| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.2 LAccepted-AOC 210 14 R B AVENUE KOL 29 | KOLKATA | KOLKATA | WEST BENGAL | 700029 | L1 | Accepted-AOC that the bid is L1 | |
| 2 | L2₹9.0 L+₹1.8 L (25.3%)Rejected-Finance 27 C DPP ROAD KOLKATA 700047 | KOLKATA | SOUTH 24 PARGANAS | WEST BENGAL | 700047 | L2 | Rejected-Finance that the bid
is not L1 | |
| 3 | L3₹9.7 L+₹2.6 L (35.9%)Rejected-Finance 28 SAMBHU BABU LANE KOLKATA 700014 | KOLKATA | KOLKATA | WEST BENGAL | 700014 | L3 | Rejected-Finance that the bid
is not L1 | |
| 4 | L4₹9.9 L+₹2.7 L (37.6%)Rejected-Finance 24C GOABAGAN LANE KOLKATA 700 006 | KOLKATA | KOLKATA | WEST BENGAL | 700006 | L4 | Rejected-Finance that the bid
is not L1 | |
| 5 | L5₹10.0 L+₹2.8 L (38.8%)Rejected-Finance 49 1 ISWAR GUPTA ROAD KOLKATA 700006 | KOLKATA | KOLKATA | WEST BENGAL | 700006 | L5 | Rejected-Finance that the bid
is not L1 |
Tender Value
Refer Docs
EMD Value
₹19,976
Closing Date
6 Dec 2021, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE I KNHED PW Dte.
KIT Building Annex, 4th Floor,P-16, India Exch. Place Extn., Kolkata -700073
Conversion of Ward 5 and Ward as General Ward of Beliaghata Campus Dr BC Roy Post Graduate Institute of Paediatric Sciences Kolkata for preparedness for next wave of COVID 19 Pandemic Electrical Installation Work
2021_WBPWD_352453_1
WBPWD/EE/KNHED/NIQ-104/21-22
Open Tender
ELECTRICAL WORKS ORG
Item Rate
7 days
Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹19,976
14 Nov 2024
24 Nov 2021
8 Dec 2021
26 Nov 2021
6 Dec 2021
26 Nov 2021
120 days
Amount
Supplying and delivery of 1.1 KV grade armoured Alminium XLPE cable on wall as per G.S. (Make: Gloster/Havells/Nicco) 4 core 50 sqmm(Light and Power DB VTPN)
Laying of cable on existing cable tray incl. earthing attachment in 2 x10 SWG GI (Hot DIP) wire, making holes etc. as necy., mending good damages 4 core 50 sqmm
Supply and fixing compression type glandcomplete with brass gland brass ring and rubber ring for dust and moisture proof entry of XLPE/PVC armoured cable. 50 sqmm 4core
Finishing the end of following XLPE/PVC armoured cables bycrimping method incl. supplying and fixing solderless socket(Dowels make), tapes, anticorrosive paste & jointing materials 50 sqmm 4core
Supplying and fixing double door 8 way Vertical TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.(as per Make: Legrand/L&T AU/ABB/ Siemens ) INCOMING- Supplying and fixing 415 V, 160A Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in DBs and necessary connection -1No.(Make:Legrand) OUTGOING- Supplying and fixing 240V 63A TP MCB of Breaking capacity 10kA & C characteristics on 1din rail of existing DBs and necessary connection-8 nos.(Make: Legrand/ABB/L&T)
Supplying and fixing 415V 6/10A, 8 way TPN MCBDB (make-Legrand/L&T/Siemens ) comprising with of 1no. 63A FP Isolator and 24 nos.,(6- 32)A SP MCB with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment
Supplying and fixing 230V 6/10A, 2+4 way SPN MCBDB (make-Legrand/L&T/Siemens )comprising of 1no. 20A DP Isolator & 4nos. 6/10A SPMCB double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment
Supplying and fixing 230V 6/10A, 2+10 way SPN MCBDB (make-Legrand/L&T/Siemens )comprising of 1no. 40A DP Isolator & 10nos. 6/10A SPMCB double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish [only PVC Rigid Conduit on ceiling ] Avg Run 10 Mtr
Do-----Do------ 5A on board point.
Distn. Wiring in 1.1 Kv gr. Single core stranded ‘FR’ PVC insulated & unsheathed cu. wire (Havells / KEI / Finolex/RR-Cable) in 20/32/40 mm size PVC rigid conduit ‘FR (precession) incl. necy. Fitting as reqd. a) 2 x1.5 sqmm + 1x 1.5sqmm for ECC
b) 2 x2.5 sqmm + 1x 1.5sqmm for ECC
c) 2 x 4 sqmm + 1 x 2.5 sqmm for ECC
d) 2 x 6 sqmm + 1 x 4sqmm for ECC
e) 4 x10 sqmm + 2 x 16 sqmm for ECC
Finishing end of copper wire and PVC/Al cable of the fol;owing sizes by crimping method as per GS 10 sqmm
S & F of Single LED Tube light fitting [Make - Philips cat no. TMC 501 P 1 x T-LED / Crompton cat no. IGP161 LT8-16 / Wipro, cat no.WIO921208] complete with 18/20 Watt LED tube lamp [Make - Philips Master LED tube model no.18W 865 T8 I 2100lm / Crompton cat no. LTT8-20 / Wipro cat no.- LL13-181-65SE ] suspended below the ceiling with S&F 2x20mm dia EI conduit up to 25 cm long with 'L' type MS clamp and making connection as to GS.
S & F of Twin LED Tube light fitting [Make - Philips cat no. TMC 501 P 2x T-LED / Crompton cat no. IGP162 LT8-16 / Wipro, cat no.WIO922208 / complete with 2x18/20 Watt LED tube lamps [Make - Philips Master LED tube model no.18W 865 T8 I 2100lm / Crompton cat no. LTT8-20 / Wipro cat no.- LL13-181-65SE ] suspended below the ceiling with S&F 2x20mm dia EI conduit up to 25 cm long with 'L' type MS clamp and making connection as to GS
S&F of 230V 18 watt LED Slim surface panel circular type corresponding fixing in top of the cercular box .(make-Philips cat no- DN9413B LED 15S 6500PSUWHS1 /CG cat no- Cool daylight LCDSPLN-R-18-CDL )
Extra for suspension exceeding 25cm with s & f additional 2 no. 20mm dia conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as reqd. by 2 x 24/ 0.20 mm (1.5 sqmm) flexible copper wire of 1.10mt. length
S&F 240V, 100W rotary step type electronic fan regulator on board with making necy. Connection .(make Anchor/Legrand)
S & F MS fan clam of two piece type for RC celling as per approved speceification ,fabrication from 40 mm x 9 mm MS Fflat including making good damages to building roof with satisfactory finishing and painting - (As per Drawing no. 475 of PWD Specification Book-May 1991)
S& Fixing 240V 50 Hz 56" sweep (1400 mm) ceiling fan complete with down rod,Canopy,fork etc.(Make- CG-HS plus 5star ) and Fixing the ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by3x1.5 sqmm single core stranded pvc insulated unsheathed copper wire .
Supply & Fixing 1420 rpm 240V AC Heavy duty 12’’ Exhaust Fan including cutting hole & mending good damages .(Make : EPC/CG)
Supply & Fixing 230V 50Hz 400mm sweep heavy duty full metal body /Decorative type wall bracket fan with all accessories on wall with necy. bolts & nuts. ( make- CG/EPC/Cinni)
S & Fixing of extra suspension 3/4 inch 14 SWG M.S Fan downrod ( avg length 3 fit)
S & F 240V,25A,3 pin plug socket 2 module (Legrand,Myrius cat no-673145/Crabtree) without switch & with plug top on 2 Module switch board with top cover plate fixed in wall including s&f switch board and cover plate and making necy. connections with PVC Cu wire and earthing continuity wire etc. [for AC point)
S & F 240V, 4 nos. 16A Plug socket ( Anchor,black) & 4 nos. 6A plug socket ( Anchor,black) with separate 4 nos. 16A Piano key type switch( Anchor,black) & 4 nos. 6A Piano key type switch (Anchor,black),240V LED indicator( colour- Green, make -L&T, cat no-EPLR240A) & 16A switch type SP MCB (legrand / havells) on sheet metal switch board embedded in wall incl. S & F 450 mm x 200 mm x 65 mm MS (16SWG ) Switch board and bakelite top cover ( Blue) of 3 mm thick by brass screws after making housing for switch by cutting bakelite cover and making necy connection for CU. wire as required.( For UPS board)
S & F 240V, 16 A piano key type switch ( make- Anchor ) on sheet metal switch board (100 mm x 100 mm x 65 mm ) with bakelite top cover by screws after making housing and making necy. Connection for GYSER
S & F 240V, 16 A piano key type Socket( make- Anchor ) on sheet metal switch board (100 mm x 100 mm x 65 mm ) with bakelite top cover by screws after making housing and making necy. Connection for GYSER
S&F multi plug board of size 240 x 200 x 65 mm M.S. Box comprising with 2 No. 250 V 6 pin 20A plug socket with 2 No. 20A piano key type switch, 2 nos. 250V 6A 5 Pin plug socket with 2 nos. 6A Piano Key type switch 1 No. Indicator & (6-16) A fuse (Anchor /Vinay Make) and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
S&F 240V,25A single phase starter 2 module(legrand, Myrius cat no-673031) with 25A switch type DP MCB (C-curve) (legrand/ Crabtree/ North West) with 4 module modular GI box & 4 module frame(legrand Myrius-689009&673224) cover and making necy. Connections with CU wire and earth continuity wire etc.(Make-Legrand/crabtree).
Supply & Fixing of perforated GI cable tray with perforation not more then 17.5% suspended from ceilling incl. S&F GI connector 6mm dia MS suspender, bolts & nuts, steel fastener etc. As required of the following size incl. Al painting of MS support. with 25x25x3 mm angle iron support- 300x50x25mm (18SWG)
Dismaintaling the all old tubelight fittings & all the old electrical equipments of Ward and all material goes to section store as per EIC.
Special Terms and Conditions 1. It is stated that the above work place is existing COVID Hospital, In case of any mishap or accidental to any staff that deputed by the agency the whole responsibility is to be borne by the concern agency. 2. The Agency shall be responsible for provisioning of all COVID safety measures including regular sanitiziation of work places, vaccination of employees and compliance of stated directive and COVID appropriate norms. 3. All the issues related to the safety of the staffs should be taken care by the agency itself. (Defect Libilities period for 01 year from the date of completion of work) (Rate should be quotated including all taxes and duties)
M/S. TOAD TO TOWER
M/s Singh Electrical Works
ALPHA ELECTRICALS
Electromech Engineers Co-Operative Society Ltd.
technical_679640.pdf
PDF • 0.26 MB
techsummary_679640.pdf
PDF • 0.26 MB
finance_679640.pdf
PDF • 0.26 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_679640.pdf
PDF • 0.27 MB
AOC.pdf
PDF • 0.24 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .