Executive Engineer (EM) M-13
Chitra Vihar BP Station Laxmi Nagar Delhi-110092
SITC of CMS SYSTEM AND OTHER ALLIED WORK AT Geeta Colony BPS
2026_DJB_300306_12
NIT No-09 EE (EM) M-13/ (26-27)
Open Tender
Electrical Works
Works
90 days
Chitra Vihar BP Station Laxmi Nagar Delhi-110092
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
A/c.50448339804
₹29,000
31 Oct 2026
21 Oct 2026
27 Oct 2026
21 Oct 2026
27 Oct 2026
21 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | SITC of Chlorine Analyzer- Ready to use system for measuring free chlorine, chlorine dioxide or ozone. The measuring system consists of the following devices: ∙ MAC 100 Multiparameter signal converter ∙ OPTISENS CL 1100 SENSOR. The OPRISENS CL 1100 is a single rod sensor with integrated reference electrode. This potentiostatic sensor with 2 gold electrodes is in combination with our signal converter suitable for measuring free chlorine, chlorine dioxide or ozone. In addition to excellent measurement accuracy this leads to a high chemical and mechanical resistance of the electrode and therefore to a long service life with stable measurement performance, The measuring system OPTISYS CL 1100 is already equipped with flow-through cells for temperature sensor and OPTISENS CL 1100 sensor – ASR – Automatic Sensor Cleaning feature for reliable measurement. ∙ The measuring system is completely mounted and can be easily installed in the measuring loop. ∙ Unique combination of a menbrance-free-sensor with 2 gold electrodes for long-term stability and easy maintenance ∙ Suitable for measuring free chlorine, chlorine dioxide or ozone. A complete measuring system consists of: ∙ MAC 100 Multiparameter signal converter ∙ 1 or 2 sensors ∙ Mounting assemblies Up to two sensors (for identical or different parameters) can be connected to the signal converter. The signal converter MAC 100 can be adapted perfectly for your requirements: you specify the number and type of signal inputs and output; you define the complexity of the measuring point and the number of parameters. The standardized user interface also speeds up commissioning of the device and open access to a wide range of diagnostic functions for devices and processes. The system will also consist of auto manual panel to switch on/off the devices and processes. The system will also consist of auto manual panel to switch on/off the chlorine pump as per thresholds advised by engineer in charge. The Mach 100 should also be mounted in a weather proof MS panel. Make – Krohne Marshall | 1 | Set | - | - |
stage.html
html • 0.02 MB
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.77 MB
BOQ_400857.xls
BOQ • 0.25 MB
cc.pdf
PDF • 0.22 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .