HQ CWE SRI GANGANAGAR
HQ CWE POST BOX 48 SRI GANGANAGAR-335001 (Rajasthan)
REPAIR/ REPLACEMENT TO ROOF TREATMENT, PLUMBING AND SANITARY FITTING UNDER AGE B/R-II OF GE SGNR MIL STN
2026_MES_793260_1
CA NO CWE SGNR/TOKEN-63 OF 2026-27
Open Tender
Civil Works
Item Rate
180 days
GE SRI GANGANAGAR
Class D and above Category a (i)
8 documents required · 8 mandatory
₹500
GE SRI GANGANAGAR
₹60,000
Yes
10 Oct 2026
10 Oct 2026
2 Nov 2026
10 Oct 2026
31 Oct 2026
24 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for reinforced cement concrete type B1 1:2:4 (20 mm graded aggregate) as in slab supported on walls, beam and column in floors, roofs,landings,balconies,deck slab, parapet walls and in shelves and etc and setting in mortar complete with joints to match complete all as specified and directed by engr in charge. Note : Rates of Demolition of RCC of any descrition are included | 1.5 | Cum | - | - |
| 2 | Formwork to sides and soffits of floor or roof beams, beam haunch ings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, in flat surfaces etc. complete all as specified and directed by Engr in charge | 10 | Sqm | - | - |
| 3 | M & L mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending, hooking ends and binding with mild steel wire (annealed) not less than 0.90mm dia | 117 | Kg | - | - |
| 4 | M&L brick work with sub class B bricks straight or curved on plan exceeding 6 mtr mean radius in cm 1:6 etc including demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches , pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles.complete all as specified and directed by Engineer - in - Charge. | 6 | Cum | - | - |
| 5 | Dismatiling brick tiles or terracing tiles, single layer on roofs and mud phuska complete all as specified and directed by Engineer - in - Charge.ded or chamfered on edges, complete, all as directed. | 1,673.25 | Sqm | - | - |
| 6 | OVERLAY- PU BASED ELASTOMERIC LIQUIED MEMBRANE SYSTEM FOR EXPOSED ROOF : Providing and applying polyurethane liquid roof waterproofing with improved water ponding capability, elastomeric high build liquid membrane for concrete roofs for exterior wall and exposed surface with solid content not less than 80% and solar reflective index not less than 106 as per (ASTM E1980-19)/tear strength ~20 N/mm (Free film, 14 days, +30 degree C) (ASTM D624) and tensile strength >= 2 N/mm2 (ASTM D4541), elongation 350 to 400% as per ASTM D412 and crack bridging ability upto 2mm.
(a) After proper surface preparation, Apply one coat of Primer for PU coating as per manufacturers specification.
(b) Apply 1st coat of ShaliUrethane® BTD (white) @ 650 gm / m²(minimum) or equivalent by brush / roller while prime surface is tacky, Spread waterproofing reinforced Glass Fiber mash of 45 GSM with overlaps of 50 mm in both directions when the surface is still tacky. Allow 1st coat to dry.
(c ) Apply 2nd & 3rd coat of ShaliUrethane® BTD (white) @ 650 gm / m² (minimum) or equivalent by brush/roller.
Make : Fosroc/Sika/Choksey/Bostik/STP/ Asian Paints/Berger Paints
Note : (i) The Minimum dry film thickness (DFT) of roof treatment shall be 1.5mm if any shortfall in thickness of above treatment the same shall be achieved by additional coat.
(ii) The procurement of material and execution of the work of water proofing treatment shall be carried out by authorised applicator approved by GE.
(iii) The manufacturer/authorised applicator shall give a warranty for the performance & durability for 10 years. | 2,231 | Sqm | - | - |
| 7 | M&L Providing, cement concrete 1:2:4, type B0 using 12.50 mm graded stone aggregate with WPC as per manufacturer's instruction in roof kerbs or mud stops/roof padding, roof kerbs, rounded or chamfered on edges, making khurra etc complete all as specified and as directed by Engineer-in-Charge.
Note- Qty of WPC/SBR measuredand paid saperately. | 100.4 | Cum | - | - |
| 8 | M&L 15-20 mm thick cement plaster with ready mixed plaster material with WPC as per manufacturer's instruction on roof top surfaces finished even and smooth without using extra cement including all as specified. (Note-Qty of WPC measured and paid saperately). | 111.55 | Sqm | - | - |
| 9 | M&L 5 mm thick cement plaster in ready mixed plaster on ceiling surfaces finished even and smooth without using extra cement including taking down plastering on lathing (other than wire-netting), without
removing lathing, in cement mortar all as specified. | 125 | Sqm | - | - |
| 10 | Supply of SBR waterproofing compound @ 2% of per kg cement or as per manufacturer's instruction used complete all as specified.
Make : Fosroc/Sika/Choksey/Bostik/STP/Berger Paints / Asian Paints | 615.76 | Kg | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.26 MB
BOQ_889597.xls
BOQ • 0.34 MB
Tender63.pdf
Tender Documents • 1.16 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .