and directed.
Supply & fix buzzer, Ding Dong, AC, 230 volts, single pole complete all as specified and directed.
Supply & fix step type modular fan regulator, 120 watt, 2 module complete all as specified and directed
Supply & fix in repair single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and directed
Supply & fix ceiling rose, 3 phase / PVC / polycarbonate, isolated body complete all as specified and directed.
S&F in repair factory made powder coated distribution board TPN, 4 way double door including bus bar, Neutral bar, standard DIN rail, earth bar complete all as specified and conforming to IS: 8623 all as specified.
S&F in repair factory made powder coated distribution board TPN, 8 way double door including bus bar, Neutral bar, standard DIN rail, earth bar complete all as specified and conforming to IS: 8623 all as specified.
S&F in repair factory made powder coated distribution board SPN, 8 way double door including bus bar, Neutral bar, standard DIN rail, earth bar complete all as specified and conforming to IS: 8623 all as specified.
Supply & fix in repair triple pole neutral, MCB 63 amp, 415 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 complete all as specified and directed.
Supply & fix in repair triple pole neutral, MCB 32 amp, 415 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 complete all as specified and directed.
Supply & fix in repair single pole neutral, MCB 32 amp, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 complete all as specified and directed.
Supply & fix in repair single pole MCB 6 to 32 amp, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 complete all as specified and directed.
M&L for Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 4 runs of 6 sqmm drawn through in and including suitable size PVC casing capping and all accessories fixed to wall/floors along with 2 runs of 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring complete all as specified and directed.
Note for Item No 80:- (a) 4 runs of 6 sqmm cable along with 2 runs of 6 sqmm cable for earth conductor and one run of PVC casing capping shall be measured as one length.
(b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
M&L for Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and including suitable size PVC casing capping and all accessories fixed to wall/floors along with 1 run of 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring complete all as specified and directed.
Note for Item No 83:- (a) 2 runs of 4 sqmm cable along with 1 run of 4 sqmm cable for earth conductor and one run of PVC casing capping shall be measured as one length.
(b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
M & L earthing with Galvanised Earth Plate Electrode 600x600x 6mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with Galvanised Earth Strip of size 32x6mm by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar including GI 40mm bore (dia) light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt, Magneisum Sulphate (1 : 1 : 0.5) in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete 1:3:6, type C-1 using 20mm graded stone aggregate and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 type B-1 using 20mm graded stone aggregate, reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in any type of soil, returning, filling in and removal of surplus Spoil disposal to out side MD land and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and testing on Completion including taking down old unserviceable one, complete all as per specified and directed.
Note for Item No 86:- (a) All Joints should be joined by Exothermic Welding or Brazing.
(b) After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge, User and proper record shall be maintained duly signed by all concerned.
(c) Earth resistance tester shall be provided by the contractor. It should be calibrated from authorised company/ lab.
(d) After testing if desired earth resistance of less than 5 Ohm is not obtained, the earthing will be redone without extra cost to Govt till desired result is obtained.
Neptune Engineers and Builders
pk janardhanan
eurekaenterprises
K S MUTHU CONSTRUCTTIONS
devan enterprises
CAK Enterprises
Lucky Enterprises
D.R ASSOCIATES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .