Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹4.8 LAccepted-AOC | L-1 | Accepted-AOC Work Awarded | |
| 2 | Rejected-Technical 33 KISHAN KUNJ EXT PART II LAXMI NAGAR DELHI 110092 | EAST DELHI | DELHI | 110092 | - | Rejected-Technical Rejected due to non availability of registration documents with AO (Engg.) HQ as per terms and condition of the NIT. |
Tender Value
Refer Docs
EMD Value
₹9,472
Closing Date
7 Feb 2024, 12:00 pmClosed
Ex. ENGINEER (ELECT)-I
OFFICE OF THE Ex. ENGINEER (ELECT)-I, SHAHDARA (N) ZONE, KeshavChowk, Delhi-110053
Improvement of Existing installation and provision of Acs in Municipal Homeopathic Dispensary New Seelampur, Ayurvedic Dispensary New Seelampur and Ayurvedic Dispensary D Block New Seelampur in ward no. 225 under Shahdara North Zone.
2024_MCD_184005_1
EE(E)-I/Sh.N/MCD/23-24/TC-72/1
Open Tender
Electrical Works
Item Rate
90 days
As per NIT
Please refer Tender documents.
4 documents required · 4 mandatory
₹590
₹9,472
31 Jan 2025
1 Feb 2024
7 Feb 2024
1 Feb 2024
7 Feb 2024
1 Feb 2024
Amount
approved rate
122.1.47:Supply of 250 mm (10 inch) sweep 1250 rpm exhaust fan Fresh Air Type complete with shutter blades etc. as required.
122.2.39:S/I/T/C of LED Tube type luminaire 20 Watt rating complete with polycarbonate housing batten integrated electronic driver prewired with high efficient LEDs with the following:(a) Total system wattage 20 watt +/- 5%(b )Luminous efficacy lumens/watt >=95 (c)Power Factor >=0.95
122.2.77:SITC of On-line UPS with inbuilt isolation transformer suitable for single phase AC input and single phase AC output, Floor mounted type, indicative power backup time of 60 mins through SMF batteries. 3KVA
122.2.114:S/I/T/C of stand for split AC
122.2.115:S/I/T/C of 4 KVA Voltage Stabilizer having input voltage 150V-270V and output voltage 195-245V
122.2.117:S/I/T/C of copper pipe for split AC
122.2.118:S/I/T/C of Drain Pipe
122.2.119:S/I/T/C of 3 Core, 4 Sqmm. Electrical wire for Air Conditioner
122.2.131:Supply, Installation, Testing and Commissioning of 1.5 Ton, 5 Star rated Inverter Split air conditioner with rotary compressor (R32 Refrigerant) having copper condenser complete with outdoor unit as required.
OD19258/2023-2024:SITC of 1200 mm sweep BEE 5 star rated AC ceilling with brussless direct current motor, class of insulation:B, 3 nos. blade,30cm down road 2 nos. canopies shackle kit safety ropr,copper winding, power factor not less than .9,service value minimum 6.00,air delivery minimum 210 cmm,350 rpm,THD less than 10%,remote or electrnoic regulator unit for speed control and all remaining accessories including safety pin nuts,bolts,washertemperature rise=75 degree,insulation resistance more than 2 megha ohm,suitable for 230 v,50 hz,single phase ac supply, earthing etc complete as required fan for suitable for 230 V, 50 Hz AC supply.
OD19259/2023-2024:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required
OD19260/2023-2024:Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required. Upto 450 mm sweep
OD19261/2023-2024:Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
OD19262/2023-2024:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
OD19263/2023-2024:"Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole"
OD19265/2023-2024:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door
OD19267/2023-2024:Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required
OD19268/2023-2024:Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.3 pin 5/6 amp socket outlet
OD19269/2023-2024:Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.5/6 amps switch
OD19271/2023-2024:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
Bidder Name
M/s Priyanshi Electricals
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .