Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹17.2 LAccepted-AOC | 1 | Accepted-AOC Awarded | |
| 2 | 2₹28.2 L+₹7.0 L (32.8%)Rejected-Finance | 2 | Rejected-Finance 2 lowest | |
| 3 | Rejected-Technical | - | Rejected-Technical Not qualified | |
| 4 | Rejected-Technical 00 RL QR NO 388 B KALIBARI COLONY ALIPURDUAR JN JALPAIGURI WEST BENGAL 736123 | ALIPURDUAR | WEST BENGAL | 736123 | - | Rejected-Technical Not qualified |
Tender Value
Refer Docs
EMD Value
₹23,000
Closing Date
26 Mar 2021, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE, EWC
3-Civil Lines, Bareilly
Increasing capacity of 33/11 KV Sub-Staions in district Budaun - Asrasi (3x5 MVA to 2x10plus5 MVA), Sheswan R/L (2x5 MVA to 5plus10 MVA) and Nagarjuna (2x5 MVA to 5plus10 MVA)
2021_MVVNL_572691_1
36/EWC(B)/2020-21
Open Tender
Electrical Works
Fixed-rate
90 days
Badaun
As per tender document
3 documents required · 3 mandatory
₹3,540
A/c No. 019205006347, IFSC Code ICIC0000192
₹23,000
10 Feb 2022
18 Mar 2021
27 Mar 2021
18 Mar 2021
26 Mar 2021
18 Mar 2021
180 days
Amount
Part (A)
Loading, unloading and safe carriage of the following materials from any Electy. Store Center of Electricity store division of Bareilly zone.
MS Channel 100x50mm @ 9.5 kg./mtr.
M.S.Angle 75x75x8mm @ 8.9 kg./mtr.
33 KV Lightening Arrestor
33 KV VCB 800A 750 MVA
33 KV I/C control pannel for single T/F
33 KV O/D CT CTR 400/200/1-1-1 A
11 KV VCB I/C CTR 600/300/5A 250 MVA 630 A
11 KV VCB O/G CTR 200/100/5A 350 MVA
11 KV Cable 3x300 Sq. mm XLPE
Earthing of indoor & outdoor equipments of Sub-Station after proper welding of joints and painting of earth strip above soil with proper clamp etc. as per RESPO approved drawing & resistance of earthing should be not more than 2Ω as per as per details given below.
Providing of bore well type pipe earthing 5mtr. below the water level but minimum depth of pipe earthing should be 40 mtr. at T/F neutral, LA. & equipment stuctures by using Ist class GI Pipe (ISI Mark)of size 40 mm dia.(All the required materials will be provided by firm.)
Making of triangular bridge for above pipe earthing by using 32 mm dia round bar & GI strip of size 50x6 mm. (All the required materials will be provided by firm.)
Supply of GI strip of size 50x6mm for earthing of all newly erected structures and equipments in switchyard including cutting, fixing & proper welding with equipments. All LA will be seprately earth also as per RESPO norms. (All the required materials will be provided by firm.)
Installation of followig equipments on their respective structures including mechanical & electrical fixing after proper adjustment on their structure.
Lightening Arrestor (will be provided by Department).
33 KV VCB complete (will be provided by Deptt.)
33 KV CT (will be provided by Deptt.) (03 Nos)
Complete laying and termination of copper control cables from 5 MVA power T/F, 33 KV VCB, 33 KV CT in the out door switch yard to the Transformer relay control panel inside the control room including cost of all materials and labour required for proper completion of works as per RESSPO drawings, including cost of testing of transformer, VCB, CT, relay pannel & proper relay settings as per requirement etc.
Making of M.S. Angle Ladder type frame of Angle (75x75x8mm) & M.S. Strip (50x6mm) near power transformer for power cable with concreting of the same in the ground and proper clamping (50x6mm) of the same with transformer cable.
Making of M.S. Angle frame of (75x75x8mm) in L shape to connect T/F Neutral by flexible copper strip including cost of copper strip & will be connected to newly constructed well type earthing for Power T/F Neutral as per RESPO norms.
Laying of 11KV cable of different size from power T/F to control room I/C and control room to outside D/P. 11 KV Cable will be layed in brick trench constructed below 750mm to the ground level over the ganga sand. brick trench will be constructed by Ist class bricks covering three sides of cable, after laying 11 KV Cable brick trench will be filed by Ganga sand & then will be covered by bricks & backfill of soil over cable trench as per RESPO norms.
Erection of 11 KV incoming and outgoing panels (with testing & setting of relays) in substation control room including grouting of Anchor bolts of panel and making of pocket for power cable to insert in panel from trench and complete filling of control room's tranches by river sand.
Erection & testing of 1 No. single T/F Control penel in substation control room including grouting of anchor bolts of panel and making of pocket for control cable to insert in panel from trench and complete filling of control room's tranches by river sand.
Termination of 11 KV 3x300sqmm size XLPE cable by filling 11 KV heat shrinkable type cable boxes including proper connection with LV side of transformer, switch gear panels and double poles by providing suitable connectors.All the 11 KV cable boxes of different sizes make Raychem/Denson. (Cable box will be supplied by the contractor).
Safe removal of existing old 5 mva 33/11 kv power transformer from plinth after disconnecting ht, lt, neutral earthing & wiring connections. draining out of transformer oil from transformer radiator and dismentalling of radiators. Proper placing & stacking of exisiting transformer to suitable place with in substation permises as per instruction of site incharge.
Safe carriage & commisioning (if required) of old & used 5 MVA transformer from site to other substation as per requirement :-
Safe loading & unloading of old & used 5 MVA Transformer with all accessories.
Rate for carriage (per km).
Placing the old & used 5 MVA transformer on the plinth, reassambling of transformer radiators, conservator & changing of all Gasket, testing after earthing of T/F neutral, HT/LT & wiring connection of old & used 5 MVA transformer
Centrifuging of transformer oil of old & used 5 MVA Transformer (if required).
Repairing of damage switchyard fencing.
M/S SUPER ENGINEERING TRADERS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .